Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.9 L+₹4.0 L (12.4%)Rejected-AOC 0 BINOVA NAGAR KAMRUP ASSAM 781018 UDYAM AS 03 0029196 | KAMRUP METRO | ASSAM | 781018 | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹37.2 L+₹5.2 L (16.3%)Rejected-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹40.4 L+₹8.4 L (26.3%)Rejected-AOC | L4 | Rejected-AOC Become L4 |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
22 May 2021, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur
REPAIR/REPLACEMENT OF INTERNAL WIRING FITTING AND FIXATION OF UNIT 524, REPAIR/REPLACEMENT SECURITY, FLOOD, SOLAR LIGHT, OVERHAULING, REPAIRS OF SOLAR WATER HEATERS, SUMMER APPLIANCES, DG SET AND CONNECTED ITEMS/WK AT MISA CAMP UNDER GE (S) TEZPUR
2021_MES_438464_1
8562
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹76,000
Yes
18 Jun 2021
26 Apr 2021
25 May 2021
26 Apr 2021
22 May 2021
10 May 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fitting etc. and making good disturbed surfaces of walls, floors etc all as specified and directed.
Material and labour for point wiring for one light/call bell/fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FR cable controlled by one way switch, drawn with PVC casing/caping with all accessories incl 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity connected to common earth dolly and sunk cast pressed steel terminal box fixed flush to wall of not less than 1.6 mm thick for mounting of fittings such as switch, socket and speed regulator with 3 mm thick Laminated bakelite sheet cover all as specified and directed. (a) one light/fan/bell point controlled by one, one way switch.
(b) All as per item No 2 but one socket outlet 5 pin 6 amps on independent board.
(c) All as per item No 2 but one 5 amps socket outlet on same board with other switch.
Material and labour for point wiring 2.5 sqmm including 1.5 sq mm PVC insulated, unsheathed multistranded copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one 3/5 pin 15 Amps socket out let on independent board.
Supply and fix Modular switch one way 6 Amp.
Supply and fix Modular switch one way 16 Amp.
Supply and fix modular switch 2 way 6 Amp.
Supply and fix modular bell push 6 Amp.
Supply and fix call bell, AC 230 volts, single pole.
Supply and fix modular socket outlet 2 in 1, 3 pin 6 A.
Supply and fix Modular socket outlet 16 Amps
Supply and fix angular lamp holder, PVC/Polycarbonate type all as specified and directed.
Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals.
Supply and fix modular type electronic fan regulator.Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 1 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 2 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fixing modular white cover plate with frame 12 modules complete all as specified and as directed. Make: Havells/Anchor
Supply and fix, switch socket combination 3 pin, 5 Amps flush type 240 Volts all as specified and directed.
Supply and fix, switch socket combination 2 in 1, 3 pin 5 and 15 Amps, flush type universal, 240 Volts complete all as specified and directed.
Supply and fix in replacement of PVC Square box for mounting angular holder complete all as specified and directed.
Supply and fix in replacement of Surface mounting plastic box 4X4 inch size including all fixing accessories complete all as specified and directed.
Supply and fix in replacement of Surface mounting plastic box 4X7 inch size including all fixing accories complete all as specified and directed.
Supply and fix in replacement of Surface mounting plastic box 8X6 inch size including all fixing accories complete all as specified and directed.
Taking down and Refixing at site ceiling fans 1200/1400 mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of ball bearing, replacement of condenser etc and re-assembling the same including necessary transportation etc complete including taking down all as specified and directed.
S&F in repair of capacitor of cap 3.15 MFD complete all as specified and directed.
Supply and fixing LED fitting 20 watts 6000k very high efficiency enviormental friendly long life mounting on PVC round/square PVC block and making all connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.Make-Havells,Cat No-LHEXBXPNIN1W020
Supply and fixing LED fitting 10 watts 6500k very high efficiency enviormental friendly long life mounting on PVC round/square PVC block and making all connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.Make-Havells,Cat No-LHEXBTP7PIN1W009
Supply & fix in replacement of LED bulb 10 watt complete all as specified and as directed. Make Crampton Greaves/Surya/Bajaj/Havells
S&F in replacement of decorative Trim Clipon LED Panel light not less than 12 Watt, 6500 K unique slimmest recess com surface panel, soul made up of high grade unbreakable polycorbonate material all as specified and directed. Make Havells Model No. LHEAABP7IL1W012
Supply and fix in repair plastic body exhaust fan 250 mm sweep, AC single phase, including electrical connection with twisted three core PVC insulated copper conductor from ceiling rose complete all as specified and as directed. Make: Model- crisp air exh fan of Usha
Supply and fix in repair metal body light duty exhaust fan 300 mm sweep and metal blades with double ball bearing metal protective bird guard, AC single phase, including electrical connection with twisted three core PVC insulated copper conductor from ceiling rose complete all as specified and as directed. Make: Model- Aeroclean Plus DBB GBD of Usha
Supply and fix in repair metal body heavy duty exhaust fan 300 mm sweep 900 RPM and metal blades with double ball bearing metal protective bird guard, AC single phase, including electrical connection with twisted three core PVC insulated copper conductor from ceiling rose complete all as specified and as directed. Make: Model- Turbo HDEF 900 RPM ISI of Usha
Supply and fix in repair metal body heavy duty Exhaust fan 450 mm sweep 1400 RPM and metal blades with double ball bearing metal protective bird guard , AC single phase, including electrical connection with twisted three core PVC insulated copper conductor from ceiling rose complete all as specified and as directed. Make: Model- Heavy duty Turbo HDEF 1400 RPM of Usha
Supply and fixng in replacement of AC three phase electronic Kwh energy meter of rating 10-60A, class 1.0, 3 x 240V, 50Hz, counter type display with transparent hinge type box.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and directed.
Supply and fixing LED Street lights not less than 25W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP66 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions.Make-Havells,Cat No-ENDURAPEARLSL25WLED757SASYTOPCMP
Supply and fixing LED Street lights not less than 30 W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP66 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions..Make-Havells,Cat No-ENDURAPEARLSL30WLED757SASYTOPCMP
Supply and fixing LED Street lights not less than 60W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP66 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions..Make-Havells,Cat No-ENDURAPEARLNEOSL60WLED757PASYTOPC
Supply and fixing in replacement of LED flood light fitting light not less than 70 watt with IP66 protection new generation energy saving very high efficiency,enviormental friendly ,long life with fixing accessories such as braket made out by GI strip ,nutts bolts and washer complete making all connection all as specified and directed. Make-Havells,Cat No-JETA PROFL70WLED757LT G
Supply and fixing street light panel frame size 2, 3 phase having load capacity 12 KW, digital timer 24 Hrs, IP 65, contractor rating 63 Amp, MCB TPN rating 63 Amp complete all as specified and directed. Make-Havells,Cat No-IHXTS09120
Supply and fixing street light panel frame size 1, Single phase having load capacity 12 KW, digital timer 24 Hrs, IP 65, contractor rating 63 Amp, MCB SPN rating 63 Amp complete all as specified and directed.Make-Havells,Cat No-IHXSS03120
M & L for making swan neck end size of not exc. 32mm GI pipe for mounting street light at top of existing LT pole including Clamp, cutting, welding, reaming, finishing ,bending in appropriate size at existing location as directed .
Material and labour for painting to steel tubular pole 9.0 / 11.0 metre long with two coats of synthetic enamel paint up to 1.20 metre height from ground level in 15 cm alternative black and yellow strips and remaining portion with alluminium paint and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified.
S&F in replacement of heating element of 2000 W (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as directed
S&F in replacement of 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as directed.
S&F in replacement of thermostat suitable for water heater of any size/type complete all as directed.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 1.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
S&F in replacement of plug top 3 pin 16 amps ISI marked complete all as directed
S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series all as specified and directed.
M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.
S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed.
S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler all as specified and directed.
S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity all as specified and directed.
S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC all as specified and directed.
S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.
S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed..
S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton, Refrigerator, deep freezer, water cooler capacity complete all as specified and directed.
S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC all per directed by the Engineer-in-Charge.
S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC all per directed by the Engineer-in-Charge.
S&F in replacement of insulation cover of size 5/8" for insulating copper tube of split type AC all per directed by the Engineer-in-Charge.
S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC all per directed by the Engineer-in-Charge.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-22/R-32 as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed.
M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as directed.
S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA all as specified and directed.
Supply only refrigerant R-22 gas in air conditioner of any type make capacity complete all as speciifed and directed.
S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.
S&F in replacemet of water purifier stainer for pre filter of single candle complete all as directed.
Material and Labour for overhauling/servicing of DG set of capacity 125 KVA all as per manufacturer instructions, carrying out the changing of oil filter, air filter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distiled water and other required item will be paid under relevant item as supply only
Cylinder liner
Piston assy
Piston ring
Valve (I/E)
Valve seat
Valve guide
Water pump
head gasket
Engine gasket
Valve seal
O ring kit
Fuel filter 1.1 Ltrs
Lub oil filter 008
Air filter 14/15
Anabond
Main bearing
CR bearing
Thrust washer
Oil seal set
Hose pipe set
Crankshaft grinding
cylinder block checking
C rod bush fitting
Fuel pump & Nozzle repair
Turbo reapiring
Radiator repairing
Self dynomo serviceing
Material and Labour for servicing of DG set of capacity 100 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distiled water, will be paid under relevant item as supply only
Material and Labour for servicing of DG set of capacity 62.5 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distilled water will be paid under relevant item as supply only
Material and Labour for servicing of DG set of capacity 40 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distilled water will be paid under relevant item as supply only
Supply only Kirloskar premium engine oil as per manufacturers recommendation complete all as directed.
Supply only coolent "K' Care geniune for radiator of water cooled engines as per manufacturers recommendation complete as all directed.
Supply only Oil filter element
Supply only Air filter element
Supply only distilled water for battery or radiator of engine used with coolent complete all as directed.
Removing existing unserviceble battery and supplied and fixed lead acid battery maintenance free 12 volts 130AH fully charged complete all as directed.
Supply and fix in repair 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set all as specified and directed.
Dismantling unserviceable turbo charger from DG set of capcity 100 KVA complete and supply and fix new turbo charger as per manufacturer's recommendataion all as specified and directed.
Dismantling self starter of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, completer servicing and refixing after repair, testing/commissioning complete for DG Set any capacity complete all as directed (Note : Replacement of solenoid coil, armeture coil, and pinion gear Shall be deemed in quoated rate)
Supply and fix in repair battery leads set appx 1.25 Mtr long, PVC insulated multistranded copper conductor 70 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on various DG Sets of any capacity installed complete all as directed.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 40 KVA to 125 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
Supply only fuel connection heavy duty rubber hose pipe nylone type having internal dia min 10mm, overall dia 15mm mm includining necessary clamps and end nipple/socket connections etc complete all as directed.
Supply and fix in repair MCCB four pole, 415 volt 63 Amps capacity 30 KA rating with adjustable thermal relay and as per model & make provided in existing panel board complete all as directed.
Supply and fix in repair AMF Panel suitable for 40 KVA DG set, 440 Volts, 3 Phase model 3H.387.50.0PR & make Kirloskar complete all as specified and directed. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose.
KAMAKHYA CONSTRUCTION & BUILDERS
Ms N D Enterpise
M/s Rawat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .