Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.6 LAccepted-AOC 6 573D BHASKARA BUILDING NADAKKAVU P O UDAYAMPEROOR ERNAKULAM KERALA 682307 | ERNAKULAM | KERALA | 682307 | 1 | Accepted-AOC L1 | |
| 2 | 2₹4.9 L+₹35,202 (7.67%)Rejected-Finance | 2 | Rejected-Finance L2 |
Tender Value
₹4.7 L
EMD Value
₹11,700
Closing Date
31 Jan 2025, 3:00 pmClosed
Managing Director
Matsyafed Head Office, Kamaleswaram, Manacaud P.O, Thiruvananthapuram
PMMSY - Need Based Brackish Water Hatchery, Palaikari - Electrical Works
2025_MFED_725714_1
MFED/95/2024-ENGG
Open Tender
Civil Works - Buildings
Item Rate
60 days
Matsyafed Hatchery, Palaikari
Please refer Tender documents.
9 documents required · 9 mandatory
₹950
₹11,700
2 Aug 2025
13 Jan 2025
3 Feb 2025
13 Jan 2025
31 Jan 2025
13 Jan 2025
Amount
$Electrical Works
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.54.2 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
90.10.1.2 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
90.6.5.13 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
90.6.5.14 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
od43052/2024_2025 : Supplying and fixing following rating, four pole, 415 volts, MCCB in the existing MCCB DB complete with connections, testing and commissioning etc. as required.63A FP MCCB 16Ka
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.14.24.1 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.
90.14.24.2 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.
90.14.28.1 : S & F Motor starters of the following ratings
od43053/2024_2025 : Earthing with G.I. earth pipe 3 metre long, 40 mm dia including accessories, and providing<br>masonry enclosure with cover plate having locking arrangement and watering pipe etc. with<br>charcoal/ coke and salt as required
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
od43054/2024_2025 : Supplying and fixing suitable size GI box with modular plate and cover in FRLS<br>on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
od43055/2024_2025 : Supply and fixing wall mounting 16/20A, 3pin (P+N+E), industrial Plug & Socket DB Box with DP MCB socket outlet as required and as directed by officer in charge
od43056/2024_2025 : Supply and Fixing of 18-22W LED tube light fitting, including connection with 1.5sq.mm FRLS PVC insulated copper conductor, single core cable etc. as required
od43057/2024_2025 : Supply and Fixing of 25W LED street light fitting, including connection with 1.5sq.mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required complete with all necessary accessories including OD pipe for mounting the light with all cost of labour and materials
od43058/2024_2025 : METERING KIOSK<br>Supply, installation, testing and commissioning of KSEB metering panel, suitable for accomodating CT operated TOD meter and consisting of 3 nos. of 100 A cutout with HRC fuse, neutral link,100/5A 5VA CT for meter, 100A FP MCCB isolator in separate chamber, inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with locable door with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process, powder coated finish and all mounting accessories as required. The panel shall be with all accessories as per EI/KSEB specification. (Rate for Energy Meter not included
Circuit Board Frame
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od152805/2024_2025 : Supplying and fixing 20mm thick cement board on the existing frame work etc. complete including all cost of materials and labour etc complete as directed by the Engineer in charge
Billionaire Electric Solutions (BID ID -2085819)
Bidder Name
BPE BHARATH POWER ENGINEERS PVT LTD
Billionaire Electric Solutions
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1153572.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .