Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹4.3 L (2.49%)Admitted-Finance 30 HIG A DR AS RAO NAGAR DR AS RAO NAGAR HYDERABAD TELANGANA 500062 | MEDCHAL MALKAJGIRI | TELANGANA | 500062 | ₹1.8 Cr+₹4.3 L (2.49%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical AS PER COMMITTEE RECOMDATION |
| 4 | Rejected-Technical 6 3 883 2 1ST FLOOR TOPAZ BUILDING PUNJAGUTTA HYDERABAD HYDERABAD TELANGANA 500082 | HYDERABAD | TELANGANA | 500082 | - | - | Rejected-Technical AS PER COMMITTEE RECOMDATION |
| Sl No | Description | Qty | Unit | V Ranga Prasad L1 | Iris Infra services private limited L2 |
|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | |||||
| 1.10 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in trenches to a width of 0.30m to 0.45m and for a depth of 1.65m as specified in the Standard Laying practices for Cables including dressing of sides and ramming of bottoms, lift up to 1.65 m, including getting out the excavated soil and then refilling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc and disposal of surplus excavated soil as directed within a lead of 50 m(For All Kinds of Soil) | 31,000 | Per Meter | 245 ₹75,95,000 | 240 ₹74,40,000 Lowest |
| 1.20 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in trenches to a width of 0.30m to 0.45m and for a depth of 1.65m as specified in the Standard Laying practices for Cables including dressing of sides and ramming of bottoms, lift up to 1.65 m, including getting out the excavated soil and then refilling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc and disposal of surplus excavated soil as directed within a lead of 50 m(For Hard Rock Soil -Blasting Prohibited) | 14,000 | Per Meter | 399 ₹55,86,000 Lowest | 467.39 ₹65,43,446 |
| 2.00 | Laying OF PLB /HDPE PIPE 40-50mm dia coupled with sockets in the excavated cable trench as per the standard practices including loading, unloading, uncoiling and transportation from BSNL designated stores to site of work (Pipes, sockets will be supplied by BSNL at stores at no cost. Length of pipe laid is measured for payment | 50,000 | Per Meter | 5 ₹2,50,000 Lowest | 6 ₹3,00,000 |
| 3.00 | Blowing of OFC Cable in cable trench as per the standard practices including allied works like replacing/refixing couplers, Sealing of PLB ends and refilling sand ,refixing RCC covers and back filling in Joint chambers wherever required as per the directions of Engineer in Charge. (The rate includes loading, unloading, uncoiling and transportation of cables from BSNL designated stores to site of work. | 50,000 | Per Meter | 9 ₹4,50,000 Lowest | 15 ₹7,50,000 |
| 4.00 | Boring at a depth of 1.65m using HDD method /Boring/Cutting Black Top or Concrete Road at Road Crossing etc including excavating entry and exit pits & pushing PLB Pipes upto 3 Nos maximum, reinstatement of road and other all operations involved as per directions of Engineer in charge.(Length of Bore/ Length of reinstated road as the case may be is measured for payment) | 5,000 | Per Meter | 399 ₹19,95,000 | 250 ₹12,50,000 Lowest |
| 5.00 | Splicing of all the fibers of OF cable laid at every joint within specified splicing loss range (<=0.02dB) while testing with OTDR and making termination at the ends. All materials, Splicing Machine and labours except Joint Closer to be supplied by Bidder /Vendor). Joint Closures will be supplied by BSNL at stores. | 200 | per Joint | 2,399 ₹4,79,800 Lowest | 2,500 ₹5,00,000 |
| 6.00 | Providing and fixing RCC Joint protection chamber of 1.2M outer diameter with precast RCC rings /collars and RCC top & base covers as per standard design and drawing and filling the chamber with sand as per directions of Engineer in charge with the following details. i) Chamber consists of Precast RCC ring/collar of outer diameter 1.2M, 0.4M height and wall thickness of 50mm with concrete mix of 1 : 2: 4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) with necessary reinforcement as per standard approved design& drawing. | 100 | Nos | 2,999 ₹2,99,900 Lowest | 4,500 ₹4,50,000 |
| 7.00 | Supply of class B GI Pipe of 65 mm of 3.65mm thick @ 6.61 kg/m dia at work location inluding transportation wherever required as suggested by Engineer-in-charge | 550 | Per Meter | 678 ₹3,72,900 | 540 ₹2,97,000 Lowest |
| 8.00 | Providing and fixing precast reinforced cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size) Route/Joint indicator with indicator dimensions( 0.125m*0.125m*1.05m) & fixing in position in cement concrete (0.35*0.2*0.15) ,finishing smooth, and painting and lettering etc all as directed by Engineer in charge ( Each indicator is counted for payment). | 450 | Nos | 999 ₹4,49,550 | 850 ₹3,82,500 Lowest |
Tender Value
₹2.0 Cr
EMD Value
₹4.9 L
Closing Date
20 Nov 2023, 3:00 pmClosed
AGM(PLG),O/o GMBA,Sangareddy
AGM(PLG),O/o GMBA,Bypass Road,Sangareddy
UNDERGROUND OFC REHABILITATION WORKS FOR BACKHAUL STRENGTHENING OF BTS SITES UNDER 4G SATURATION PROJECT IN MAHABUBNAGAR OA UNDER SANGAREDDY BA
2023_BSNL_172521_1
GMBA/SGD/PLG / 4G SAT/ OFC REHAB/ 2023-24/11
Open Tender
Miscellaneous Services
Works
365 days
Mahaboobnagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,360
Yes
AO (CASH), BSNL,O/o GMTD,SANGAREDDY
₹4.9 L
Yes
16 Dec 2023
30 Oct 2023
21 Nov 2023
30 Oct 2023
20 Nov 2023
30 Oct 2023
30 Oct 2023 - 3 Nov 2023
Amount
Laying and Jointing PVC Pipe. Heading
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in trenches to a width of 0.30m to 0.45m and for a depth of 1.65m as specified in the Standard Laying practices for Cables including dressing of sides and ramming of bottoms, lift up to 1.65 m, including getting out the excavated soil and then refilling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc and disposal of surplus excavated soil as directed within a lead of 50 m(For All Kinds of Soil)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in trenches to a width of 0.30m to 0.45m and for a depth of 1.65m as specified in the Standard Laying practices for Cables including dressing of sides and ramming of bottoms, lift up to 1.65 m, including getting out the excavated soil and then refilling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc and disposal of surplus excavated soil as directed within a lead of 50 m(For Hard Rock Soil -Blasting Prohibited)
Laying OF PLB /HDPE PIPE 40-50mm dia coupled with sockets in the excavated cable trench as per the standard practices including loading, unloading, uncoiling and transportation from BSNL designated stores to site of work (Pipes, sockets will be supplied by BSNL at stores at no cost. Length of pipe laid is measured for payment
Blowing of OFC Cable in cable trench as per the standard practices including allied works like replacing/refixing couplers, Sealing of PLB ends and refilling sand ,refixing RCC covers and back filling in Joint chambers wherever required as per the directions of Engineer in Charge. (The rate includes loading, unloading, uncoiling and transportation of cables from BSNL designated stores to site of work.
Boring at a depth of 1.65m using HDD method /Boring/Cutting Black Top or Concrete Road at Road Crossing etc including excavating entry and exit pits & pushing PLB Pipes upto 3 Nos maximum, reinstatement of road and other all operations involved as per directions of Engineer in charge.(Length of Bore/ Length of reinstated road as the case may be is measured for payment)
Splicing of all the fibers of OF cable laid at every joint within specified splicing loss range (<=0.02dB) while testing with OTDR and making termination at the ends. All materials, Splicing Machine and labours except Joint Closer to be supplied by Bidder /Vendor). Joint Closures will be supplied by BSNL at stores.
Providing and fixing RCC Joint protection chamber of 1.2M outer diameter with precast RCC rings /collars and RCC top & base covers as per standard design and drawing and filling the chamber with sand as per directions of Engineer in charge with the following details. i) Chamber consists of Precast RCC ring/collar of outer diameter 1.2M, 0.4M height and wall thickness of 50mm with concrete mix of 1 : 2: 4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) with necessary reinforcement as per standard approved design& drawing.
Supply of class B GI Pipe of 65 mm of 3.65mm thick @ 6.61 kg/m dia at work location inluding transportation wherever required as suggested by Engineer-in-charge
Providing and fixing precast reinforced cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size) Route/Joint indicator with indicator dimensions( 0.125m*0.125m*1.05m) & fixing in position in cement concrete (0.35*0.2*0.15) ,finishing smooth, and painting and lettering etc all as directed by Engineer in charge ( Each indicator is counted for payment).
Iris Infra services private limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDERDOCUMENT.pdf
Tender Documents • 2.61 MB
BOQ_189008.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .