| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L1 | Accepted-AOC Lowest Quoted bidder. | |
| 2 | L2₹34.2 L+₹5.3 L (18.2%)Rejected-Finance | L2 | Rejected-Finance Higher quoted bidder. | |
| 3 | Rejected-Technical | - | Rejected-Technical No remark in WLR of of HQ CE Bareily Zone in WLR of Dec 2021. | |
| 4 | Rejected-Technical 38 BHARKATIYA JOSHI NEAR POST OFFICE JHULAGHAT ROAD PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262520 | - | Rejected-Technical Due to exceeding the limit of maximum work load. |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
30 Jun 2022, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
WELCOME MAINT TO OFFRS MD ACCN, DAY TO DAY ELECTRIC MAINTENCANCE AND INTERNAL WIRING OF CERTAIN BLDGS AND OTHER CONNECTED WORKS AT MIL STN DHARCHULA UNDER GE PITHORAGARH
2022_MES_527969_1
8478/DHR/E8
Open Tender
Civil Works
Item Rate
330 days
GE Pithoragarh
Class D, Category a(i)
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹94,000
Yes
26 Sept 2022
2 Jun 2022
2 Jul 2022
2 Jun 2022
30 Jun 2022
16 Jun 2022
Amount
DESCRIPTION OF ITEMS
Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) complete all as specified and as directed .
Taking down chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each complete all as specified and directed.
M&l preparation of old painted steel roof surfaces of corrugated / plain steel sheet of any description, over 10cm in width or girth, not otherwise described and applying one coat of antisol roof paint complete all as specified and directed.
M&L preparation of old previously treated wooden surface exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&l Preparation of plastered or unplastered old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soots, treating oily/greasy spots, moss and efflorescence and applying one coat of white wash including cornices etc complete all as specified and directed.
Ditto all as per Item No 10 above but on ceiling surfaces complete all as specified and directed.
M&l Preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed.
M&l for preparation of old plastered/cement based painted surfaces of walls by brooming down or steel wire brushing, scrapping down smike soots and efflorescence salts, removing nails and making good surfaces and applying one coat of cement base paint complete all as specified and directed.
M&L, preparation old, previously treated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&l for 10mm thick rendering in CM 1:6 on brick/concrete surfaces including finishing the surfaces fair and even complete all as specified and directed.
Preparation of new plastered surfaces and applying two coat of oil bound distemper over and including a layer of wall care putty to achieve a smooth finish surface (average thickness 2 mm) complete all as specified and directed.
S&F non-skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but n exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M & L joint free glazed ceramic coloured tiles 450x300x7mm thick on walls etc set & jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces over & incl 10mm thick rendering in cement mortar 1:4 for laying wall tiles etc complete all as specified and directed.
S&F factory made solid PVC door frames of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per specification & drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of M S tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain coloured PCV ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frame at site as per specification & drawings.
S&f 100mm butt hinges, medium weight, cold rolled mild steel, complete all as specified.
S&F 200mm aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S& F 150 mm extruded aluminum alloy handles, fabricated type anodised complete all as specified and as directed.
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing complete all as specified and directed.
S&F 15mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing complete all as specified and directed.
S&F 20mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
S&F in repairs 15 mm bore dia Stop/angle valves fancy type Chromium plated screwed down , high pressure , with capstone head, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&f in repairs Brass central hole wash hand basin mixer for mixing hot & cold water screwed doen for iron pipe and fixed.
S&F in repairs 15mm bore dia fancy type Bib taps chromium plated with capstone head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed .
S&f in repairs vitreous china wash hand basin white exclusive quality of size 550x400mm including brackets, PVC waste pipe and waste coupling fixed complete all as specified and directed.
S&f in repair chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs 600mm long PVC Connection 15mm size with PTMT nuts complete all as specified and directed.
S&F in repairs Brass chromium plated Tubular towel rail , 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&f in repairs vitreous china wash down water closet (pedestal pattern) complete, (excluding flushing cistern and flushing pipe) complete all as specified.
S&f in repair vitreous china squatting pan, orissa pattern, size 580mmx440mm white, with integral foot rests (excluding flushing cistern & flush pipe) including making good to disturbed floor with PCC complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 lits capacity low level, white, with inlet, ball valve, float and handle including brackets, flush pipe and connection to pipes complete all as specified and as directed.
S&f in repair toilet paper holder of brass chromium plated with flap complete all as specified and directed.
S&f in repair PVC grating 100mm dia of PTMT (minimum weight 250 gram) with wash hole complete all as specified and directed.
S&F PVC (SWR) bends 75 mm bore with or with out oval excess door complete all as specified and as directed
S&F PVC (SWR) bends 110 mm bore with or with out oval excess door complete all as specified and as directed
Demolition and breaking up drain pipes AC or PVC pipe 75mm internal dia, set in cement mortar complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and as directed.
E&M Portion: Taking down carefully Copper/Aluminium point wiring (Light ,fan, socket or power) complete, removing unserviceable or serviceable materials from site and making good the disturbed surface of walls, floors etc, complete all as specified and directed.
M&L for point wiring Concealed with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non- metallic PVC surface / concealed conduit 20 mm or higher dia, light grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, green in colour 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly , screwed with Brass screws, cup washers complete all as specified and directed for One light point/Fan point/bell point controlled by one, one way switch of 5/6 Amps complete all as specified and as directed.
Ditto all as per Item No 42 above but for one 3/5 pin socket outlet 5/6 Amp on same board with other switch of 5/6 Amp.
Ditto all as per Item No 42 above but for one 3/5 pin 5/6 amps socket outlet point on independent board controlled by one, one way switch of 5/6 amps on independent board.
M&L for point wiring Concealed with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non- metallic PVC surface / concealed conduit 20 mm or higher dia, light grade ISI marked complete with all PVC conduit accessories / fittings and 1st class hard wood (Shisham) terminal switch board of suitable size with 3mm thick plastic laminated hard glossy surface sheet top cover open recessed on all and brass screw and washer including continuous earth wire of PVC insulated, unsheathed, green in colour 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly , screwed with Brass screws, cup washers complete all as specified and directed for One light point/Fan point/bell point controlled by one, one way switch of 5/6 Amps complete all as specified and as directed.
Ditto all as per Item No 45 above but for one 3/5 pin socket outlet 5/6 Amp on same board with other switch of 5/6 Amp.
Ditto all as per Item No 45 above but for one 3/5 pin 5/6 amps socket outlet point on independent board controlled by one, one way switch of 5/6 amps on independent board.
M&l for power point wiring with 4 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC conduit of suitable size, in open surface type complete with all accessories/fitting and 1st class hard wood (Shisham) terminal switch board of suitable size with 3mm thick plastic laminated hard glossy surface sheet top cover open recessed on all and brass screw and washer including unsheathed single core PVC insulated cable green in colour 4 Sqmm multistranded copper conductor cable as earth wire and connecting to earth dolly complete all as specified and directed.
M&l for power point wiring with 4 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC conduit of suitable size, in open surface type complete with all accessories/fitting sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including unsheathed single core PVC insulated cable green in colour 4 Sqmm multistranded copper conductor cable as earth wire and connecting to earth dolly including making good disturbed surfaces complete all as specified and directed.
S & F in repairs Switch piano, flush type, white finish, 5/6 amps, single pole, one way all as specified and directed.
S&F in repairs Switch piano flush type, white finish, 15/16 amps, single pole, one way, complete all as specified and directed.
S&F in repairs Switch piano flush type, white finish, 5/6 amps, single pole, two way, complete all as specified and directed.
S&f in repairs socket outlet 3 pin 5/6 Amps flush type complete all as specified and directed.
S&F in repairs Socket outlet two in one 3 pin 5/6 amps and 3 pin 15/16 amps (multipurpose), flush type, non shutters, non inter locking type, complete all as specified and directed.
S&F in repairs ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed.
S&f in repairs bell push AC SP 240 volts flush type 5/6 Amps, single pole one way complete as all specified and directed.
S&f in repairs bell electric Ding Dong/Multi music type, AC, SP 240 volts, complete as all specified and directed.
S&f in repairs lamp holder PVC/poly carbonated type with back plate suitable for pendants/angular/batten fittings complete all as specified and directed.
S&f in repairs electronic fan regulator flush type stepped type on the existing phenolic laminated sheet complete all as specified and directed.
S&f in repair LED bulb 12 watts, 220V complete all as specified and directed.
S&f in replacement of 1x35 watt LED building security light fitting, with and including GI bracket made out of 1.5 mtr GI pipe bent to shape light grade of 40mm dia, bracket mounting clamps nut bolts etc and making electric connection with 3 core 1.5 sqmm PVC insulated copper conductor cable complete all as specified and directed.
M&l in repair for sub main wiring with 2 runs of 6 Sqmm and one run of 4 Sqmm copper cable multistranded drawn through existing surface/recessed steel/PVC conduit providing necessary clamp, screw, thimble and connected to MCB/DB box/main switches etc all as specified and directed.
S&f in repair LED lights fitting 1x18/20W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S&f in repair LED lights fitting mirro type with high out put diffuser 2 feet, 1x10W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S&f in repairs 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with an inner sheating of PVC tape and over all PVC sheathed in service connection susp[ended by insulating hangers not more than 1mtr aprat including 4mm dia GI suspension wire one twin core flat or circular stranded/solid conductor of size 10 Sqmm complete all as specified and directed.
Dismantling house service brackets, any type from existing position
M&l for house service bracket (hook type complete with 3.0 mtr long GI pipe 40mm dia med grade, two nos 90 degree bend, clamps, nuts and bolts, washers, MS hooks and stay all as required at site complete all as specified & directed.
M&l for dismantling old earthing and providing new earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in earth plate No 3 of MES schedule 2009 Part-I connected to earthing test point including earth continuity conductor and loop earthing etc as required 4mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in RCC 1:2:4 type B1 duly reinforced with 6mm dia bar @150c/c both ways including with lifting handle and earth lead and GI protection pipe light grade 15mm dia beyond 7.5 mtr from electrode to earth terminal point/main switch board and 20 mm bore GI watering pipe medium grade complete all as specified & directed.
Dismantling existing unserviceable energy meter by disconnecting electrical connections from board and depositing the same in AGE office store yard, and S&F two wire tamper proof electronic energy meter in polycarbonated body with LCD display in class 1.0 as per IS 13779/IEC 61036, IP-54, 50Hz, 240 Volts, AC, 2.5-30 Amps, single phase, 240 V on and including suitable size teakwood board complete all as specified and directed.
Dismantling existing unserviceable energy meter by disconnecting electrical connections from board and depositing the same in AGE office store yard, and S&F four wire tamper proof electronic energy meter in polycarbonated body with LCD display in class 1.0 as per IS 13779/IEC 61036, IP-54, 50Hz, 240 Volts, AC, 10-60 Amps, three phase, 415 V on and including suitable size teakwood board complete all as specified and directed.
Supply only tape roll insulation (1.8cmx6.5mx0.125mm) suitable for 1.1KV grade best quality, good adhesive as per sample held with AGE office complete all as specifed & directed.
S&F in repairs MCB DB sheet metal enclosure for DB, SPN, 8 way having protection with 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB's and isolators,concealed in wall complete all as specified and directed.
S&F in repairs MCB DB sheet metal enclosure for DB, SPN, 4 way having protection with 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB's and isolators,concealed in wall complete all as specified and directed.
Supply and Fix in repairs MCB single pole, 240 volts, 6-32 Amps of 10 KA complete all as specified and directed.
Supply and in repairs Fix MCB single pole & Neutral 240 volts, 40 amps, of 10 KA complete all as specified and directed.
Taking down ceiling fan from existing position, dismantling, overhauling and cleaning throughly, oiling /greasing and re-assembling after replacing split pins, check nuts, rubber seal etc and rehanging at same or new locations duly connected with new PVC three core flexible copper conductor cable of size 23/0.0076, complete testing all as specified and directed.
M&l for taking out brunt copper winding from ceiling fan of 1200mm size and rewinding with existing /same gauge of super enameled copper winding wire complete all as specified and directed.
Supply only ball bearing for ceiling fan after and including taking down old ball bearing complete all as specified & directed.
S & F in replacement Capacitor 2.5 mfd , ± 5%, 440V, AC, 50 Hz complete all as specified and directed.
M&l for painting with one coat of spray paint with white enamelled paint on external surface of ceiling fan of any size complete after duly preparation of the surface by rubbing with wire mesh, washing with soap water including filling cavities with filler, one complete including writing of MES number all as specified and directed.
Taking down exhaust fan of any size from existing position, dismantling, overhauling and cleaning throughly, oiling/greasing and re-assembling after replacing split pins, check nuts, rubber seal bushes etc and rehanging duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing all as specified & directed. Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below.
M&l for taking out brunt copper winding from exhaust fan of any size/type and rewinding with existing /same gauge super enameled copper wire complete all as specified and directed.
S & F in replacement Capacitor 4 mfd , ± 5%, 440V, AC, 50 Hz complete all as specified and directed.
M&l for painting with one coat of spray paint with grey/blue enameled paint on external surface of exhaust fan of any size complete after preparation of the surfaces by rubbing with wire mesh, washing with soap water complete including writing of MES number all as specified and directed.
Taking down carefully storage water heater of capacity 25/35/50 Ltr, dismantling inner tank and out tank, pipe assembly, cleaning thoroughly with descaling liquid compound complete to ensure free and constant flow of water through outlet, welding of inner tank if required at site, rethreading of inlet/outlet pipe 15mm dia, reassembling the same at eisting/new location including necessary fasteners to ensure proper safety as reqd at site, testing and commissioning after re-installation at site complete all as specified and directed. Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below.
Supply only thermostate fitting fitment varying capacity for 25/35/50 Ltr capacity geysers.
Supply only PVC connection pipe nylon threaded 15mm size with brass nuts coping in both end of length 600mm for geyers complete all as specified and directed.
Supply only heating element of 1.5/2.0 KW for geyser (as per sample ISI brand) including taking down old heating element complete all as specified and directed.
Taking down flat-plate solar collecter storage solar water heater of capacity upto 250ltr, dismantling inner tank and outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound complete to ensure free and constant flow of water through outlet, welding of inner tank if required at site, laser/ultrasonic welding for bonding fin and rise tube, repair of copper bracing for bonding of header and raise making leak proof, repair & replacement of back and side insulation material, rethreading of inlet/outlet pipe 20mm dia, reassembling the same after replacing u/s items i.e. heating element, thermostate, toughned glass, connection pipe with clamp etc at existing location including necessary fasteners to ensure proper safety as reqd at site, repair/welding of MS structure for collector stand, testing and commissioning after re-installation at site complete all as specified and directed. Note: Spare parts (heating element, thermostate, toughned glass, connection pipe with clamp) will be measured and paid separately under respective items as supply only as mentioned below.
Supply only heating element of 3.0 KW for solar water heater (as per sample ISI brand) including taking down old heating element complete all as specified and directed.
Supply only thermostat for solar water heater.
Supply only flat plate solar collecter transparent cover to prevent heat loss and made with iron proof solar safety toughened glass, 4mm thick with low iron, transmissivity upto 92% at near normal incidence glass as per existing complete all as specified and directed.
Supply only heavy duty nylon threaded flexible PVC/CPVC connection pipe 25mm dia suitable for both hot & cold water supply of solar water heater complete all as specified and directed.
Supply only GI/brass adjustable screw clamp as per sample
Supply, laying and testing GI pipe medium grade 15mm, ISI marked, with all fittings and fixed complete to wall and ceiling or laid on floors complete all as specified and directed.
Supply, laying and testing GI pipe medium grade 20mm, ISI marked, with all fittings and fixed complete to wall and ceiling or laid on floors complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing and re-fixing the same at new or old locations by replacing worn out GI fittings complete all as specified and directed. Note: GI fittings as required shall be measured and paid separately under respective items as supply only as mentioned below.
Supply only elbow 15mm
Supply only Tee 15mm
Supply only socket 15mm
Supply only Union 15mm
Supply only reducer socket 20/15mm
Supply only tank nipple 15mm
Supply only nipple 15mm
Supply only M Seal
Supply only butterfly valve 15mm
M&l in repair for sub main wiring with 2 runs of 4 Sqmm and one run of 4 Sqmm copper cable FRLS multistranded drawn through existing surface/recessed steel/PVC conduit providing necessary clamp, screw, thimble and connected to MCB/DB box/main switches etc all as specified and directed.
RAZA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .