Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance B G2 6B 107 RIDDHI SIDDHI APARTMENT GAYANS PARK TELEPHONE NAGAR INDORE DISTRICT INDORE MADHYA PRADESH 452001 | INDORE | INDORE | MADHYA PRADESH | 452001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹34.8 L
EMD Value
₹50,000
Closing Date
31 Jan 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Renovation of Acoustic Panel, Maintenance work of flooring, Replacement of Gallery seats, Electrification works
2024_SKF_712326_4
265/SKF/CE/2024-25
Open Tender
Civil Works - Others
Item Rate
120 days
Thiruvananthapuram
Please refer tender document
7 documents required · 7 mandatory
₹2,950
₹50,000
3 Feb 2025
23 Jan 2025
3 Feb 2025
23 Jan 2025
31 Jan 2025
23 Jan 2025
Amount
Renovation of Acoustic panel
od173649/2023_2024 : Dismantling of Existing Acoustic panels at all heights including the glass wool including the cost of removing cleaning the site of any dust ore residue and disposal of the same upto any dumping yards within 10 Kms lead complete all as per the directions of Engineer -in- charge
od173651/2023_2024 : Dismantling of existing maple wood flooring including wooden runners carefully without damages to those re-usable items including stacking the re-usable material up to lead of 50 m, complete as per the directions of engineer in charge.
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
15.39.2 : Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking with in 50 metres lead:Thickness above 10mm upto 25 mm
od173652/2023_2024 : Installation of departmentally supplied stitched Fabric panels of size 1200 x 1200 mm fixed on to existing aluminum framework by interlocking manner. cost of all materials including labour, accessories, and fixing charges complete as per the direction of Engineer in charge.
od173653/2023_2024 : Installation of departmentally supplied Calcium silicate perforated panels of size 600 x 600mm fixed on to existing aluminum framework by interlocking manner. cost of all materials including labour, accessories, and fixing charges complete as per the direction of Engineer in charge.
od173654/2023_2024 : Installation of departmentally supplied Groodved MDF panels fixed on to existing aluminum framework by interlocking manner. cost of all materials including labour, accessories, and fixing charges complete as per the direction of Engineer in charge.
od173658/2023_2024 : Providing and fixing vinyl flooring of 1.6 mm thick of approved color and texture for floor in to the level the floor surface using adhesive as per manufacture specification the rate is inclusive of all material, jointing, labour, lead, lift, wastage of material etc complete at all level as per the design or pattern approved by the Engineer in charge
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.66.1 : Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work
14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
Maintenance work of flooring
od178500/2023_2024 : Supply and Installation of Teak Wood Sports Flooring 25-30mm Thick x 150mm Width x Random Length including Pine Wood Runners 38mm x 63mm x Random length placed 30 cm Center to Center with Rubber Cushion Pads fixed beneath the runners 30cm Center to Center excluding finishing, complete as per directions of Engineer-in-charge.
od178513/2023_2024 : Sanding and re-finishing of Wooden Sports Flooring – Using High quality water-based filler used for gap filling between planks one coat of ware-based primer and two coats of water based Two Component DIN Certified FIBA approved coatings as top coat Top coat Finish has to meet EN 14904 DIN 18032-2 for slip resistance and EN 13501-1 Abrasion wear resistance for the finish should not be more than 20-22mg in TABER test
od174637/2023_2024 : Game line marking for badminton/basketball courts with two or more coats of single component polyurethane water based paint with a coverage of 80-100 g/m2. The courts and line should be marked with a suitable lining tape pressed firmly to the floor to ensure unnecessary bleeding of the paint in to the courts, and tapes should immediately removed after the application of the paint.The line marking should then be sanded with grit paper and should be done before the final coat wooden floor polish.
od204129/2023_2024 : Badminton Nets- Supply and Installation of Yonex badminton nets to poles, all cost including transportation charges etc Prior approval should be taken.
Replacement of Gallery Seats
100.98.1002 : Engaging Blacksmith Ist class
od175395/2023_2024 : Stadium Seat .The chair has Plastic Seat with Back Rest Support.The body section is mounted on legs Round or square Tube Stable Base. The colour is decided as per the engineer in charge.
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
100.98.1005 : Engaging Carpenter 2nd class
100.98.1008 : Engaging Coolie
Electrification works
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.6 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
od178341/2023_2024 : SKF OD - supply and installation of RJ 45 connector
od178342/2023_2024 : SKF OD- supply and installation of 5 port POE switch,67 watt, make Tenda,TP link, Dlink or approved by engineer incharge
od178343/2023_2024 : SKF OD-supply of 4 U wall mount rack with all accessories, rack should be manufactured out of steel sheet punched formed welded and powder coated ,should have 100% assured compactability with all equipment
od178344/2023_2024 : Supply and installation of OFC Module/Media convertor Features Dual data-rate of 1.25Gbps/1.063Gbps operation 1550nm DFB laser and PIN photo detector for 40km transmission Compliant with SFP MSA and SFF-8472 with single LC receptacle Digital Diagnostic Monitoring: Internal Calibration or External Calibration Compatible with SONET OC-24-LR-1 Compatible with RoHS Refer Annexure 1 for detailed specification.& Approved Makes- NETGEAR/Juniper/ Allied Telesis (MAF Required)
od178345/2023_2024 : Supply and installation of Single shutter faceplate Single with SMB Box in recess/on surface and making good the damages, colour washing etc as requiredType : British Style Standard Face Plate , Dimensions : 86 mm X 86 mm , Material : VE10ABS , Compatible For UTP & STP , Labelling Facility( Data voice, Fax, Video) , ROHS Complaint , 25 Years Warranty\ Approved Makes- Commscope/Molex/ R& M
od178346/2023_2024 : Supply and laying of 12 core OFC cable with all accessories
90.3.22.4 : Supply & installation of light fittings on flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. 1200mm 2x20W LED lamp with box type fixture
od178644/2023_2024 : SKFDSROD: Supply and installation of pre-wired 20W LED batten fitting complete with all accessories and tube etc directly on ceiling/wall, including connection with PVC insulated,copper conductor single core cable and earthing etc as required. (Make: Phillips, Crompton greaves, Bajaj, Lucker or Approved by engineering in charge)
2.4.4 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4+12), Double door
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB /Isolator6 way, Double door
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 6 sq mm with factory made clamp
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
od178508/2023_2024 : SKFOD_ Supply and fixing SINTEX Box (150mmx150mmx100mm) or nearest size including connector, MCB Rail and neutral links for giving connections including all accessories complete as required
90.4.10 : Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
od178559/2023_2024 : SKF OD-Supply conveyance installation testing and commisioning of 250 mm exhaust fan working on 230 v single phase AC,BLDC technology 20 W, 1150CMPH plastic blade make of atomberg or similiar approved by engineer in charge
od178560/2023_2024 : SKF OD- Supply conveyance installation testing and commissioning of 36 inch 900 mm,1200 W,minimum 700 rpm speed, 4 blade industrial exhaust fan working on three phase 50 Hz AC supply,made upof Almonard, Crompton or same approved by the engineer in charge
od178593/2023_2024 : Dismantling of mimic panel and its related accessories
od178594/2023_2024 : SKF OD-SUpply conveyance and installation of Aluminium foil flexible type 50mm to 500 mm sizes and Temperature range -30oC to +100oC Approx,No toxic gasses release at high temperature on fire,Light weight , heat resistant flame resistant , low noise approved by the engineer middot;
JKM CONSULTANT (BID ID -2084784)
Bidder Name
JKM CONSULTANT
INFRA CARE
stage.html
html • 0.02 MB
finance_1163252.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .