80247 PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR SAILORS (LDGS AND BELOW) AT NAVAL STATION, KOLKATA
2026_MES_756057_1
80247/CE(CG)/E8
Open Tender
Civil Works
750 days
Kolkata
Class SS
Category a (i)
8 documents required · 8 mandatory
₹3,000
Yes
Garrison Engineer (I) (CG and N) Kolkata
₹15 L
Yes
12 Mar 2026
12 Mar 2026
23 Jun 2026
1 May 2026
16 Jun 2026
9 Jun 2026
Schedule "A" Part – I to Schedule "A" Part – XIII: NOTE: Schedule "A" Part – I to Part – XIII are pre-priced by MES. Bidders shall insert their Lump sum amount in Green coloured field under Column - 6 only
Lump sum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I
Lump sum price worked out by the contractor for "EARTH WORK AND SITE CLEARANCE", as listed in Schedule "A" Part – II
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – III
Lump sum price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", as listed in Schedule "A" Part – IV
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – V
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY, LIFT & DG SET", as listed in Schedule "A" Part – VI
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VII
Lump sum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VIII
Lump sum price worked out by the contractor for "ROAD, PATH & CULVERT", as listed in Schedule "A" Part – IX
Lump sum price worked out by the contractor for "FIRE FIGHTING, FIRE DETECTION AND FIRE ALARM SYSTEM", as listed in Schedule "A" Part – X
Lump sum price worked out by the contractor for "LIGHTNING PROTECTION", as listed in Schedule "A" Part – XI
Lump sum price worked out by the contractor for "PILE FOUNDATION", as listed in Schedule "A" Part – XII
Lump sum price worked out by the contractor for "DEMOLITION/ DISMANTLING", as listed in Schedule "A" Part – XIII
Schedule "A" Part - XIV: [Miscellaneous Items] [Internal Water Supply; Internal Electric Supply; External Water Supply; External Electric Supply, Lift & DG set; Sewage Disposal; Area drainage; Road, Path & Culvert; Fire fighting, fire detection & fire alarm system; Pile foundation; Demolition/ Dismantling]
Extra over CPVC pipes for 80mm inner dia tank adapter with brass insert
S&F gun metal globe or gate valve of 65mm bore conforming to IS 9338, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Sink cock, 15mm bore, cast copper alloy, chromium plated with regular swinging spout, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed.
S&F LED bulb 9 Watt, with not less than 770 lumen output fixed complete
M&L for street light bracket made of GI pipe medium grade 32mm dia, appx 1.20 m long bent to shape suitable for fixing street light fixed to pole with 2 Nos of MS FI brackets with nuts and bolts complete including painting with two coats of aluminium paint over a coat of zinc chrome primer all as specified and as directed
Supply & fixing RJ-45 data socket
S&F sheet steel powder coated distribution board Vertical type TPN 4 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting 4 pole MCCB up to 160 Amps as incomer and MCBs as out going complete fixed flush to the wall surface all as specified and as directed. [Note: MCCB & MCBs shall be measured and paid separately]
S&F blank plate PVC in lieu of MCB, modular switch, Socket etc
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 15 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete including 15mm dia PVC connections for Hot & Cold water all as directed.
Supply and install open well horizontal type submersible pump of discharge capacity 625 LPM/ 0.01125 cum / sec at 50 mtrs Head, 3 phase, 415 volt complete all as specified and directed. Note: Rate quoted includes for adequate PCC platform of height not less than 0.6mts, foundation bolts and nuts as required as per OEM recommendations
Supply & install Chemical Dosing system, plunger type suitable to inject solution up to 25 LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank of 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anti-corrosive painted complete with Chemical grade PVC NRV and suitable Valve connected to water pipeline with all fitting arrangements complete all as specified and directed.
Supply, installation, testing and commissioning floor mounted indoor LT panel. The Panel shall be made out of 2.0 mm thick MS CRCA sheet and angle iron structure 40 x40 x6 mm, CPRI approved compartmentalized type of size as required including locking arrangement and 2 coat of powder coated paint over a coat of red oxide metal primer, fixed in floor with MS angle iron 40x40x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including suitable size copper FRLS/HRFR copper wired connection, brass glands for cable entry etc complete all as specified for and including the following accessories:
(i) 3 phase 4 wire copper bus bar 200 Amp rating, insulated with colour code for main supply. (ii) RYB LED indicator for main supply-01 Set (iii) Digital Ammeter 3 phase 0-100 Amps for mains - 01 set (iv) Digital Voltmeter 3 phase 0-500 Volt for mains - 01 set INCOMING: MCCB 4 pole, 415V, 125 Amps rating 25KA breaking capacity - 02 No for two incoming (one mains and other DG supply. OUTGOING: (i) MCB TPN, C series, 40 Amps - 02 Nos for pumps (ii) MCB SPN , C series , 16 Amps - 01 No for spares (iii) Submersible pump controller star-delta starter suitable for 3 ph 15 HP including metering, indication and push button - 02 sets for pumps (iv) On load change over switch 63 Amps, 4 pole - 01 No
Supply and fixing of water pressure gauge 0-7 kg/cm²
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia
Supply and fix CI foot valve 150mm dia, flanged type conforming to IS 4038, complete with jointing materials all as specified and directed.
Supply, laying and testing copper conductor cable Flat type 10.0 sq.mm, 3 core for submersible pump all as directed.
Supply, Installation, testing & commissioning of 11 KV Compact Sub Station with non extensible RMU consisting of 1 No manually operated 11 KV/630 Amps VCB in SF6 insulated stainless enclosure, HT Cable/Bus bar, 1 No transformer 500 KVA, 11KV/433 CRT dry type & associated LT devices (ACB/MCCB/bus bar/Cable). Outdoor type enclosure having modular construction of 1.6/2.0 mm GI sheet steel. The enclosure shall have IP 54 degree of protection for HT & LT compartment & IP 23 degree of protection for Transformer compartment. The enclosure exterior shall be painted with epoxy based powder coated paint ( colour RAL 7032 ). The bottom base frame shall be welded and black painted Channel structure with lifting arrangement for the completely assembled CSS. Each compartment is provided with door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. The Transformer compartment is provided with Limit switch to trip the HT Switchgear, in case the Transformer compartment door is inadvertently opened in LIVE condition
HT SECTION: (i) SF6 gas insulated Compact VCB: Sheet steel enclosed, free standing, indoor mounted, 11 kV, 630A, 21kA/3s, 1-Way Non - extensible RMU, consisting of 1 No direct cable connection arrangement suitable to terminate 300 Sq.mm cable and 1 No. fixed VCB (Manual charging & closing) in series with LBS between VCB and Transformer, mechanical ON/OFF indicator, trip coil, Manual Close & Trip PB, live cable indicator, mechanical interlocks, pad locking facility, SF6 gas manometer, cable boots. (ii) CTs ratio: 60/1A, 2.5VA, CL: 5P10 for Protection. (iii) Self Powered Relay 3 O/C + 1 E/F ( 50, 50N, 51, 51N) Numerical IDMT + DMT+ Inst Relay Operating Handle (iv) The scope of item includes for Cable connection arrangement from outgoing of HT section to primary of Transformer by 11kV (E) XLPE armoured 3C x 240sq.mm. alumminium cable along with heat shrink cable kit, termination kits, lugs , glands etc required for Cable termination complete
TRANSFORMER SECTION: Transformer Dry type 500KVA, 6/0.433KV DYn11 Cast resin Dry type transformer with Off Circuit Tap Link having tapping range of +5% to -5% in steps of 2.5%, Z% : 4% (IST), with No load Loss - 1.5kW (IST) & Load loss at 75ⷪ C - 5.8kW (IST), Class F insulation, temp rise : 90°ⷪ C , 3nos. Surge arrestors 9kV 10kA polymeric, 1 no. Digital WTI with Alarm & Trip contacts. LT SECTION: (i) Aluminium PVC sleeved Bus bar from transformer Secondary to LT Section ( 100% for phase & 50% for N, Current density - 1A/ sq mm) (ii) ACB 800A, MDO, 4P, 50 KA , with Microprocessor based release with LSIG protection (iii) Tape wound LT CT ratio: As Req./5A, 15VA, Cl: 1 (iv) Digital Multifunction Meter, Cl: 1.0 (v) Indicating Lamps for, R,Y,B, ON, OFF, TRIP (vi) Bottom Cable termination arrangement of adequate size and qty for outgoing LT cable termination. Cable, lugs, glands etc required for Cable termination also included in the scope of this item.
Bus Bar : (i) EARTH Bus bar Aluminium size 50 x 6 sq mm,(ii) Aluminium bus from Transformer neutral up to exit point on CSS (iii) Misc item - Lugs, Terminals, Heaters, CFL, Sleeve, insulator (iv) Hardware ,locks, handle, gasket, tie rods and other bought out items. Note: Rate quoted by bidder for CSS shall be deemed to be inclusive of fwg:-. (i) PCC platform of height 1 mtr and area as recommended by OEM shall be provided. (ii) Aux. Supply of 230V AC will be made available at one point in CSS. (iii) Routine Tests as per IEC 62271-202 on the CSS like : a) Voltage test b) Functional test c) Verification of correct wiring. For items like Transformer, RMU and ACB, the contractor shall furnish the manufacturer’s routine Test Certificates.
Supply and install 150 KVAR APFC panel with MD-XL capacitor and MCCB as incomer with 6 steps (2x12.5 + 3x25 + 1x50) including all fittings complete all as specified and as directed.
Supply, installation, testing and commissioning floor mounted indoor LT panel. The Panel shall be made out of 2.0 mm thick MS CRCA sheet and angle iron structure 40 x40 x6 mm, CPRI approved compartmentalized type of size as required including locking arrangement and 2 coat of powder coated paint over a coat of red oxide metal primer, fixed in floor with MS angle iron 40x40x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including suitable size copper FRLS/HRFR copper wired connection, brass glands for cable entry etc complete all as specified for and including the following accessories:
(i) 3 phase 4 wire copper bus bar 945 Amp rating, insulating with colour code for main supply. (ii) RYB LED indicator for main supply-06 Sets (iii) Digital Voltmeter three phase 0-500 Volt - 01 No (iv) Digital Ammeter three phase 0-400 Amps - 06 Nos (v) multifunction meter for main supply- 01 No INCOMING : (i) MCCB 630 Amps, 35 KA Microprocessor release, 415 Volt, 50HZ, AC, 04 pole - 01 No OUTGOING : (i) MCCB 400 Amp, 35 KA, 415V, AC, 50Hz, 4 pole, thermal release -01 No. (ii) MCCB 320 Amp, 415V, AC, 50Hz, 4 pole, 35 KA, thermal release -01 No. (iii) MCCB 250 Amp, 415V, AC, 50Hz, 4 pole, 35 KA, thermal release -01 No. (iv) MCCB 100 Amp, 415V, AC, 50Hz, 4 pole, 25 KA, thermal release -02 No.
Supply, installation, testing and commissioning floor mounted indoor LT panel. The Panel shall be made out of 2.0 mm thick MS CRCA sheet and angle iron structure 40 x40 x6 mm, CPRI approved compartmentalized type of size as required including locking arrangement and 2 coat of powder coated paint over a coat of red oxide metal primer, fixed in floor with MS angle iron 40x40x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including suitable size copper FRLS/HRFR copper wired connection, brass glands for cable entry etc complete all as specified for and including the following accessories:
(i) 3 phase 4 wire copper bus bar 525 Amp rating, insulating with colour code for main supply. (ii) RYB LED indicator for main supply-01 Sets (iii) Digital Voltmeter three phase 0-500 Volt - 01 No (iv) Digital Ammeter three phase 0-400 Amps - 01 Nos INCOMING: (i) MCCB 350 Amps, 36 KA Adjustable type, 415 Volt, 50HZ, AC, 04 pole - 01 No + 01 No spare OUTGOING: (i) MCCB 100 Amp, 16 KA, 415V, AC, 50Hz, 4 pole, thermal release -11 No.
Supply and fix FRP street light pole box of minimum internal size - 300 x 200x 105 mm, with DIN Rail for MCB.
Supply and fix LED bollard light 10 watt with IP 65 protection of approved pattern including all necessary fixing arrangement.
Supply and fix LED Solar aviation light 6 watt including all necessary fixing arrangement.
Cutting of existing bituminous/ concrete road/ hard standing for laying LT UG cable/ GI pipe complete including returning, filling, ramming and providing 150mm thick PCC on top surface complete all as directed. (Quantity of cutting shall be measured for payment)
Supply and fix Zinc plated MS Bracket made of 40-50 mm dia MS pipe medium grade 1.5mtr long suitable for street light to be fixed on steel / RCC pole as per site requirement including suitable GI nut, bolt and clamps complete accessories all as specified and directed.
Design, supply, install, testing and commissioning of electrically operated 08 passengers Lift (544 Kg) in the existing lift well, speed 1.5 metre/sec, lift with single speed motor (Gearless machine) of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve Stilt + 10 upper floors i.e. with 11 stops and 11 landings with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding stainless steel door with moon rock finish of 16 gauge with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door), complete all as specified and directed.
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity: electrically operated Passenger elevator for 08 persons (544Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel to serve S+10, (opening on same side). (v) Existing well size: 1900 mm x 1900 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: Shall be as per relevant IS specifications. (viii) Car enclosure: Stainless steel panel body of 16 gauge with moon rock finish, Car frame floor integrity to be ensured. SS false ceiling (hairline finish) and stainless steel handrail of standard dia and size with hair line finish and splinter proof mirror of 4mm thickness in front half of the lift car.
(ix) Flooring: Polished granite flooring. (x) Electric light: LED Light fitting (Min 04 Nos). (xi) Fan: Fresh Air fan 380mm sweep – 01 No. (xii) Car entrance: Automatic, centre opening, sliding doors. (xiii) Clear opening: Not less than 900mm x 2000mm high. (xiv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12 mm thick. (xv) Control: Simplex full collective with and without attendant. (xvi) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors. (xvii) Main drive and control shall be latest, high efficient and low power consumption.
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time adjustable from (0-30 Sec). (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvii) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Indoor communication to be connected with nearest security post.
(c) ADDITIONAL FEATURES (i) Automatic rescue device.: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system: Each floor shall be provided with announcement system.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light. (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call register indicator in all landings. (x) Attendant operation system in car panel.
Design, supply, install, testing and commissioning of electrically operated 13 passengers Lift (884 Kg) in the existing lift well, speed 1.5 metre/sec, lift with single speed motor (Gearless machine) of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve Stilt + 10 upper floors i.e. with 11 stops and 11 landings with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding stainless steel door with moon rock finish of 16 gauge with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door), complete all as specified and directed.
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity: electrically operated Passenger elevator for 08 persons (544Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel to serve S+10, (opening on same side). (v) Existing well size: 2000 mm x 2500 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: Shall be as per relevant IS specifications. (viii) Car enclosure: Stainless steel panel body of 16 gauge with moon rock finish, Car frame floor integrity to be ensured. SS false ceiling (hairline finish) and stainless steel handrail of standard dia and size with hair line finish and splinter proof mirror of 4mm thickness in front half of the lift car.
(ix) Flooring: Polished granite flooring. (x) Electric light: LED Light fitting (Min 04 Nos). (xi) Fan: Fresh Air fan 380mm sweep – 01 No. (xii) Car entrance: Automatic, centre opening, sliding doors. (xiii) Clear opening: Not less than 900mm x 2000mm high. (xiv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12 mm thick. (xv) Control: Simplex full collective with and without attendant. (xvi) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors. (xvii) Main drive and control shall be latest, high efficient and low power consumption.
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time adjustable from (0-30 Sec). (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvii) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Indoor communication to be connected with nearest security post.
(c) ADDITIONAL FEATURES (i) Automatic rescue device.: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system: Each floor shall be provided with announcement system.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light. (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call register indicator in all landings. (x) Attendant operation system in car panel.
Supply, install, testing and commissioning MCCB 63 Amps capacity 36 KA short circuit capacity, 4 pole for main distribution power supply of each floor end feed unit with suitable size of enclosure made of 1.5mm thick sheet steel duly painted with powder coating on existing bus bar system complete with rotary operating handle, interconnection earthing etc.
Supply, install, test and commissioning of acoustic proof AMF type diesel engine driven generating set fully wired, 415V, +5%, AC 3 phase, 4 wire, 50 Hz having capacity 58.5 KVA continuous rating power factor 0.8 (lagging), connecting as per IE rules and mounted on a common base plate with anti vibration pad recommended by the manufacturer all as specified and directed .The DG set shall comprise of following :- . The diesel engine will comprise of following:- (A) Diesel Engine - The engine should be four cylinder, liquid cooled, turbocharged with after cooler, developing 74 HP @ 1500 RPM inline, electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 10002, ISO-3046, BS 5514 standard. Diesel Engine will comply with present CPCB -IV+ norms with following:
1. Dry type air cleaner 2. Exhaust silencer suitable for canopy 3. Expansion bellow 4. Lube oil cooler 5. Lube oil filter 6. Fuel filter 7. Radiator with pusher type fan and mounting 8. In-line mono block fuel injection pump 9. Electronic governor and fuel feed pump 10. Flywheel with starter ring and bell housing suitable for close coupling 11. Electric starter motor 12 Volt 12. Battery charging alternator 13. Microprocessor based controller fixed in power panel 14. Protection system for Low lube oil pressure, high water temperature (B) Alternator, The alternator shall be designed for an output of 58.5 KVA suitable for continuous operation rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3Ph in SPDP enclosure, self excited & self- regulated, Brush less, floor mounted with Ball or Bearing on end shields. The alternator conforms to IS : 4722, BS EN 60034-1 & will be suitable for tropical condition.
(C) Electric system : The electric system of the starter motor and charging alternator shall have the following components:- (i) Charging alternator 12V or 24V, DC (ii) Voltage regulator built in type IC regulated (iii) Starter motor 12 volts DC/24V DC (iv) Battery 12 volts DC and suitable capacity and quantity as per OEM standards with one set of connecting leads of suitable size copper cable. (D) Fuel tank (Service tank) : The fuel tank shall be mild steel suitable to hold fuel for minimum 8 hours or running at Full load and shall be including fuel level indicator duly marked to read 25%, 50%, 75%,100% per division fuel line from tank to engine arrangement for fuel filling fuel and digital display and drain out facility etc. complete all as specified.
NOTE:- a) Design and drawings of the DG set shall be prepared as recommended by the OEM. The same shall be got approved from GE before commencement the work and the rate quoted is deemed to include for the same. (b) Commissioning of the DG will be done by OEM service and at the time of commissioning minimum 25 % fuel to be present in tank for testing purpose and cost of same to be included in the quoted unit rate. (c) Design and drawings of the foundation shall be prepared as recommended by the OEM and be got approved from GE before commencement the work and the rate quoted is deemed to include for the same. (d) Design and drawings to be submitted along with a copy to the Accepting Officer after obtaining the approval of GE. (e) PCC platform of height not less than 0.6 mtr and area as recommended by OEM shall be provided and rate quoted shall be deemed to be inclusive of all.
Supply, installation, testing and commissioning floor mounted out door LT panel. The Panel shall be made out of 3.15 mm thick MS CRCA sheet and angle iron structure 40 x40 x6 mm, CPRI approved compartmentalized type of size as required including locking arrangement and 2 coat of powder coated paint over a coat of red oxide metal primer, fixed in floor with MS angle iron 40x40x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including suitable size copper FRLS/HRFR copper wired connection, brass glands for cable entry etc complete all as specified for and including the following accessories:
(i) 3 phase 4 wire copper bus bar 200 Amp rating, insulating with colour code for main supply. (ii) RYB LED indicator for main supply-04 Sets (iii) Digital Voltmeter three phase 0-500 Volt - 01 No (iv) Digital Ammeter three phase 0-400 Amps - 04 Nos (v) multifunction meter for main supply- 01 No INCOMING : (i) MCCB 125 Amps, 35 KA Microprocessor release, 415 Volt, 50HZ, AC, 04 pole - 01 No OUTGOING : (i) MCCB 63 Amp,16 KA, 415V, AC, 50Hz, 4 pole, thermal release -01 No for Bldg common area load. (ii) MCCB 63 Amp, 415V, AC, 50Hz, 4 pole, 16 KA, thermal release -03 Nos for lift load -03 Nos (iv) MCB TPN 63 Amps -02 nos for water supply installation (v) MCB SPN 6-32 Amps C series -01 No For Ext lightings (v) Automatic street timer system with MCB, 6-32Amp SPN, and ML2 type contractor-01 set for street light control.
S&F heavy duty (20 MT) RCPC manhole cover 500mm dia with collar, 75mm thick fixed in position all as directed
Supply and fixed 600 mm x 450 mm x 75mm thick precast RCPC perforated drain cover slab of 2 MT load bearing capacity with embossing RCPC 2MT fixed in position complete all as specified and as directed
M&L for applying evenly a priming/ tack coat with bitumen emulsion RS-1 at 10 kg per 10 sq.m with mechanical sprayer complete all as specified and as directed by the Engineer-in-Charge.
M&L for applying evenly a priming/ tack coat with bitumen emulsion RS-1 at 5 kg per 10 sq.m with mechanical sprayer complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing & commissioning of cable for fire detection and alarm system with 2 core annealed tinned copper conductor PVC sheathed, flexible, unarmoured cable 1.5 sq.mm all as specified in existing conduit complete as required.
S&F Rigid metallic conduit 25mm bore fixed to walls/ ceilings/ floors etc exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
S&F Cast Iron/ pressed steel terminal boxes 60mm deep with 3mm thick plastic laminated sheet cover of size 100mm X 100 mm complete all as directed.
S&F MS cabinet (size approx 750mm x 600mm x 450mm) for housing fire brigade inlet connections, fabricated from 16 gauge CRCA sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as directed.
S&F fire extinguisher ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS :15683 :2006 (Old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosives, Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224, high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, suitable for operating between 30° centigrade to + 55° centigrade, Fire Rating Class - 138.
S&F stored pressure fire extinguisher ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class "A", "B", "C" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammonium phosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30° centigrade to + 55° centigrade, Fire Rating Class - 1A & 13B
S&F Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO2 gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between 30° centigrade to + 55° centigrade, Fire Rating Class - 3A & 34B
Supply, installation, testing and commissioning floor mounted indoor LT panel. The Panel shall be made out of 2.0 mm thick MS CRCA sheet and angle iron structure 40 x40 x6 mm, CPRI approved compartmentalized type of size as required including locking arrangement and 2 coat of powder coated paint over a coat of red oxide metal primer, fixed in floor with MS angle iron 40x40x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including suitable size copper FRLS/HRFR copper wired connection, brass glands for cable entry etc complete all as specified for and including the following accessories:
(i) 3 phase 4 wire copper bus bar 600 Amp rating, insulating with colour code for main supply. (ii) RYB LED indicator for main supply-04 Sets (iii) Digital Voltmeter three phase 0-500 Volt - 01 No (iv) Digital Ammeter three phase 0-400 Amps - 04 Nos (v) Multifunction meter for main supply- 01 No INCOMING : (i) MCCB 400 Amp, 35 KA, 415V AC, 50Hz, 4 pole, thermal release -02 Nos for two incomer OUTGOING : (i) MCCB 320 Amp, 35 KA, 415V, AC, 50Hz, 4 pole, thermal release -01 No for main fire fighting pump. (ii) MCCB 100 Amp, 415V, AC, 50Hz, 4 pole, 25 KA, thermal release -01 No for jockey pump. (iii) MCB TPN 6-32 Amps C series-01 No (iv) MCB SPN 6-32 Amps C series -01 No (v) On load Change over switch 400 Amps - 01 No (vi) FASD motor starter 125 HP - 02 No (vii) FASD motor starter 25 HP-01 No
The panel shall have necessary control circuits interlinked with main fire detection panel for automatic starting and stop facility for the main fire pumps, sprinkler system. The jockey pump shall be provided with auto start and stop pneumatic/ electronic control so as to maintain 6 Kg/sq.cm pressure all the time in fire fighting pipe line and electronic controls so as to maintained 6 Kg/ sq.cm pressure all the time in fire fighting pipe line and electronic inter linking with main fire pumps for working under pre set conditions as desired. Main fire pump shall have auto start and manual stop facility with suitable star star delta auto starter having electrical interlocking arrangements and pneumatic / electronic time delay of suitable current rating and single phasing preventers.
Taking down high/ low level flushing cistern of any capacity including flush pipe complete
Taking down Exhaust fan of any type/ sweep, including disconnecting and sealing cable end and removing fan to store
Taking down unserviceable electrical DBs/ MCCBs/ AC starter/ Power unit of any rating by disconnecting the cable connections complete all as directed.
Taking down Window/ Split Air conditioner of any capacity from its installed position and handingover to MES stores
Taking down sub main wiring of any size/ type complete all as directed
M&L for Boring for Bored cast -in-situ piles 500mm dia in any strata except hard rock using DMC method (Direct mud circulation) and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed.
M&L for Boring for Bored cast -in-situ piles 750mm dia in any strata except hard rock using DMC method (Direct mud circulation) and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed.
M&L for Boring for Bored cast -in-situ piles 900mm dia in any strata except hard rock using DMC method (Direct mud circulation) and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed.
Carrying out initial load testing on 500mm dia piles of 26m depth and as per safe design load capacity indicated on the drawing, for following test all as per IS 2911 Part-IV complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out routine load testing on 500mm dia piles of 26m depth and as per safe design load capacity indicated on the drawingon, for following test all as per IS 2911 Part-IV complete all as specified and as directed:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out low strain integrity testing on 500mm dia bored cast-in-situ piles all as per ASTM D 5882 complete all as specified and as directed.
Carrying out dynamic load test to ascertain pile capacity on 500mm dia pile of 26m depth by pile driving analyzer (PDA) all as per IS complete all as specified and as directed.
Carrying out dynamic load test to ascertain pile capacity on 750mm dia pile of 26m depth by pile driving analyzer (PDA) all as per IS complete all as specified and as directed.
Carrying out dynamic load test to ascertain pile capacity on 900mm dia pile of 26m depth by pile driving analyzer (PDA) all as per IS complete all as specified and as directed.
Carrying out initial load testing on 500mm dia piles of 23m depth and as per safe design load capacity indicated on the drawing, for following test all as per IS 2911 Part-IV complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out routine load testing on 500mm dia piles of 23m depth and as per safe design load capacity indicated on the drawingon, for following test all as per IS 2911 Part-IV complete all as specified and as directed:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out initial load testing on 750mm dia piles of 26m depth and as per safe design load capacity indicated on the drawingon, for the following test all as per IS 2911 Part-IV complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out routine load testing on 750mm dia piles of 26m depth and as per safe design load capacity indicated on the drawingon, for the following test all as per IS 2911 Part-IV complete all as specified and as directed:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out low strain integrity testing on 750mm dia bored cast-in-situ piles all as per ASTM D 5882 complete all as specified and as directed.
Carrying out initial load testing on 900mm dia piles of 26m depth and as per safe design load capacity indicated on the drawingon, for the following test all as per IS 2911 Part-IV complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out routine load testing on 900mm dia piles of 26m depth and as per safe design load capacity indicated on the drawingon, for the following test all as per IS 2911 Part-IV complete all as specified and as directed:
A) Compression test (Vertical load test)
B) Pull out test
C) Lateral test
Carrying out low strain integrity testing on 900mm dia bored cast-in-situ piles all as per ASTM D 5882 complete all as specified and as directed.
Use and waste of driving MS temporary liner of minimum 8mm thickness for bored cast-in-situ piles of 500mm dia up to a depth of 18m and removing the liner carefully after casting of concrete using necessary T&P like vibro hammer, crane, slings etc complete including all fabrication work all as directed.
Use and waste of driving MS temporary liner of minimum 8mm thickness for bored cast-in-situ piles of 750mm dia up to a depth of 18m and removing the liner carefully after casting of concrete using necessary T&P like vibro hammer, crane, slings etc complete including all fabrication work all as directed.
Use and waste of driving MS temporary liner of minimum 8mm thickness for bored cast-in-situ piles of 900mm dia up to a depth of 18m and removing the liner carefully after casting of concrete using necessary T&P like vibro hammer, crane, slings etc complete including all fabrication work all as directed.
Schedule "A" Part - XV: Manning & Operation and Comprehensive maintenance of lifts
Outsourcing of services for operation of the following Electrically operated Lifts installed in one building with S+10 upper floors by deploying 01 operator (Semi skilled) per shift of 08 hours for 3 shifts/ day complete during 1st year of Defect Liability Period: (i) 02 lifts of 8 passenger (544 kg) capacity (ii) 01 lift of 13 passenger (884 kg) capacity
All as per Item No. 81 herein before but during 2nd year of Defect Liability Period.
All as per Item No. 81 herein before but during 1st year after expiry of Defect Liability Period.
All as per Item No. 81 herein before but during 2nd year after expiry of Defect Liability Period.
All as per Item No. 81 herein before but during 3rd year after expiry of Defect Liability Period.
Comprehensive maintenance including periodical maintenance of electrically operated Passengers/ Goods lifts catered under Item No. 39.00 & 40.00 herein before, during 1st year after Defect Liability Period as per OEM recommendation, repairs/ rectification of defects including renewal/ replacement of all defective parts through respective OEM of the lifts complete all as specified and as directed. (Total No of Lifts- 03 Nos)
All as per Item No. 86 herein before but during 2nd year after expiry of Defect Liability Period.
All as per Item No. 86 herein before but during 3rd year after expiry of Defect Liability Period.
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 32 of tender document i.e. Rs. 2,83,875.00
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.67 MB
80247PrePricedSchedules.pdf
Additional Documents • 0.88 MB
80247TenderDocument.pdf
Tender Documents • 3.10 MB
BOQ_846883.xls
BOQ • 0.36 MB
80247ArchitecturalDrawings.pdf
Additional Documents • 21.54 MB
80247StructuralDrawings.pdf
Additional Documents • 7.72 MB
Download all tender documents and submit your bid