Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L1 | Accepted-AOC Accepted -AOC | |
| 2 | L2₹34.5 L+₹1.8 L (5.39%)Rejected-AOC | L2 | Rejected-AOC Rejected - AOC | |
| 3 | L3₹35.7 L+₹3.0 L (9.16%)Rejected-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | MEERUT | UTTAR PRADESH | 250110 | L3 | Rejected-AOC Rejected - AOC | |
| 4 | L4₹36.5 L+₹3.8 L (11.5%)Rejected-AOC | L4 | Rejected-AOC Rejected - AOC | |
| 5 | L5₹38.5 L+₹5.8 L (17.7%)Rejected-AOC 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L5 | Rejected-AOC Rejected - AOC |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
4 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEHRADUN
GE Dehradun, Mall Road, Garhi Cantt, Dehradun
Spl repair to OTM Accn Bldg No T-50 at KGBS and Bldg No T-47 of 2/9 GR, Provn of Entrance Gate with Pillars at 2/9GR, Spl Repair to Toilet of URC Complex HQ Sub Area, Spl Repair to Bldg No P-116 At RIMC, Spl Repair to Bldg No T-187 Of 501 FSEG and
2020_MES_358808_1
8226/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE DEHRADUN
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹94,000
Yes
9 Sept 2020
7 Jul 2020
6 Aug 2020
7 Jul 2020
4 Aug 2020
21 Jul 2020
60 days
Amount
Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering incl ridge, velly gutters complete all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. complete all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.specified and directed.
Dismantling timber scantling 40 sq. cm and over in section, in any position complete all as specified and directed.
Dismantling timber in fillets, rails, posts, rafters, pueline, etc. under 40 sq. cm in section complete all as specified and directed.
S&Fmild steel work in plate girder or single stanchions, built up of one beam or channel section with flange plates, caps bases. splices, angle brackets, cleats and other connections by conforming to FE 410-W (gde E-250) complete all as specified and directed.
S & F of rolled mild steel sections as in roof purlins, cleats, rails fastening (beam TEE, angle or flat sections ) includin distance pieces, cleats etc including cutting welding etc conforming to Fe -410-W (Gde E 250 ) quality B complete all as specified and directed.
S&F of plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe -410-W (Gde E 250 ) quality B complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below and above ground level) complete all as specified and directed.
M&L cement concrete 25mm thick 1:2:4 type B0 using 12.5mm graded stone agg as in floor finished fair and even to receive floor finishes complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 sqm n.exc 2 sqm each and refixing in same opening after necesssary repair complete all as specified.
M&L for preparation of old painted steel surfaces over 10 cm width/girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of old painted surfaces of wood over 10 cm width/girth and applying one coat of PU interior acrylic based clear coating paint all as specified and directed.
M&L for preparationof old plastered surface of wall by brooming down and applying one coat of oil bound distemper complete all as specified and directed.
M&L 35mm thick 2nd class hard wood factory made plain framed panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply. The size of rail and stile as per IS:1003 (Part1),kiln seasoned and chemically pressure treated, all as specified and directed.
S&F 35 mm thick 2nd class hard wood factory made glazed and skelton shutter open rebated and prepared to receive glass gauge etc (without sash bars ) edges of framing plain,chamfered or rounded fitted with cut and mitred beads or clearing glass edges of framing plain, chamfered or rounded fitted with cut and mitred beads or clearing glass etc complete all as specified and directed. Sizes of members of shutters as specified in SSR part I section 8 clause 8.20 (a).
S&F 300mm long Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing blots & sliding bolts of extruded section or cast aluminium alloy & fixed complete all as specified and directed.
S&F MS but hinges cold rolled medium weight 100 mm size complete all as specified and directed.
S&F aluminium handle cast type anodized of 125mm size complete all as specified and directed.
S&F mild steel hinge medium weight cold rolled 75mm long complete all as specified and directed.
S&F aluminium anodized barrel tower bolt 200 mm complete all as specified and directed.
S&F framed work such as grills ,grating etc with ends of bars shouldered or riveted, or forged into spikes conforming to Fe 290-Gde -E-165 complete all as specified and directed.
M & L for preparation of new or previously un-treated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality in square nexc 0.50sqm each pane complete all as specified and directed.
Demolition of brick work/ Stone masonery built in cement mortar or cement lime mortar complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work (except bricks), straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1 :6 complete all as specified and directed. NOTE:- Old bricks retrived under item No. 26 above shall be reused.
Demolition of cement concrete of any description not other wise specifically provided for complete all as specified and directed.
M&L cement concrete 1:2:4 B-0 (using 12.5 mm graded stone agg) in coping, bed plates, gola and chamfered angles and throating etc complete all as specified and directed.
Taking down cement plaster from brick or stone walls etc, including racking out joints, hacking for key, and scrubbing down with water etc ,complete all as specified and directed.
M & L 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surface, surface finished even and fair complete all as specified and directed. Note : Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick.
M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and fair complete all as specified and directed.
M & L 10 mm thick rendering in cement mortar 1:3 on concrete surface as ic ceiling, surface finished even and fair complete all as specified and directed.
M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, using water proofing compound surface finished even and fair complete all as specified and directed. Note : Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick. (water proofing compound will be measured and paid separately)
Preparation of new plastered/putty surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for applying two coats of cement base paint on new plastered surfaces of walls including preparation of surface complete all as specified and directed.
M & L for preparing old plastered surfaces and applying one coats of cement base paint complete all as specified and directed.
M&L for applying two coats of cement base paint on new plastered surfaces of walls including preparation of surface complete all as specified and directed.
M&L machine cut kota stone slab flooring 18-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including mirror finish over and including 15mm screed in cm 1:6 complete all as specified and directed.
M&L machine cut kota stone slab as in skirting/dado 18-22 mm thick over cement plaster with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing including 10mm rendering in cm 1:4 complete all as specified and directed.
S & F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay,tower bolt etc. complete with glazing bars, dovetailed or welded including dismantling old steel window complete.
S & F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc.complete without glazing bars, dovetailed or welded including dismantling old steel window complete .
Demolition of existing stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L 18 to 20 mm thick machine cut polished granite 1st quality "black" stone slab over kitchen platform and similar places over and including 15mm thick screed bed in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match with existing surface and grinding and moulding of exposed edges of granite complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
M & L for preparation of new or previously un-treated wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M & L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base complete.
M & L PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in foundation filling, mass concrete complete.
M & L for RCC 1:2:4, type B-1 (20 mm graded stone agg) as in columns, pillars, piers, posts and strut etc,complete all as specified and directed.
M & L for RCC 1:2:4, type B-1 (20 mm graded stone agg) as in foundation, incl rafts footing etccomplete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended roof slabs , shelves etc and similar works n.exc. 200mm thick horizontal or sloping for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging with and including either hooks and hinges or steel hanging door fittings and fixing complete, structural steel conform to Fe 410w (Gde & 250) quality 'A' all as specified and directed.
M&L for 1.00mm thick mild steel plain black sheet in covering to door shutters covering to door chowkhats, water troughs, urinal troughs and funnels and the like cut to size edges based it directed, holes punched, including round head screws clout nails or rivets fixed to wood or steel member etc with plain 40mm lap joints or welded/reveted scans including bending turning up, mitred angle, stop ends outlet etc as required complete all as specified and directed by Engr-in-Charge.
M & L for cast iron ornamantal / fency work for gates complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement motor bedding (But not backing), removing serviceable tiles to stone and rubbish off the premises
M&L for Vitrified Ceramic tiles double charged light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. fixed with adhesive including screed bed 15 mm thick in CM 1:6 set and jointed and pointed in white or coloured cement to match with tile complete all as specified
All as per item 62 above but as in skirting including rendering 10 mm thick in CM 1:4 complete all as specified and as directed.
M&L for complete removal of existing treatment from wall surfaces and M&L applying wall putty 2 to 3 mm thick complete all as specified.
M&L preparation of new plaster surface of ceiling and applying three coats of white wash complete all as specified and as directed by Engr-in-Charge.
Providing & fixing tiled false ceiling of Everest Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm
Item No 66 contd--/ and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, at any heights including dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified and as directed by Engr-in-Charge.
M&L for Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed by Engr-in-Charge.
M&L for Anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed by Engr-in-Charge.
Supplying, laying, jointing and testing salt glazed stone ware drain pipe 150mm dia of grade ‘A’ confirming to IS–651–1980 laid in trenches and jointed in cement mortar 1:1 complete.
M & L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in cement concrete bed to for 150mm dia SGSW drain pipe including packing under and haunching against sides of pipe after they are laid and tested complete.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and as directed.
M&L for RCC M-20 (nomonal mix) type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like, complete all as specified and as directed.
S & F 110 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall complete all as specified and as directed. Make : Supreme/Finolex
S & F 110 mm bore UPVC (SWR) bend,'T'socket reducer etc complete all as specified and as directed. Make : Supreme/Finolex
M&L precast factory made PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in man hole covers, landings, chajjas etc and similar articles with plain faces set in CM 1:6 including necessary reinforcement and form work complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels up to 1.5m clear span, cills, steps, copings, bed plate and like, edges slightly rounded or chamfered including necessary form work complete all as specified and as directed. (Reinforcement shall be measured separately)
M&L for construction of soakage well, 1.80M dia & effective depth 3.0M including excavation in any type of soil, foundation PCC, masonary, RCC,including intercepting chamber ad screen chamber, interconnecting RCC/DWC pipes, brick bat filling etc. complete all as shown on TD drawing, as specified & directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type pressed steel terminal box 1.2mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge for the following. Make of PVC Wire: Havells/KEI/Finolex/L&T. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
(a) One light point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per Item No 79.00 here in above but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts.
S & F bell push flush type 5 Amps 230 Volts single pole complete.
S&F Bell Ding dong 250V AC complete all as specified & directed. Make : Havells/L&T Raaga/Anchor
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC.
S&F lamp holder, pvc/polycarbonate type with back plate suitable for batten fittings complete all as specified & directed.
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly including taking out existing sub main wiring and making good to disturbed surfaces complete all as specified & directed Make of PVC Wire: Havells/KEI/Finolex/L&T.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly drawing through and including 20 mm dia medium density concealled PVC conduit pipe including taking out existing sub main wiring and making good to disturbed surfaces complete all as specified & directed Make of PVC Wire: Havells/KEI/Finolex/L&T.
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed Make Legrand/Schneider/ABB..
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 12 way DB,s IP-43 IK 09 metal door complete all as specified and directed Make Legrand/Schneider/ABB..
S&F in replacement sheet metal enclosures TP&N, 415 volt with 200 Amp rated bus bar double door 12 way DB,s IP-43 IK 09 metal door suitable for one MCCB 100 Amp as incoming and 12 MCB SP as out going complete all as specified and directed Make Legrand/Schneider/ABB..
Supply, fixing in replacement and Testing TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 IK - 09 DB's flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement for MCCB 125 to 63 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Engr-in-charge incl taking out Unserviceable DBs, MCCB and MCBs of any capacity, Make: Legrand/L&T/Simens/Schneider. (Note: MCBs MCCB shall be measured and paid separately)
S&F MCB double pole 240 Volt 10 KA 40 Amp conforming to IS 8828 ISI marked complete all as specified & directed Make Legrand/Schneider/ABB.
S&F MCB single pole 240 volt 10 KA 5-40 Amp conforming to IS 8828 ISI marked all as specified and directed Make Legrand/Schneider/ABB.
S&F in replacement of MCCB 63 Amps 16 kA, four pole 415 volts magnetic trip release and setting as incoming ICU=100% ICS including connection terminal strip complete all as specified & directed. Make: Legrand/L&T/Simens/Schneider.
S&F in replacement of MCCB 100 Amps 16 kA, four pole 415 volts magnetic trip release and setting as incoming ICU=100% ICS including connection terminal strip complete all as specified & directed. Make: Legrand/L&T/Simens/Schneider.
S&F in replacement of MCCB 125 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed Make: Legrand/L&T/Simens/Schneider.
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 4000K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make:Wipro Cat part No LL20-281-XXX-65AL1/ Philips cat part No BN021C LED20S PSU CWGR S2/Havells Cat No ENDURA LINEARNEOBS20W LED865SPCWH.
S&F in replacement Decorative Square/Round surface mounted LED flat panel PDC aluminium housing and PMPA diffuser makes it a robust Luminaire 12 Watts PF 0.9 and above operating voltage 150V-300V colour temp 4000K & lumen input output 70 Lumen per watt incl provisioning of 3 core white flexible multistranded copper conductor 23/0.0076 from ceiling rose to light connector complete all as specified and directed by Engineer-in-charge Make : Crompton cat part No LCDN-12-CDL/TL/WW/Wipro cat No LD80-101-XXX-60-XX/Philips Cat No DN092B LED10S-3000-PSU-WH
S&F in replacement of Decorative wall light fixture made up of Polycarbonate, suitable for 15 Watts LED Lamp incl one LED New Odore 10W E27 WW Ball Lamp Lumen output 835 (lm) 3000K complete all as specified and directed by Engineer-in-charge Make : Havells (City-1) cat part No LHDL02160099 (Fitting) LHLDERHEMD8X010(Lamp) or eqvt in Wipro / Philips / Mepro.
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9 Watt or higher LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make Havells Cat No E-Lite Pride LHEXBLP7IN1W009 or eqvt in Philips/Wipro
Supply and fixing in replacement New generation energy saving and environmental friendly long life LED Street light luminaire Endura Pearl Neo made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 with separate surge protection 5KA, 40 Watts or near higher size with making all arrangement for fixing light fitting such as replacement of GI pipe bracket made of 40 mm bore medium grade pipe made to shape of 1200 of 70 cm and 50 cm to a overall length of 1.2 mtr for fixing of street light fitting including MS clamps of size 32 x 3 mm flat iron, nuts, bolts and washers of required size painting complete with all necessary electric connection etc all as specified and directed incl taking down the existing unserviceable bldg security light fitting complete all as specified and directed Make : Havells cat part No. ENDURAPEARL NEOSL40WLED757PASYTOPC/ CG Cat No LSTP-45-CDL / Philips Cat No BRP046 LED 36 CW MR S1 PSU GR /Greenstar DSS 40.
S&F in replacement of energy saving Bulk head luminaire with opal diffuser with and including retrofit LED lamp 10 watts complete all as specified and directed by Engr-in-charge. Make : CG cat LBHP-10-CDL/Philips WT140W LED7S CW PSU S1 PC/Havells ENDURA RUGBYNEO N /Bajaj cat no BIBWP10WLED.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a direct fit in holder complete all as specified and directed.
Disconnecting electric connection and taking down of ceiling fan of any sweep keeping in safe for re use with rusted hook, fan rod, mounting clamps,and fixing after necessary repair,servicing, painting etc including supply of new hook of FI 50x6mm in suitable shape and welded to truss with adjusting fan rod as per site requirement and connected by 3 core multistrand copper conductor 23/0.0076 from ceiling rose to fan connector ,complete all as specified and directed.
Disconnecting electric connection and taking down of exhaust fan of any sweep ,keeping in safe custody for re- use and dismantling fan blades, removing rust & cavity, servicing, oiling, painting and re-fixing the same as per existing position including connection by new 3 core multistrand copper conductor 23/0.0076 from ceiling rose to fan connector ,complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5M wide and not exceeding 1.5M in depth for foundations, shafts, sewage line, manhole, cables etc not exceeding 10 sqm on plan and getting out in soft loose soil complete.
Excavation in over areas n.exc 1.50m deep and getting out in any type of soil complete.
Excavation in over areas exc 1.50m and n.exc. 3.0 deep and getting out in any type of soil complete.
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete.
Removing excavated material to a distance n exc 50m and deposited where directed at a level n. exc 1.5M above the starting point complete.
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with multi stranded aluminum conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and overall PVC sheathed 1100 Volts grade, nominal cross sectional area 25 Sqmm 4 core incl lugs thimbles bottle timbles and gun metal cable glands and heat shrinkable PVC sleeves on exposed surfaces and teflon tape duly insulated complete laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/ floors/ equipment etc including taking out/down existing cable complete all as specified and directed by the Engr-in-Charge. Make : Havells/Polycab/KEI/Grandlay
M&L for sand cushioning in trenches for protection of UG cable with river bed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Supply and laying GI Steel tubing light grade 40 mm dia including all fitting laying in trenches or grouting/fixing in wall for protection of cable complete all as specified and directed by Engineer-in-charge
Supply and fixing in repairs LED Street light luminaire comprising of pressure die cast aluminium housing heat resistant toughened glass IP-65, photovoltic LDR sensor with separate surge protection 5KA, 35 Watts or near higher size with making all arrangement for fixing light fitting such replacement of GI pipe bracket made of 40 mm bore medium grade pipe made to shape of 1200 of 70 cm and 50 cm to a overall length of 1.2 mtr for fixing of street light fitting including MS clamps of size 32 x 3 mm flat iron, nuts, bolts and washers of required size painting complete with all necessary electric connection etc all as specified and directed as per Greenstar Cat No: DSS3 or equivalent in Philips / Crompton.
M&L for 10sqm twin core cable flat or circular 1100 volts grade heavy duty with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed as in service connection, suspended by insulating hanger not more than 1m apart, including 4mm suspension wire including taking down existing cable complete all as specified.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end,
All as per item No 121.00 Contd....GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed. Note: (i) If the desired earth resistance is not found within permissible limit earthing shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
M/S JAI PRAKASH GOEL
Arun Construction Co.
M/s Inderlal
RAMAPATI ENGINEERING SERVICES
Freya Infrastructure
M/S Anil kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .