Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | ₹15.2 L | L1 | Accepted-AOC lowest |
| 2 | L2₹15.3 LRejected-AOC CHAKKALAKKAL H KOTTAT P O | ₹15.3 L | L2 | Rejected-AOC highest |
| Sl No | Description | Qty | Unit | KIRAN MG L1 | BIJU JOSE L2 |
|---|---|---|---|---|---|
| 1.00ELETRIFICATION | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 18 | point | 1,500 ₹27,000 | 1,400 ₹25,200 |
| 1.00 | OD216629/2025-2026:Supply Conveyance, installation, testing and commissioning of 250W LED Flood light having luminous efficacy greater than120 lm/W substantiated via LM79/LM80 photomatric validation protocals 4000-5665 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea/OSRAM/Bridgelux/ Seoul with power factor greater than 0.95 at full load, surge protection up to 10 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.95, RoHS compliant, duly wired up for use on 230 V AC supply. (Philips/Crompton/Havels/Jaquar) | 26 | each | 13,000 ₹3.4 L | 13,250 ₹3.4 L |
| 1.00 | OD277622/2025-2026:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 120 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumileds/Nichea/bridgelux/ Seoul with power factor greater than 0.95 at full load, internal surge protection up to 10 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 12 | each | 6,000 ₹72,000 | 6,500 ₹78,000 |
| 1.00 | OD277700/2025-2026:Supply Conveyance, installation, testing and commissioning of 45W LED Flood light output greater than 110 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea/Bridgelux/Seoul with power factor greater than 0.95 at full load, internal surge protection up to 10 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 7 | each | 4,000 ₹28,000 | 4,400 ₹30,800 |
| 1.00 | 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters | 3 | each | 27,000 ₹81,000 | 30,000 ₹90,000 |
| 1.01 | OD190909/2025-2026:Supply & fixing Analog time switch in existing enclosure and giving connection ( Make :L&T : AUTS03ANA00 or equivalent) | 2 | each | 1,500 ₹3,000 | 1,600 ₹3,200 |
| 1.01 | OD190908/2025-2026:Supply & fixing 9 A, 2 Pole Mini contactor, AC 3 Rating, in existing enclosure and giving connection ( Make :L&T : MNX 9-2P or equivalent) | 2 | each | 700 ₹1,400 | 750 ₹1,500 |
| 1.01 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps | 10 | metre | 500 ₹5,000 | 700 ₹7,000 |
| 1.01 | OD188107/2025-2026:Supply and fixing10 Watt LED bulk head with Pressure Di- cast aluminium body with poly carbonate cover to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core copper flex wire ( L&T make Endura LED / Equivalent make )
round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making
good the surface as required.Bulk head fitting. | 3 | each | 1,800 ₹5,400 | 1,800 ₹5,400 |
Tender Value
Refer Docs
EMD Value
₹41,311
Closing Date
24 Jan 2026, 6:00 pmClosed
Executive Engineer
Office of the Executive Engineer, PWD Electrical Division, Thrissur
GENERAL Conversion of Edavilangu Kara ground to Stadium-Electrical work-General Electrical Work
2026_PWD_828499_1
PWD/BLDG/15131/2025-2026
Open Tender
Electrical Works
120 days
Edavilangu
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
₹41,311
12 May 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
24 Jan 2026
17 Jan 2026
ELETRIFICATION
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD216629/2025-2026:Supply Conveyance, installation, testing and commissioning of 250W LED Flood light having luminous efficacy greater than120 lm/W substantiated via LM79/LM80 photomatric validation protocals 4000-5665 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea/OSRAM/Bridgelux/ Seoul with power factor greater than 0.95 at full load, surge protection up to 10 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.95, RoHS compliant, duly wired up for use on 230 V AC supply. (Philips/Crompton/Havels/Jaquar)
OD277622/2025-2026:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 120 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumileds/Nichea/bridgelux/ Seoul with power factor greater than 0.95 at full load, internal surge protection up to 10 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD277700/2025-2026:Supply Conveyance, installation, testing and commissioning of 45W LED Flood light output greater than 110 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea/Bridgelux/Seoul with power factor greater than 0.95 at full load, internal surge protection up to 10 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
OD190909/2025-2026:Supply & fixing Analog time switch in existing enclosure and giving connection ( Make :L&T : AUTS03ANA00 or equivalent)
OD190908/2025-2026:Supply & fixing 9 A, 2 Pole Mini contactor, AC 3 Rating, in existing enclosure and giving connection ( Make :L&T : MNX 9-2P or equivalent)
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD188107/2025-2026:Supply and fixing10 Watt LED bulk head with Pressure Di- cast aluminium body with poly carbonate cover to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core copper flex wire ( L&T make Endura LED / Equivalent make ) round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.Bulk head fitting.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD188104/2025-2026:Supply of 9 W LED bulb B22 base type.wipro/philips/Hallonix/crompton/approved make
OD273459/2025-2026: Supply, conveyance, installation, testing and commissioning the light fittings made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. including providing 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted )
OD277731/2025-2026:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep -BEE 5 star rated ceiling fan with brushless direct current(BLDC) motor complete with all accessories/fittings/supports etc suitable for 230V/240V single phase AC supply
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD188155/2025-2026:Supply, conveyance installation testing & commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C. including giving connection with 3 core round copper conductor flex wire of 1. sqmm
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD186868/2025-2026:Supplying and providing extra HG conduit down rod of 19 mm dia 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc as required.
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
OD186863/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 3 mm G.I. strip
OD186869/2025-2026:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip
OD186875/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25 x 6 mm brass bolt & nut
OD186866/2025-2026:Supply and fixing 50 mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe)
OD186862/2025-2026:Supply and providing suitable Iron Hook grouted on wall for binding the service wire
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
OD188711/2025-2026:Supply, conveyance, erection, testing and commissioning of 1HP submersible horizontal type high speed single Phase Submersible Monoblock motor pump set with Control board , having an average discharge of 1.8 ltrs /S-21 Mtr head ,suitable for 230 V,50 Hz,1 Phase AC Supply,(Kirlosker-KOSi-135/equivalent make) complete with standard accessories etc as required.
OD188787/2025-2026:Supply and providing special make steel connector with clamp suitable for 25 mm PVC pipe for connecting with motor pump set etc as required
OD188798/2025-2026:Supply and providing 15mm/nearest size nylon rope submarine blue make for hanging the motor pump set
OD188793/2025-2026:Supply and providing of 25 mm/nearest size3 duro flex/cano flex PVC flexible pipe as delivery pipe from well to ground level etc as required
90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
OD188796/2025-2026:Supply and providing 25mm stainless steel Hose Collar with hose clip
OD188799/2025-2026:Supply and providing 25 mm /nearest size Brass NRV on the suction/ delivery side of the pump set etc as required
90.14.28.1:S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD194263/2025-2026:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level thermo-mechanically Treated bars of grade Fe-500D or more
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.7.38:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
90.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp
90.12.5.13:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.12.5.12:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm
OD194489/2025-2026:Supply and fixing the following accessories in the existing meter board and giving connections etc.(63A, HRC Fuse Base with HRC Fuse link)
OD194490/2025-2026:Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic Syntex meter box of folowing size suitable for fixing 3 pase KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 650x350x250 (GS-MB 6535)
OD194491/2025-2026:Supply and installation of switch gear units with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work using necessary bolts & nuts, making good the damages, color washing etc. including giving necessary connections as required. (excluding cost of HRC fuse links in case of SDF/ SDFCO) ( front handle) 63 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN / BS fuse
OD194492/2025-2026:Supplying and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD216715/2025-2026:Supply and fixing 4 MODULE WEATHER PROOF BOX IP 65- IK 09 CLASS II
OD194870/2025-2026:Supply and fixing of Bakelite Terminal Block, 5-Way, 40A, in the existing box with nut and bolts.
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
OD210419/2025-2026:Supply and providing of Automatic Transfer Switch 63A with in built controller, in the existing enclosure and including drilling holes and giving connection etc as required.
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
OD211621/2025-2026:Supply & fixing SMC Junction box with Hinged Door Having Dimension 140X140X90MM for Street Lights.
OD211624/2025-2026:Supply and fixing 4P sheet Steel enclosure on surface/recess complete with connections, testing and commissioning etc as required.
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
OD211957/2025-2026:Charges for preparation of Electrical / fire drawing per A3 sheet copy for additional copies
OD211958/2025-2026:Charges for preparation of Electrical / fire drawing per A3 sheet first copy
OD212079/2025-2026:Supply, conveyance installation testing and commissioning the LED type indicator for 230/415 V- red, Green, Yellow or Orange color in existing panel board.
OD212080/2025-2026:Supply, conveyance installation testing and commissioning the LED type indicator for 230/415 V- Blue color in existing panel board.
OD215193/2025-2026:Supply , Installation and Testing of 15 KVA/12 kW, Diesel Generator set as per CPCB IV + including required contactors/ control devices, protection such as suitable MCCB and earth fault relay using CT in neutral earthing conductor, and accoustic enclosure as per CPCB norms and as per technical details given below on suitable size CC foundation, including SMPS charger etc as required 1. Engine. a) Make of Engine - Kirloskar/ Cummins / Leyland b.Type of Engine - Diesel Engine. c. No. of Cylinders - As per manufactures standards. d. Method of cooling - Water cooled with radiator e. Aspiration - Turbo charged after cooled f. Design - Suitable for generating set operation. g. Out put - Required HP as per manufacturers standards at 1500 rpm under NTP condition. 2. Standard accessories with Diesel Engine a. Fly wheel to suit flexible coupling b. Close Coupling. c. Air cleaner. d. Radiator with fan provided with fan guard e. Fuel Pump. f. Mechanical governor. g. Fuel filter. h. Lubricating oil filter. i. Exhaust silencer. j. Exhaust Muffler k. Battery Charger/Generator 3. Engine Instrument Panel with the following items. a. Starting switch with key or button b. Lubricating oil pressure gauge. c. Water temperature gauge. d. RPM Indicator with hour meter. e. Battery charging ammeter. f. Fuel indicator 4. Safety Controls for Engine a. Trip for low lubricating oil pressure. b. Trip for high water temperature. c. Alarm for low fuel level 6. Brushless Alternator a. Make - Stamford / Kirloskar /Leroy somer/crompton b. Type - Self exited and self regulated. c. Capacity - 25 KVA/ 20kW @ 0.8 PF d. System of Voltage - 3 Phase, 415 V, 4 wire system e. Speed - 1500 rpm. f. Voltage regulation band - +/- 5% of rated voltage g. Frequency : 50 Hz h. Insulation - Class F / H The alternator should confirm to IS 4722 and warranteed for 3 years.Operation and service manual , spares and tools shall be provided. 8. Fuel Tank Suitable size built in type integrated with the acoustic enclosure with full tank Diesel Fuel connection shall be done as per standards 9. Battery. Suitable capacity fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. 10. Supplying and providing inbuilt Battery charger suitable for the 25 KVA DG set 11.Tools Kit standared manual control system including all necessary accessories and meters Accoustic enclosure: As per CPCB norms The DG set should have warranty of 3 years from the date of installation. Also the Contractor should carry out periodical services as per manufactures instruction, including supply of consumables during DLP
OD215303/2025-2026:Supply and providing the following size of C class MS pipe conforming to relevant IS specifications complete with heavy guage specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/wall/any other mechanical support etc as required.- 80 mm dia C class MS pipe as extended exhaust pipe.
OD215306/2025-2026:Roofing with powder coated Aluminium trafford profile sheet having 0.7 mm thickness ,over truss with necessary overlap at ends with nuts and bolts.
OD215307/2025-2026:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (Sanctioned rate DSOR 50.10.1)
OD215308/2025-2026:Supply of High Speed Diesel for Load test and Trial Run.
OD215616/2025-2026:Supply and installation of ABC type fire extinguisher of 4 kg. Capacity complete with initial charges and installation brackets.Supply and installation, testing and commissioning of DCP type fire extinguisher with 5 kg. Capacity complete with installation brackets with ISI mark IS:15222
OD215611/2025-2026:Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive,
OD215588/2025-2026:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of redoxide and written with white paint 'FIRE', filled with fine sand, mounted on existing MS angle frame work / wall bracket etc. as required.
OD215589/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tendernotice_2.pdf
PDF • 0.46 MB
Tendernotice_3.pdf
PDF • 0.54 MB
SBD.pdf
Tender Documents • 1.78 MB
NIT.pdf
Tender Documents • 0.02 MB
BOQ_1390849.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid