| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | ₹3.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.4 Cr+₹15.0 L (4.64%)Rejected-AOC 32 1089 KALAMASSERY CHANGAMPUZHA NAGAR COCHIN ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | ₹3.4 Cr+₹15.0 L (4.64%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.5 Cr+₹25.2 L (7.79%)Rejected-AOC ERNAKULAM KERALA 682301 INDIA | ERNAKULAM | KERALA | 682301 | ₹3.5 Cr+₹25.2 L (7.79%) | L3 | Rejected-AOC L3 |
| 4 | L4₹3.8 Cr+₹60.1 L (18.6%)Rejected-AOC 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹3.8 Cr+₹60.1 L (18.6%) | L4 | Rejected-AOC L4 |
Tender Value
₹3 Cr
EMD Value
₹1 L
Closing Date
5 Jul 2024, 1:00 pmClosed
Chief Executive Officer
Chief Executive Officer,Park Centre, Technopark Phase I Campus, Trivandrum
Electrification works of Commercial Building, Technopark Phase-I Campus.
2024_ETPK_676795_1
ETPK/PH-I/2024-25/E-02
Open Tender
Electrical Works
Item Rate
75 days
Technopark Phase I
Please refer Tender document
8 documents required · 8 mandatory
₹8,850
₹1 L
Park Centre, Technopark Phase I Campus
7 Aug 2024
19 Jun 2024
6 Jul 2024
19 Jun 2024
5 Jul 2024
24 Jun 2024
24 Jun 2024
Amount
Supply, Installation Testing and Commissioning of 11kV SF6 insulated, Ring Main Unit with 630A, 21kA, 1sec both side extensible outdoor motorized RMU consists of 2nos. motorised Load break switches for Cable Entry with 2 no of vacuum Circuit Breaker for out going (+CCVV+ configuration) with protection relay, battery, battery charger, SCADA compatible, indicators, hooter etc. with all accessories as per technical specification. The RMU shall have bottom cable entry from front side. FRTU shall be provided integrated with RMU completely wired along with Modem suitable for communicating with main SCADA room through OFC network. Provision of communication through GSM network shall be available. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from SCADA. FRTU shall be powered by 24V DC system with necessary protection.
HT PANEL
Supplying, installation, testing & commissioning of indoor type floor mounted, dust and vermin proof, 11 KV VCB (OEM) panel with 12kV, 630A, 21kA for 1 sec, horizontal drawout, horizontal isolation type vacuum circuit breaker, the panel shall be fully type tested as per IEC 62271-200 as amended up to date. The operating mechanism shall be electrically spring charged and auto/manually closing breaker capable of remote operation & monitoring through SCADA with fully interlocked, rack in and rack out mechanism, air insulated with support insulators/Self supported type aluminum bus bars of 630 Amps capacity and as per detailed technical specification, SLD enclosed and meeting the specified IS, IEC, and KSEI standards.
Power Pack/UPS: HT panel shall include a POWER PACK/UPS of required capacity for auxiliary power supply unit with all accessories required for complete installation.
OUTGOING-01 (a) 01 No, 630A, 21kA VCB (b) 3 No. CT's (resin cast) with ratio 100/50/5A of 15 VA burden and accuracy Class – 0.5, 3 No. – (0-100 A)digital type ammeters. (c) 1 No. – Microprocessor-based numerical relay with 2 nos O/L, 1 E/F and S/C protection. (d) 1 – Set of dual core dual ratio CTs (3nos) (resin cast) 100/50/5 A of 15 VA burden and accuracy Class –class 5P10 for protection. (e) 1 – Set HT TOD meter with RS485 communication port with dual core CTs (resin cast) (3nos) with ratio 100/50/5 A of 15 VA burden and accuracy class –0.2s and PTs (3 nos) 11 KV/ 110V PT with 0.2 accuracy class and 100VA burden.
OUTGOING-02 (a) 01 No, 630A, 21kA VCB (b) 3 No. CT's (resin cast) with ratio 100/50/5A of 15 VA burden and accuracy Class – 0.5, 3 No. – (0-100 A) digital type ammeters. (c) 1 No. – Microprocessor-based numerical relay with 2 nos O/L, 1 E/F and S/C protection. (d) 1 – Set of dual core dual ratio CTs (3nos) (resin cast) 100/50/5 A of 15 VA burden and accuracy Class –class 5P10 for protection. (e) 1 – Set HT TOD meter with RS485 communication port with dual core CTs (resin cast) (3nos) with ratio 100/50/5 A of 15 VA burden and accuracy class –0.2s and PTs (3 nos) 11 KV/ 110V PT with 0.2 accuracy class and 100VA burden.
The following operations of the HT Panel shall be performed through ECS (Electrical Control Sysytem): 1. I/C- ON, OFF & RESET 2.O/G-01- ON, OFF & RESET 3.O/G-02 ON, OFF & RESET The following status parameters of the HT Panel shall be monitored through ECS (Electrical Control Sysytem): 1. I/C- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 2.O/G-01- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 3.O/G-02- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE
The following parameters from the numerical relays shall be monitored through ECS: 1. I/C- Num relay operated on Earth Fault, Ovr crt, Short Ckt 2. O/G-01- Num relay operated on Earth Fault, Ovr crt, Short Ckt 3. O/G-02- Num relay operated on Earth Fault, Ovr crt, Short Ckt The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
TRANSFORMER - 750 kVA 11kV/433V Cast Resin (Dry type)
Supply, installation, testing & commissioning of 750 kVA 11kV/433V 3-phase 50 Hz Indoor cast resin dry type transformer, having vector group Dyn 11 with tapping +5% to -5% in steps of 2.5% by off-circuit tap links. The transformer shall include winding temperature indicators for each phase and the core. Total Loss at Rated Voltage at Principal Tapping, Rated Frequency, with 100% load at 120°C shall be less than 8500W(+/-5%). The transformer shall be complete with all accessories as required, conforming to KSEI, ECBC, IE rules, and specifications, and meeting IEC 60076-11 standards with the latest amendments. (All associated works, including loading, unloading at the site, erection at the site, and movements, etc., shall be within the scope of work)
DG Sets
DG SET-500kVA
Supply, installation, testing and commissioning of 3phase 415V, 0.8pf 50Hz. DG set of the ratings 400KW/500 KVA, Water cooled Diesel generating set of prime duty comprising of diesel engine alternator, inbuilt fuel tank & Separate 700 ltr day tank with necessary fuel line pipe of 25mm MS pipe (heavy duty type) with necessary bends, clamps,supports and valves,painting as required, automatic starting system, battery, battery charger, electronic governor etc with all accessories required for synchronising the DG with another DG. The Generator set shall have a integral type acoustic enclosure as per latest CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with CPCB IV+ specifications. Generator set inclusive of fly wheel, flexible coupling, air cleaner, corrossion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 24V battery with regulator, instrument panel, rpm indicator, residential silencer, complete with necessary control wiring compatible with SCADA, interconnections etc. including first filling of oil and diesel for commissioning of the DG set. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary vibration isolation arrangement as per recommendations of manufacturer, which shall be installed on suitable cement concrete foundation as per manufacturers' standards. Exhaust pipe with suitable specifications with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 20 m in stages including suitable rain gaurd for top. Fixing shall be done with proper clamps, expansion bolts, support angle of size 40 X 40 X 6 mm fixed on the wall/ inside the duct as instructed by the Engineer.
DG SET-320kVA
Supply, installation, testing and commissioning of 3phase 415V, 0.8pf 50Hz. DG set of the ratings 250 KW/320 KVA, Water cooled Diesel generating set of prime duty comprising of diesel engine alternator, inbuilt fuel tank & Separate 500 ltr day tank with necessary fuel line pipe of 25mm MS pipe (heavy duty type) with necessary bends, clamps,supports and valves,painting as required, automatic starting system, battery, battery charger, electronic governor etc with all accessories required for synchronising the DG with another DG. The Generator set shall have a integral type acoustic enclosure as per latest CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with CPCB IV+ specifications. Generator set inclusive of fly wheel, flexible coupling, air cleaner, corrossion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 24V battery with regulator, instrument panel, rpm indicator, residential silencer, complete with necessary control wiring compatible with SCADA, interconnections etc. including first filling of oil and diesel for commissioning of the DG set. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary vibration isolation arrangement as per recommendations of manufacturer, which shall be installed on suitable cement concrete foundation as per manufacturers' standards. Exhaust pipe with suitable specifications with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 20 m in stages including suitable rain gaurd for top. Fixing shall be done with proper clamps, expansion bolts, support angle of size 40 X 40 X 6 mm fixed on the wall/ inside the duct as instructed by the Engineer.
LT - PANELS
Incomer:
1250A, 50kA,4P,uP Based, Eelectrically draw out type ACB with O/L,O/C (2 nos) & E/F (1no) release and with all accessories- 2 No
Advanced Multifunction meter- Cl 1- 2 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. The MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
1000/5A ,10 VA,Cast resin type ,CL:1 ,CT-6 Nos
Earth fault relay- 2 No
200/5A ,10 VA,Cast resin type ,CL:5P10 ,CT-2 Nos
Bus coupler:
1250A, 50kA,4P,uP Based EDO ACB with O/L,O/C&E/F release- 1 No
Outgoings:
800A, 50kA,4P,uP Based EDO ACB with O/L,O/C&E/F release and all accessories- 1 No
630A, 25 kA or above,uP based 4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1 No
400A, 25 kA or above,μP,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-2 No
3-phase TOD meter,class 0.5s with RS 485 communication port -2 Nos (The contractor should arrange for testing of CT & meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
650/5A ,10 VA,Cast resin type ,CL:0.5s ,CT-3 Nos
300/5A ,10 VA,Cast resin type ,CL:0.5s ,CT-3 Nos
The following operations of the MSB shall be performed through ECS (Electrical Control Sysytem): 1. I/C-01- ON, OFF & RESET 2. I/C-02- ON, OFF & RESET 3. B/C- ON, OFF & RESET The following status parameters of the MSB shall be monitored through ECS (Electrical Control Sysytem): 1. I/C-01- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 2. I/C-02- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 3. B/C- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meters shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
DG SYNC PANEL
DG Incomer 1 & 2:
800A,50kA,3P,uP Based EDO ACB with O/L,O/C& E/F release- 1 No
500A, 36 kA or above,up based,3P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1 No
Advanced Multifunction meter- Cl 1- 2 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. The MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
700/5A ,15 VA,Cast resin type ,CL:1 ,CT-3 Nos
450/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos
Earth Fault Relay- 2 No
140/5A,15 VA,Cast resin type ,CL: 5P10 ,CT-1 Nos
90/5A,15 VA,Cast resin type ,CL: 5P10 ,CT-1 Nos
350A Neutral Contactor- 1 No 250A Neutral Contactor- 1No
Bus Coupler:
800A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No
Outgoings:
800A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No
500A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No
400A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No
DG Synchronization and Load sharing System( with DIEF) of new 500kVA DG Set with new 320kVA DG set in the proposed DG Sync Panel
COMMON PANEL
Incomer:
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No
Advanced Multifunction meter- Cl 1- 1 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
200/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos
Outgoings:
63A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 7 Nos
Dual Source Energy meter (CT Operated, Flush mounted type) with RS485 communication- 3 Nos
50/5A, 10VA, CL:0.5s cast resin current transformer- 9 Nos (The contractor should arrange for testing of CT in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all Dual Source meters shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
SSB-TENANT
Incomer:
400A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-2No
Advanced Multifunction meter- Cl 1- 2 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
300/5A ,10 VA,Cast resin type ,CL:1 ,CT-6 Nos
Outgoings:
160A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No
200A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 3 Nos
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 2 No
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
SSB- COMMON AREA
Incomer:
800A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-2No
Advanced Multifunction meter- Cl 1- 3 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
650/5A ,10 VA,Cast resin type ,CL:1 ,CT-6 Nos
Outgoings:
630A, 25 kA or above,TM,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-3 No
400A, 25 kA or above,TM,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1 No
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 Nos
250A,25kA, 4P, Switch disconnector- 1 No
3-phase TOD meter,class 0.5s with RS 485 communication port - 2 No (The contractor should arrange for testing of meters & CTs in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5s with RS 485 communication port in the existing metering panels (Dual metering arrangement required as per SLD)- 2 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
MNX 25 3p Contactor for dual source arrangement for metering of two source of supply(Main supply and DG supply) - 2 Nos
400/5A ,10 VA,Cast resin type ,CL:0.5s ,CT-6 Nos
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
APFC PANEL- 225 kVAR
Incomer:
630A, 4-pole 25 kA,MCCB, Microprocessor type, variable settings ,extended rotary handle,Spreader Terminals, etc as required- 1 nos
Outgoings:225 kVAR
3 set of 50 KVAR MPP (Metalised Poly Propylene) Capacitor with 125A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 50 KVAR as required.
2 set of 25 KVAR MPP (Metalised Poly Propylene) Capacitor with 63A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 25 KVAR as required.
1 set of 15 KVAR MPP (Metalised Poly Propylene) Capacitor with 40A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 20 KVAR as required.
1 set of 10 KVAR MPP (Metalised Poly Propylene) Capacitor with 40A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 4 KVAR as required.
With necessary Aluminium busbars, interconnections, providing Digital Voltmeter,Ammeter , RYB and “ON / OFF / TRIP" indicating lamp at incomer, control PT, CTs, MPCBs and MCB and APFC Relay etc. and all other necessary accessories as per the specification/SLD. Each KVAR capacitor in a separate compartment with necessary ventilation arrangemnts or weld mesh arrangements as required by the KSEI guidelines
METERING PANEL- MP-GF
Incomer:
200A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No
Advanced Multifunction meter- Cl 1- 1 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
160/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos
Outgoings:
63A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos
40A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos
3-phase TOD meter,class 0.5s with RS 485 communication port (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5s with RS 485 communication port in the existing metering panels (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
50/5A, 10VA, CL:0.5s cast resin current transformer- 24 Nos (The contractor should arrange for testing of CT in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
MNX 25 3p Contactor for dual source arrangement for metering of two source of supply(Main supply and DG supply) - 8 Nos
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
METERING PANEL- MP-FF
Incomer:
200A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No
Advanced Multifunction meter- Cl 1- 1 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)
160/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos
Outgoings:
63A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos
40A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos
3-phase TOD meter,class 0.5s with RS 485 communication port (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5s with RS 485 communication port in the existing metering panels (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
50/5A, 10VA, CL:0.5s cast resin current transformer- 24 Nos (The contractor should arrange for testing of CT in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)
MNX 25 3p Contactor for dual source arrangement for metering of two source of supply(Main supply and DG supply) - 8 Nos
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost
ELECTRICAL CONTROL SYSTEM
Design, Integration with the existing SCADA network (IEC 60870-5-104 protocol) with Supply of all required accessories, and Commissioning of Electrical Control System for monitoring and control of RMUs, HT & LT panels. The work includes necessary modifications in the Central SCADA system with required changes in programming, purchase of additional licenses if required, modification in the firewall, etc. Providing FRTU with necessary controller compatible with IEC 60870-5-104 protocol, Digital Input Module, Digital Output Module , Serial Communication Module for communication with MFM's using Modbus RTU, 24V DC Power Supply System with SMPS (Switched Mode Power Supply) and backup batteries, Surge Protectors, Managed Network Switches (for data communication through OFC connectivity) and 4G/advanced routers to communicate with the Central SCADA system as primary and secondary network sources, and with all necessary accessories will come under the scope of work. There shall be a separate dashboard for the Commercial Building in the Central SCADA HMI for remote monitoring and control of the Electrical Panels and the RMU parameters shall be integrated into the existing dashboard. A laptop should be supplied for configuring the system with processor: i3 11th Gen or above, RAM: 8 GB DDR4 or above, SSD: 256 GB.
HT CABLE PART
Supply of following sizes of XLPE insulated non-FRLS Aluminium conductor armoured power cables of 11kV grade confirming to IS 7098:1988 amended upto date
1Cx500sqmm
3Cx300sqmm
3Cx185sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required and as per IS 1255:1983 amended upto date.
1Rx1Cx500sqmm
1Rx3Cx300sqmm
1Rx3Cx185sqmm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KVgrade of following size direct in ground in the same trench in one tier horizontal formationincluding excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS 1255: 1983 amended upto date
1Rx1Cx500sqmm
1Rx3Cx300sqmm
1Rx3Cx185sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size in the existing masonry open duct as required.
1Rx1Cx500sqmm
1Rx3Cx300sqmm
1Rx3Cx185sqmm
HT-End Termination & Joints
Supplying and making outdoor cable end termination with heat shrinkable jointing kit confirming to IS 13573 (Part 2) : 2011 completewith all accessories including lugs suitable for following size of XLPE aluminium conductorcable of 11 KV grade as required :
1Cx500sqmm
3Cx300sqmm
3Cx185sqmm
Supplying and making outdoor straight through cable jointing with heat shrinkable jointing kit confirming to IS 13573 (Part 2) : 2011 complete with all accessories including ferrules suitable for following size of XLPE aluminium conductor cable of 11 kV grade as required.
1Cx500sqmm
3Cx300sqmm
3Cx185sqmm
LT Cable
Supply of following sizes A2XFY FRLS Aluminium conductor armoured power cables of 1.1kV grade confirming to IS 7098 (Part I) amended upto date
3.5x400 Sqmm A2XFY (Aluminium) Cable
3.5x300 Sqmm A2XFY (Aluminium) Cable
3.5x240 Sqmm A2XFY (Aluminium) Cable
3.5x185 Sqmm A2XFY (Aluminium) Cable
3.5x120 Sqmm A2XFY (Aluminium) Cable
3.5x95 Sqmm A2XFY (Aluminium) Cable
3.5x70 Sqmm A2XFY (Aluminium) Cable
3.5x50 Sqmm A2XFY (Aluminium) Cable
4x16 Sqmm A2XFY (Aluminium) Cable
4x10 Sqmm A2XFY (Aluminium) Cable
4x6 Sqmm A2XFY (Aluminium) Cable
4x4 Sqmm A2XFY (Aluminium) Cable
3x4 Sqmm A2XFY (Aluminium) Cable
Laying of one number A2XFY / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.
Above 185 sq. mm and upto 400 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Upto 35 sq. mm
Laying of one number A2XFY/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 185 sq. mm and upto 400 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Upto 35 sq. mm
LT- End Termination
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5x400 Sqmm A2XFY (Aluminium) Cable
3.5x300 Sqmm A2XFY (Aluminium) Cable
3.5x240 Sqmm A2XFY (Aluminium) Cable
3.5x185 Sqmm A2XFY (Aluminium) Cable
3.5x120 Sqmm A2XFY (Aluminium) Cable
3.5x95 Sqmm A2XFY (Aluminium) Cable
3.5x70 Sqmm A2XFY (Aluminium) Cable
3.5x50 Sqmm A2XFY (Aluminium) Cable
4x16 Sqmm A2XFY (Aluminium) Cable
4x10 Sqmm A2XFY (Aluminium) Cable
4x6 Sqmm A2XFY (Aluminium) Cable
4x4 Sqmm A2XFY (Aluminium) Cable
3x4 Sqmm A2XFY (Aluminium) Cable
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription"11kV UG Cable", bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground at every 100m interval.
Supplying and laying 40mm dia HDPE PLB pipe duct with coupling collars for drawing optic fiber pilot wire through the PLB pipes as per drawing and as per direction of Technopark Officials, in the existing trench already made for laying 11kV UG Cable as per direction of Technopark
Supply, laying and commissioning of fibre optical cable (24 fibre) from cable drums and laying through the 40mm PLB HDPE pipe carefully and neatly including loops, termination,supply of suitable terminal boxes, joint enclosures and connectors etc. complete on standard specifications and directions of Technopark officers at site
LT Works
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
2Rx1.5sqmm with 1R 1.5sqmm Green wire for earthing
2Rx2.5sqmm with 1R 1.5sqmm Green wire for earthing
2Rx4sqmm with 1Rx1.5sqmm Green wire for earthing
3Rx4sqmm
4Rx4sqmm with 1Rx1.5sqmm Green wire for earthing
3Rx6sqmm
Cat 6 cable
Supplying and fixing of 20mm of medium class PVC conduit along with accessories in surface/recess including cutting the floor/ wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface/recess including cutting the floor/ wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 20mm of PVC flexible conduit along with accessories in surface
Supply and Fixing of 20mm ISI medium class PVC casing and capping of following dimensions along with accessories through wall in surface/ceiling
Supply and Fixing of 25mm ISI medium class PVC casing and capping of following dimensions along with accessories through wall in surface/ceiling
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for two light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for three light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for four light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for five light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supply and Installation of Independent plug point with 6A 3 pin plug socket controlled by 6A switch with suitable modular plate, GI box/PVC box in recess/ surface
Supply and installation of combined modular plug point for 6A, 3 pin plug socket controlled by 6A modular switch in the same switch board with suitable modular plate, GI box/PVC box in recess/ surface
Supply and Installation of Independent plug point with 16A plug socket controlled by 16A switch with suitable modular plate ,GI box/PVC box in recess/ surface.
Supply and Installation of Computer Socket(R-J45 jack) with suitable modular plate , GI box/PVC box in recess/ surface.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 100 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
3P 4W VDB Double Door
3P 6W VDB Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3P 4W VDB Double Door
3P 6W VDB Double Door
Supplying and fixing following 63 A four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following 40 A double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 32A, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 32A, four pole, 415 V, isolator with metallic enclosure with connections, testing and commissioning etc. as required
Supplying and fixing 40A, four pole, 415 V, isolator with metallic enclosure with connections, testing and commissioning etc. as required
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commisioning.
5A to 32A ,SP MCB
5A to 32A ,FP MCB
40A ,TP MCB
MCB Blanking plate
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of LED recess mounted down light with minimum lumen outout of 500 Lumen, PC defuser, CRI>=80PF>=0.95 ,CCT >=5700 K ,Efficacy >=100 lm/W, THD<=10%, constant current electronic driver should be equipped with surge protection upto 2kV
Supply and fixing of LED Surface mounted down light with minimum lumen outout of 1400 Lumen, PC defuser, CRI>=80PF>=0.95 ,CCT >=5700 K ,Efficacy >=100 lm/W, THD<=10%, constant current electronic driver should be equipped with surge protection upto 2kV
Supply and fixing of LED recess mounted down light with minimum lumen outout of 500 Lumen, PC defuser, CRI>=80PF>=0.95 ,CCT >=5700 K ,Efficacy >=100 lm/W, THD<=10%, constant current electronic driver should be equipped with surge protection upto 2kV
Supply and fixing of LED recessed ceiling fixture 600X600mm with a minimum lumen output of 2400 lumens ,CRI >= 80,PF>=0.95, ,CCT>= 5700K, Efficacy>=110 lm/W, THD<=10%, constant current electronic driver should be equipped with surge protection upto 2kV
Supply and fixing of recessed PIR Motion Sensor, sensing radius >= 2.5 meter
LIGHTNING PROTECTION SYSTEM
Horizontal Run
Supply and fixing of 8mm Aluminium Round Conductor meeting the requirements as per DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) with polyamide conductor holders for flat roof with holding base placed at every 1m, polyamide conductor holder at parapet placed every 0.7m apart, cross universal connectors including 4 hexagonal bolts, expansion pieces at every 20m of the conductor, connectors required for the expansion piece connection etc and with all other accessories for complete installation.
Air Terminals
Supply and fixing of 4 mtr Vertical Air Terminal as per IEC -62305 part-3 & DIN EN 50164-2 with 16mm Al rod tapered to 10 mm Al rod suitable for high wind load with all required accessories including suitable clamps, connectors etc for complete installation.
Supply and fixing of 2 mtr Vertical Air Terminal as per IEC -62305 part-3 & DIN EN 50164-2 with 16mm Al rod tapered to 10 mm Al rod suitable for high wind load with all required accessories including suitable clamps, connectors etc for complete installation.
Vertical Run
Supply and fixing of 8mm Aluminium Round Conductor meeting the requirements as per DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) with necessary conductor holders with holding base placed at every 1m, test joints suitable to connect 8mm round conductor with 30x3 mm GI earth strip etc and all other required accessories for complete installation.
Earthing System
Supplying and fixing of 30x3 mm GS flat strip with zinc coating of 500gm/sq.m (70 micron min) tested for lightning protection system and as per DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) with necessary cross connector, spacer clip,plastic corrossion protection strip, clamps etc with all required accessories for complete installation
Supply and fixing of CPRI tested maintenance free ,low carbon copper coated earth electrode of 3 metre having diameter of 14.2 mm withcopper coating thickness of 250 micron and tested as per IEC 62561-2 with necessary clamps, chemical compound (IEC 62561-7), Polypropylene & Polyethylene (UFE) Inspection Chamber with heavy duty cover of dimension 300x300mm (weight bearing capacity of 50kN) and with all accessories required for complete installation.
Miscellaneous
Supply and erection of vertical and horizontal type cable trays and cable supports fabricated out of MS angles (ISA) and MS flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with two coats of Zinc Chromate primer and two coats of enamel paint. (Size as specified by Technopark as per site conditions)
Supplying and installing following size of perforated pre-painted M.S. cable trays with black finish with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Earthing with G.I. earth plate 1200 mm x1200 mm x 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with all accessories as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
SITC of 10kVA, 3-phase pure sine wave inverter with 2 nos of 150AH Tubular Battery, Stand etc with all accessories.
Supply of CO2 Extinguisher 4.5Kg, Fire rating of 55B, PESO approved Aluminium cylinders with CCOE certification, IS 15683:2018 standard, Certifications from BIS, EN, CE, ISI and date of manufacture imprinted on cylinder, coated with High Glossy PU Paint, anti corrosive make, Discharge hose with the conductive wires to dissipate the static charge generated during CO2 discharge, Carbon dioxide gas having a purity of 99.5% and conforming to IS15222, “D” handle for ease of carrying and operator safety, Cold impact extrusion can, Used-Unused Mechanism, Squeeze Grip, Gross Weight 11.16 Kg, Empty Weight 6.66Kg, Can Height 860mm, Diameter 140mm, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2m, two piece floating spindle valve with a handwheel to operate, venyl sticker/label with all the details including operational instructions, 10 years warranty
Supply and providing 3.3kV, 2mm thick synthetic type and 1 m wide electrical grade chequered type mat confirming to IS 15652 (2006)
Supply and providing 11kV, 2.5mm thick synthetic type and 1 m wide electrical grade chequered type mat confirming to IS 15652 (2006)
Supplying, Fixing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Supplying and Providing 15" long rubber hand gloves 15 kV
Supply & fixing neatly laminated electrical schematic drawings on good frame work.
Preparation of all drawings submitting and getting approval and Sanction for Energisation from Kerala State Electrical Inspectorate by a Licensed A Class Electrical Contractor for the electrification of proposed commercial building, load additions and modification works which includes current additions in the existing RMU network, submitting of Completion certificates and arranging inspection, getting sanction and energization certificate etc., providing and fixing neatly Laminated Electrical schemes and layout for Commercial building .
GERESH ELECTRICALS PVT. LTD
IDEAL DATACOM NETWORK AND ELECTRICAL SOLUTIONS PVT LTD
Fathima Engineering Co. Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .