| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹2.6 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.6 Cr+₹5.3 L (2.06%)Rejected-Finance | ₹2.6 Cr+₹5.3 L (2.06%) | L2 | Rejected-Finance HIGH BID VALUE |
| 3 | L3₹2.8 Cr+₹25.3 L (9.75%)Rejected-Finance GANGA NAGAR NEAR TUSHARCHAKRA MISAMARI 784506 | SONITPUR | ASSAM | 784506 | ₹2.8 Cr+₹25.3 L (9.75%) | L3 | Rejected-Finance HIGH BID VALUE |
| 4 | Rejected-Technical | - | - | Rejected-Technical NO in WLR, vide HQ ADG (NEI) Guwahati letter No 80017/ADG NEI/WLR/D to S)/852/E8 dt 30 Oct 2024. Thus, bid rejected. |
| 5 | Rejected-Technical | - | - | Rejected-Technical The firm did not fulfil the criteria as per NIT Para 8 (b), Para (f) (iii) to (vi) at Ser Page No 10 and also Para (h) at Ser Page No 12 of Notes of Appx A. GST Suspended. Thus, bid rejected. |
Tender Value
₹2.9 Cr
EMD Value
₹3.7 L
Closing Date
30 Oct 2024, 6:00 pmClosed
COL SUNIL PILLAI
HQ CWE TENGA PIN-900194 C/o 99 APO
CONSTRUCTION OF INFRASTRUCTURE FOR SHAURYA AT AIR FORCE STN MISSAMARI UNDER GE MISSAMARI
2024_MES_676584_1
8482/E8
Open Tender
Civil Works
Item Rate
270 days
GE MISSAMARI
B (a) (v)
8 documents required · 8 mandatory
₹2,000
GE MISSAMARI
₹3.7 L
Yes
9 Dec 2024
25 Sept 2024
6 Nov 2024
25 Sept 2024
30 Oct 2024
16 Oct 2024
Amount
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm complete all as specified and as directed.
Excavation over areas (using Mechanical Means/Manual Means), n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, remming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and as directed
M&L for Rolling and consolidating formation surfaces in cutting/Filling using power roller exc 8 tonne but n exc 12 tonne complete all as specified and as directed.
M&L for bringing approved earth from outside MOD land from a distance of exc 5 km but n exc 10 km from the proposed site and forming embankment including raising earth, spreading in layers n.exc 25 cm thick, watering, ramming/rolling with tandem vibratory roller (static and vibratory) under Optimum Moisture Condition (OMC) to 98% modified proctor density and finished to required gradiant size and camber as required, complete all as specified and as directed. Note:- (i) Consolidated embankment shall be measured and paid with admissible allowances as per SSR- 2020 (Pt -II) (ii) Proper pay receipt/challan of earth purchased from outside of MoD land shall be submitted by the contractor before payment of RAR/Final Bill.
M&L soling (or sub base) 100mm thick (spread thickness) with broken boulders or quarried stone, interstices filled, surfaces formed and rolled and consolidated with 8 to 12 tonne power roller to gradient and camber required complete all as specified and as directed.
M&L WBM 15 cm thick in two layers of 7.5cm thick each (compacted thickness) with coarse aggregate with lime stones, sand stones, flint or quartize of grading 2 (63 mm to 40mm size) spead, rolled and consolidated with 8 to 12 tonne power roller to gradient and camber required all as specified and directed.
M&L for continuous brick edging with burnt clay bricks of Sub class B of old size; with width equal to the depth of the brick, laid on end vertically complete all as specified and directed.
M&L for applying evenly a tack coat of Cationic Bitumen Emulsion (RS-1) conforming to IS: 8887 at a rate of application of 0.2-0.3 kg/sqm on bituminous surface as specified in Table 500-5 of MORTH specification for road and bridge works 2013, using mechanical sprayer after cleaning of existing surface complete all as specified and directed.
M&L for applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0.7-1 kg/sqm on surface of WMMIVVBM as specified in Table 500-3 of MORTH specification for road and bridge works 2013, using mechanical sprayer complete all as specified and directed
M&L for laying one layer of premix bituminous macadam of 50mm thick (Compacted thickness) using crushed aggregate of grading II of IRC laid/rolled and compacted with mechanical paver to required gradient and camber complete all as specified and directed.
M&L Bituminous premix Semi asphaltic dense concrete 40mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient complete rolled with 8 to 10 tonnes power roller complete all as specified and as directed.
M&L for 3.00 mm thick painting to road surfaces as in lines, dashes, arrows, letters, zebra cross etc, on roads, pavements and the like etc with thermoplastic road marking paint (Make : STP or equivalent as approve by E' in C' branch make) @ 5 Kg/Sqm and applying glass grit @ 300 gms/Sqm over painted surfaces while the painting surfaces are hot including cleaning surfaces complete all as specified and directed. (both application shall be carried out through meachanical application by the approved applicator of manufacturer of paint).
Supply and installation of Raised Pavement Marker (RPM) with polycarbonate lens electronically welded with the RPM body. The marker shall be scratch proof and abrasion resistant microprismatic polycarbonate lens with polycarbonate reflective panels with dual prismatic cubescapable providing total internal reflection. Dimension: The dimension of the marker is height 15.88mm, width 101.6mm, length 89.2mm. The marker conforms to ASTM D4280 and is in accordance with MORTH circular reference No. RW/NH 33023/10/97-DO III dated 11 June 1997. Marker shall be fixed with adhesive and no nails shall be used to affix the marker and shall be marked with manufacturer name complete all as specified and as directed.
S&F cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm made of with PAMA striplens reflector of model N DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions complete all as specified and as directed.
M & L excavation in trenches not exceeding 1.5 M wide and n. exc 5mt in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L Returning filling in incl spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
M&L Plain cement concrete in foundation filling and Mass concrete type D-2 (1:4:8) as on foundations of brick wall complete all as specified and as directed.
M&L Cement concrete in foundation filling and Mass concrete type B2 1:2:4 40 mm graded aggregate as in bed of Hume pipe.
M&L Reinforced concrete pipes 600mm bore class NP2 laid and jointed complete with collars
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) as in wall.
M&L Cement concrete as in lintel upto 1.5m clear span, cills steps sesmic and the similar bands plinth course, string (cours lacing courses, parapets coping kneelers, apox stone and the like incl weather etc type B1 (1:2:4) (20 mm graded aggregate) complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of Brick work of concrete surface in cement mortor 1:4 finished fair & even complete all as specified and as directed.
M&L Two coats of cement base paint over one coat of primer incl preparation of surface complete all as specified and as directed.
Supply & Fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (09 metres long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint and Pole No. duly painted complete all as specified and directed.
Supply & Fixing street light bracket made of 32mm dia GI Pipe light grade upto 1.2mtr including two pairs of clamps made out of flat iron 40mm X6mm of sutable length complete all as specified and directed.
S& F energy saving new generation environmental friendly long life verssatile pressure die cast allumnium IP 66 security light fittings luminaire with high power LEDs as light source & electronic drivers of capacity 60 watts with pre wired and necessary mounting arrangement & testing complete all as specified and directed.
Supply & Fix thermoplastic cable junction box for street lights of size 200x160x98 mm including terminals for cable connection with IP 66 protection duly fixed in poles with the help of clamps nut bolts arrangement complete all as specified and directed.
S & F in replacement PVC insulated weather proof sheated copper cable 1.5 sq mm 3 core in steel conduit from junction box to street light duly properly fixed complete all as specified and directed.
M&L Cement Concrete 1:2:4 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations etc, or for shafts, wells, cesspits, man holes, pier holes etc not exc 10 sq m on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning for cable protection using clean dry sand complete all as specified and directed.
Supply & Laying well burnt brick , locally available best quality (sub class "B" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified.
S & F GI Tubing light grade of size 40mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion . (NOTES : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level).
Supply and fixing Timelite Distribution Boards for automatic Switching of street lights suitable for 32Amps,4 Pole 230 volt fited with digital ASTRONOMICAL time switch 24 hrs operation,3 pole contactor 40 Amps,and TPN MCB 32 Amps , indication lamp Auto / Manual Function of Capacity 6 KW including fixing with MS Clamp40X5 mm to steel/RCC poles incl connection complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core complete all as specified and directed.
Supply laying & testing cable XLPE insulated,earthed, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 6.35/11KV volts, grade cross sectional area 95 sq. mm 3 core conforming to IS 7098 complete all as specified and directed.
Supply & Fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 metres long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and directed.
M/L in replacement for cross arms, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified and directed.
M & L for stay assembly in replacement comprising of 7/2.24mm galvanised MS stranded wire of required length fixed to pole with and including flat iron clamps fabricated out of 50 x 6mm flat iron and iron nuts, bolts and washers of suitable size, 40 cm long 14 mm dia galvanised MS stay bow, 215 cms long 20 mm dia stay rod threaded end with nuts and washers, MS stay plate galvanised 230 x 230 x 6mm, two thimble, loop insulators of size 65 x 90mm, clearance dia of hole 16 mm complete all as specified and as directed Note :- Excavation and earth work and PCC for foundation shall be measured and paid separately.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm Outdoor type
Supply and install HT 11 KV outdoor type gang operated air-break switch , mechanically operated mounted on insulater and steel frame ,with operating mechanism worked from ground level suitable for vertical mounting of rating 200 Amps complete all as specified and directed .
Supply and fix expulsion fuse, Triple pole, channel type/drop out type suitable as per site reqmt with working pressure 11 KV grade of capacity upto 200 Amps compete all as specified and as directed ( With Six insulator)
Supply and fix lightning arrestor complete with all fittings discharge capacity 65kA suitable for 11000V complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV, type - I, flat, size 300 x 180 x 40 mm all as specified and directed.
Supply laying & fixing GI Pipe light 80mm dia , ISI marked ,of required length for protection of cables in wall/pole/under road complete including necessary MS clamps , nuts , bolts & washers etc all as specified and directed.
Taking down the existing unservicable LT UG cable of any size any type/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed
Dismantling the existing LT external electricfication system consisting of Steel tubular Poles including PCC and removal of debris from site complete all as specified and directed .
Dismantling and taking down Overhead Conductor (ACSR) of any size from LT/HT Poles.
Dismantling and taking down old MS Channels & GI wire of any size from pole duly unscrewing from poles from clamps nut bults and washers complete all as specified and directed
Dismantling and taking down old Stay from LT poles duly unscrewing from poles complete all as specified and directed
Dismantling old GI Pipe any size any type complete all as specified and directed.
Supply and fix UG cable route indicator made out of PCC(1:3:6) of size 45 X 30 X 10 Cm blocks writing MES HT CABLE , direction of cable, class/voltage rating for HT complete all as specified and directed.
Dismantling Unreinforced Cement Concrete any type in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and diected
KESHAV ENTERPRISES (BID ID -3146933)
M/S K.K.TRADERS (BID ID -3147486)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .