Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | ₹35.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹36.7 L+₹1.5 L (4.29%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹36.7 L+₹1.5 L (4.29%) | L2 | Rejected-Finance Other then Lowest Bidder |
| 3 | L3₹37.2 L+₹2.1 L (5.88%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹37.2 L+₹2.1 L (5.88%) | L3 | Rejected-Finance Other then Lowest Bidder |
| Sl No | Description | Qty | Unit | KAPOOR ELECTRICALS L2 | V r traders L3 | trinity construction L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. | 213.2 | Cum | 90 ₹19,188 Lowest | 299 ₹63,746.8 | 150 ₹31,980 |
| 2.00 | Description same as per item No 01 above but for each
additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and directed. | 3.46 | Cum | 110 ₹380.6 Lowest | 399 ₹1,380.54 | 200 ₹692 |
| 3.00 | Returning, filling in, soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 144.18 | Cum | 10 ₹1,441.8 Lowest | 49 ₹7,064.82 | 200 ₹28,836 |
| 4.00 | Removing excavated material soils n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. | 72.58 | Cum | 10 ₹725.8 Lowest | 49 ₹3,556.42 | 10 ₹725.8 Lowest |
| 5.00 | M&L un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. | 2,777 | Each | 25 ₹69,425 Lowest | 39 ₹1,08,303 | 25 ₹69,425 Lowest |
| 6.00 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed.
Note:- Punned thickness shall be considered for payment purpose. | 40.5 | Cum | 550 ₹22,275 | 1,499 ₹60,709.5 | 500 ₹20,250 Lowest |
| 7.00 | M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregate, as in coping of poles and stay assembly etc with necessary form work complete all as specified and as directed. | 2.16 | Cum | 2,200 ₹4,752 Lowest | 3,999 ₹8,637.84 | 4,500 ₹9,720 |
| 8.00 | M&L for PCC (1:3:6) type C2, using 40 mm graded stone aggregate, in stay assembly etc with necessary form work complete all as specified and as directed. | 6.6 | Cum | 2,300 ₹15,180 Lowest | 2,999 ₹19,793.4 | 4,000 ₹26,400 |
| 9.00 | M&L for PCC (1:4:8) type D2, using 40 mm graded stone aggregate, in pole foundation complete all as specified and as directed. | 3.46 | Cum | 2,300 ₹7,958 Lowest | 2,499 ₹8,646.54 | 3,500 ₹12,110 |
| 10.00 | M&L for disconnecting Transformer 11/0.433 KV of capacity 250 KVA to 500 KVA, removal of incoming & outgoing electric connection and taking down carefully from four pole/two pole structure/platform, shifting to workshop draining out transformer oil, opening of top frame taking out the core from the tank, dismantling core into the parts cleaning the tank and removing out the dust particles refixing the same after necessary realignment and heat treatment, connecting all the electric connections and making the Transformer absolutely leak proof, refilling the Transformer oil, testing the Transformer at workshop, transporting back to site and fixing to position as directed, making all electrical and earth lead connection commissioning and testing of Transformer on load at least for 12 hours, re-installing the transformer and making connection complete all as directed .
Note: (i) Transportation of Transformer shall be included in the quoted rate only
(ii) Cost of glass Sleeves/ ebonite sleeves insulating material tapes etc shall be included in the quoted rate only.
(iii) Rewinding of HT/LT coils, cork sheet for top cover gasket, new brushing bush rod tap changer gear shall be measured and paid for separately under relvant item. | 4 | Each Job | 400 ₹1,600 Lowest | 6,999 ₹27,996 | 2,000 ₹8,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Jun 2026, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
REPAIR/MAINT OF 33/11 KV MRS, HT BREAKERS, HT UG CABLES, TRANSFORMERS AND ALLIED HT ELECTRICAL WORKS UNDER GE CLEMENT TOWN, DEHRADUN.
2026_MES_768026_1
85460/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE Clement Town
Class D Cat b (ii)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town Dehradun
₹90,000
Yes
27 Aug 2026
26 May 2026
25 Jun 2026
26 May 2026
17 Jun 2026
11 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. | 213.2 | Cum | 33.5 | ₹7,142.2 |
| 2 | Description same as per item No 01 above but for each
additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and directed. | 3.46 | Cum | 33.5 | ₹115.91 |
| 3 | Returning, filling in, soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 144.18 | Cum | 33.5 | ₹4,830.03 |
| 4 | Removing excavated material soils n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. | 72.58 | Cum | 33.5 | ₹2,431.43 |
| 5 | M&L un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. | 2,777 | Each | 33.5 | ₹93,029.5 |
| 6 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed.
Note:- Punned thickness shall be considered for payment purpose. | 40.5 | Cum | 1,572 | ₹63,666 |
| 7 | M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregate, as in coping of poles and stay assembly etc with necessary form work complete all as specified and as directed. | 2.16 | Cum | 4,144.4 | ₹8,951.9 |
| 8 | M&L for PCC (1:3:6) type C2, using 40 mm graded stone aggregate, in stay assembly etc with necessary form work complete all as specified and as directed. | 6.6 | Cum | 4,144.4 | ₹27,353.04 |
| 9 | M&L for PCC (1:4:8) type D2, using 40 mm graded stone aggregate, in pole foundation complete all as specified and as directed. | 3.46 | Cum | 4,144.4 | ₹14,339.62 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender85460.pdf
Tender Documents • 1.19 MB
BOQ_860090.xls
BOQ • 0.48 MB
85460.pdf
PDF • 0.11 MB
85460DATECORRIGENDUM.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .