Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | ₹6.1 L Quoted ₹6.3 L | L1 | Accepted-AOC being L1 |
| 2 | L2₹6.9 L+₹60,407 (9.53%)Rejected-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹6.9 L+₹60,407 (9.53%) | L2 | Rejected-AOC being L2 |
| 3 | L3₹7.0 L+₹62,840 (9.91%)Rejected-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | ₹7.0 L+₹62,840 (9.91%) | L3 | Rejected-AOC being L3 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
10 Jul 2023, 6:00 pmClosed
AGE I Cannanore
AGE I Cannanore HQ Hospital Kannur PO 670017
Repairsto internal electrifications and misc works to certain Offrs md accn and repairs to ceiling fan, exhaust fan, geyser etc of Mily Station Kannur under AGE (I) Cannanore.
2023_MES_602928_1
8279
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Cannanore
Category E b (i)
8 documents required · 8 mandatory
₹500
AGE I Cannanore
₹16,000
Yes
25 Aug 2023
13 Jun 2023
15 Jul 2023
14 Jun 2023
10 Jul 2023
27 Jun 2023
14 Jun 2023 - 20 Jun 2023
Amount
Taking down carefully copper/aluminium point wiring of light, fan, socket or power complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of walls, floor ceiling etc. all as directed
M&L Point wiring complete with 1.5 Sq mm single core PVC insulated unsheathed copper conductor FRLS cable multi stranded 1100 Volt grade drawn through and including non metallic rigid PVC conduit concealed to wall and fixed to ceiling/roof etc with necessary fixing accessories such as bend elbow socket etc with fixing material including terminal box made out of 1.22mm thick MS sheet concealed in wall covered with bakalite/plastic laminated sheet top cover of 3mm thick cadmium plated screws with cup washer including 1.5Sqmm single core PVC insulated un sheathed copper conductor FRLS cable multi stranded 1100Volt grade as earth continuity conductor green in colour connected to common earth dolly complete all as specified and as directed for One light/fan/bell point controlled by one switch. Note : (a) wiring shall be done by using colour code ie. Red, Yellow, Blue and earth wire shall be green colour. (b) quoted rate included cutting chases for fixing conduit.
All as per item No 2 here in before but controlled by two way swith all as specified and directed.
All as per item No 2 here in before but for One 3 Pin, 5 Amps socket on same board with other switches all as specified and directed.
All as per item No 2 here in before but for One 3 Pin, 5 Amps switch socket combination on independent board all as specified and directed.
All as per item No. 2 on here in before but for one 3 pin 15 amp switch socket combination on independent board with 2.5Sqmm unsheathed PVC insulated copper conductor FRLS cable including 2.5 Sqmm PVC insulated copper cable for earth continuity conductor complete all as specified.
Taking down old unservicaeble submain wiring any size cable including conduit , batten etc and making good disturbed surfaces of walls, floor ceiling etc. all as directed
S & F switch piano flush type, single pole, one way, 5 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F switch piano flush type, single pole, two way, 5 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F PVC ceiling rose round shape, three terminals, polycarbonate, isolated body including connecting up electrically all as specified and as directed.
S & F socket 5pin 5/6 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F switch piano flush type, single pole, one way, 15 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F socket 5pin 5/15 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F switch bell push, flush type, 240 Volts, single pole, 5 Amps including connecting up electrically all as specified and directed.
S&F stepped type electronic fan regulator, full rotation, 200W, SP, 230V connecting up electricallyall as specified and directed.
Taking down unserviceable fluorescent tube light fittings and fixing only LED light fittings with extruded polycarbonate, heat sink, environmental friendly, energy efficient ready to use pack of 4 feet 20 W, LED batten, 6500K, and including connecting up with twin core twisted copper flexible conductor cable of sutibale size all as directed. Note : LED light fittings shall be issued at MES yard for free for fixing.
Taking down unserviceable fluorescent tube light fittings and fixing only LED light fittings with extruded polycarbonate, heat sink, environmental friendly, energy efficient ready to use pack of 2 feet 10 W, LED batten, 6500K, and including connecting up with twin core twisted copper flexible conductor cable of sutibale size all as directed. Note : LED light fittings shall be issued at MES yard for free for fixing.
Taking down unserviceable light fittings, Supply and fixing of Recessed/Surface mounting 36W LED luminaire, prewired with white powder coated CRCA housing with LEDs and fully window acrylic diffuser, suitable for 600x600mm E-grid/POP/ false ceiling of Bajaj cat part No BZSSQL36WLEDG54WH or equivalent in crompton/Havells complete with all accessories making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
M&L for sub main wiring with two runs of single core 6 Sq mm copper conductor FRLS cable, ISI marked, PVC insulated, unsheathed multistanded, 1100 V grade drawn through and including non metallic rigid PVC conduit 25mm dia, ISI marked with all accessories such as bend,elbow,socket,tee saddles etc fixed concealed to wall / fixed to ceiling, including cutting chases etc including 6 Sq mm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100 V grade as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note :- (i) 3 runs of 6 Sq mm copper cable and one run of PVC conduit will be measured as one length. (ii) wiring shall be done by using colour code ie. Red, Yellow, Blue and earth wire shall be green colour.
S & F MCB TPN, 430 Volt, 63Amps, B serious, breaking capacity 10KA including electrically connecting up using wiring lugs all as specified and directed.
S & F MCB SPN, 430 Volt, 40 to 63Amps, B serious, breaking capacity 10KA including electrically connecting up using wiring lugs all as specified and directed.
S & F MCB SP, 240 Volt, 6 to 32Amps B serious breaking capacity 10KA including electrically connecting up using wiring lugs all as specified and directed.
S & F sheet metal powder coated enclosure factory made for MCB DB, SPN 8 way with 200 Amps bus bar, 240 Volt, double door type, conform to IS 13032-1991 fixed/flushed on wall including electrically connecting up and taking down old unserviceable DB complete all as specified and directed.
S & F sheet metal powder coated enclosure factory made for MCB DB, SPN 12 way with 200 Amps bus bar, 240 Volt, double door type, conform to IS 13032-1991 fixed/flushed on wall including electrically connecting up and taking down old unserviceable DB complete all as specified and directed.
S & F sheet metal powder coated enclosure factory made for MCB DB, TPN 4 way with bus bar, 440 Volt, double door type, fixed/flushed on wall including electrically connecting up and taking down old unserviceable DB complete all as specified and directed.
S & F in replacement of LED Lamp 15 Watt complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular switch 6 A, 1 module, including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular switch 16 A, 1 module, including connecting up electrically complete all as specified and directed.
Modular Bell push 6A 1 module,including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular Socket 6A - 2/3 pin combined 2 module, including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular socket 6A/16A - 2/3 pin combined, 2 module, including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular ceiling fan regulator including connecting up electrically complete all as specified and directed.
M&L for Earthing complete with using GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be redone by the contractor at no extra cost to Govt).
S& F calling bell electric AC 240V, single pole, ding dong type and connecting up electrically all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings nd electrically connecting up all as directed.
Taking down carefully geyser 25 to 50 ltrs capacity from wall after unscrewing nuts/bolts etc and refixing in same position after repair and replacement of unserviceable spare-parts including dismantlling, assembly of water storage tank and testing Complete all as specified and directed by Engineer-In-Charge. NOTE :- Supply and Replacement of Spare componants shall be measured and paid separtely under the relevant items.
S&F Thermostat (ISI Marked) suitable for geysers 25 -50 Ltrs capacity, AC 230 volt, adjustable range from 0-90 degree Celsius. Complete including dismantling of unserviceable thermostat all as specified and directed by Engineer-In-Charge.
S&F in replacement of old unserviceable fusible plug (ISI Marked) suitable for 25 to 50 Ltrs capacity Geysers Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable Syphon assembly of 06 holes/ 09 holes (ISI Marked) made out of brass suitable for 50 ltr capacity geyser including necessary studs, screws and rubber gasket/washers etc Complete all as specified and directed.
S&F in replacement of old unserviceable Syphon assembly of 06 holes / 09 holes (ISI Marked) made out of brass suitable for 25/35 ltr capacity geyser including necessary studs, screws and rubber gasket/washers Complete all as specified and directed.
S&F in replacement of old unserviceable valve (ISI Marked) suitable for 25 to 50 Ltrs capacity geysers Complete all as specified and directed.
S&F in replacement of old unserviceable heating element titanium coated of rating 1.5 Kw suitable for water heater storage type any make and type as required at site including rubber washers (ISI marked) Complete all as specified and directed. Make : Bajaj/ Hot Zone/Theeta/Daspas/Airex
S&F in replacement of old unserviceable heating element titanium coated of rating 2.0 Kw suitable for water heater storage type any make and type as required at site including rubber washers (ISI marked) Complete all as specified and directed. Make : Bajaj/ Hot Zone/Theeta/Daspas/Airex
S&F in replacement old unserviceable 1.8 mm thick (18 gauge) stainless steel water tank with 0.7 Mpa bar pressure, suitable for geyser 25 ltr capacity complete with rubber gasket, Complete all as specified and directed.
All as per item No 44 here in before but suitable for geyser 50 ltr capacity complete with rubber gasket, Complete all as specified and directed. Notes for item No 44 &45 :- (i) The tank shall be tested at site and shall be able to withstand requisite pressure, necessary arragengments for the testing shall be made arranged by the contractor. (ii) Tank with stud type and round element shall only be provided.
S&F in replacement Geyser connection pipes for hot and cold water supply made of stainless steel wire braided connector with chrome finish heavy duty nuts of 15mm size with suitable lengh including taking down of old unserviceable pipes complete all as specified and directed.
M & L for Replacement of old unserviceable thermal insulation material non hygroscopic, fire resistant, fiber glass wool for 25-50 ltrs capacity geyser complete all as specified and directed by Engr-in-Charge
M & L for preparing the old painted steel surfaces by rubbing/scratching the old painting of 25 ltrs capacity geyser and painting with two coats of synthetic enamel paint, white with spray gun including writing MES Nos with black paint (of required size and shape) complete all as specified and directed by Engineer-in-Charge.
All as per item No 48 here in before but for geyser 50 ltr capacity complete all as specified and directed.
S&F in replacement Sheet metal enclosure single pole and neutral with a two pin, earth plug and socket with one double pole MCB of 20 Amp ,240 Volt Complete all as specified and as directed by the Engineer-in-charge.
S&F in replacement Indicator lamp (green & red ) with Neon lamp (ISI Marked) indicating automatic working of geyser round/square type suitable for geyser capacity 25/50 ltr AC 230 volt Complete all as specified and as directed by the Engineer-in-charge
S&F in replacement of anchor bolt of size 12mm x 100mm long with washer including drilling holes for fixing anchor bolt and making good to the disturbed surface matching with specification complete all as specified and as directed by the Engineer-in-charge.
M & L for Descaling of geyser of capacity 25litre /50litre after unscrewing nuts/bolts and taking down from wall and refixing in position after repair including strip opening the assembly, de-scalling the syphon assembly, steel tank and incoming and outgoing water connection complete and testing all as specified and as directed by the Engineer-in-charge.
M & L PVC cable insulated and overall sheathed copper conductor cord flexible wire , multistranded 1100 volt grade of size 2.5 sqmm, 3 core ( ISI Marked ) complete all as specified and as directed by the Engineer-in-charge.
M&L for taking out old unserviceable ceiling fans from site and removal of burnt winding wire by cutting, clening slots and re-Winding of AC ceiling fan motor 1200/1400 mm of any make with super enameled copper winding wire 350 gm per fan of existing gauge varnishing with E class insulation varnish, threading, including neceassry laith work and refixing in same location, connnecting up electrically with appropriate size copper conductor cable upto connector block Complete all as specified and directed by Engineer-In-Charge . Notes:- (i) Doctor brand or equivalents ISI brand varnish shall be used. (ii) Motor winding shall be wound with machine only. (iii) BIC/HTP or DEVIDYAL. make super enameled copper winding wire shall only be used. (iv) Weight of copper winding wire per fan shall be min 350 gm.
All as per Srl item No 55 here-in-above but weight of copper winding wire shall be above 500 gram per fan of size 1400 mm sweep complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work Complete all as specified and directed by Engineer-In-Charge .
S&F replacement of old unserviceable capacitor AC 230 volts 2.5 mfd (ISI marked) Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable capacitor AC 230 volts 3.15 mfd (ISI marked) Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable capacitor AC 230 volts 4.00 mfd (ISI marked) Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable ball bearing of size 6200 to 6204 including neceassry laith , Grinding and welding work Complete all as specified and directed by Engineer-In-Charge . Make NBC/SKF
S&F in replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep Complete all as specified and directed by Engineer-In-Charge
S&F in repalcement of old unserviceable down rod of ceiling fan of 20 mm bore "medium grade" with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) in white/brown colour (fully furnished) Complete all as specified and directed by Engineer-In-Charge.
Material and Labour for Servicing of ceiling fans of 1200/1400mm sweep any type any make including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins (02 Nos), cutter pins(02 Nos), and refixing to the same location after servicing Complete all as specified and directed by Engineer-In-Charge.
Supply and Fixing in replacement of PVC cable insulated and overall sheathed with flexible copper conductor of size 0.5 sqmm, 3 core cut to size of approx 0.30 metre from fan to ceiling rose Complete all as specified and directed by Engineer-In-Charge.
M&L for taking down old unsv exhaust fan from site and removal of burnt winding by cutting, clening slots and re-winding of exhaust fan/ Table fan/cabin fan of motor capacity 250-380mm sweep any make with super enameled copper winding wire of exisiting gauge, including cuting and getting out old burnt winding, sleev work , varnish with E class insulation varnish threading, including neceassry laith , granding and welding work complete and connections with appropriate size copper conductor cable upto connector block Complete all as specified and directed by Engineer-In-Charge. (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used)(ii) Motor shall be wound with machine only. (iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used. (iv) Copper winding shall be of weight upto 300 gms.
All as per Srl item No 66 here-in-above but for exhaust fan/ Table fan/cabin fan of motor capacity 400mm-450mm sweep Complete all as specified and directed by Engineer-In-Charge.
Material and Labour for removing old paint by scraping down with sand paper including washing and filling cavaties with filler and applying two coats of painting with synthetic enamel paint over a coat of red oxide primer by spray gun using spray gun method painting to ceiling fan of 1200mm sweep at site including 03 Nos blades, motor (both sides) down rod, writing MES No/ Srl No on the ceiling fans Complete all as specified and directed by Engineer-In-Charge.
All as per Srl item No 68 here-in-above but for ceiling fan of 1400mm sweep Complete all as specified and directed by Engineer-In-Charge.
All as per Srl item No 68 here-in-above but for Exhaust fan of 400mm sweep Complete all as specified and directed by Engineer-In-Charge.
All as per Srl item No 68 here-in-above but for Exhaust fan of 300mm sweep Complete all as specified and directed by Engineer-In-Charge.
Sreekrupa Enterprises
T.P.SUNIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .