Loading…
Loading…
Tender Value
₹4.3 Cr
EMD Value
₹3.7 L
Closing Date
2 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
W5
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Part I of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following c ategories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or(ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or(iii) One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar work means :-"Any Signaling work involving Outdoor work and addition and/or alteration in existing Indoor signaling system. OR Any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving and Outdoor. Similar work to include Indoor if the tendered work involves addition and/or alteration in existing Indoor signaling system and Outdoor if the tendered work involves Outdoor work OR Any such work involving activities as given in the name of the tendered work.)."
Note:- After issue of LOA and before signing of Contract Agreement, successful bidder shall submit an undertaking/MoU from RDSO approved EI OEM to confirm compliance with extant RDSO guidelines and to meet contract specific requirements.
15 conditions · 4 needing a document upload
As per "CHECK LIST" document attached.
Following documents dully filled & signed to be uploaded. Standard formats are provided in (Annexure provided with tender document. Tenders are required for furnish details in thhese format).
"Tender Form" As per 'TENDER FORM" (Ref Standard format provided in Annexures).
Deviation Statement:- The tender shall submit a statement indicating any deviations against any clause of this tender including all the technical specication concerned to this work, duly signed and stamped on each page. If there are no deviation whatsoever, a Nil deviation statement should be submitted. (Ref Standard format provided in Annexures) In case firm has not submitted deviation or blank deviation statement it will be treated as NIL deviation.
List of works completed: list of works completed in the last seven financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of schedule completion of work. Date of actual start, actual completion and final value of contract should also be given. (Ref Standard format provided in Annexures).
List of works on hand:- List of works on hand indicating description of work, contract value, and approximate value of balance, work yet to be done and date of award (Ref Standard format provided in Annexures).
Details of payment through NEFT/RTGS. (Ref Standard format provided in Annexures).
List of Personnel, organization:- List of Personnel, organization/technical staff available on hand and proposed to be engaged for the subject work, with their designation and experience.
Document for technical skill:- Documentary evidence necessary to establish that they possess the requisite skill, technical expertise, technical and skilled manpower and necessary equipment's to execute complete work covered in the schedule with stipulated specification/details.
Special instruction regarding payment of Bid Security: Excerpt of GCC April -2022 read as (i)Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security. (ii)Labour Cooperative Societies shall deposit only 50% of above Bid Security. (Refer para 7.0 of CHAPTER-II {INSTRUCTIONS TO TENDERERS} of Tender document) for clarification see GCC April-2022. Mandatory submission of relvent document if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Alteration/Modification of Existing Electronic Interlocking and Associated Supply, Installation, Testing & Commissioning of Signalling Materials in connection with Operationally Required Modifications in Existing Sanand and Chharodi Station Yards of Ahmedabad Division.
DRM-SnT-ADI-Sig23of25-26
DRM-SnT-ADI-Sig23of25-26
Open
Works - General
12 Months
Ahmadabad, Gujarat
₹0
₹3.7 L
2 Mar 2026
2 Feb 2026
16 Feb 2026
154 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 57,27,062.43 | ||
| — | 2.00 | — | — | ||
| Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | — | — | — | 48,016.24 | |
| — | 8.00 | — | — | ||
| Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable). | — | — | — | 44,904.8 | |
| — | 20.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 1,11,520.8 | |
| — | 12.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23. | — | — | — | 88,685.28 | |
| — | 6.00 | — | — | ||
| Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78. | — | — | — | 44,362.08 | |
| — | 2.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | — | — | — | 19,487.94 | |
| — | 10.00 | — | — | ||
| Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F- 1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60. | — | — | — | 48,789 | |
| — | 10.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60-78. | — | — | — | 54,214 | |
| — | 2.00 | — | — | ||
| Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments. | — | — | — | 6,708.16 | |
| — | 1000.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Disconnect Terminal Block, Screw less type, 4- wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 58,530 | |
| — | 60.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 664.2 | |
| — | 120.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 1,303.2 | |
| — | 10.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 1,138.8 | |
| — | 30.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 1,529.7 | |
| — | 40.00 | — | — | ||
| D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest Quantity break up of each type of fuse block will be specified by Engineer in-charge. | — | — | — | 1,277.2 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 59,487.26 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 1,03,907.56 | |
| — | 25.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 14,96,399.5 | |
| — | 18.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 9,35,965.08 | |
| — | 6000.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 4,50,000 | |
| — | 30.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 57,366 | |
| — | 360.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 4,21,300.8 | |
| — | 90.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 2,51,909.1 | |
| — | 10.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 35,232.7 | |
| — | 10.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 9,784.6 | |
| — | 40.00 | — | — | ||
| Provision of Field accessories of DC Track Circuits Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks. | — | — | — | 44,826 | |
| — | 20.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments. | — | — | — | 42,590.6 | |
| — | 4.00 | — | — | ||
| Supply Color Light Signal Accessories. 1. CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M With latest assembly). 2. Pinnacle. 3. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. 4. Signal Front Staging Complete Assembly for CLS Unit. 5. Signal back staging as per extent WR Practice. | — | — | — | 13,005.32 | |
| — | 4.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 1,19,295.64 | |
| — | 4.00 | — | — | ||
| Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | — | — | — | 18,120.28 | |
| — | 10.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 55,485.4 | |
| — | 4.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 1,33,464.84 | |
| — | 5.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 6,80,317.75 | |
| — | 2.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 2,65,010.24 | |
| — | 4.00 | — | — | ||
| Supply Color Light Signal Accessories. Supply of signal no plate as per Drg no CSTE Drg No CSTE/6186. | — | — | — | 2,462.36 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2RevisedTNo23of2025-26.pdf
ATTACHMENT
3TNo23of2025-26Annexure.pdf
ATTACHMENT
CHHARODI SIP
ATTACHMENT
SANAND SIP
ATTACHMENT
4CHHARODISIPEXTENDEDLINETENDERPURPOSE-Model.pdf
ATTACHMENT
4SANANDSIPPRODENDLINENO5TENDERPURPOSE-Model.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .