Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | Admitted-Finance |
| 2 | Admitted-Finance 2 SHANTI NAGAR SECTOR 3 HIRAN MARGI UDAIPUR 313002 | UDAIPUR | UDAIPUR | RAJASTHAN | 313002 | Admitted-Finance |
| 3 | Admitted-Finance SHIV SHAKTI NAGAR PLOT NO 35 NIWARU ROAD JHOTWARA JAIPUR 302012 | JAIPUR | RAJASTHAN | 302012 | Admitted-Finance |
Tender Value
₹4.2 L
EMD Value
₹8,428
Closing Date
15 Feb 2020, 6:00 pmClosed
Sr. Manager Engg.(E)
O/o Airport Director, AAI, Civil Airport Jodhpur
Unforeseen Electrical works at CA Jodhpur Sub Head-Servicing, Testing and Calibration of ACBs, Relays and Allied work at Civil Airport Jodhpur
2020_AAI_42292_1
AAI/ ENGG (E)/JOD/WE-113/2019-20
Open Tender
Electrical Works
Works
45 days
Jodhpur
As per NIT
10 documents required · 10 mandatory
₹1,120
Airports Authority of India
₹8,428
27 Mar 2020
7 Feb 2020
21 Feb 2020
8 Feb 2020
15 Feb 2020
8 Feb 2020
8 Feb 2020 - 14 Feb 2020
Amount
Servicing of 4P, 415V, 800A-1600A motorised/ manual charged Air Circuit Breakers (C&S Make, Model No. AH-8D-CS & AH-16D-CS) including checking breaker operations, control wirings and fault rectification etc along with lubrication of moveable parts, cleaning of jaw contacts, sparking chambers etc., and replacement of defective parts (if any) and submission of test/service reports etc. complete as required as per site conditions (defective spare part would be provided by AAI)
Servicing of 4P, 415V, 800A-1000A motorised/ manual charged Air Circuit Breakers (GE Make, Model No. Spectronic S800 & SpectronicS1000) including checking breaker operations, control wirings and fault rectification etc along with lubrication of moveable parts, cleaning of jaw contacts, sparking chambers etc, and replacement of defective parts (if any) and submission of test/service reports etc. complete as required as per site conditions (defective spare part would be provided by AAI)
Testing and Calibration of Voltage and Current Operated HT Relays (for 11kV VCB) and LT Relays (for ACBs) (Make:- GE Power, C&S & Easun Reyolle) including secondary injection testing and settings as per OEM's recommendations, submitting test reports etc. complete as required. The work shall be carried out from experienced relay calibration agency. (Defective spare part would be provided by AAI)
Visiting charges by highly skilled personnel having experience of control wiring, well versed with control wiring drawing for identification & rectification of fault in AMF Panel of 500 KVA DG set / interlocking mechanism of HT/LT Ckt. Breakers, relays / transformer faults or any kind of fault in E&M installations at 11 kV substation as required.
Supply of following Spares (as and when required basis) suitable for 800A- 1600A, 4P, 415V, Air Circuit Breakers (C & S Make, Model No. AH-8D-CS & AH-16D-CS) etc. complete as required.
(a) Complete Mechanism (Without Side Plate & Conductor Assy)
(b) Closing Coil
(c) Shunt Trip Coil
(d) Arcing Contacts (Set of 1 No. Fixed & 1 No. Moving)
(e) Anti Pumping Relay
(f) Arc Chutes
(g) Compact UVT Coil
Supply of following Spares (as and when required basis) sutiable for 800A-1000A, 4P, 415V, Air Circuit Breakers (GE Make, Model No. Spectronic S800 & Spectronic S1000) etc. complete as required.
(a) Complete Mechanism (Without Side Plate & Conductor Assy)
(b) Closing Coil
(c) Shunt Trip Coil
(d) Arcing Contacts (Set of 1 No. Fixed & 1 No. Moving)
(e) Arc Chutes
(f) Compact UVT Coil
Preparation, Providing and fixing of complete single line diagram of E&M installation of 11KV substation (i.e. HT/LT panels, Transformer, DG AMF panels, Solar plant etc.) to be printed on vinyl sticker (Size 3 ft. x 5 ft.) and pasted on 3mm Acrylic panel sheet including site visit, submission of single line diagram for prior approval by E-I-C and submission of 3 sets on A2 paper, one CD of final complete single line diagram in Auto CAD etc. complete as required as per site conditions.
Servicing and testing of 11 kV, 630 A, Vacuum Circuit Breaker (VCB) as per OEM's recommendations including checking breaker operations, control wirings and fault rectification etc along with lubrication of moveable parts, cleaning of jaw contacts, sparking chambers etc., and replacement of defective parts (if any) and submission of test/service reports etc. complete as required as per site conditions (defective spare part would be provided by AAI) (Make : AREVA Modal VMX-606)
MPC ELECTRICALS AND ENGINEERS
Navyug Engineering
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .