Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹11.3 L+₹19,710 (1.77%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹11.6 L+₹50,803 (4.56%)Rejected-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L3 | Rejected-Finance Rejected | |
| 4 | L4₹12.0 L+₹87,595 (7.86%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | Rejected-Technical H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | - | Rejected-Technical Non- Responsive |
Tender Value
₹10.5 L
EMD Value
₹21,100
Closing Date
15 Jan 2020, 11:00 amClosed
Executive Engineer
HP CITY Tpt. and BSM and DA Tutikandi Shimla 4
SH Providing Electrical Installation therein
2019_BSMDA_33611_4
HPBSMDA/EE/(2)/2018 TENDERS (VOL-II)
Open Tender
Civil Works - Buildings
Item Rate
365 days
Shahpur
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
CEO HP CT BSMDA
₹21,100
6 Mar 2021
24 Dec 2019
15 Jan 2020
28 Dec 2019
15 Jan 2020
28 Dec 2019
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface /recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. 2x1.5 Sq. mm
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS /PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS /PVC insulated single core copper conductor cable of same size for earthing as required. 2x6.0 Sq. mm.
2x10 Sq. mm.
2x16Sq. mm.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and fixing of fancy wall bracket containing thread type LED lamp holder (s) of all sizes and shapes, complete with all accessories but excluding LED lamp including making connections, testing etc. as required. Fixed type wall bracket 150 dia, single lamp.(Category-A)
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-4 way
Double door-8 way
Double door-6 way
Double door-2 way
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole. Cat-A.
Double pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps. Cat-A.
63 Amps. Cat-A.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required :-Ceiling Fan 1200 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Supplying and laying 8 SWG Copper wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc. as required.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Armoured cable 50 sq. mm (3.5 core)
Armoured cable 6 sq. mm (twin core)
Armoured cable 25 sq. mm (twin core)
S/F Led Surface downlight square/round of syska or its equivalent approved make of following wattage complete with connections etc as required capable in all respects. Led surface Downlight 12 watt (1'x1')
Led surface Downlight 22 watt (1'x1')
Led surface Downlight 36 watt (2'x2')
S/F LED Tubelight 20 Watt in Aluminium housing of syska or its equivalent approved make of complete with connections etc as required capable in all respects.
S/F Led Bulk head 9 watt (6500k) of syska or its equivalent approved make of complete with connections etc as required capable in all respects.
S/F Led street light 45 watt in extended aluminum housing slim design of syska or its equivalent approved make of complete with connections etc as required capable in all respects.
Supplying Installation testing & commisioning of Energy meter box complete with 4 pole MCCB 100 amp,Coopper busbar 100 amp,metering with Amperemeter,voltmeter.Indication & space for housing 10 no,single phase energy meter as required capable in all respects.
Supplying Installation testing & commisioning of 4 pole MCCB 200 amp,/megnetoththermal release 50 KA of C& S make with enclosures Complete in all respects.
Supplying and erection of 3 stepped steel tubular swaged and welded pole of suitable length and dia. to be fixed up to a required planting depth below G/L in a hole of excavation about 30 cm dia. and of suitable depth, to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mmx100 mmx 45 mm deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB, the outer surface of the plinth to be finished with 1:3 cement plaster 6 mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coat complete in all respects as required:- (b). Overall length 8 meter, with planting depth 1.5 m, length of sections 4.5 m, 1.75m and 1.75m (bottom, middle and top respectively), outer dia and thickness of sections 127mmx4.5mm, 101.6mmx3.65mm and 76.1mmx3.25mm (bottom, middle and top respectively) with approximate weight 84 Kg.
Supplying and fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx4.75mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx450mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and erection of street light bracket made of G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:- 40 mm dia. G.I. pipe, heavy class
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
Supplying and fixing of MCCB 80 amp to 100 amp. 3 Pole 415 volt with enclosure complete in all respect.
raman devwedi
GURU NANAK ELECTRICALS
Mahesh Chand
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .