Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.9 L+₹3.8 L (13.0%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L2 | Rejected-Finance Other than
lowest
tenderer | |
| 3 | L3₹33.2 L+₹4.2 L (14.3%)Rejected-Finance IV 356 RAMANTHALI PAYYANUR KANNUR DIST KERALA 670308 | PAYYANUR | KANNUR | KERALA | 670308 | L3 | Rejected-Finance Other than
lowest
tenderer | |
| 4 | L4₹34.6 L+₹5.5 L (18.9%)Rejected-Finance | L4 | Rejected-Finance Other than
lowest
tenderer | |
| 5 | L5₹35.0 L+₹5.9 L (20.3%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L5 | Rejected-Finance Other than
lowest
tenderer |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Aug 2022, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_537369_1
GE MAINT EZHIMALA 8492
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹80,000
Yes
22 Sept 2022
12 Jul 2022
10 Aug 2022
12 Jul 2022
8 Aug 2022
26 Jul 2022
13 Jul 2022 - 20 Jul 2022
Amount
Notes:- 1. Contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safety measurers adopted by contractor on site for working at any height / any building/any size of poles of INA Ezhimala. 3. The contractor shall also provide one electrician & one helper on every working days and also provide on sunday / holiday if required or asked by JE E/M / Engineer-in-charge. 4. Contractor will be responsible to collect complaints from MES Complaint Cell Ezhimala at 9.00 am (every working day) and after resolving the complaint, resubmit at MES Complaint cell for entry in computer. 5. The contractor should arrange their own vehicles with ladders for repairing of street light fittings. 6. If contractor failed to provide their electrician and helper or absent to attend the complaints then recovery will be done Rs 1500.00 Per day. For Ser item No 35:- 7. The foundation work will be executed as per detailed drawing attached with PS.
Taking down the unserviceable LT UG cable of size upto 16 sqmm including removing electrical connection and keeping side serviceable cable including removing cable protection cover etc complete all as specified and as directed by Engineer in charge.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed. Notes:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and as directed.
Supply and spreading riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and directed by Engineer in charge. Note:- Punned thickness shall be measured for payment purpose.
Supply and lay PCC un reinforced cable cover of size 250 mm x 150mm x 40mm, class LV type I flat for cable protection complete all as specified and as directed.
Relaying of PCC un reinforced LT cable cover of size 250 mm x 150mm x 40mm obtained from ser item no 1 complete all as specified and directed by Engr in charge.
Relaying of cable XLPE insulated heavy duty galvanised steel strip armoured LT 1100 volt grade with aluminium conductors multistranded confirming to IS laid in trenches/pipes/wall size upto 16 sqmm 4/3.5 core obtained from ser item no 1 complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 16 sqmm 4 core complete all as specified and directed by Engineer in charge.
All as per item no.10 above but size of 25 sqmm 3.5 core complete all as specified and directed by Engineer in charge.
All as per item no.10 above but size of 10 sqmm 4 core complete all as specified and directed by Engineer in charge.
M&L for dismantling/removal existing pole of post top lantern of any type from it's position/foundation after necessary exavation and earth work and refixing on other site with all required materials complete all as specified and directed by Engineer in charge.
Material and labour for mass filling in foundation/coping/wall with PCC 1:3:6 using 40 mm graded aggregate type C2 as per site requirement complete all as specified and directed by Engr in charge.
Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 Mtr and depth 0.7 Mtr all as directed and making good the road/hard using pre mix bituminous as required at site to match with the existing surface complete all as specified and as directed. Note:- Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge.
Supply and fix in replacement of GI tubing light grade 40 mm nominal dia in trench/road/pole for cable protection complete all as specified and as directed.
Supply and fix in replacement of GI tubing light grade 50 mm nominal dia in trench/road/pole for cable protection complete all as specified and as directed.
Supply and fix in replacement of copper cable flexible 2.5 Sqmm 3 core 230 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of decorative post top lantern 40 Watts for 360 degree indirect light with IP 65 protection ,resistant to impact and corrosion, out put lumens per watt is greater than 100 lumens complete all as specified and as diected by Engr in charge. Make:- Model No. LPTO-40-CDL of make Crompton or equivalent in Philips/ wipro /havells/bajaj.
Supply and fix in replacement of bollard light fitting twister type robust design LED light 10W ,IP 65 protection complete all as specified and as directed by Engr in charge. Make:- Model No. LBLTW-10-WW of Make Crompton or equivalent in Philips/wipro /havells/bajaj.
Supply and fix in replacement of old unserviceable street light fitting with LED street light fittings luminaire 60 watts ,240V 50Hz pressure die cast aluminium housing with toughened and heat resistant glass ,IP 66 protection, out put lumens per watt is greater than 100 lumens including 10kV surge protection device complete all as specified and as directed by Engr in charge. Make:- Model No. CRP-409-60-57-SL-GL-NSG of crompton or equivalent in Philips/wipro/havells.
All as per item No.21 above but of capacity 45 watt,out put lumens per watt is greater than 100 lumens complete all as specified and as directed by Engr in charge. Make:- Model No. CRP-409-45-57-SL-GL-NSG of crompton or equivalent in Philips /wipro/havells/bajaj.
Supply and fixing in replacement of LED flood light luminare 70 W with high pressure die cast housing,out put lumens per watt is greater than 100 lumens complete all as specified and as diected by Engr in charge. Make:- Model No. LFL-70-CDL/60-M of Crompton or equivalent in Philips/wipro/ havells/bajaj.
S&F in replacement of die cast aluminium IP 66 120W LED flood light luminaire, out put lumens per watt is greater than 100 lumens complete all as specified and as directed by Engr in charge. Make:- Model No. LFLN-120-CDL/60-M of Crompton or equivalent in Philips/ wipro /havells/bajaj.
Supply and fix in replacement of weather proof street light junction boxes made out of thermo plastic consisting of 4 nos of connectors of capacity 40 amp 415v and 1no of SP MCB rating 6 AMP 240 V with proper closing arrangement, elmax connector for neutral link including pole mounting clamp with nut bolts etc, the size of the box shall be minimum of size 205mmx255mm112 mm, the box should have two cable entry complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED bulb B22 type 09 Watts in garden lights/ dome lights after removing the outer cover and refixing the same after replacement complete all as specified and directed by Engineer-in-Charge.
Taking down the defective security light fittings/street light fittings of any type from 11/10/8.5 mtr swan neck type pole and refixing in same position after carrying out necessary minor repair work and cleaning the fittings, reconnecting the joints, replacing drivers complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of bracket made out of GI pipe medium grade, 50 mm dia, 90 cm long for fixing street light with and including clamps, nuts, bolts, washers etc complete accessories and applying two coats of oil painting over one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6 mm buried in the ground to a depth not less than 2.25 mtr below ground level connected to GI 4 mm wire by means of GI nut, bolts, washers and check nut and complete as shown in electric plate No 03 of SSR Part-I connected to earthing test point including 20 mm dia GI pipe medium grade for watering, funnel and PCC pit cover with RCC cover of size 30cm x 30cm including earth work for excavation and removal of surplus soil complete all as specified and as directed.
Supply and fix in replacement of old unserviceable high mast light fitting accessories (Top head with accessories, Lantern carriage, Lantern carries stand, Rope guide, Lighting arrestor, double drum winches set, Nuts, Bolts, washers, Copper wire 4 core 4sqmm, Stainless steel wire Rope 6 sqmm,3 phase motor,U clips, 5 core wire 2.5 sqmm ,Trailing cable, control pannel with timer with stand, distribution box, winch stand,Junction Box, Aviation light etc) fix on high mast pole, repairing of mast door and locking arrangement, testing after fixing all accessories complete all as specified and directed by Engr-in-Charge. Note:- (a) Light fittings shall be measured and paid separately. (b) Replacement of pole not included in above item.
M&L for replacement of aesthetically appealing landscape cum street light, made from aluminium housing, IP 65 rated of capacity 40 watt complete all as specified and directed by Engr-in-Charge. Make:- Cat Pat No SZPSCPD040 of Shakti make or equivalent in Havells/Philips/ Bajaj/Jaguar.
Supply and fix in replacement of single LED aviation light with polycarbonate diffuser & cast aluminium housing with IP 65 rated including all required items for fixing of light complete all as specified and directed by Engr-in-Charge. Make:- Cat Pat No SZPALMX-1 of Shakti make or equivalent in Havells/Philips/ Bajaj/Jaguar.
Supply and fix in replacement of single LED street light with smart sensor of 60 watt capacity with IP 65 Rated including all required items for fixing of light complete all as specified and directed by Engr-in-Charge. Make:- Cat Pat No SZPSLPM060-DPSD of Shakti make or equivalent in Havells/ Philips/ Bajaj/Jaguar. Note:- Sensor should able to detect motion from minimum 10 mtr height with preset 50% light output when motion not detected & 100% ight output when motion detected.
M&L for construction of RCC foundation for high mast lights with RCC M-30 (Design Mix) using Mild steel TMT bars including necessary use and waste of form work, earth work excavation in hard/dense soil, returning filling in, removing surplus excavated material, PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and directed by Engr-in-Charge and shown in drawings. Note:- (a) Taking down highmast light fittings and refixing at other locations will be as per direction of Engr-in-charge. (b) Suitable size of nuts,bolts,plates etc all as per direction of Engr-in-charge.
Gates Infra Construction Co
M/S V ASSOCIATES
TAMS ASSOCIATES
JEETH CONSTRUCTION
Benchmark Engineers and Contractors
LUCKY ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .