| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC D NO 71 31 950 CHINTALALOVA GANDHIGRAM POST VISAKHAPATNAM 530005 | VISAKHAPATANAM | ANDHRA PRADESH | 530005 | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹28.9 L+₹2.5 L (9.50%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.1 L+₹6.7 L (25.4%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹33.9 L+₹7.5 L (28.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹34.1 L+₹7.7 L (29.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIRS/ REPLACEMENT TO SEWAGE LINE, MAN HOLES AND CLEANING OF SEPTIC TANK, MH, SWT, SEWAGE LINE AND REPAIRS TO HARDSTANDING , PCC PAVEMENT, PATH AND CULVERT AT TECHNICAL AND NON TECHNICAL AREA AT INS KALINGA AND KARNA UNDER GE (P) NAVY KALINGA VISAK
2023_MES_597303_1
GE (P)/N/K/8028/23-24 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a(ii)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹85,000
Yes
10 Jul 2023
22 May 2023
21 Jun 2023
22 May 2023
19 Jun 2023
5 Jun 2023
Amount
Taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/ manholes/Soak well by mechanically means incl cleaning the septic tank/ man hole with water and spreading bleaching powder @ 200 gms per sqm for disinfections purpose and making the system functional complete all as specified and as directed. Depth of manhole/Soak well/ Septic tank depth exc 0.50m to 1.50M from below GL. Notes : (i) Quantity upto water/ Sludge level shall be measured. (ii) The Solid/ Semi solid/ Liquid waste obtained to disposed off outside the Defence land. (iii) No extra payment shall be made for dewatering and cleaning with water which shall deemed to be included in the unit rate of this item. (iv) Bleaching powder measured and paid separately. (v) Septic tank/ manhole sludge removal to be carried out phase wise manner periodically and on requirement basis.
All as item No 01 above but depth 1.50m to 4.00m.
Supply only Bleaching powder.
Cleaning the Sewage pipes of size 100mm internal dia of any type by rodding or green bamboo and removing the sludge/ effluent along with any foreign materials and flushing the sewage line with water to make sure the line should be clear in all aspects including taking off and replacing manhole cover the same should be ensure between manhole to manhole complete all as specified and as directed.
All as item No 04 above but 150 mm bore
All as item No 04 above but 200 mm bore
Cleaning of blocked / chocked WC (any pattern) including cleaning upto first manhole of sewer/ sewage line of any type of dia 100mm/ 150mm/ 200mm dia by rodding or hand pumping and well flushing the completed sewer line with water to the entire satisfaction of user concern complete all as specified and as directed.
Cleaning of blocked / chocked Nahani Trap/ floor trap/ Gully trap in bathroom or kitchen or cook house including cleaning upto first manhole sewage lines of any type of any size by rodding or hand pumping and well flushing the completed sewer line with water to the entire satisfaction of user concern complete all as specified and as directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
All as per item No. 09 here in before but depth exc 1.50m and n.exc 3.00m deep.
Returning filling in including spreading, levelling, watering and well ramming in layers n exc. 25cm in soft/loose soil complete all as specified and directed.
Demolition of and breaking up Cement concrete bed including hauching and taking out any type of pipes set in cement mortar for 100mm dia pipes complete all as specified and directed
All as per item No. 12 here in before but 150mm dia pipe.
All as per item No. 12 here in before but 200mm dia pipe.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in bed to drain pipe 100mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed.
All as per item 15 above but for 150mm bore complete all as specified and directed.
All as per item 15 above but for 200mm bore complete all as specified and directed.
M&L for 100mm bore HDPE DWC pipes, class SN8, laid in trenches and jointed using rubber ring joint method complete all as specified and directed. Note :- i) New pipe shall be laid/ Placed on same day as and when old pipes taken out to maintain workable condition.
All as per item 18 above but for 150mm bore complete all as specified and directed.
All as per item 18 above but for 200mm bore complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry as per IS 2185, grade C5 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in CM 1:6
M & L for Fly Ash block masonry (Modular size) solid blocks, exc. 10cm in width with class designation 75 (Kgf/cm2) in half brick walls and setting in CM 1:4 complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M & L for providing PCC 1:3:6 type C2 using (40mm graded stone aggregate) in foundation filling and mass concrete.
M&L for precast RCC 1:1.5:3 type A1 using 20mm stone aggregate as in cover slabs, for manholes etc and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed.
M&L for TMT bars, 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified.
M&L for PCC (1:3:6) type C-2 (using 40mm graded aggregate) as in surface channel and drain finished even and smooth using extra cement complete all specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded aggregate) as in copings and haunchings of Manholes, finished even and smooth using extra cement complete all specified and as directed
M & L for Brushing neat finish slurry with 3.0Kg of cement per Sqm complete all as specified and as directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, incl forms etc complete all as specified and directed.
Taking down cement or cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:4 on brick work or concrete surfaces including finished even and fair complete all as specified and directed.
Supply only integral water proofing liquid admixture for plaster.
M & L for 90mm thick M-40 Grade Heavy duty SFRC (Steel Fibre Reinforced Concrete) factory made manhole cover with 1.30mm thick MS Sheet at edges and frame, Both cover and frame of Size square or rectangular or round shape with 2 Nos lifting hooks flushed with cover slab including cutting existing brick or concrete wall of thickness upto 100mm and fixing SFRC frame in PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate complete all as specified and as directed. Note :- 1. Rate including Frame & PCC 1:2:4.
S & F in Repairs to PVC Nahani trap including jointing to waste pipe, fixed in cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate, dia of outlet 100mm complete all as specified and as directed.
S & F in repairs to 100mm Diameter Stainless steel anti cockroach floor trap with SS grating including jointing to nahani trap, fixed in cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate complete all as specified and as directed.
M&L loose filling with broken bricks of gauge 80 to 150mm in soakage pits / soakage wells complete all as specified and directed.
Use & waste of form work to soffits of man hole cover not. exc 200mm thick, and flat fair finished surfaces complete all as specified and directed.
Dismantling of cast iron or PVC pipes of 110/100/75 mm dia jointed in cement mortar and taking out from trenches/ wall , if required complete all as directed
S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed.
All as per item No 42 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed walls complete all as specified and directed.
All as per item No 44 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius with access door complete all as specified and directed.
All as per item No 46 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110m bore junction double, (Single T) equal or unequal complete all as specified and directed.
All as per item No 48 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110m bore junction double, (Double T) equal or unequal complete all as specified and directed.
All as per item No 50 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed.
All as per item No 52 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement complete all as specified and directed.
M & L for Cutting Bituminous/ Concrete Roads for laying pipelines / sewage lines of width upto 1.0m and depth upto 0.5m and making good with 100mm thick PCC 1:2:4 type B-1 (using 20mm course aggregate over 100mm-300mm thick hardcore of 40mm-63mm size boulders over 100mm thick sand complete all as specified and as directed.
Dismantling old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M & L for non skid, ceramic “coloured” joint free tiles of size area of each tile exceeding 0.06 sqm but not exceeding 0.11 and thickness 7-8mm, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over 15mm thick screed bed of CM 1:6 complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 300 x 450 x 7mm thick as in vertical surfaces set & jointed in neat cement slurry & pointed with coloured cement to match over 10 mm thick rendering with CM 1:4 all as specified and directed.
S & F in repairs vitreous china white squatting pan "Orissa Pattern" size 580x440mm, with integrated foot rest (excluding flushing cistern, flush pipe etc) including making good to floor complete, all as specified and directed.
S & F in repairs to Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/ off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) including making good to floor complete, all as specified and directed.
S&F in repair 10 litre capacity PVC valve less syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including flush bend pipe and brackets complete all as specified and directed .
S&F in repair to PVC flexible waste pipe 32mm dia 1.0m length including clamp and screws complete all as specified and directed.
S&F in repair to PVC flexible waste pipe 40mm dia 1.0m length including clamp and screws complete all as specified and directed.
S & F PVC flexible connections 15mm size with PTMT nuts of length 600mm
S&F Mild steel bars, 10 mm dia and over cut to length, bent to shape required as in Rungs of Manholes embedded in Concrete and fixed with support complete all as specified and as directed.
Uprooting of wild trees such as grasses/ bushes etc. from the Man holes/soil pipes/ Septic tanks/ Soak wells surroundings including its penetrated roots and making good to the damaged plaster by providing cement mortar (1:3) and finished the surfaces to match with existing surfaces complete all as specified and as directed. (Cost of materials is deemed to be included within the quoted rate)
S & F in repairs of MS Sheet with hooks, MS angle frame work, Gratings by welding conforming to Fe-290 Gde-165 completed all as specified and as directed.
M & L for Making good Masonry walls/ RCC walls during replacement of Pipe lines on vertical wall surfaces of any height by filling with Cement mortar (1:3) over PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate and finished the surfaces to match with existing surfaces by painting complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm below or above ground level including removal of demolished materials from work site complete all as specified and as directed.
Demolition of reinforced cement concrete in roof, floor (other than ground floor) beams, staircase, chajja and similar suspended works (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness complete all as specified and as directed
M & L hardcore of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface, complete all as specified and directed.
M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc complete all as specified and as directed.
M&L Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed
M & L 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floor and finishing he surface of concrete by brooming complete all as specified and as directed.
M & L 50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floor complete all as specified and as directed.
M & L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base/ floor, complete all as specified and directed.
M&L for Forming 20mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ in 100 mm thick concrete
M&L for forming contraction (dummy) joints 65mm deep x 10mm wide, grade 'A' filled with sealing compound complete all as specified and as directed.
M & L designer chequered cement concrete tiles rubber moulded 20 cm x 20cm x 25 cm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed or bedding layer of CM (1:4) complete all as specified and as directed
M&L for Brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed
M&L sand filling under floor or in foundations including watering and consolidation complete all as specified and directed.
S&F machine pressed precast concrete interlocking paver blocks of approved shape and size confirming to IS 15658-2006 of 80mm thickness and M-40 grade, with grey cement and pigments complete all as specified and as directed.
Excavation over areas exe 1.5 mtr but n.exc 3.0 mtr deep and getting out in soft/ loose soil complete all as specified and as directed.
Removing excavated material from site to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for Reinforced Cement Concrete,1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in foundations, including rafts, footings, plinth beams etc and the like complete all as specified and directed.
M&L for Reinforced Cement Concrete,1:1.5:3, type A1 (using 20mm graded granite stone aggregate) as in walls, retaining walls, basement walls etc and the like complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sided and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surface of concrete completed all as specified and as directed.
Use and waste of form work to faces of walls rough finished surfaces of concrete complete all as specified and as directed.
M&L for Reinforced concrete pipes, of 600 mm bore class NP3, laid and jointed complete with collars complete all as specified and as directed.
S&F 50 mm dia high density polyethylene (HDPE) pipe of pressure rating 6 kgf/ sq. cm
M & L for rendering 10mm thick in CM 1:4 on brick work or concrete surfaces including finished even and fair complete all as specified and directed.
M & L for preparation of new external surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for Stone kerb of granite or trap stone of roughly squared stones of size 20cm x 30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush complete all as specified and directed.
SRK PROFESSIONAL ENGINEERING
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
SSV CONSTRUCTIONS
SREE VIGNESWARA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .