Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance BHALLA FARM NO 8 SHYAMUR RISHIKESH DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
30 Jul 2025, 2:30 pmClosed
EE, PD, PWD, Haridwar
EE, PD, PWD, Haridwar
Waterproofing work in the State Guest House Atal Bihari Vajpayee of the Department of State Property in Distt. Haridwar under Deposit Scheme.
2025_pwd_85478_1
1969/2A Dated 27.06.2025
Open Tender
Civil Works - Buildings
Item Rate
120 days
Haridwar
Please refer Tender documents.
1 document required · 1 mandatory
₹3,540
Yes
EE, PD, PWD, Haridwar
₹86,000
30 Jul 2025
17 Jul 2025
30 Jul 2025
17 Jul 2025
30 Jul 2025
24 Jul 2025
Amount
Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & oneycombed surface of RCC underground structures like basement water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 22.25.1 For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running meter per metre.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing and applying 2 coats of solvent based PU over the primer one coat horizontally and second coat vertically.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (For the purpose of measurement the entire treated surface will be measured.)
Providing and applying1.2mm thick EPDM (Ethyle Pethyle Desmodor Monomer) water proofing membrane along with surface preparation by mechanical grinder over constuction joints/expansion joints along with applying 1st coat of primer followed by one coat of adhesive for EPDM on the surface and rubber membrane i/c supply of all material labour T&P etc,also i/c treatment to expansion/construction joints.
Providing goia 75x75 mm in cement concrete 1:2.4 {l cement: 2 coarse sand :4 stone aggregate 10 mm and downgauge), including finishing with cenrent mortar 1:3 (l cement 3 fine sand) as per stanciard design : ln 75x75mm deep chase.
TREATMENT TO ALEX AND C.G.I SHEET BY H DPE SELF ADIIESIVE SH EET TO C.G.I SHEET a. Cleaning the existing surface wrth wire brush. b. Providing and fixing 1.2N/tvl HDPE self adhesive sheet over the C.G.l and Alex.
TREATMENTTOJOINT BY PU SEALANT Treatment to cracks by using polyurethane baseC single component permanently elastic joint sealent of Groove size (7.5mm x 12.5mm) including cost of all material labour T&P etc
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 0 mm gap for thermal expansion.Coupler 1 1 0 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 0 mm gap for thermal expansion.Bend 87.5° 1 1 0 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm nominal dia Pipes
Providing and fixing PPR Unions.PPR Union 25 mm
Providing and fixing PPR Unions.PPR Union 40 mm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
jmd constructions (BID ID -391641)
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .