| 3 | L3₹42.0 L+₹3.3 L (8.48%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹42.0 L+₹3.3 L (8.48%) | L3 | Rejected-Finance Being 3rd lowest |
| 4 | L4₹42.8 L+₹4.1 L (10.5%)Rejected-Finance H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹42.8 L+₹4.1 L (10.5%) | L4 | Rejected-Finance Being 4th lowest |
| 5 | L5₹43.8 L+₹5.0 L (13.0%)Rejected-Finance PLOT NO 4 NAYA GAON HARIPUR KANWALI P O SEEMADWAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹43.8 L+₹5.0 L (13.0%) | L5 | Rejected-Finance Being 5th lowest |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
2 Jan 2024, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
PROVN OF IRON GRILL IN BLDG NO. P-100, P-34, BROKEN GLASS COPING ON THE TOP OF WALL, INTERLOCKING TILES FOR SIDE WALK OF 32 CIVILIANS QTR, TIN SHED BEHIND BLDG NO. P-9, IRON GATE FOR 14 LEADING QTRS AT NHO, DEHRADUN
2023_MES_630907_1
GE /CLT / of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹91,000
Yes
15 Jan 2024
4 Dec 2023
10 Jan 2024
4 Dec 2023
2 Jan 2024
19 Dec 2023
Amount
S&F rolled mild steel joist, channel, angle or tee sectionsas in framing for cladding, for fixing mesh , conforming to Fe410-W (Gde E-250) complete all as specified and directed.
S&F welded steel wire fabric weight n exc 4 Kg per square metre fixed complete to steel member all as specified and directed by Engr-in-Charge.
M&L for preparing new steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L preperation of old painted steel and iron surfaces of any description not otherwise described over 10cm width of girth and applying one coat of synthetic enamel paint (any tint/shade) complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete (beam,slab and column of any description and in any position) and cutting of reinforcement wherever required not otherwise specifically provided for complete all as specified and directed.
Excavation in post hole (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in any type of soil complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 (Using 20mm graded stone agrregate ) as in foundation of posts, railing and similar work complete all as specified and directed by Engr-in-Charge.
S&F mild steel roof trusses (framed), trrussed, purlins, crane gantries, rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) quality-A.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, ridge/Valleygator & inc. any type of section etc fixed with self tapping screws as specified.
M&L rubber moulded factory made machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness , M-40 grade (ISI Marked), set, jointed and pointed in neat cement slurry in floors with grey cement & pigments including and over 50 mm thick sand cushioning for laying of inter locking tiles (paving blocks) all as specified and directed by Engineer-in-charge (Note : Design/shade of rubber moulded machine presses precast concrete Paver block shall be as approved by GE/Engr-In-Charge)
M&L for 75mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping/roof kerb including necessary form work complete all as specified.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 on fair face of brick walls or concrete surfaces finished even and smooth without using extra cement complete all as specified.
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed.
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall existing surface smooth before and after complete all as specified and directed.
S&F in repair PVC (SWR) bend 110mm dia, any radius as required and jointed with approved adhesive wall existing surface smooth before and after complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shaft, wells, cesspits, manholes etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out any type of soil complete all as specified and directed.
Surface dressing not exceeding 15 cm deep and getting out any type of soil complete all as specified and directed by Engr-in-Charge.
M&L for providing cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete ,sub base of floor complete all as specified and directed.
M&L for forming embankment incl supply of earth,spreading in layers n exc 30 cm thick watering ramming and finishing surface to required shape , size etc complete all as specified and directed (Measurement shall be taken for compacted thickness).
M&L for providing precaast cement concrete type B1 1:2:4 (20 mm graded agg)as in kerb stone and setting in cement mortar 1:6 complete all as specified and directed.
M&L for preparation of new concrete surfaces and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where at a level n exc 1.5 m above the starting point in soils complete all as specified and directed by Engr-in-Charge.
Demolition of cement cocrete any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for RCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping/Slab supported on walls including necessary form work complete all as specified
M&L Providing precast cement concrete 1:2:4 Type B-0 ( 12.50 mm graded aggregate)set in cement mortar 1:6 louvres and jallies, 25mm thick (mea sured solid), including all mould- ings but excluding frame (Pre cast frame shall be measured separately and paid for unde complete all as specified and directed
M&L broken glass coping on top of boundary walls in cement mortar 1:3 25 mm thick complete all as specified and directed. Broken glass shall be approximately 63mm gauge, firmly embedded at the rate of 10kg of glass per sqm of rendered surface, jogged edges of the glass shall be left projecting.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equivalent in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i). The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equivalent in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bars stiruups 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (Nominal Mix) (1:1.5:3) type A-1 (20mm graded aggregate) as in foundations, foundation beams, plinth beams, bases for columns etc complete all as specified and directed.
M&L for reinforced cement concrete (Nominal Mix) (1:1.5:3) type A-1 (20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, base of columns, sides and soffits (any type) of foundation or plinth beams and similar works, vertical or to batter complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
Returing, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed.
M&L 15mm thick rendering cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed.
M&L two coats of cement based paint over a coat of primer to newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) stone slab as in steps, jambs, pillars, window-cills, cooking platforms and like over and including cement screed bed 15mm thick in CM (1:6) including pointing in white cement (1:2) using marble dust to match with marble shade complete all as specified and directed.
M&L mild steel framed work such as grills, gratings etc designed with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290,Gde-E-165 including welding MS square bar/ flat iron to the existing grill at various ACCN/ floor and making good to distrubed area of brickwork and concrete surface including plastering with two coats of white wash complete all as specified and directed.
Material and labour for point wiring with 1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLS) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface,provision of CI/Pressed steel terminal switch box with plastic laminated sheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS ) as earth wire connected with main common earth dolly complete all as specified and directed for the following :- (a) One light/fan/bell/exhaust fan point controlled by one, 01-way Piano type switch 06 Amp.
All as per item No.48 above but on one 3pin 5 Amps socket out let on same board controlled by one, 01-way Piano type switch complete all specified and directed.
All as per item No.48 above but on one 3pin 5 Amps socket out let on independent board controlled by one, 01-way Piano type switch complete all specified and directed .
All as per item No.48 above but with 2.5 Sqmm PVC insulated FRLS cable for 15 Amps power point.
Supply and fixing switch piano flush type single pole, one-way 5 Amps, 240 Volts AC
Supply and fixing switch piano flush single pole, one-way 16 Amp, 240 Volts AC
Supply and fixing socket out let 5 Amps flush type all as specified.
Supply and fixing socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC all as specified.
Supply and fixing ceiling rose 3 terminal/PVC/ Polycarbonate, isolated body all as specified
Supply and fixing batton/angle holder insulated bodywith back plate including 09 Watt LED Bulb all as specified.
S& F wall mounted LED batten Box type fitting Blu colour end caps pre-wired LED fitting all as per cat part No DMLN 1 LGT 8-16 with & including LED T8 tubular lamp complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated busbar all as specified and directed.
Supply and fixing MCB SP 06 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified.
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity all as specified.
M&L sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRlsh ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade cassig caping / concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed.
M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI Wire 4 mm as earthing lead with nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed.
Sully and fixing LED flood light 100 watt, IP-65, toughned glass with single control gear complete all as specified and as directed.
Sully and fixing LED flood light 200 watt, IP-65, toughned glass with single control gear complete all as specified and as directed.
M&L for Weather proof flat twin core aluminium cable conductor of size 4 Sqmm for connection of Securiry light to OH or Pole Box all acomplete as specified and directed.
M & L for cross arms, bracings, supports,clamps and back plates fabricatedfrom structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint conplete.
M&L for Weather proof flat twin core aluminium cable conductor of size 2.5 Sqmm for connection of Securiry light to OH or Pole Box all acomplete as specified and directed.
S& F in replacement LED Decorative post top ideal to lit up light 25 W for parks garden ways and gate light complete with IP 65 protection all as specified and directed.
Supply, laid in trenches or fixed on wall pipe galvanised light grade with all fitting of size 40 mm dia complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
M/S Construction Solutions
Bedi Refrigeration Works
M/S VIJAY TRADERS
sweety pest control
ANEJA AND COMPANY
Gupta Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .