Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.5 L+₹46,593.38 (1.79%)Rejected-Finance MINISTRY OF DEFENCE MES JALPAIGURI WEST BENGAL | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹26.8 L+₹78,510.98 (3.02%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹27.1 L+₹1.1 L (4.35%)Rejected-Finance NH 31 GAIRKATA PO SAKOAJHORA DIST JALPAIGURI W B PIN 735212 | JALPAIGURI | WEST BENGAL | 735212 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹28.2 L+₹2.2 L (8.51%)Rejected-Finance NEAR KRIPAN GATE BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
11 Feb 2023, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
SPECIAL REPAIR TO BLDG NO P-12 AND PROVISION OF TRIMURTI WAR MEMORIAL AT BINNAGURI MIL STN UNDER GE (S) BINNAGURI
2022_MES_571118_2
8557/E8
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹69,000
Yes
21 Feb 2023
20 Jan 2023
13 Feb 2023
20 Jan 2023
11 Feb 2023
28 Jan 2023
Amount
M& L for Surface dressing n exc 15 cm deep for adjoining area complete all as specified and directed
Excavation in trenches n.exc 1.5 in deep and n.exc 1.5 m wide for foundation etc not exc 10 sqm on plan and getting out in soft / loose soil
Excavation in trenches exc 1.5 m but n.exc 3.0 m deep and n.exc 1.5 m wide for foundation etc not exc 10 sqm on plan and getting out in soft / loose soil
Returning filling in, incl spreading, levelling watering & well ramming in layers n.exc 25cm in soft/loose soil.
Removing excavated material (soil) n.exc 1.5 km & depositing where directed by Engr-in-charge.
M&L for Plain Cement concrete (1:4:8) type D2 (Using 40 mm graded stone agg) in foundations,filling and mass concrete complete all as specifide as directed by the Engr-in-charge.
M&L RCC (Nominal mix 1:2:4) using 20mm graded stone aggr as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M & L RCC (Nominal mix 1:2:4) Type B-1 using 20mm graded stone aggr as in Columns, pillars, piers, posts and struts complete all as specified and as directed
M & L for Formwork to Formwork to sides of rectangular /squre pillars, posts, struts, piers,columns, and stanchions for rough finished surfaces of concrete complete all as specified and as directed
M & L for Formwork to Formwork to sides of circular pillars, posts, struts, piers,columns, and stanchions for rough finished surfaces of concrete complete all as specified and as directed
M & L for formwork to sides of concrete foundations,plinth beams for rough finished surface of concrete, complete all as specified and as directed
M & L for TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or secuiring with clips equality conforming to TMT bars
All as per item no 12 here-in-before but 6 to 8 mm dia as in stirrups
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair.
M & L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms,corner shelf,Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement screed (1:4) including rounded the exposed surfaces of granite complete all as specified.
S & F of 10 mm thick Acrylic based white coloured backlite Religious symbol of size 0.450 x 0.450 m fixed to column, wall and other similar structure upto height of 10.00 mtr on RCC column incl of all necessary fitting and arragement complete all as specified and as directed.
S & F of 10 mm thick Acrylic based white coloured backlite letters "INDIAN ARMY" symbol of size (8 x 0.7 M) and fixed to column, wall and other similar structure upto height of 5.0 mtr on RCC column incl of all necessary fittings and arragement complete all as specified and as directed.
M & L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over a coat of 1 mm thick wall care putty and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm). Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10
M&L for 25 mm thick PCC (1:2:4) type B1 ( 20mm graded stone aggregate) , finished concrete surfaces even and rough to receive floor finishes.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings sheets
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F pre painted galvalume aluminium zinc coating GI Based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in eaves board fixed with selp tapping screw as specified
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy racket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
S&F 40x6 MM wind ties for roof including securing bolts,cutting tops to shape as drilling holes, notching for wire etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Demolition of stone slab and tiles of any description or thickness as in floors, apron etc laid, bedded and pointe in any mortar complete all as directed.
M & L for 18 - 20 mm thick machine cut Kota stone slab as in flooring over 15mm thick screed bed or bedding layer in CM (1:6) as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.
M & L for 18 – 20 mm thick machine cut Kota stone slab as in vertical surfaces such as risers of steps, skirting, dado etc over cement screed bed, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide including preparation of newly steel surfaces all as directed.
Taking down cement plaster on brick or concrete surfaces including raking out joints,hacking for key scrubbing down with water etc.
M&L for plastering in cement mortar (1:6), 15 mm thick on brick /surfaces of other than fair face even and smooth without using extra cement.
M&L for 15 mm thick plastering in CM (1:4) on fair faces of brick/concrete surface top layer finished even and fair without using extra cement with water proofing compound (WPC will be measured and paid separately)
Supply only Integral water proofing compound
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles
M&L brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius built in CM 1:6
M&L for preparing new plastered surfaces of wall with 2 mm wall care putty and applying two coat of distemper oil emulsion over a coat of primer complete all as specified.
M & L preparation of old surface of walls 2 mm wall care putty and applying two coat of Distempering walls with distemper dry, white or tinted by brooming down or steel wire brushing ,scrapping down smoke shoot, moulds, mos and efflorescent salts and trading oil and greasy spots complete all as specified and directed.
M&L preparation of new surface and applying two coats of cement base paint,including necessary putting at new wall surface complete all as specified and directed .
Complete removal of existing treatment and applying two coats of cement base paint, white or tinted on old wall surface including preparation of surface.
Demolition of cement concrete in ground floor and pavings n.exc 15cm thickness (below or above ground level)
M&L for 75mm thick PCC type C-2 , 1:3:6 (40mm graded stone aggregate) al in plinth protection/ foot path finished even and fair without using extra cement all as directed
Demolition of cement concrete of any description and in any position not other wise specially provided for as in surface channel.
M&L for PCC type C-2 , 1:3:6 (40mm graded stone aggregate) al in surface channel.
Extra forming fair finished drain as in channel 30 cm inner grith in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc.
Taking down chowkat with shutter exc. 1.5sqm and n.exc 4sqm each complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 with using 20mm graded stone aggregate as in bed blocks for fixing holdfast or filling hollow space of steel frame etc all complete as specified and as directed.
M& L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required
Supply & fix as for steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay complete with glazing bars, dovetailed or welded all as directed by the Engr-in-Charge.
All as per item No 50 here-in-before but without glazing bars.
M&L for Framed work such as grills, framed guard bars,for window by welding it to existing window frame and similar work con- forming to Fe.290.Gde-E-165
M & L preparation of old surface & applying one coats of synthetic enamel paint wooden surfaces exc 10 cm girth all as specified and directed..
M&L for 100 mm thick cement concrete type C1 (1:3:6 ) Norminal mix as in subbase of floor etc and finished the complete all as specified and as directed.
M&L for 40 mm thick cement concrete type B1, 1:2:4 (20mm graded aggregate) as in flooring of floor etc and finished the spike rolling for vehicle to move including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and as directed.
INTERNAL/EXTERNAL ELECTRIFICATION Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
M&L for point wiring complete with 1.5 sqmm for independent board with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. (a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
(c) One socket out let 5/6 amps point on the same board
(d) One socket out let 5/6 amps point on the independent board
All as per item No 57.00 but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F switch piano flush type 5/6 amps single pole one way all as specified.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S & F deluxe fan Electronic regulator AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F, IP 20, class I, LED tube light fittings 20W (or nearest next higher wattage) (4feet), wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified.
S&F High Power LED street light fitting ,system wattage-35 Watt, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and impact resistance of IK07 with 10KV built in surge protection device using 2.5 Sqmm PVC insulated three core copper cable including taking down all as specified and directed.
Supply and Fixing MCB DB double door, powder coated sheet metal enclosure, 8 way 240 volts grade single pole and neutral with 200 amps rated bus bar,IP 20 protection fixed to wall using nuts & bolts and washer of suitable dia and grouted to wall using suitable gutties complete all as specified and as directed.
S&F MCB single pole & neutral 6 to 32 amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole 6 to 32 amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
M&L for Earthing complete with galvanised steel plate electrode of size 600x600x6.30mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soilwith and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and directed.
S&F street light bracket, made out of GI pipe medium grade) 32 mm bore, 1.2 m long bend to shape and fixing/grouting with wall using 2 Nos 25 x 5 mm size MS FI clamps with bolts, nuts & washers complete including drilling as necessary and two coats of Aluminium paint over a coat of Red oxide primer all as specified & directed.
S&F sub main wiring concelled type with single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS 694 of size 4sqmm nominal cross sectional area,1100 v grade and two run of 4sqmm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor and 4 sqmm multistranded copper counductor of green colour as continuous earth wire drawn in and including 25mm dia 'medium grade' PVC concealed conduits and fittings,complete including taking down of old sub main wiring all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F and testing PVC Insulated screened XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of of size 16 sqmm 4 core , providing lugs, straight through joints as required complete including jointing material as required and making connection of LT cables , including dismantling & taking out defective LT under ground PVC cable from trenches, cutting and removing defective parts complete all as specified and directed.:- Note:- Excavation & earthwork,sand cushoining,brick protection & GI pipe shall measured and paid separately,
M & L for sand cushioning/fdn filling with river Sand to underground cable/fdn (8 cm thick before laying and 15 cm thick after laying the cable/fdn punned to a thickness of 18 cm) complete all as specified and directed
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed
M&L for GI tubing 40 mm bore ,light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and directed.
M&L for horizental boaring across the road without distrubting the road surface for inserting GI pipe complete all as specified and directed Note- (i) Removal of surplus soil shall be deemed to be include in the unit rate (ii) GI pipe will be paid seperately Note- The contract sum shall be calculated by deducting the amount shown in credit schedule attached to this tender from total amount of schedule ,A,/BOQ
Supply, laying and testing PVC insulated 3 core multistranded FRLS Copper conductor 2.5 sqmm flat submersible cable 1100 volts grade including making connection to submersible motor, underwater lights etc complete all as specified and directed by Engr in charge
Supply, laying and testing PVC insulated 3 core multistranded FRLS Copper conductor 2.5 sqmm cable 1100 volts grade including making connection to lamp holders, focus lights, flood lights etc complete all as specified and directed by Engr in charge
Scrapping old existing LT panel and painting with two coat of aluminium paint inside and outside over a coat of red oxide primer complete all as specified and as directed by Engr in charge
Supply and fix 25W LED focus light environment friendly, new generation , energy saving, decorative IP66 LED spike light using COB LED as light source complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified.( Make- Havells Cat part no: LYCUSSPS25WLED730PSYMBOTG, Crompton, Bajaj or equivalent)
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified.
Supply and fix underwater 10 W led light with IP 68 protection or nearest next higher rating suitable for submerging into water, colour of light as specified by Engr in charge
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Tripple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete including provision of blanking plates as required and taking down the old one complete all as specified and directed by Engr-in-Charge.
S&F MCB, TPN 16 to 32 amps, 415 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
S & F three phse DOL Starter in sheet-steel enclosure motor rating ,415 V, 50Hz,3Ph of capacity 1-2 HP relay range 6- 9.3 A complete all as specified and directed by Engr-in-Charge. Make -L& T , Havells, BCH or equivalent.
S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed.
Supply and lay 3- layer PP-R (Polypropylene random copolymer) concealed pipes of outer diameter 90 mm SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches or above ground and connacting up with existing pipe using suitable PPR fittings complete all as specified and directed
Supply & lay 3- layer PP-R (Polypropylene random copolymer) concealed pipes of outer diameter 25 mm SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches or above ground and connacting up with existing pipe using suitable PPR fittings complete all as specified and directed
Supply & fix PP-R Gate valves (brass insert) of outer dia 25 mm as per requirement of the site complete all as specified and directed
Supply & lay medium grade rigid pvc conduit of inner diameter 20/ 25 mm for concealing of cables including all conduit accessories (ISI marked) as per site requirement . Make-Plaza, Finolex or equivalent Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
NARAYAN MAJUMDER
M/S SHIVNATH SINGH
samrat saw mill and joinery workshop
SS SHARMA
M/s. MD IRSHAD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .