Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
9 May 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM(PandP)UC
DGM(PandP)UC PD Administrative building FACT,Udyogamandal
Panel erection and miscellaneous electrical works related with IECPP commissioning and Energy Management system in AC-CPP-2023
2023_FACT_750456_1
3017/2023-2024/E27237
Limited
Miscellaneous Works
Item Rate
180 days
FACT, Udyogamandal
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹12,000
Yes
10 May 2023
25 Apr 2023
10 May 2023
25 Apr 2023
9 May 2023
25 Apr 2023
Dismantling of two numbers of existing Generator Control panel each of size: 1000 mm length X 1600 mm width X 2365 mm height ) in CPP Control Room and transporting the scraps to Material scrapyard inside FACT or any other location instructed by Engineer in charge. The work involves removing the existing cable terminations at terminal blocks/relays/meters, removal of cables from gland plates, debolting from existing foundation etc. For taking out the dismantled panels from CPP control room to outside removal of existing glass partitions is required. Removal and refixing of required portions of glass partitions is under contractor scope. Any modification required for existing false floor tiles shall be done by the contractor without any extra cost.
Dismantling of two numbers of existing Generator Relay protection panels each of size: 1000 mm length X 1000 mm width X 2315 mm height ) in CPP Control Room and transporting the scraps to Material scrapyard inside FACT or any other location instructed by Engineer in charge. The work involves removing the existing cable terminations at terminal blocks/relays/meters, removal of cables from gland plates, debolting from existing foundation etc.For taking out the dismantled panels from CPP control room to outside removal of existing glass partitions is required. Removal and refixing of required portions of glass partitions is under contractor scope.
Dismantling of two numbers of existing Generator AVR panels each of size: 1000 mm length X 1000 mm width X 2315 mm height ) in CPP Control Room and transporting the scraps to Material scrapyard inside FACT or any other location instructed by Engineer in charge. The work involves removing the existing cable terminations at terminal blocks/relays/meters, removal of cables from gland plates, debolting from existing foundation etc.For taking out the dismantled panels from CPP control room to outside removal of existing glass partitions is required. Removal and refixing of required portions of glass partitions is under contractor scope.
Erection of IECP panels(3 no.s of panels-Each panel of apprx size-800mm length x 1000 mm width x 2360 mm height) on fabricated MS frame . The work include the following: 1.Transportation of IECP panels from TG floor of AC-CPP building to inside the Control Room . 2.Fabrication of MS frame for fixing the panels. 3.Placing the panels over the MS frame and joining the compartments of IECP panels after checking the alignment and providing vibration pads. 4.The nut & bolts for panel joining and vibration pads will be supplied by FACT. Note: 1. The fabricated MS portion shall be painted with two coats of epoxy paint over a coat of epoxy primer. 2.Welding/cutting sets, welding rods,electrical junction boxes etc. and other necessary accessories for MS frame fabrication shall be arranged by the contractor.The structurals required will be supplied by FACT . The balance and/ or scrap material shall be removed from the work site and transported to scrap yard or to a location inside the company premises as suggested by the Engineer-in-charge of the job.Power supply required for the work will be provided by FACT free of cost. 2. The supply of paint and primer shall be under the scope of Contractor. Accepted makes of paints are Burger, Asian Paints, Shalimar and ICI Dulux.Thinner or any admixtures used with the paint items shall be only as per the manufacturer specification and with the approval of Engineer in charge.
Glanding and termination of armoured PVC multistranded Aluminium/Copper cables above 2 x 1.5 up to and including 4 x 4sq mm . The scope of work includes 1. Glanding of cables using single compression/double compression glands 2. Crimping using suitable Aluminium lugs, 3. Connecting the cables on terminals inside panel . Neccessary cable, cable glands and aluminium lugs will be arranged by FACT.
Glanding and termination of armoured PVC multistranded Aluminium/Copper cables above 4 x 4 up to and including 5 x 2.5sq mm . The scope of work includes 1. Glanding of cables using single compression/double compression glands 2. Crimping using suitable Aluminium lugs, 3. Connecting the cables on terminals inside panel . Neccessary cable, cable glands and aluminium lugs will be arranged by FACT.
Glanding and termination of armoured PVC multistranded Aluminium/Copper cables above 5x 2.5 up to and including 19 x 2.5 sq mm . The scope of work includes 1. Glanding of cables using single compression/double compression glands 2. Crimping using suitable Aluminium lugs, 3. Connecting the cables on terminals inside panel . Neccessary cable, cable glands and aluminium lugs will be arranged by FACT.
Termination of of unarmoured multistranded aluminium earth cable including and above 10 sq mm up to and including 70 sq.mm. The scope of work includes termination of cable using suitable aluminium lugs, connecting the cables on terminals/panel body etc.Cable along with cable lugs will be supplied by FACT.
Termination of of unarmoured multistranded aluminium earth cable above 70 sq mm up to and including 150 sq.mm. The scope of work includes termination of cable using suitable aluminium lugs, connecting the cables on terminals/panel body etc.Cable along with cable lugs will be supplied by FACT.
Glanding and termination of of armoured copper signal cable 1 pair X 1 sq mm . The scope of work includes 1. Glanding of cables using single compression glands 2. Crimping using suitable Aluminium lugs, 3. Connecting the cables on terminals on backside of energymeters inside panel . Neccessary cable, cable glands and aluminium lugs will be arranged by FACT.
Laying of armoured Signal Cable- 1 pair x1 Sq.mm. The scope of work includes transportation of cables to site, Installation of signal cables by laying on new/existing cable tray/rack / clamping on the wall /structure / routing under cavity floors / through GI pipe/trenches etc. The cables are to be laid inside HT/LT panels of CPP substation. Clamping shall be at interval not exceeding 0.5m using 25mmx2mm aluminium strips/cable saddles. Supply of all other items other than cable, required for the completion of work like Aluminium strips, nut & bolts etc shall be done by the contractor.
Laying and clamping of multistranded Aluminium/Copper cables above 2 x 1.5 sq.mm up to and including 4 x 4 sq.mm. The scope of work shall include laying and clamping of cables on walls/ ceilings, columns, beams, on structural etc. Clamping shall be at interval not exceeding 0.5m using 25mmx2mm aluminium strips/cable saddles. The scope shall include fabrication and fixing of cleats to the structure as required.. The work shall be done in a neat and aesthetic manner as directed by the Engineer in-charge. All materials except cable required for the work shall be supplied by the contractor including saddles/ aluminium clamps, screws,plug etc.
Laying and clamping of multistranded Aluminium/Copper cables above 4 x 4 sq.mm up to and including 5 x 2.5 sq.mm. The scope of work shall include laying and clamping of cables on walls/ ceilings, columns, beams, on structural etc. Clamping shall be at interval not exceeding 0.5m using 25mmx2mm aluminium strips/cable saddles. The scope shall include fabrication and fixing of cleats to the structure as required.. The work shall be done in a neat and aesthetic manner as directed by the Engineer in-charge. All materials except cable required for the work shall be supplied by the contractor including saddles/ aluminium clamps, screws,plug etc.
Laying and clamping of multistranded Aluminium/Copper cables above 5 x 2.5 sq.mm up to and including 19x 2.5 sq.mm. The scope of work shall include laying and clamping of cables on walls/ ceilings, columns, beams, on structural etc. Clamping shall be at interval not exceeding 0.5m using 25mmx2mm aluminium strips/cable saddles. The scope shall include fabrication and fixing of cleats to the structure as required.. The work shall be done in a neat and aesthetic manner as directed by the Engineer in-charge. All materials except cable required for the work shall be supplied by the contractor including saddles/ aluminium clamps, screws,plug etc.
Laying and clamping of unarmoured multistranded earth cables including and above 10 sq.mm up to and including 70 sq.mm. The scope of work shall include laying and clamping of cables on walls/ ceilings, columns, beams, on structural etc. Clamping shall be at interval not exceeding 0.5m using aluminium strips/cable saddles . The scope shall include fabrication and fixing of cleats to the structure as required.Wall openings for cable crossing and sealing the openings with cement after taking the cables through the openings shall also be in the scope of the contractor without any extra cost. The work shall be done in a neat and aesthetic manner as directed by the Engineer in-charge. All materials except cable required for the work shall be supplied by the contractor including saddles/ aluminium clamps, screws,plug etc.
Laying and clamping of unarmoured multistranded earth cables above 70 sq.mm up to and including 150 sq.mm. The scope of work shall include laying and clamping of cables on walls/ ceilings, columns, beams, on structural etc. Clamping shall be at interval not exceeding 0.5m using aluminium strips/cable saddles . The scope shall include fabrication and fixing of cleats to the structure as required.Wall openings for cable crossing and sealing the openings with cement after taking the cables through the openings shall also be in the scope of the contractor without any extra cost. The work shall be done in a neat and aesthetic manner as directed by the Engineer in-charge. All materials except cable required for the work shall be supplied by the contractor including saddles/ aluminium clamps, screws,plug etc.
Supply of wooden false floor ( cavity floor) tiles of size 600 mm X 600 mm and thickness 15 mm. The quantity shown is approximate only. The no. of actual quantities of tiles to be supplied will be conveyed by the engineer in charge of work.
Supplying 1.5 mm thick Vinyl flooring sheet of approved quality and colour and shade
Laying Vinyl flooring with departmental vinyl sheet already supplied by pressing down with even pressure until it adhere well to bed material using binding agent of good quality including cost of binding agent, labour etc complete as per instruction of Engineer In-Charge
Charges for providing services such as transporting and rearranging of electrical equipments/items, sorting/re-rolling/shifting of cables, cleaning of Power Control Centers/Electrical equipments, rearranging of Electrical store rooms, assisting departmental Craftsmen in Electrical Maintenance works, re-clamping of detached cables in cable trays etc., on 8 hours shift basis (Unskilled /semiskilled Labour supply) as directed by Engineer in charge.
Charges for supplying skilled and experienced Craftsmen having qualification of ITI/ Diploma in Electrical Engineering/valid wireman license issued from Kerala State Electricity Licensing Board to carry out Electrical works on 8 hour shift basis as directed by Engineer in charge.
PEEJESS ELECTRICALS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .