EE(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Provision of 1 Nos Semi High Mast lights pole with LED flood lights in Sindhu Farm Road, Meetha Pur village,Opp Mata Wala Gali in ward no 182 under Central Zone.
2026_MCD_282582_1
EE(Elect.)/CNZ/2026-27/14-12
Open Tender
Electrical Works
Percentage
30 days
ward 182
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹4,375
20 Jul 2026
2 Jul 2026
3 Jul 2026
2 Jul 2026
3 Jul 2026
2 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm | 33 | Mtr | 37 | ₹1,221 |
| 2 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm | 20 | Mtr | 28 | ₹560 |
| 3 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. | 1 | Each | 6,256 | ₹6,256 |
| 4 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 5 | Mtr | 42 | ₹210 |
| 5 | S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ). | 30 | Mtr | 247 | ₹7,410 |
| 6 | Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required. | 1 | Each | 2,564 | ₹2,564 |
| 7 | Supply of XLPE insulated, PVC sheathed Al. Conductor Armoured cable 1.1 KV grade confirming to IS-7098 of following Size (a) 2 X 6 Sq. mm | 53 | PM | 95 | ₹5,035 |
| 8 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd. | 12 | Per Sqm | 1,108 | ₹13,296 |
| 9 | Fabrication, Supplying, Installation, testing, Commissioning of 12 metres semi high mast System with its accessories, Mast shaft shall be in one section, hot dip galvanized 4mm thick(Single dip) Inside & out sides &sultable for wind velocity as per IS 875 part3.There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For seml High Mast head frame,2 point suspension system,5 X 2.5 sqmm Copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) 16 nos.and reinforcement of cold twisted bar of 8 mm dia 3700 mm (approx.) 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the semi high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB,1 . Double pole 16Amp. MCB etc as reqd. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS. | 1 | Each | 1,54,138 | ₹1,54,138 |
| 10 | Providing and fixing name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge | 1 | Each | 7,409 | ₹7,409 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.90 MB
Tendernotice_2.pdf
PDF • 0.76 MB
Tendernotice_3.pdf
PDF • 0.11 MB
Tendernotice_4.pdf
PDF • 0.24 MB
BOQ_329733.xls
BOQ • 2.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .