| 3 | L3₹64.0 L+₹8.7 L (15.7%)Rejected-Finance E 35 1 KAVI NAGAR INDUSTRIAL AREA GHAZIABAD U P 201002 | L3 | Rejected-Finance Quoted rates are higher |
Tender Value
₹52.4 L
EMD Value
₹1.0 L
Closing Date
17 May 2022, 3:00 pmClosed
Superintending Engineer IIT Mandi
Superintending Engineer IIT Mandi HP-175075
Construction of international robotics competition Lab at G.F. of A-10 building, construction of FDP lab in A-11 building, providing and fixing of zebra roller blinds in ACS, MANAS lab (innovation lab) at ground floor of A-09 building at North Campus
2022_IITMD_687527_1
IIT Mandi (CW)/SE-1266/22-23/1227-29 dt. 05-05-22
Open Tender
Civil Works
Works
60 days
North Campus of IIT Mandi
please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹1.0 L
10 Jun 2022
6 May 2022
18 May 2022
6 May 2022
17 May 2022
6 May 2022
6 May 2022 - 13 May 2022
Amount
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concreteas per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight (Only plan area of chajjas shall be measured for making payment). as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Powder coated aluminium (minimum thickness of powder coating 50 micron) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).6 mm thick Cement fiber board as per IS: 14862 as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
CEMENT PLASTER (IN FINE SAND)15 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing glazing in Upvc door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener,anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing includingthickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12mm dia as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with selfdrilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately) Outer face: Outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, Type A, as per IS:14862:2000 (high pressure steam cured) Inner Face :- 12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8 mm thick fibre cement board confirming to IS:14862:2000 of type B (High pressure steam cured) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and Fixing ZEBRA ROLLER BLINDS & complete with all component, including drilling holes in the wood work/RCC & installation at site. The ZEBRA Roller Blinds will have following specifications:Top channel extruded from Non rusting Aluminum alloy with 1.25 mm thickness, with anodization for long life. The Channel is designed with support beam to keep it straight and shall have a pocket for holding the fabrics in position. Available in 32 & 38 mm diameters for small and big blind respectively. Bottom Channel of ZEBRA Roller Blinds is again none rusting Aluminum powder coated with 1.50 mm thickness and 21 mm diameter. The fabric is enclosed in suitably created pocket along with tube. The channel shall be closed from sides with the end caps to give a neat look. Matching colors of bottom channel available to match with the fabrics. The tilt chain is made of unbreakable ABS plastic, 1.50 mm polyester cord with 4.50 mm balls. The blind can be stopped of desired position with help of stop lock. This operating mechanism is made of High strength ABS plastic, consists of an ultra smooth gear with spring booster. High carbon steel spring to transmit motion from driver to driven members. The mechanism shall be operating with the use of tilt chain. The Brackets are made of steel with powder coating to give smooth finish. Brackets shall be accommodated overhead or on side mounting with clutch assembly on either end of the blind.Fabric Specifications: Proton BlackoutComposition of Fab.100 % PolyesterVisibility Zero Light Transparent Zero Available Width 2.60 Mtrs Fabric Thickness 0.45 MM (+-0.05)Weight325 g/m2 (+-5%)Tearing Strength Very HighHanging Properties Excellent Cleaning Conditionally cleanable with damp cloth as per entire satisfaction and direction of Engineer -in-charge including carriage of material in all lead and lift.
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 3x2.5 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed PVC conduit/Wall Trunking/Casing as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 3x4 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit/Casing/Wall Trunk as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 6x4 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit/Casing as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 15/16 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 pin 5/6 A socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 pin 15/16 A socket outlet modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Module Modular base & cover plate on existing modular metal boxes etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 Module Modular base & cover plate on existing modular metal boxes etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing 125 A,36KA,FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 way Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 12 way Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 way (8 + 18), Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 8 way (8 + 24), Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing Single pole 5 to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole, in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 40 A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and installing 100 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of up to 35 Sq. mm size on Wall (Clamped with 1 mm thick saddle) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of up to 35 Sq. mm size on Cable Tray (Clamped with 1 mm thick saddle) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and copper lugs for 3 X 16 sq. mm (25mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 35 sq. mm (32mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying installation testing and comissioning of 3 Compartment wall trunk (170x57 mm) including JB, corner piece and bends complete in all respect as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Modue PVC box to be fixed in the existing Wall Trunking as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 Modue PVC box to be fixed in the existing Wall Trunking as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 4 Core x 6 Sq. mm of 1.1 KV Copper conductor XLPE Insulated,PVC extruded inner-sheathed, round wired armoured, overall PVC outer-sheathed (as per IS 7098 Part 1) with latest amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and Copper lugs for 4 X 6 sq. mm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 3 Core x 16 Sq. mm of 1.1 KV Copper conductor XLPE Insulated,PVC extruded inner-sheathed, round wired GI strip armoured, overall PVC outer-sheathed (as per IS 7098 Part 1) with latest amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 25 mm size of medium class PVC Casing-Capping along with accessories in surface as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, Installation, testing and commissioning of pre-wired, Square Recess Down Lighter(595x595 mm) of Wattage 36 W (6500K) directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Dismantling and Cleaning of Recesed/Surface Down Lighter with Cotton Cloth with full precaution taken as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and installation of GI fan rod of length up to 2.5 m per fan including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and installation of Ceiling fan (1200 mm Sweep) in white colour including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, Installation, testing and commissioning of 2 ton (3 Star) Split Inverter Hot and Cold AC including Voltage stabilizer , Outdoor unit stand ,complete with other accessories as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 4 Core x 6 Sq. mm of 1.1 KV Copper conductor XLPE Insulated,PVC extruded inner-sheathed, round wired unarmoured, overall PVC outer-sheathed (as per IS 7098 Part 1) with latest amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 3.5 Core x 35 Sq. mm of 1.1 KV Copper conductor XLPE Insulated,PVC extruded inner-sheathed, round wired unarmoured, overall PVC outer-sheathed (as per IS 7098 Part 1) with latest amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 32 mm size of medium class PVC Casing-Capping along with accessories in surface as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Dismantling of 3 Track wall Trunk and reinstalling and comissioning of same 3 track wall trunk including JB, corner piece and bends complete in all respect with all required accessories and making good the wall as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of F Frame 125 A FP MCCB Enclosure to Accommodate 3.5 core 35 sq mm unarmoured cable , directly on wall as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, installing , testing and commissioning of 200 amps (S.C. rating for 1 sec - 15 KA) 8 way, Copper Bus Bar Chamber. Make:- Havells, Schneider, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 12 way (8 + 36), Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and Copper lugs for 4 X 16 sq. mm size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 4 Core x 16 Sq. mm of 1.1 KV Copper conductor XLPE Insulated,PVC extruded inner-sheathed, round wired armoured, overall PVC outer-sheathed (as per IS 7098 Part 1) with latest amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Chopra Aluminium
Ghaziabad Mechfab Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .