| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L1 | Accepted-AOC ok | |
| 2 | L2₹5.8 L+₹14,870.40 (2.62%)Rejected-AOC WARD NO 5 THIRIYA NIZAWAT KHAN BAREILLY 243123 UP | BAREILLY | BAREILLY | UTTAR PRADESH | 243123 | L2 | Rejected-AOC ok | |
| 3 | L3₹6.4 L+₹68,131.77 (12.0%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹6.5 L+₹81,428.40 (14.4%)Rejected-AOC | L4 | Rejected-AOC ok |
Tender Value
₹9.9 L
EMD Value
₹19,850
Closing Date
15 Sept 2021, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/REPLACEMENT OF FLOOR TILES, JOINARY, WALL TILES, GATE, WHITE WASH AND ALLIED WORKS IN DAD RESIDENTIAL COLONY LEKHA NAGAR UNDER THE AREA OF AGE B/R-I AT GE (WEST) BAREILLY.
2021_MES_469185_1
8984/c/e8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹19,850
Yes
28 Sept 2021
19 Aug 2021
17 Sept 2021
19 Aug 2021
15 Sept 2021
2 Sept 2021
19 Aug 2021 - 1 Sept 2021
Amount
Demolition of brick or stone/boulder masonry, built in cement mortar.
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 using old size bricks.
Taking down existing cement plaster in cement mortar on brick/stone masonry walls etc incl racking out joints hacking for key scru bbing down with water all as specified (internal and external surfaces of manholes, septic tanks, etc).
M&L rendering 15mm thick on brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement.
M&L rendering 15mm thick on brick work or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement.
M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement
M&L for applying two coats of oil bound distemper over one coat of white wash on newly plastered surfaces including perperation of new plastering surface
M&L for 3 coats of white wash on newly plastered ceiling surfaces including preperation.
M&L preparation of newly plastered surfaces and applying three coats of white wash on walls over a coat of primer all as specified & directed by Engr-in-Charge.
M&L for preparation of old decorated surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old distempered surface of walls and applying one coat of distemper oil emulsion distemper complete all as specified and directed.
M&L for 1 coats of white wash on newly plastered ceiling surfaces including preperation
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
M&L for preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint complete all as spd and directed by Engr-in-Charge
M&L for non skid ceramic joint free colour tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.11 Sqm but not exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles.
M&L for 15 mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6
M & L Non - skid Ceramic joint free coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY
M&L for 10mm thick in CM 1:4 rendering/backing coat for skirting/dado on brick or concrete surfaces rough finished
M & L for colour printed glazed ceremic coloured tiles in vertical surface 300 x 200 x 6 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick screed bed or bedding layer of cement mortar 1:4 cement and dismantling of tile including cement mortar bedding complete all as specified or as directed.
Demolition of existing cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground level) all as specified.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for.
M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregate) as in slabs, colomns and similar work etc , set in CM 1:6.
M&L 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone agg in plinth protection, finished even and smooth w/o using extra cement.
M&L for Glass dividing strips, 3 mm thick 38mm wide as in floors
M&L for 40 mm thick cement concrete type B1, 1 : 2 : 4 (using 20 mm graded stone aggregate) in floor finishing surface with broom finishing as specified
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down door shutter of any description exc. 1 sqm but not exc. 2 sqm each complete all as specified and directed.
S & F second class hard wood (Sal) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S& F 35 mm thick second class hard wood glazed and Skelton door shutter open rebated and prepared to receive glass or gauge etc ( without sas bars) edge of framing plain chamfered or rounded filled with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I 1991 section 8 clause 8.24 (a).
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc.
S&F solid PVC Panel Door shutter 30mm thick style consisting of Frame made out of M.S Tube for top & Bottom rails, MS Frame shall be covered with heat moulded, Plain colour PVC’C’ channel having a PVC Sheets strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for Top rail, lock rail bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour 5mm thick PVC sheet fitted in the MS Frame, welded/ sealed to stiles and rail with suitable PVC sheet beading and jointed together with solvent cement all as per manufacture instruction all as specified.
S&F 100 MM Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21.
S & F 200 mm length of aluminium anodised barrel tower bolts of extruded section and fixed.
S & F 150 mm length of extruded aluminium alloy handles, fabricated type., anodised
S & F of 200 mm long (Length of bolt) mild steel barrel tower bolt stove enamelled black with bright bolt complete all as specified and directed.
S & F of 300 mm long mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts complete all as specified and directed.
S & F of 150 mm long mild steel pressed handle, oval type, stove enamelled black complete all as specified and directed.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone concrete or bricks surrounds glazed with putty or fixed with beads.
S&F 3mm thick sheet glass ordinary quality and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete.
S&F 3mm thick figured glass, pin head type andd glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of apreture 1.18 mm & fixed with tinned takce or galvanised wire staples fixed as in repairs.
Taking down steel gate of any size and refixing the same in position after repairs including greasing & oiling,making good loose brackets and welding work etc for proper functioning of steel gate repairs complete all as specified and directed.
M&L repair to chajjas by means removing loose/weak concrete materials and taking down old disturbed plaster from all sides ( bottom,top,sides, inc fin/facia of chajja etc ) cleaning with water allowed to dry and applying cement slurry 3.00 Kg/Sqm by brushing and fixing of chicken wiremesh of mesh size 25mm to 50mm, dia of wire 1.00mm to 1.40mm fixed with steel screws where required and then applying 10 mm thick rendering in CM 1:3 and finished even and fair and then applying three coats of white wash including necessary form work and scaffolding complete all as specified and as directed.
Cleaning of roof/ walls of any size buildings including complete removal plants grown with roots and treated with lime and filling the hole properly by cement mortar 1:3. Note: After completing the job user signature should be taken on record register
M & L for rubber moulded chequered cement concrete tiles of size 300X 300 X 25 mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor and laid over 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in sub base of floor.
Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
M&L point wiring with 1.5 Sqmm (FRLS) multi strand PVC insulated and unsheathed copper conductor cable concealed in PVC conduit 20 mm dia and including complete with 1.60mm thick pressed steel concealed galvanised terminal boxes and with top cover 3.0 mm thick ISI marked plastic laminated hylum sheet of reqd colour fixed with brass screws and cup washers, complete with all accessories and all as specified including 1.5 Sqmm (FRLS) PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth dolly for following.
(a) One light / fan/ exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket out let point on an independent board.
(c) One 5 pin 5 Amp socket out let point controlled by one switch on same board.
(d) One buzzer/ bell point controlled by one push button on the same board with other switches or independent
All as per item No. 51 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded complete all as specified.
S&F switch piano flush type 5 Amp single pole one way.
S&F socket out let 2 in 1 flush type 5 Amp 5 Pin complete.
S&Fswitch piano type 5/15 Amp flush type 240 Volt complete.
S&Fsocket out let 6 Pin 2 in 1, 5/15 Amp flush type 240 Volt complete.
S&F bell push flush type 5 Amp
S&F bell ding dong musical ,AC, 230 Volt, single pole
Taking down submain wiring and cables including all accessories complete all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm (FR) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FR) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6.0 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor shall be measured as one unit length.)
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed.
M & L for replacement of lamp holder, PVC / Poly carbonate, insulated body with back plate batten/angle type for batten fittings complete all as specified and & directed
Supply only LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed. Model -LTHPLED22W/B22 of Make C&S or equivalent in Philips/ Havells.
S&F MCB SPN 63 Amp 240 volt complete all as specified and directed by the Engr-in-Charge.CAT No. CSMBS1B40/63 N of Make C&S or equivalent in Legrand/ Scheneider.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed by the Engr-in-Charge.CAT No. CSMBS1B6-32 of Make C&S or equivalent in Legrand/ Scheneider.
Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links Cat part No CSDBSPNSD04 ofof C&S or Equivalent Model in Legrand / Schenieder as Approved by GE complete including taking down old unsv all as specified and directed.
Supply and fixing surface mounting LED indoor decorative PVC extruded T-5 batten , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed. Model : Cat No. LTTB4F20WLED P/W of Make-C&S, its equivalent model in Philips/CG/Bajaj
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced all as specified
Taking down, testing, repair and replacement of necessary item such as winding, bearing, bush, shaft, painting etc and refixing carefully serviceable ceiling fan of size 1200/1400 mm, 230V , AC type including provision of new single core twin twisted cable from ceiling rose to ceiling fan connector all as specified and directed by Engineer in Charge.
Supply & Fixing security light fitting, LED type, 25 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source with integrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed. Model-BCLST 20W LED of Make- BAJAJ or eqvlt in Philips/ Havells.
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 4 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
Supply and Fixing in repairs MCCB TPN 100 Amps, 415V, 16kA ,Thermal Magnetic Release
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 3.5 core as required at site.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
Sand cushioning for cables all as specified and directed . Note:-Punned sand layers meassured only.
Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
Notes:-
RIYASAT ALI KHAN
M/S Ishwar Builder
M/S SATISH KUMAR JAIN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .