Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.0 L+₹1.2 L (5.41%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹24.4 L+₹1.6 L (6.84%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹24.5 L+₹1.7 L (7.50%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹25.0 L+₹2.2 L (9.69%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
4 Feb 2023, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361150
MAINTENANCE OF PREPAID METERS, AUTO METER READING SYSTEM AND COMPREHENSIVE MAINTENANCE OF LIFTS AT INS VALSURA, JAMNAGAR
2022_MES_571573_1
8634/VAL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹38,800
Yes
30 Mar 2023
27 Dec 2022
6 Feb 2023
27 Dec 2022
4 Feb 2023
23 Jan 2023
27 Dec 2022 - 21 Jan 2023
Amount
Note :- Servicing, repair & maintenance of Automatic Meter reading system and Lifts shall be carried out through authorized service agency of Original Equipment Manufacturer (i.e M/s RDS/ Hitch Nick Automation and KONE respectively). The contractor shall submit documentary proof/evidence in this regard before execution of Work.
Providing one year license charges for cloud based online Automatic Meter Reading and Billing Software suitable for 2000 meters, data storage charges for storing meter details, billing data 615 meter for a period of 11 months to cloud server and Programming for modem of Electro magnetic water flow meter including network setting and time setting for sending daily reports/ data for both water meters including the following features. (a) Remote Monitoring and Reporting, (b) Billing, (c) email and alerts utility, (d) Meter reading shall be updated every 10 minutes (user settable), (e) Time stamp of last reading received. (with offline meter notification center), (f) Automatic bills generation at the end of period of category based consumers as directed by Engineer-in-Charge, (g) User settable billing format as directed by Engineer-in-Charge, (h) Facilitty to change/ add meter calculations of billing amount of bill generation of users at every end of specific period of category, (j) Monthly bills to be mailed to user if email ID of user exists in server, (k) Admin access can view and edit details of consumers, (l) Admin access can view periodic bills of any category of consumers and print them on demand, (m) Admin access can set consumer exit date of living quarter for generating manual bill of specific time period of consumer, (n) Supports common meter of building and calculate the amount of common meter energy charges will be distributed to all active consumers of that building.
Recharges of new SIM cards GPRS enabled and Electronic magnetic water flow meter recharge for 115 SIM Cards on monthly basis.
S&F in repairs external antenna for GPRS modem gain 9db for transmitting and receiving data to and from server. Make: RDS, Hitch Nick Automation
S&F in repairs Switched-mode power supply/ Voltage Converter for voltage supply to PIC circuit : 230V AC to 12V DC current.Make: RDS, Hitch Nick Automation
S&F in repairs PIC Microcontroller based single/ multiple meter monitoring module: Operating Voltage: 230V AC, Circuit Voltage 12V DC. Make: RDS, Hitch Nick Automation
S&F in repairs Pickup Phototransistor used for sensing the blinking of LED on digital electrical meter. Make: RDS, Hitch Nick Automation
S&F in repairs Communication modem between module and control centre (server): MQTT or HTTP over GPRS protocol. Make: RDS, Hitch Nick Automation
S&F in repairs cable 4 core PVC insulated unsheathed multistranded copper conductor of size 1.50sqmm (ISI marked) including suitable casing caping / PVC conduit etc. Make: Havells, Finolex, KEI
S&F in repairs master panel box including LED indication on display from front side of panel all as directed by Engr in charge.Make: RDS, Hitch Nick Automation
Cloud charges/transaction charges for prepaid energy meter for maintaining system smoothly working with making liason to dealer/authorise rep of HPL.
Annual Maintenance Charges for 40 Nos prepaid meter for 11 Calendar months which includes following : (a) Annual 9 Nos. of one day site visit will be counting in 11 Months AMC free of cost for any fault; Malfunction of meter will be check at site. Prepaid meter data programming related work will be done. (b) Energy meter software related update will be given as and when require. (c) Prepaid meter repair or rectification, Energy meter should be sent to HPL Factory for component repairing, but component charges will be extra as per HPL Electric & Power Ltd. (d) Site visit timing- 48 hours as when require for any fault in prepaid meter complete all as directed. (e) AMC to be carried out through authorised rep/dealer of OEM i.e. HPL complete all as directed.
Taking down old unserviceable single phase electronic energy meter/ Three Phase electronic energy meters of any make complete. Note: Old meter will be property of department and should be deposited to MES store by contractor.
S&F single phase AC Electronic energy meter 2 wire with LCD display, Rating 10-60A ,240 V, 50 Hz complete all as directed. Make: HPL Electric & Power Ltd Cat No. SPPB1510000000OC00 or equivalent of MECO, SECURE, L&T
S&F three phase AC Electronic energy meter 4 wire with LCD display, Rating 10-60A ,3 x 240 V, 50 Hz complete all as directed. Make: HPL Electric & Power Ltd Cat No. TPPL1510000000OCN0 or equivalent of MECO, SECURE, L&T
S&F Single Phase Two wire AC Static Enegy (10-60A) Direct Current class 1.0 keypad based pre-payment electronic energy meter with Customer Interface Unit (CIU) and Soft Token Transfer Device (STTD) comprising of 01 No. single source pre-payment meter +1 No. CIU without cable +1 No. STTD + Meter to CIU 2 pair shielded cable (1.5 meter length) including making necessary electrical connections and testing on completion as per manufacturer instructions complete all as directed. Make: HPL Electric & power Ltd Cat No. PSPB1523111000OC01 or equivalent of MECO, SECURE, L&T
S&F Three Phase four wire AC static Energy (10-60A) Direct Current class 1.0 keypad based pre-payment electronic energy meter with Customer Interface Unit (CIU) and Soft Token Transfer Device (STTD) comprising of 01 No. single source pre-payment meter +1 No. CIU without cable +1 No. STTD + Meter to CIU 2 pair shielded cable (1.5 meter length) including making necessary electrical connections and testing on completion as per manufacturer instructions complete all as directed. Make: HPL Electric & power Ltd Cat No. PTPB1521130000OC01 of equivalent of MECO, SECURE, L&T Note for item No 15 & 16 :(i) After installation & testing of Static Energy Meter it is the responsibility of the contractor to install soft ware for creation of portal/ database as per manufacturers recommendations and further to traine MES Personnel until they are conversant to prepare Consumer Data base, tarif creations, setting of load limit, meter allotment and any other information required to carry out the work as per manufacturers literature. (ii) One time transcation charges to be paid by contractor in advance for each meter @ Rs 40/ Meter (iii) Quoted rate for the said item is deemed to be inclusive of the above, no extra whatsoever shall be entertained at later date.
S&F in repairs Meter to CIU Cable RJ11 both End, 2 pair Shielded Cable.
M&L for carried out water testing report as per IS-10500:2012 with all required water container by Govt Authorised laboratory and submit Bactriological & Chemical report for 02 Nos. Sample (i.e. RO Plant Water & Potable Water)
Taking, down carefully copper/ aluminium point wiring (Light, Fan, socket or power) complete fittings such as switches, celling roses, pendants, regulators, sockets, MCB's, DB's and dispose the same under sch of credit etc complete.
M&L for concealed type point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No.20 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 20 here-in-above, but size of cable 4 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F switch modular type single pole one way 6 Amp with all accessories complete all as directed.
S&F switch modular type single pole one way 16 Amp with all accessories complete all as directed.
S&F socket outlet modular type 6 Amp, 2/3 Pin combined, 2 module with all accessories complete all as directed.
S&F socket outlet modular type 16 Amp, 2/3 Pin combined, 2 module with all accessories complete all as directed.
S&F Ceiling rose surface bakelite White/ Ivory/ Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
Taking down existing light fittings fixed in any description and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decorative end caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X020XC 20 W CCT 6500 or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
Taking down existing light fittings fixed in any description and S&F new 10 Watt wall mounted 2 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decorative end caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X010XC 10 W CCT 6500 or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
Taking down existing street light fittings fixed in any description with brackets and S&F LED street light 45 Watt in aluminium pressure die cast housing with touch glass cover (IP 66 protection) fixed over including 32 mm bore GI light grade bracket of size not less than 1.2 Mts long fixed to wall/ Steel/ concrete pole any height with GI clamps, any height including connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated and PVC sheathed 1100 V grade any length fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LSRT01SO45XC CCT 6000K or an equivalent of Bajaj/ Crompton/ Philips/ Wipro/ Havells. (Note: Quoted rate is deemed to be inclusive of GI bracket)
S&F angular lamp holder (ISI Marked), 230 V, PVC/ Polycarbonate type with back plate including 5 Watt LED lamp complete all as specified and directed.
S&F new BEE 3 Star rating ceiling fan 1200mm sweep, complete down rod and 3 core, 1.5 Sqmm copper conductor cable from ceiling rose to fan with all accessories and suitable size for down rod 230 V complete all as specified and as directed.
S&F step type eletronic fan regulator modular type 120 W, 2 module complete.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as directed by Engineer-in-Charge.
S&F exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, frame and louvers complete all as directed by Engineer-in-Charge.
S&F ceiling fan hook made of stainless steel bar size as required at site, 'D' Shape including locking pin type arrangement, nut bolt, washer, rubber but complete all as directed. Note: Ceiling fan hook sample shall be approved by Engr-in-Charge.
M&L for fan hook (D-hook hanger) heavy duty with M10 X 75mm fastener fix in existing ceiling as per direction and site requirement.
S&F in repairs sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 8 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F in repairs MCB SPN 40 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 18 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 92 to 4085 95 / Havells / L&T / ABB
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
S&F in repairs charging card for 15 kVA DSP based 3P-1Ph UPS. Make: APLAB
S&F in repairs Relay for 10 kVA DSP based 3P-1Ph UPS. Make: APLAB
S&F in repairs Relay for 15 kVA DSP based 3P-1Ph UPS. Make: APLAB
S&F 60Ah, 12 Volt battery suitable for Solar LED street light fitting complete all as directed. Make: Exide Solatubular battery type FE00-6LMS60 or equivalent in AMRON/ AMCO/ STAR GOLD
S&F in repairs 42Ah 12Volt Lead acid battery (Maintenance free battery with min 2 years warranty) for 10/ 15 kVA UPS including necessary connections complete. Make: Exide Powersafe plus or equivalent in AMCO/ AMPRON/ STAR GOLD
M&L for comprehensive maintenance and repairs of micro processor based controlled VVV frequency drive, electric driven Lift with ARD, Goods lift of capacity 1000 Kgs. installed at Dwarka Building serving ground plus 2 floors incl examining, adjusting, lubricating, greasing and replacement of u/s parts like hooter, fire switches, indication, emergency light, low voltage relay complete all as directed by Engineer-in-Charge. Note: (i) Comprehensive maintenance, repair and replacement of all spare parts and components fitted by KONE will be original parts or components fitted will be of equal quality and functionality as on when required shall be carried out only through authorised service agency of OEM under strict supervision of well experienced and qualified staff. (ii) The make of spares shall be shown as suitable for the existing system and shall be provided by authorized manufacturer's. (iii) The rates deemed to includes for all items which are not considered in schedule but the same is essential for smooth & efficient functioning of the lift costing less then Rs 400/- i.e. fuse, thumbles, connectors etc. (iv) The contractor shall keep all spares reqd for unserviceable spares parts replaced will be properties of the OEM and also the routine maintenance and attend the defects immediately. In case of major defects it shall be attended within 24 hrs failing which penal recovery @ 1000/- per day will be charged. The decision of GE will be final & binding in this regard.
Item No. 47 Contnd/- (v) The total Nos of Visit for normal servicing in general basis are 11 Nos (Monthly basis) and also Breakdown service covered during normal working hours (vi) spares parts listed in item No.48 to 54 will be measured and paid under relevant items separately as ordered. (vii) Contractor will be liable for defective unserviceable provide below mentioned items Sl No. (a) to (w) as and when required for maintenence of Lift or in breakdown condition for smooth & efficient functioning of Lift as per OEM requirement . The rates of spares & fitting deemed to be included in the quoted rates. (a) Drive module, KDL16R 20A 400V (b) LCECCBe Assembly (c) PCB, LCECPU NC Board V3F18 (d) ENCODER, MX D37.3 L2=4500 (e) Land Operating Panel, LOP-CB Assembly (f) LCE PCB Assembly (g) LCE CEB assembly (h) LCE COB Assembly (j) LCECIB,New LON Protocol. (k) Pit switch Sssembly, 1 NC 230VAC (l) UPS Device, 600VA 230V 1 PH (m) PCB,LOP230 Saftey Chain interface 1.2
Item No. 47 Contnd/- (n) AMD D10 Motor assembly (o)AMD D10 Spare Module ( Parallel ) - G03 (p) AVD7S assembly (q)Transformer, Drive 1 230V, 50/60HZ (r) Switch Contact, Slack rope Device (s) Switch Door contact 230VAC 2A (t)Tension weight, swing Arm OL35 (u)TL Jones Curtain of Light (v) Toothed Belt, Drive1 W = 12mm (w)Pully, Toothed belt D38.8mm W = 19.8mm
Supply and Fix in repair ARD batteries 7 AH 12 Volts
S&F in repair MCCB 120 Amps 415 V, 50Hz with adjustable thermal and magnatic setting of breaking capacity 36 KA . Make Legrand or equivalent all as specified and directed
S&F in repair ELCB 4 Pole three phase, 40 Amps 415 V, 50Hz of breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed
S&F in repair ELCB 2 Pole single phase, 25 Amps 230 V, 50Hz of breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed
S&F in repair MCB TPN 63 Amps 415 V, 50Hz of breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed
S&F in repair Car Blower Fan single phase supply 230 V ,50Hz all as specified and directed
S&F in repair Car LED Light single phase supply 230 V ,50Hz all as specified and directed
S&F Nitrile Rubber mat of best quality size in 1 meter x 2 meter x 10 mm
Supply, installation, testing and commissioning of floor mounted, indoor type, heavy duty, cubicle & compartmentalized, electric panel of dust and vermin proof, fully tropicalised construction, front openable doors and shutters with locking arrangement, made out of 2.0 mm thick CRCA sheet steel, factory fabricated, CPRI approved powder coated, suitable for operation on 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply complete with all interconnections and consisting of all accessories like Aluminium Bus Bar of capacity 200 Amps TPN, LED Type Indicating lamps, Push buttons, CTs, with multi function meter V,A, kWH, freq, etc. Danger Notice Plate, Lifting Hooks, Feeder Name Plates suitable for the following feeders (Note : The Panel shall be of suitable size to accomodate all the accessories mentioned below, installed on Pedestal made out of angle iron of size 50 mm x 50 mm x 6 mm & earth work, PCC foundation, suitable cable glands for cable entry etc.) :- 1.0 Incomer Feeder : (a) MCCB 100 A TPN 415 volts with micro thermal based with interrupturing breaking capacity 18 KA including all connecting accessaries like spreader terminal etc - 01 No 2.0 Outgoing Feeders : (a) MCB 63 Amps TPN C type - 01 No (b) MCB 32 Amps TPN C type - 04 Nos ( Pump Sets) (c) 15 Amps Pin type plug socket - 04 Nos (d) Multifunction meter 96x96 mm (e) 5 HP DOL starter of L&T or equivalant - 04 Nos (f) MCB 16 Amps DP - 03 Nos (For 15 Amps sockets)
M&L for Earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 32x6 mm GI strip means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected or indicated including testing on completion including necessary excavation, earth work, pcc pit, RCC cover, funnel with watering pipe 20mm bore medium grade, GI protection pipe 40 mm bore light grade and complete all as specified and as directed.
S&F earth continuity conductor or main earthing lead of Galvanised iron strip of size 32x6 mm, fixed on pole / wall from existing earth test point complete all as specified and as directed.
M/s Balaji Enterprise
Hirachand Sunderji and co
suvidhiconstruction
1R K Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .