Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹25.2 L+₹1.6 L (6.58%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹27.1 L+₹3.5 L (14.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹28.2 L+₹4.6 L (19.3%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹28.2 L+₹4.6 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹21.9 L
EMD Value
₹43,800
Closing Date
24 Nov 2023, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIRS/ MAINTENANCE OF E/M INSTALLATION AND OTHER MISC ALLIED WORKS AT INS KALINGA AND NAD BHEEMUNIPATNAM AND REPAIRS/ MAINTENANCE OF LIGHTING PROTECTION, EARTHING, FLAME PROOF FITTING/FIXTURE AND CONNECTED WORKS AT NAD BHEEMUNIPATNAM UNDER GE (P) N
2023_MES_611068_2
GE (P)/N/K/8045/23-24 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E Category b (i)
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer P Navy Kalinga Visakhapatnam
₹43,800
Yes
22 Feb 2024
3 Nov 2023
27 Nov 2023
3 Nov 2023
24 Nov 2023
10 Nov 2023
Amount
Taking down carefully existing aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification complete all as specified and as directed.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site complete all as specified and as directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
All as per Item no 3 here-in-before but for one fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item no 3 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 3 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item no 3 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed
Fixing only switch flush button single pole one way 5 amp all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
Supply and fixing socket combination 2 in 1 3 pin 5 amp flush type universal all as specified and as directed.
Fixing only switch socket outlet 5 amp flush type all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
Supply and fixing switch socket combination 2 in 1 3 pin 5 and 15 amp flush type universal all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
Fixing only ceiling rose surface bakelite three terminals all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed.
Fixing only fan regulator any type all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting energy efficient saving LED BATTEN LIGHT 18 /20 W 4' (feet) with incl LED Tube T8 Type long incl twin twisted copper conductor flexible wire from ceiling rose to connector with taking down old unserviceable one complete all as specified and as directed.
M & L for LED Tube 18 /20 watt Fixing in existing unserviceable tube light Fitting with taking down old unserviceable tube complete all as specified and as directed
M & L for LED Tube 10 watt Fixing in existing unserviceable tube light Fitting with taking down old unserviceable tube complete all as specified and as directed
Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1.5 m long bent to shape including bolt, nut,washer,clamp etc with taking down old unserviceable all as specified and as directed by the Engineer-in-charge.
S&F LED strip light 5 watt with suitable driver of same make fixing in false ceiling grooves at required site and installed by expert electrician and connect from existing incoming wire, including taking down old u/s complete all as specified and as directed.
Supply and fixing LED Flood Light 120 W, IP65 suitable for at Existing false Ceiling/ Pole/ wall/ Tower/ Ground with suitable size necessary fitting and fixture(hook/suspended rod of required size) existing electric incoming cable, incl taking down old u/s complete all as specified and as directed.
Supply and fixing LED highbay Light 150 W, IP66 suitable for at Existing false Ceiling /shed with suitable size necessary fitting and fixture (hook/ suspended rod of required size) existing electric incoming cable, incl taking down old u/s complete all as specified and as directed.
Supply and fixing LED lamp 40 Watt in repairs of existing lamp fitting any type and size,incl taking down old u/s, all as specified and as directed .
Supply and fixing lamp holder insulated body suitable for Retrofit lamp incl taking down old u/s, all as specified and as directed.
Supply and fixing sheet metal enclosure for two pin and earth plug and socket complete with one 20 amps MCB, incl taking down old u/s all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as incl taking down old u/s specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar all as incl taking down old u/s specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar all as incl taking down old u/s specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position incl taking down old u/s all as specified and as directed.
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position incl taking down old u/s all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 6 Sqmm and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 4 Sqmm and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 2.5 Sqmm and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs and supply and fixing New power contactor 3 pole AC control capacity 25 Amp, 220-240 coil volt, including the copper wire& copper lugs and testing complete all as directed.
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs and supply and fixing New power contactor 3 pole AC control capacity 32 Amp mounting type Din rail ,220-240 coil volt including the copper wire& copper lugs and testing complete all as specified and as directed.
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs supply and fixing power contactor 3 pole AC control capacity 30 Amp, MNX 12 TYPE, mounting type Din rail all as specified and as directed. Make :L&T MODEL No: CS94108 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs supply and fixing power contactor 3 pole AC control capacity 32 Amp, MNX 32 TYPE, mounting type Din rail all as specified and as directed.
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs supply and fixing Add-on auxiliary contact block single phase DC voltage 600 V power contactor 3 pole AC control capacity 25 Amp
Material & Labour for taking down the unserviceable contact block , supply and fixing new Add-on auxiliary contact block single phase DC voltage 600 V power contactor 3 pole AC control capacity 25 Amp Make : C&S or equivalent as approved by GE.
Material & Labour for taking down the unserviceable contact block, supply and fixing Add-on auxiliary contact block single phase DC voltage 600 V power contactor 3 pole AC control capacity 25 Amp Make : L&T Model No:- MNX-A2 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable Timer supply and fixing Timer mounting din rail rated voltage 230 V, IP 50 all as specified and as directed.
Material & Labour for taking down the unserviceable relay and S&F relays RT series wide range of AC and DC coil voltage high switching current capability and reliable, long operational , all as specified and as directed
Material & Labour for taking down relays , supply and fixing relays ,range 14 to 23 amps , MN series type MN2 high switching current capability and reliable, long operational, all as specified and as directed
Material & Labour for taking down relays and supply and fixing relays ,range 09 to 15 amps MN series type MN2 , high switching current capability and reliable, long operational , all as specified and as directed.
S&F in repair Digital Ammeter, 3 phase, 5 Amps, class 1, AC supply incl taking down old u/s ,complete all as directed.
S&F in repair Digital Voltmeter, 3 phase, 5 Amps, class 1, AC supply complete all as directed.
S&F MPD Power supplier of capacity 5-30 Amps auxiliary supply, 15 V, AC 230V, 50Hz, AC supply as fixed in repairs ,incl taking down old u/s complete all as directed.
Material & Labour for taking down the defective unserviceable solenoid valve coil and supply & fixing of new coil suitable to work in single phase, AC 220 V,50 Hz complete all as directed. Make :- Sporlaon / Sanlon
Taking down unserviceable single phase preventer and S&F new single phase preventer,6 wires,230 V complete all as directed.
Supply and fixing modular plate switch flush type, single pole one way 16 Amps 250 volts with suitable for existing model taking down old unserviceable one all as specified and as directed.
Supply and fixing modular socket 6 Amps 5 pin. with suitable for existing model taking down old unserviceable one all as specified and as directed.
Supply and fixing modular socket 6-16 amps 2/3 pin combined shuttered with suitable for existing model taking down old unserviceable one all as specified and as directed.
Supply and fixing modular step fan speed regulator 120 w ,2 module with suitable for existing model taking down old unserviceable one all as specified and as directed.
Supply and fixing modular plates white colour suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules all as specified and as directed..
All as per item No. 56 here-in-before but for 6 modules all as specified and as directed.
All as per item No. 56 here-in-before but for 3 modules all as specified and as directed.
All as per item No. 56 here-in-before but for 2 modules all as specified and as directed.
Comprehensive repair/maintenance electric operating system with gear and 3 phase 415 V for roiling shutter motor Dismantling the electrical connection from system and removing out the Induction Motor and Gear Box for Reconditioning /Overhauling Completely Transporting the Induction Motor capacity upto 1 HP to civil work shop and strip opening the motor and removing out the burnt out winding and cleaning of the stator core and rewinding with suitable size super enamelled copper wire with necessary insulations and varnishing becking and replacement of unserviceable ball bearing and assembling back the motor and re -fixing with gear Box and necessary electrical connections and testing and commissioning the rolling shutter all as specified and as directed.
Taking out old unserviceable earthing pit of any type complete with connected accessories including dismantling and removing materials from work site complete all as specified and directed.
M&L for Earthing complete with 3 m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 3 mtrs length buried directly and preferably vertically in ground with top flanged ended 2.5 mtrs below ground level welded/connected with GI strip 32×6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore in any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab and necessary testing on completion, complete all as specified and as directed . .
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick electrode and 32mm x 6mm galvanised iron strip as earthing lead buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
Material and labour for surface point wiring complete with 1.5 sq mm PVC insulated unsheathed FRLSH cable multistranded copper conductor 1100 V grade flame proof confirming to IS drawn through and including suitable dia stove Enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface on wall/ceiling /floors etc. for flame proof application connected upto light fitting/fan with and 1.5 sq mm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated. for flame proof application etc including testing on completion complete all as specified and as directed.
All as per item No. 64 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
S&F Flame proof rotary switch with separate cable terminal box including rubber gasket as per IS 2149, SP 16 amps , single pole, 250 volt, ISI marked for ON/OFF light made out aluminium alloy LM-6 marked in high tensile steel with anticorrosive epoxy paint grey shade CMRI certified with cable entries complete .
Fixing only in Flame proof switch single pole one way 5 amp all as specified and as directed. Note : Material obtained from item No 2 here in before shall be reused
Supply and fixing flame proof switch socket out let combined in LM6 cable termination box in LM6 16 A 250 V 2P+ Earth multipurpose 3 pin 15 amp and one 3 pin 5 amp controlled by one switch all as specified and as directed
Fixing only flame proof LM 6 16 A 250 V 2 P+ E all as specified and as directed. Note : Material obtained from item No 2 here in before shall be reused
Supply and fixing flame proof junction boxes 2/3/4 way suitable for 20 mm dia ERW steel including taking out old unserviceable junction complete all as specified and as directed by the Engr-in -charge.
Supply and fixing flame proof/ weather proof wellglass LED light fitting including tube suitable for 2x18 watt body made out of aluminium alloy LM-6 epoxy painted with wire guard , mirror optic reflector LED as per IS 13947 body made out of aluminium alloy LM-6 epoxy painted with guard ,reflector, flameproof clear glass along complete all accessories prewired CIMFR certified recommended for gas /vapour group IIA & IIB and zone 1&2 IP 65 protected and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall/ceiling including flameproof flexible wire from fitting to terminal point ,complete all as specified and as directed by the engr-in-charge.
Supply and fixing flame proof/weather proof wellglass LED light fitting suitable for 60 watt LED as per IS 13947 body made out of aluminium alloy LM-6 epoxy painted with guard ,reflector, flameproof clear glass along complete all accessories prewired CIMFR certified recommended for gas /vapour group IIA & IIB and zone 1&2 IP 65 protected and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall/ceiling including flameproof flexible wire from fitting to terminal point ,complete all as specified and as directed by the engr-in-charge.
Taking down unserviceable 40/20/10 W FTL flame proof fitting /well glass flame proof fitting/ any Watt LED and repair/replacement of old unserviceable spare with new spares, re-assembling and re fixing in existing position and connecting with existing point (accessories/spare required for replacement will be measured and paid separately against item no 74 to 78) all as specified and as directed by the engineer-in-charge.
Supply only 18/20 W LED Master tube light.
Supply only LED lamp 40 Watt of existing lamp fitting any type and size all as specified and as directed .
Supply only LED lamp 22 /23 Watt of existing lamp fitting any type and size all as specified and as directed .
Supply only LED lamp 15/18 Watt of existing lamp fitting any type and size all as specified and as directed.
Supply only holder suitable for FLP Well glass led light fitting all as specified and as directed.
Material and labour for sub main wiring with Four single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6.0 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with including taking down old unserviceable sub main wiring and cutting chases pinning and making good disturbed surface complete all as specified and as directed. NOTE: 5 runs of 6 Sqmm and one run of PVC conduit 25mm dia will be measured as one unit i.e. RM
Material and labour for sub main wiring with Four single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with including taking down old unserviceable sub main wiring and cutting chases pinning and making good disturbed surface complete all as specified and as directed. NOTE: 5 runs of 2.5 Sqmm and one run of PVC conduit 25mm dia will be measured as one unit i.e. RM
Material and labour for sub main wiring with Four single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with including taking down old unserviceable sub main wiring and cutting chases pinning and making good disturbed surface complete all as specified and as directed. NOTE: 5 runs of 1.5 Sqmm and one run of PVC conduit 25mm dia will be measured as one unit i.e. RM
Fixing only in repair and Flame proof switch single pole one way 15 amp all as specified and as directed.
Fixing only in repair flame proof switch socket out let combined in LM6 cable termination box in LM6 16 A 250 V 2P+ Earth multipurpose incl taking down old u/s all as specified and as directed
Supply and fixing flame proof switch socket out let combined in LM6 cable termination box in LM6 32 A 440 V 3P+ Earth, incl taking down old u/s all as specified and as directed
Supply and fixing in repair upto 36/42 W LED Power Driver for Downlighters, incl taking down old u/s all as specified and as directed.
S&F in repairs, LED Wellglass fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 35 Watt ,incl taking down old u/s complete all as specified and as directed by the Engineer-in-Charge.
Testing of earth Resistance of existing earth pit as and when required using earth resistance testing equipments as directed by the Engr-In- Charge and producing the test result for recording purpose all as directed by the Engr in Charge. Note: 1)The contractor shall be asked to carry out the Earth Test as and when required as a whole or as a part of the qty. 2) Testing of each earth pit shall be measured as one unit. 3)All test result to be entered in a register properly bound and covered and to be submitted to the Engr-In-Charge 4) For the purpose of testing contractor shall supply all equipments and apparatus/instruments at his own cost without any extra claim ]
Material and labour for repairs to Earth pit including replacement of broken RCC cover by new 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar)and other allied works as directed by the Engr in Charge
Taking down strip from earth pit and testing of resistance of existing earth pit of lightning conductor for its continuity through skilled electrician and helper using digital earth resistance tester to check the healthiness of earthing system in and including nut bolt with brass nut bolts as per required size and other necessary tools, plants and equipments including rectification of the discontinuity by providing new lightning conductor or refixing the displaced existing lighting conductor in place as required on top priority as and when required including necessary minor repair work as required during rectification complete all as directed by the Engr-In- Charge and producing the test result for recording purpose all as directed by the Engr in Charge. . Note: 1) Testing of each earth pit shall be measured as one unit. 2) All the materials required to complete the work at site such as wooden plugs, Nut, bolt, Washers, shaddles,fixing screw etc shall be provided by the contractor and deemed to be included in the rate quoted. 3) New material such as Air terminal, GI/Aluminium strip shall be measured and paid separately . 4) Pouring of water and salt in Earth pit deemed to be included in the rate quoted necessary arrangement to be made by the contractor . 5) For the purpose of testing contractor shall supply all equipments and instruments at his own cost without any extra claim]
Taking out of old air termination rod of any type and any size from building including dismantling and removing (except serviceable strips for re-fixing) materials from work site complete all as specified and directed.
Supply and fixing air termination single pointed, aluminium rod 12mm dia and 300mm long fixed on galvanised iron pipes with copper/ aluminium/ GI strip for earth conductivity to ground complete all as specified and directed.
Re-fixing of old serviceable tilted air termination rod of any size and type after straightening & dressing with and including suitable nut, bolts and washers to earth strip complete all as specified and directed. (Note: Pipe/ PCC work shall be measured and paid separately).
Taking down old Copper/ GI/ Aluminium Strip of any size and any type from building/hangar (roof/down conductor)/ pipe/ trench including dismantling and removing (except serviceable strips for re-fixing) materials from work site complete all as specified and directed.
Supply and fixing copper strip 20 mm x 3.5 mm with fixing screws for conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed.
Supply and fixing galvanised iron strip 32mm x 6mm with fixing screws for conductors/ earth lead including welding and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed.
Supply and fixing aluminium strip 25mm x 3mm with saddles and fixing screws for roof/ down conductors above ground level complete all as specified and directed.
Re-fixing of old serviceable (serviceable strips as obtained from taking down) Copper/ GI/ Aluminium Strip of any size and type after straightening & dressing with and including saddles/ insulators with screws for fixing and making good disturbed strip complete all as specified and directed.
Taking out of old unserviceable test point terminal block of any type and any size including dismantling and removing materials from work site complete all as specified and directed.
M&L complete for test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 nos. 8 mm dia 25mm long hex, head screw all as specified and directed.
Supply and fixing in replacement of GI funnel with wire mesh for earthing pits of existing size complete all as specified and directed.
M&L for checking the serviceability including loose contact and condition of cable terminations of all the existing Flame proof MCCB/MCB DBs at any magazine building/any place once in three months and opening a DB serviceability register and recording building wise including obtaining rep of users signature in the register complete all as specified and as directed. Note:- The checking shall be carried out in presence of user/user rep. One time checking including entering in the register is considered as one job.
Supply and fixing flame proof/weather proof wellglass LED light fitting suitable for 40 watt LED as per IS 13947 body made out of aluminium alloy LM-6 epoxy painted with guard ,reflector, flameproof clear glass along complete all accessories prewired CIMFR certified ,recommended for gas /vapour group IIA & IIB and zone 1 & 2 IP 65 protected and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall/ ceiling including flameproof flexible wire from fitting to terminal point ,complete all as specified and as directed by the engr-in-charge.
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick electrode and 4mm galvanised iron/GI wire as earthing lead buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire of 4mm dia earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
F AND M TECHNOLOGIES
SREE DURGA INFOTECH
SRI RAJA RAJESWARI ENTERPRISES
SRI SAI KRISHNA ENGINEERING WORKS
SHIKHARA PROJECTS
SRI SRK ENGINEERS
ANAND ENTERPRISES AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .