Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC 5 IGM HOSPITAL LANE AGARTALA WEST TRIPURA | ₹16.9 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹17.8 L+₹86,355 (5.11%)Rejected-AOC 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹17.8 L+₹86,355 (5.11%) | L2 | Rejected-AOC BEING L2 |
| 3 | L3₹18.5 L+₹1.5 L (9.11%)Rejected-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹18.5 L+₹1.5 L (9.11%) | L3 | Rejected-AOC BEING L3 |
| 4 | L4₹18.6 L+₹1.7 L (10.2%)Rejected-AOC NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹18.6 L+₹1.7 L (10.2%) | L4 | Rejected-AOC BEING L4 |
| 5 | L5₹18.7 L+₹1.8 L (10.5%)Rejected-AOC K60 ROSHANPURA NAJAFGARH NEW DELHI SOUTH WEST DELHI 110043 | WEST | DELHI | 110043 | ₹18.7 L+₹1.8 L (10.5%) | L5 | Rejected-AOC BEING L5 |
Tender Value
₹23.3 L
EMD Value
₹46,516
Closing Date
18 Nov 2022, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation and Commissioning of Air Conditioning Machines for Air conditioning system at new Dining Hall and others conference Hall AND rooms of Pragya Bhavan during ensuing visit of Honble Prime Minister of India
2022_CEPWD_33763_1
79/EE/DNIeT/MECH.DIVN/AGT/202
Open Tender
Electrical Works
Works
30 days
agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹46,516
16 Jan 2023
10 Nov 2022
18 Nov 2022
10 Nov 2022
18 Nov 2022
10 Nov 2022
Amount
Providing of Split type High wall 2.00 TR (6,000 Kcal/ hr.) split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe) suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.
Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation, clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge.
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes or suitable creadle i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable.
Providing of 4 to 4.5 TR(not less than 12000Kcal/hr) Vertical split AC machine with Inverter Compressor technology operating & hermitically sealed compressor operating on R22/R-410 A /non CFC equivalent refrigerants suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) cooling, B) Dehumidify, C) Air circulation, d) Filtering. etc. complete as per direction of Engineer -in- charge.
Installation and commissioning of 3 TR /4/4.5 TR vertical split AC unit with vaccumising, Nitrogen pressure testing, first charge of refrigerant including providing Refrigerent & cable connection from MCB to Outdoor/indoor etc. (upto 3mtr) complete as per direction of the Engineer in Charge .
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. 3/4" OD / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. 1/2" OD / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing and fitting-fixing of VI pad for outdoor unit for Vertical split AC unit as per direction of the Engineer in Charge .
Providing, fitting & fixing of cradle/suitable structure (Base) made of M.S. angle of 65 x 65 x 6 mm, nuts & bolts etc. i/c painting, fitting, fixing, grouting for placement of outdoor unit complete for vertical split AC as per direction of the Engineer-In-Charge.
Providing, fitting & fixing of suitable structure (Base) made of M.S. angle of 65 x 65 x 6 mm, nuts & bolts etc. i/c painting, fitting, fixing grouting for placement of indoor unit, the M.S base should be enclosed by 12 mm water proof ply with formica pasting/ACP sheet complete for vertical split AC as per direction of the Engineer-in-charge.
Providing & Fitting fixing of Electric Control cable (5 core) suitable for connectin between MCB to Outdoor unit / indoor unit etc complete as per direction of the Engineer-in-charge. 5Cx 4.0 sq.mm cu cable
Providing Additional Refrigerant gas to the AC units as per direction of the Engineer-in-charge.
STANDARD ELECTRONICS
R.P.ELECTRONICS
Eastern Commerce
Accurate Engineers
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_34302.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .