Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC | ₹2.6 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.8 Cr+₹15.7 L (6.04%)Rejected-Finance CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | ₹2.8 Cr+₹15.7 L (6.04%) | L2 | Rejected-Finance Rejected being L2 |
Tender Value
₹2.1 Cr
EMD Value
₹3.1 L
Closing Date
4 Sept 2020, 6:00 pmClosed
CE NW Kochi
Kataribagh, Naval Base, Kochi-682004
PROVISION OF SIMULATOR BUILDING AT OBSERVER SCHOOL INS GARUDA NAVAL BASE KOCHI
2020_MES_367408_1
890935
Open Tender
Civil Works
Lump-sum
365 days
Kochi
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (P NW Kochi
₹3.1 L
Yes
12 Oct 2020
7 Aug 2020
8 Sept 2020
7 Aug 2020
4 Sept 2020
21 Aug 2020
8 Aug 2020 - 15 Aug 2020
Amount
LIST OF WORKS
Schedule A Part I( to Part XIV)
Total amount of Sch 'A' part-I (Buildings & Structures)
Total amount of Sch 'A' part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' part-III (Internal Water Supply)
Total amount of Sch 'A' part-IV (Internal Electric Supply)
Total amount of Sch 'A' part-V (Road/Path/Hardstanding)
Total amount of Sch 'A' part-VI ( RCC Box Culvert)
Total amount of Sch 'A' part-VII (Sewage Disposal)
Total amount of Sch 'A' part-VIII(Area Drinage)
Total amount of Sch 'A' part-IX (External water supply)
Total amount of Sch 'A' part-X(External Electric supply)
Total amount of Sch 'A' part-XI(Air Conditioning)
Total amount of Sch 'A' part-XII(Lightning Protection)
Total amount of Sch 'A' part-XIII(Fire Fighting)
Sch 'A' Part- XIV (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Material and labour for Boring for cast-in-situ bored piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Material and labour for RCC with ready mix concrete(RMC) M30 grade as per IS-456 using 20mm graded stone aggregate in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items (ii)The quoted rate for this item is deemed to be inclusive of charges for non destructive test.
Material and labour for RCC with ready mix concrete(RMC) M30 grade as per IS-456 using 20mm graded stone aggregate in cast in situ pile cap, grade beam/tie beam complete all as specified and shown on drg. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 10mm dia conforming to IS-1786 as in stirups for pile caps and gared beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 10mm dia conforming to IS-1786 as in Helicals for piles including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for Ring/Stiffener for piles all as shown on drg including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 500mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m deep and not exc 3M or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance not exceeding 1.5KM and not exc 5KM and depositing where dircted at a level not exc 1.5 m above starting point all as specified and as directed.
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified and as directed by the Engineer-in-Charge.
Demolition of existing pump house and sump including foundation and connected electrical/water supply line fitting and fixtures complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of existing temporary parking shed including foundation and connected electrical fitting complete all as specified and as directed by the Engineer-in-Charge.
Felling of trees exc 30cm and not exc 100cm in girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance not exc 50M and clearing site complete all as specified and as directed by the Engineer-in-Charge.
Felling of trees exc 100cm and not exc 150cm in girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance not exc 50M and clearing site complete all as specified and as directed by the Engineer-in-Charge.
Cutting opening through brick walls for door, window and other openings or enlarging existing openings in cement mortar complete all as specified and as directed by the Engineer-in-Charge.
Desilting of mud from existing drain complete all as specified and as directed by the Engineer-in-Charge.
Removal of desilted material at a distance exc 250m but not exc 500m complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Forming jambs etc to opening including cutting toothing and properly bonding in to old work, also facing, jointing and pointing to match existing work complete in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 5.5mm thick sheet glass, ordinary quality and glazing with rubber bidding in square exc 0.5sqm in each pane complete in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Renewing ceramic tiles in patches, area not exc 5Sqm including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Door closer aluminium body hydraulically regulated, designation no 3, universal type suitable for door shutters of 851 to 1000mm in width and weight between 36 to 60kg all as specified and as directed by the Engineer-in-Charge.
Supply and fix Brass mortice lock, vertical type of size 100mm 4 levers all as specified and as directed by the Engineer-in-Charge.
Material and labour for 150mm thick WMM(Compacted thickness)(in two layers of 75mm thick in each layer)with granite/trap coarse aggregates of grading 2(63mm to 40mm size) or grading 3(50mm to 20mm size) spread, rolled and consolidated to camber and gradient required complete all as specified and as directed by the engineer-in-Charge.
INTERNAL ELECTRIFICATION:Supply and fix Ceiling fan 1200mm sweep copper wound having minimum 5 star rating , including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sqmm from ceiling rose/ connector to fan all as specified and as decided bythe Engr in charge.
Supply and fix Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound motor and PVC louvers, including connecting up from ceilinf rose with 3 core flexible copper cable, PVC sheathed of size 1.5 Sqmm all as specified and as directed by the Engineer-in-Charge. Make for items 49 & 50 : Bajaj/ Crompton/Khaithan
Supply and fix LED Batten light fitting 22W with extruded aluminium housing provided with polycarbonate diffuser and integrated electronic driver complete all as specified and as directed by the Engineer-in-charge. Make:- Havells model Endura Linear Neo or eqvt in Philips/Wipro/ Osram
Supply and fix LED Batten light fitting 10W with extruded aluminium housing provided with polycarbonate diffuser and integrated electronic driver all as specified and as directed by the Engineer-in-Charge. Make:- Havells model Endura Linear Neo or eqvt in Philips/Wipro/ Osram
Supply and fix LED recessed type light fitting 42W with aluminium housing and diffuser and electronic drive suitable for Armstrong/ Grid ceiling of size 595mmx595mmx65mm or 2'x2' all as specified and as directed by the Engineer-in-Charge. Make: Havells model Venus Neo HE or eqvt in Philips/Wipro/ Osram
Supply and fix LED street light fitting with pressure die cast aluminium housing and acrylic cover as diffuser, having IP 66 protection of 30 Watt complete including fixing with GI Bracket made of 43mm outer dia GI Pipe including fixing clamps etc and wiring from junction box/ceiling rose with 3 core flexible copper wire, 1.5Sqmm complete all as specified and as directed by the Engineer-in-Charge. Make: Havells model Endura Citylite Platinum or eqvt in Philips/Wipro/ Osram
Supply and fix vertical DB 8 way,TPN, double door , suitable for MCCB 4 Pole as incomer, with bus bar, neutral links and blanking plates etc all as specified and directed by Engr-in-Charge Note :- Incoming MCCB and Out going MCB shall be measured and paid seperately under relevant items.
Supply and fix MCCB 4Pole with fixed thermal and magnetic settings, 100 Amps, 415 Volt 50 HZ 16 KA all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB TP 40 Amps "C" Series all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB TPN 40 Amps "C" Series all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP 06 to 32 Amps "C" Series all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 06 to 32 Amps "C" Series all as specified and as directed by the Engineer-in-Charge. Make for Item No 44 to 48:- Havells/L & T/Legrand/BB/Siemens/Schneider[DB, MCB & MCCBs of same make shall be used.]
Supply and fix GI metal flush boxes 2 module all as specified and as directed by the Engineer-in-charge.
Supply and fix RJ 11 telephone socket 1 module with cover plate all as specified and as directed by the Engineer-in-charge.
Supply and fix TV socket 1 module with cover plate all as specified and as directed by the Engineer-in-charge.
Dismantling of unserviceable armoured/ unarmoured cable upto 50 Sqmm complete all as specified and as directed.
Taking down of unserviceable DB with MCBs complete all as specified and as directed.
INTERNAL WATER SUPPLY :- Supply and fix Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for CPVC pipe 15 mm dia bore ( for wash basin, flush tank and water cooler inlet)complete all as specified and as directed.
EXTERNAL WATER SUPPLY:-Dismantling pumps of capaity 3 HP (2 Nos.) and connected pipe lines, foot valves, gate valves, etc., from the existing pump house and to the sump and electric supply panels, shifting and installing in the new location as directed including rerouting of existing pipe lines etc all as directed at site. Note: Extra pipes used shall be measured and paid under corresponding items.
Material and labour for Valve chamber 900X900X900 mm size internally built with brick work in CM 1:6 plastering complete with CM 1:4 including necessary earth work, PCC 1:4:8, 100 mm thick as in foundation concrete including provision of cast iron hinged cover with using 2mm thick steel with "FH" empossed and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed
Taking up or down steel water tubing of size 80mm and connections, including cleaning for refixing or removal to store all as specified and as directed.
Taking up or down PP-R water tubing of size 75mm and connections, including cleaning for refixing or removal to store all as specified and directed.
Cutting existing steel tubing, screwing for alterations or additions (or lengthening screw on pipe to form connector) in position without taking down all as directed at site.
External Electric Supply:- Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA including extension in existing LT panel and all connected works as directed at site.
All as per Item No 73 herein before but with following items(LT panel 2) (a) Bus bar RYBN 200 Amp capacity - 01 Set (b) MCCB 100 Amp 4 pole adjustable 25 KA 415 Volt ( Incoming) - 01 No (c) MCCB 63 Amp 4 pole 25 KA 415 Volt - 02 No (d) Onload changeover 63 Amps TPN -01No (e) MCB 0-32 Amps 10 kA SPN -04 Nos (f) LED Indicator lamp RYB - 02 Sets (g) Digital multifunction meter (V, A, F, PF, KW, KVA)
All as per Item No 73 herein before but with following accessories. (LT panel 3) (a) Bus bar RYBN 200 Amp capacity - 01 Set (b) Onload changeover 63 Amps TPN -01No (c) MCCB 63 Amp 4 pole 25 KA 415 Volt - 01 No (d) MCCB 40 Amp 4 pole 25 KA 415 Volt - 03 Nos (e) LED Indicator lamp RYB - 04 Sets (f) Digital multifunction meter (V, A, F, PF, KW, KVA)
Supply and fixing LED street/Security light fittings, new generation energy saving and environmental friendly long life versatile die-cast aluminium IP 65 luminaire with high power LEDs 75 watts heat resistant toughened glass with frame including suitable size copper multistranded cable for connection from junction box at the bottom of the pole, suitable size GI tubes maximum up to 1.5 meter and all as directed.
Supply and fixing KD thermoplastic junction boxes IP 65 with metric knockouts for cable entry and four terminals suitable for LT cable up to the size 4 core 50 sqmm and the size of the box is 210mm x 310 mm x116mm including connectors and SP MCB all as directed at site.
Supply and fix hot dipped galvanized octagonal pole(wall thickness 3mm)8 meter long including PCC foundation as per manufacturers specification complete all as specified and as directed by the engineer-in-Charge.
AIR CONDITIONING:-Supply and install hi wall split inverter type AC units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5Star rating of capacity 1.5TR all as specified and as directed by the Engineer-in-Charge.
Supply and install hi wall split inverter type AC units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5Star rating of capacity 2TR all as specified and as directed by the Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA
WATER COOLER:_Supply , Installation, commissioning water cooler of fully stainless steel, electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour all as specified and as directed by the Engineer-in-Charge.
FIRE FIGHTING:-Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia all as specified and as directed by the Engineer-in-Charge.
Supply and fix wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours all as specified and as directed by the Engineer-in-Charge.
Supply and fix Air cushioning tank(Air vessel)250mm diax1000mm high with dished top made of minimum 6mm thick MS pipe/plate complete with 20mm dia. Brass air valve(ball type)20mm dia stop valve pressure guage with brass stop cock, nipple tees elbows and all accessories complete all as specified and as directed by the Engineer-in-Charge.
Supply and install LT control panel floor mounting type fabricated from 2mm thick CRCA sheet powder coated dust and vermin proof complete with aluminium bus bar of capacity 100Amps and with the following accessories:- (a) MCCB TPN 63Amps 4 pole as incoming-1No (b) MCB TP 32Amps "C" curve 10KA-2Nos (c) Power contactor suitable for 7.5HP motor with OLP-2Nos (d) Multifunction meter -01No (e) Single phasing preventer -02 Nos (f) Phase Indicating lamps RYB - 1 Sets(LED type) (g) Provn of Pressure switch-2Nos
Classic Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .