| 1 | L-1₹34.9 LAccepted-AOC 16 20 GALI NO 7 8 SWAROOP NAGAR EXTENSION DELHI 110042 | DELHI | NORTH DELHI | DELHI | 110042 | ₹34.9 L Quoted ₹37.2 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹38.5 LRejected-AOC | ₹38.5 L | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹43.8 LRejected-AOC | ₹43.8 L | L-3 | Rejected-AOC L-3 |
| Sl No | Description | Qty | Unit | KKP Enterprises L1 | Sanjay Associates L2 | m/s Kailash Chander L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.Note: Rate also includes for necessary scaffolding/Jhoola work to carry out work upto a hight G+7 floor. | 450 | Sqm | 20 ₹9,000 | 22 ₹9,900 | 23 ₹10,350 |
| 2.00 | M&L for 10mm thick cement plaster on brick wall concrete wall surface in CM 1:4 finished even and smooth surface without using extra cement mixing with liquid WPC complete all as specified and directed.
Note :-(i) Water proofing compound shall be paid separately
(ii) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor. | 100 | Sqm | 140 ₹14,000 | 145 ₹14,500 | 142 ₹14,200 |
| 3.00 | M&L rendering 15 mm thick in CM (1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed. Note:-
(i) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor | 300 | Sqm | 120 ₹36,000 | 115 ₹34,500 | 145 ₹43,500 |
| 4.00 | M&L for 5mm thick cement plaster on brick/concrete ceiling surface in CM 1:3 finished even and smooth surface without using extra cement mixing with liquid WPC complete all as specified.
Note :-(i) Water proofing compound shall be paid separately
(ii) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor. | 50 | Sqm | 155 ₹7,750 | 160 ₹8,000 | 125 ₹6,250 |
| 5.00 | M & L Preparation of newly plastered surfaces of walls and apply two coats of oil bound distemper over a coat of alkali?resistant primer including 2mm wall putty all as spd and directed. | 100 | Sqm | 93 ₹9,300 | 90 ₹9,000 | 100 ₹10,000 |
| 6.00 | M & L Preparation of newly plastered surfaces of ceiling and apply two coats of oil bound distemper over a coat of alkali primer including 2mm wall putty all as spd and directed. | 50 | Sqm | 42 ₹2,100 | 45 ₹2,250 | 50 ₹2,500 |
| 7.00 | M&L for applying one coat of oil bound distemper on walls including preparation of old decorated surfaces including filling minor holes with wall care putty and including brooming down or steel wire brushing, scrabing down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots complete all as specified and as directed | 1,200 | Sqm | 35 ₹42,000 | 37 ₹44,400 | 40 ₹48,000 |
| 8.00 | Complete removal of existing treatment from internal / external plastered or unplastered surfaces of walls complete all as specified and directed | 2,000 | Sqm | 9 ₹18,000 | 10 ₹20,000 | 20 ₹40,000 |
| 9.00 | M&L for 2mm thick layer(Each coat min 1mm thick) of white putty on scrapped/uneven surfaces of any description to match with the existing surfaces before application of white wash/distemper/cement base paint/Apex paint etc complete all as spd and directed
Make : JK Wall care putty/Birla white putty or equvalent | 2,000 | Sqm | 20 ₹40,000 | 22 ₹44,000 | 40 ₹80,000 |
| 10.00 | M&L for applying two coat of oil bound distemper on walls after completion of putty work (if required on site) and including preparation of surfaces and including brooming down or steel wire brushing, scrabing down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots complete all as specified and as directed
Note : Putty work shall be paid separtely in relivent items. | 2,000 | Sqm | 25 ₹50,000 | 30 ₹60,000 | 45 ₹90,000 |
Updated dates
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
16 Jan 2026, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
MISC REPAIR TO SECURITY WALL GATE FENCING PATH HARD STANDING ETC TO RESIDENTIAL AREA ZONE A AT KWC AND REPAIR AND MAINTENANCE OF STREET LIGHT BLDG SECURITY LIGHT AT METCALFE HOUSE AREA UNDER GE I RnD DELHI
2025_MES_745121_1
GE/RND/T-84/DLI/2025-2026
Open Tender
Civil Works
240 days
Delhi
Class-D, Cat- a (i), b(i)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
₹82,000
21 Mar 2026
18 Dec 2025
19 Jan 2026
18 Dec 2025
16 Jan 2026
2 Jan 2026
Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.Note: Rate also includes for necessary scaffolding/Jhoola work to carry out work upto a hight G+7 floor.
M&L rendering 15 mm thick in CM (1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed. Note:- (i) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor
M & L Preparation of newly plastered surfaces of walls and apply two coats of oil bound distemper over a coat of alkaliresistant primer including 2mm wall putty all as spd and directed.
M & L Preparation of newly plastered surfaces of ceiling and apply two coats of oil bound distemper over a coat of alkali primer including 2mm wall putty all as spd and directed.
M&L for applying one coat of oil bound distemper on walls including preparation of old decorated surfaces including filling minor holes with wall care putty and including brooming down or steel wire brushing, scrabing down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots complete all as specified and as directed
Complete removal of existing treatment from internal / external plastered or unplastered surfaces of walls complete all as specified and directed
M&L for 2mm thick layer(Each coat min 1mm thick) of white putty on scrapped/uneven surfaces of any description to match with the existing surfaces before application of white wash/distemper/cement base paint/Apex paint etc complete all as spd and directed Make : JK Wall care putty/Birla white putty or equvalent
M&L for applying two coat of oil bound distemper on walls after completion of putty work (if required on site) and including preparation of surfaces and including brooming down or steel wire brushing, scrabing down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots complete all as specified and as directed Note : Putty work shall be paid separtely in relivent items.
Description all as per item here-in-before but on ceiling
M&L for applying one coat of synthetic enamel paint over old painted wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint over old painted steel surfaces of any descripition over 10cm width or girth including preparation of old surfaces complete all as spd and as directed
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L brick work with sub class B old size bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed.
M&L rendering 15 mm thick in CM (1:4) on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for broken glass coping on top of wall with CM 1:3 including taking and removing old unusable glasses complete all as specified and directed.
M&L for applying two coats of 100% Premium acrylic emulsion paint with rooler/spray having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including water based priming coat of exterior primer applied @ 0.90 litre/ 10sqm over surface complete all as specified and directed. Make : Asian paints (apex ultima)/Berger (weather coat all ground)/Nerolac (excel total) Note:- (i) The application will be done by the specialist agency. MOU will be submitted by the contractor with the OEM. (ii) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality A complete all as specified and directed.
S&F Mild steel bands, straps, supports or stay, for rain water, ventilating pipes including bolts if reqd, hooks (stay) heavy for large gates hook and pintle large hasps and staple, chains hand made sliding bolts clamps, hold fasts wall ties etc etc hooks for hanging fans plain angle cleats for securing purlins to wood truss or rafter, knee piece inserts, two way and three way straps, plate washer and similar small articles confirming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
Dismantling Asbestos corrugated & Semicorrugated etc sheetin in roof covering of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed at site complete all as specified and directed.
M&L for grinding polished the terrazo tile/kota stone flooring/marble stone flooring and wall complete including wax polished all as spd. Note standard size machine shall be used for griding floor and hand grinding machine be used for vertical surface ie dado/skirting etc complete all as specified and as directed.
Material & Labour for 15mm thick rendering on roof surfaces in cement mortar (1 : 4) using with WPC finishes the surface even and smooth without using extra cement complete all as specified and directed. Note :- Water proofing compound shall be paid separately
Taking out for repairing of rolling shutter push type with necessary repair work of defective parts i.e, re posting of laths, riveting to old defective rivets, tightning nuts and bolts, replacement of spring, greasing to movable parts and at guide channel, greasing the sides of the rolling shutter and re-fixing rolling shutter for smooth functioning size of rolling shutter not exceeding 25 Sqm each complete all as specified and directed.Note : Rate includes the replacement of broken spring complete all as specified and directed.
S&F 1.25mm lathe thickness Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
S&F Ball bearing for rolling shutters complete all as specified and directed.
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
M&L preparation of new steel & iron surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of primer complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar
M&L for rubber moulded prepolished coloured precast concrete interlocking paver block 60mm thick of any shape and size with white cement and pigment confirming to IS 15658-2006 M-35 Grade, complete all as specified and directed.
M&L Sand filling/stone dust under floors or in foundations including watering and consolidation spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed.
Rounding to edges of stone slabs one edge such as steps cooking platform and other similar situations complete all as specified and as directed.
Cleaning and removing all scale and dust from tanks of capacity 500 litres-2000Ltr and from mouth of circulating pipe etc including disconnecting water pipes, tanks if necessary and refixing the same after necessary cleaning and writing letters "TANKS CLEANED ON" and date in "DDMMYYYY" format in any tint, as per requirement not exceeding 7.5cm in height letters using synthetic enamel paint complete all as specified and directed.
S&F In repair 20 mm dia Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
S&F In repair 25 mm dia Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. complete all as specified and directed.
S&F In repair 32 mm dia Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. complete all as specified and directed.
S&Fin repairs (SINTEX) over head water tank cover for tank capacity 500,750&1000 litr with fixing bracket and screw complete all as specified and directed.
S&F in repairs (SINTEX) over head water tank cover for tank capacity 2000 litr with fixing bracket and screw complete all as specified and directed.
Running welding in repairs thickness of metal to be welded exc 6mm n.exc 9mm complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame)n.exc 1.5sqm and making good to distrubed surface without any extra cost complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame)exc 1.5sqm but n.exc 4 Sqm and making good to distrubed surface without any extra cost complete all as specified and directed.
Taking down Shutters of any description exc 1 sq. m n.exc 2sqm each and refixing in the same opening after repair work complete all as specified and directed.
S&F repairs Powder Coated(minimum thickness of powder coating 50 micron) aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F repairs Powder Coated(minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.
S&F repairs Powder Coated(minimum thickness of powder coating 50 micron)aluminium window and ventilator shutters(wire mesh shutter and glaze shutter), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F Aluminium powder coated decogrill make DG 104(10mm thick section) with frame of section not less than 0.136kg/Rm with F channel
S&F in repair 4 mm thick sheet glass in squares/rectangle not exc 0.50 sqm in each pane fixed with wooden beads or putty (in metal/wooden frames etc)including hacking out old glasses complete all as specified and directed.
S&F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple etc in wooden/steel frames complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L 15mm thick Screed bed or bedding layer of cement mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L prepolished coloured chequred cement concrete tiles 300X300X25 mm size set in screed bed 20 mm thick in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings etc not exc 15 cm thick above or below ground level complete all as specified and directed.
M/L Cement concrete type C2 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete/Subbase complete all as specified and directed.
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection,subbase etc complete all as specified and directed.
S&F LED Post Top Lantern 40 watt luminaire with diffuser and painted spun aluminium deflector replacement of standing pole up to 3 mtr 32 mm dia or as per site requirement ncluding taking down old unserviceable complete all as specifed and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and labour for pre-cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs,manhole cover and similar work including necessary form work complete all as specified and directed.
S & F Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete as directed and specified.
Supply and fix mild steel round bars 10mm dia FE 410W Gde E-250 quality A or Fe 290 gde E-165 cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips for man hole cover handle complete all as specified and directed.
Dismantling wall/ceiling boarding, any description, fixed in any position with nails/screws/grid including taking down E/M fittings/fixtures on ceiling and refixing the same after completion of work to make it functional complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling 605x605mm grid size complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for 8mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed.
Taking down old tarfelt water proofing treatment on roof surfaces and removed from site complete all as spd and directed.
S&F in repairs Welded steel wire fabric supplied and fixed complete to wood or steel members weight n.exc 4kg per sqm Note : Rate also includes for necessaryscaffolding /Jhoola work to carry out work upto a hight G+7 floor complete all as specified and directed.
M & L for preparation of surfaces for applying bituminous primer (conforming to IS-3384-1965) @ 0.30 Kg/Sqm complete all as specified and directed.
M & L 3mm thick APP based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.Note: Application of APP membrane must be done by authorised applicator of membrane manufacturer co
M&L for applying two coats of bitumen based aluminium painting on water proofing treatment with preparation of surface as on non assesible area complete all as specified and directed.
S&F (Ornamental gate) Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-1657 including portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.ornamental and intricate design complete all as specified and directed.
mplete all as specified and directed.
M&L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. (Paymentfor providing grooves shall be made separately).
M&L for 10mm thick cement plaster on brick wall concrete wall surface in CM 1:4 finished even and smooth surface without using extra cement mixing with liquid WPC complete all as specified and directed. Note :-(i) Water proofing compound shall be paid separately (ii) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Removing building materials etc.to a distance of upto 20 km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
M&L galvanised, iron pipe of dia 32 mm with all fitting laid in trenches complete all as specified and directd
M&L for earth continuity conductor 4.00 mm dia passing through & including Conduit/pipe any of size main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as requireddia galvanised iron wire complete all as specified and directed.
M&L for 5mm thick cement plaster on brick/concrete ceiling surface in CM 1:3 finished even and smooth surface without using extra cement mixing with liquid WPC complete all as specified. Note :-(i) Water proofing compound shall be paid separately (ii) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a hight G+7 floor.
M&L for earth continuity conductor GI stripe 25x4 mm passing through & including PVC Conduit of any size main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required dia galvanised iron strip complete all as specified and directed.
16 Sqmm 4 Core
25 sqmm 4 Core
35 Sqmm 3.5 Core
10 Sqmm 2 Core
6 sqmm 3 core
M&L galvanised, iron pipe of dia 25 mm with all fitting; laid in trenches complete all as specified and directd
Supply and erection Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 09 Mtr long. Poles shall be painted with two coats of black bituminous paint throughout internally, and externally up to the planting depth. The remaining portion of the exterior shall be painted with one coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for protection of cable duct including for taking out and relaying of LT Cables complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and directed.
M&L for sub class 'B' burnt brick flat across the cable, for protection of cable laid in trenches complete all as specified and directed
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and directed. Note - Punned thickness shall be measured.
Supply and laying in trenches, fixed to wall / pole/ tray etc UG cable XLPE insulated armoured heavy duty electric UG cable with aluminium conductor 1100 volts grade of cross sectional area of following size including taking down old unseriveable cable complete all as specified and directed.
Supply and laying in replacement of old unserviceable GI pipe medium grade of 50mm dia including GI fittings laid in trenches for protection of UG cable complete all as specified and directed.
M&L for GI fitting / Galvanised Nipple dia 32mm x 225 mm for street light complete all as specified and directed
Excavation in trenches,hard dense soil/,black top bitumin /PCC n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft soil/hard soil/bituman surface complete all as specified and directed
All as per item No.88.00 above but 40 mm dia.
Supply and fix in replacement of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with microprosessor release based,100% ICS=100% ICU, 36 KA complete all as specifed and directed.
All as per item Ser No 92.00 above but of capacity 250Amps.
M&L for boring of holes under road , pavement , hard standing by trenches techonology using ultra sound technology/ mannualy mechanically and necessary machine for 100 mm dia GI pipe complete all as specifed and directed.
M&L for GI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length incl mild steel flat iron Clamps with nut bolts etc complete for fixing of street light including taking out old unserviceable GI brackets complete all as specified and directed.
S&F Junction box SMC KIOSK box water proof IP-67 of size 225x29x122 mm including fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole making hole on pole as per site complete all as specified and directed.
S&F in replacement of Junction box SMC KIOSK box water proof IP -67 of size 140x140x95 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specifed and directed.
S&F in replacement of Junction box SMC KIOSK box water proof IP-67 of size 300x200x125 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specifed and directed.
M&L for Copper conductor cable 2.5 Sqmm 3 core PVC sheathed multi core for connection of street light fittings inserting from top in side the pole and connecting in junction box complete including making Hole in Pole as per Site, complete all as specified and directed
S&F in replacement service cable 1100 volts grade heavy duty PVC insulated copper multistranded conductor served with inner sheathing of size 1.5 Sqmm 3 Core complete including taking down of old burnt cable complete all as specified and directed.
All as per item Ser No 92.00 above but of capacity 200Amps.
Supply and fix in replacement of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with thermal magnetic release based,100% ICS=100% ICU, 25KA complete all as specifed and directed.
S&F in replacement Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 45 Watt including taking down old unserviceable complete all as specifed and directed.
S&F in replacement of driver for 45 W LED street light fitting complete all as specifed and directed.
S&F in replacement of driver for up to 100W LED street light fitting complete all as specifed and directed.
All as per item No 103.00 abov of but capacity of led street light led 120 Watt
All as per item No 103.00 above but capacity of led street light capacity 150 Watt
S&F in replacement of LED flood light with pressure die cast aluminium housing 100 Watt Orion 3.0 Series completed with connection including taking down old unserviceable complete all as specifed and directed.
S&F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light,suitable for highlighting architectural facade and general purpose lighting of capacity LED 120 Watt completed with connection including taking down old unserviceable complete all as specified and directed.
S&F in replacement of LED flood light with pressure die cast aluminium housing 200 Watt Orion 3.0 Series completed with connection including taking down old unserviceable complete all as specifed and directed.
S&F in replacement of LED flood light with pressure die cast aluminium housing 150 Watt Orion 3.0 Series completed with connection including taking down old unserviceable complete all as specifed and directed.
S&F in replacement of driver for 150W LED street light fitting complete all as specifed and directed.
S&F in replacement Timer switch Astronomical type ,415 Volt three Phase of 63 Amps rating with Three Pole ML-4 contactor incl one Toggle switch for Auto, off and Manual function and incomming MCB TP internally pre wired and Fitted inside steel enclosure complete all as specified and directed
M & L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole and filling in road cuts/ hard standing complete all as specified and directed
M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate for base of foundation of pole complete all as specified and directed.
M & L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for foundation of pole around pole complete all as specified and directed.
M & L for applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces complete all as specified and directed (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat will be paid seperately.)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
TDR.pdf
Tender Documents • 1.56 MB
BOQ_834343.xls
BOQ • 1.06 MB
Download all tender documents and submit your bid