Executive Engineer (Electrical)
University of Calicut
Electrification of Basket Ball Court in the University Campus
2023_UoC_603885_1
D3/E-Tender No.25/2023-24
Open Tender
Electrical Works
Item Rate
90 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,487
₹15,650
12 Feb 2024
19 Sept 2023
29 Sept 2023
19 Sept 2023
26 Sept 2023
19 Sept 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A. (1.10.1)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. (1.33)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. (1.14.1)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm. (1.17.3)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. (2.10.1)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps. (2.13.2)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps. (2.15.3)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. (5.17)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm. (7.5.1)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (2.11)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. (2.13.1)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. (2.15.2)
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. (14.1)
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. (14.7)
Supply & Laying of DWC pipe in Hard Soil 0.7 m below ground level including excavation. 50/38 mm or nearest size. (od26543/2023_ 2024)
Supplying and fixing Copper tubular earth socket for 3.14 mm (10 SWG) conductor. (od26544/2023_2024)
Supplying 6 sq mm 2 core PVC/ XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conformings IS 1584/ part /1988 for PVC IS 7098/part I for XLPE. (od26546/2023_2024)
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50 /38 mm or nearest size. (90.12.10.2)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43). (90.11.1.10)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG ). (90.16.1.3)
Supplying and installing integrated, Beam Angle, 90 (angle specification type) Lighting Color, Pure White. Body Material, Aluminum Die Casting 350 W LED Flood light with above IP 66 protection (approved makes mandatory) suitable for Sports purpose, all fittings including connection cables etc. with all accessories to fix in the street light pole. (od24771/2023_2024)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.4 core 35 sq mm with factory made clamp. (90.12.7.43)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 35 sq mm. (90.12.5.43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43). (90.11.1.18)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required .2 X 6 sq. mm (19mm). (9.1.1)
Supply & laying of DWC pipe in the existing pit for UG cables 50/38 mm or nearest size. (od29545/2023_2024)
Supplying and installing integrated 70-80W LED Street light with IP66 protection (PWD approved makes mandatory) With fittings , all accessories and 3 meter 380/0.20 3core sheathed round cable to fix in the Walls of Buildings. (od31086/2023_2024)
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters. (90.15.1.1)
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (Dimension of pit shall be minimum of 2.5m*0.6m*0.6m). (od31601/ 2023_2024)
HELVUS ENGINEERING
ASIF ELECTRICAL WORKS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_899381.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .