Loading…
Loading…
Tender ID
Tender Value
₹1.4 L
EMD Value
₹3,580
Closing Date
16 Mar 2026, 12:00 pmClosed
Assistant Engineer
Assistant Engineer koothattukulam municipality
GENERAL-Koothattukulam-MLA-SDF Minimast at Devamatha Jn.-MLA-SDF-SITC of Minimast at Devamatha Jn. under Koothattukulam Municipality.-General Electrical Work
2025_LSGD_776862_5
E2/KKLM/AE/25-26/MLA-SDF Minimast at Devamatha Jn.
Open Tender
Electrical Works
Item Rate
7 days
koothattukulam
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹3,580
Yes
7 Mar 2026
7 Mar 2026
18 Mar 2026
7 Mar 2026
16 Mar 2026
7 Mar 2026
SITC of MINImast
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD531777/2024-2025:Supply and provide 20 mm corrigated flexible PVC conduit
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD531783/2024-2025:Supply and provide DIN rail suitable to fix MCB, Isolator, RCCB, etc including suitablesize nut and bolt.
15.4.1:Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required1 output per phase and suitable for single phase supply
OD531786/2024-2025:Supply and fixing 25A AC 1 MNX 9 -2 pole power contactor ( L7T ) conforming to IS/ IEC 60947-4-1 & IEC 60947-4-1 in the existing enclosure and giving connection etc as required
OD531785/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.-32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
OD531784/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.-32 A fuse unit with fuse link
OD531778/2024-2025:Supply and installation of Hot press moulded SMC single phase meter box of size 350x250x150mm- sintex make GS-MB-3425 or equivalent
OD531779/2024-2025:Supply and drawing 2 core 6 sq. mm PVC insulated and PVC sheathed Alumnium weather proof cable between the poles and giving connections make in good working conditions. including tag with the supporting wire
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD531782/2024-2025:Supply and providing aluminium board of size 60mmx30mmx3mm size with paintings of name of local body, location etc. fitted to the minimast/highmasts using clamps
OD531780/2024-2025:Supply and fitting SMC junction box (hinged door) in the top of the minimast 170mmx170mmx105mm size category GSMB1414 or equivalent
90.3.17.1:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewnit.pdf
Tender Documents • 0.02 MB
BOQ_1426771.xls
BOQ • 0.32 MB
viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .