| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAdmitted-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Admitted-Finance | |
| 2 | L2₹29.5 L+₹7.7 L (35.2%)Admitted-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Admitted-Finance | |
| 3 | L3₹31.8 L+₹10.0 L (45.7%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹35.0 L+₹13.2 L (60.3%)Admitted-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Raman Electric Trading Co L2 | SANJEEV ENTERPRISES L4 | Saurav Enterprises L1 | Gopal Enterprises L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material & Labour for Servicing and Cleaning of On grid inverter outdoor type, IP-65 protection, 60 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, including making fresh connection as per existing complete all as per site requirment complete all as specified & directed.
Make: ABB Model : Solar inverter Trio-TM-60.0-480. | 17 | Each Job | 7,500 ₹1,27,500 | 5,200 ₹88,400 | 2,500 ₹42,500 Lowest | 7,000 ₹1,19,000 |
| 2.00 | Supply and fix in replacement of communication card suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 5 | Each | 11,000 ₹55,000 | 14,200 ₹71,000 | 8,500 ₹42,500 Lowest | 12,000 ₹60,000 |
| 3.00 | Supply and fix in replacement of Digital Signal Processor (D.S.P.) Board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 5 | Each | 15,000 ₹75,000 | 21,000 ₹1,05,000 | 12,000 ₹60,000 Lowest | 16,000 ₹80,000 |
| 4.00 | Supply and fix in replacement of Surge Board (MOB) board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 4 | Each | 10,000 ₹40,000 | 14,400 ₹57,600 | 8,500 ₹34,000 Lowest | 12,000 ₹48,000 |
| 5.00 | Supply and fix in replacement of AC filter board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 4 | Each | 27,000 ₹1,08,000 | 31,200 ₹1,24,800 | 14,000 ₹56,000 Lowest | 26,000 ₹1,04,000 |
| 6.00 | Supply and fix in replacement of power supply board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 4 | Each | 20,000 ₹80,000 | 22,900 ₹91,600 | 14,000 ₹56,000 Lowest | 22,000 ₹88,000 |
| 7.00 | Supply and fix in replacement of exhaust fan suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 12 | Each | 5,500 ₹66,000 | 8,100 ₹97,200 | 4,500 ₹54,000 Lowest | 6,000 ₹72,000 |
| 8.00 | Supply and fix in replacement of String connecter MC4 Male suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 25 | Each | 150 ₹3,750 Lowest | 180 ₹4,500 | 150 ₹3,750 Lowest | 200 ₹5,000 |
| 9.00 | Supply and fix in replacement of String connecter MC4 female suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed. | 25 | Each | 160 ₹4,000 | 190 ₹4,750 | 150 ₹3,750 Lowest | 200 ₹5,000 |
| 10.00 | Supply and fix in replacement of solar photo voltaic modules panel 335watt, rated voltage 36.4 V, rated current 8.94 Amp, crystalline silicon PV modules with spare/parts required for smooth functioning, tightenining of electric connection complete and assembling and reconnecting all as per site requirment complete all as specified & directed. | 8 | Each | 8,000 ₹64,000 | 8,800 ₹70,400 | 8,000 ₹64,000 | 7,000 ₹56,000 Lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
18 Oct 2025, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
COMPREHENSIVE MAINT OF SOLAR PHOTOVOLTAIC POWER PLANT ROOF TOP SYSTEMS AND OTHER ALLIED WORK UNDER GE UTILITY AMBALA
2025_MES_726612_2
CA NO GE U AMB 50 OF 2025-26
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹72,000
24 Oct 2025
25 Sept 2025
20 Oct 2025
25 Sept 2025
18 Oct 2025
4 Oct 2025
25 Sept 2025 - 29 Sept 2025
Amount
Material & Labour for Servicing and Cleaning of On grid inverter outdoor type, IP-65 protection, 60 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, including making fresh connection as per existing complete all as per site requirment complete all as specified & directed. Make: ABB Model : Solar inverter Trio-TM-60.0-480.
Supply and fix in replacement of communication card suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of Digital Signal Processor (D.S.P.) Board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of Surge Board (MOB) board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of AC filter board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of power supply board suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of exhaust fan suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of String connecter MC4 Male suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of String connecter MC4 female suitable for inverter of make ABB, Modal no DCWB-SX2-TRIO-TM-60.0-480 at 1 MW solar plant complete as per site requirement or as per sample all as specified and directed.
Supply and fix in replacement of solar photo voltaic modules panel 335watt, rated voltage 36.4 V, rated current 8.94 Amp, crystalline silicon PV modules with spare/parts required for smooth functioning, tightenining of electric connection complete and assembling and reconnecting all as per site requirment complete all as specified & directed.
Material & labour in replacement D-Link type , 75 deg C (UL), 6 UTP LAN cable drawn in conduit/ flexible pipe fixed on wall on batten or recess or chases or buired in ground or any other indicated suituation etc, as required with proper saddles / spacer, screw etc, complete all as specified and directed.
Material & labour in replacement of flexible electric cable hose pipe of dia 50 mm (2") fixed on solar structure for drawing of various type and size of wire complete all as specified and directed.
Material & labour in replacement of flexible pvc Zip cable tie of size 300 mmx 4.8 mm long to tie cable/wires complete all as specified and directed.
Supply and fixing in replacement of PVC insulated cable of size 1.5 Sqmm, 16 Core multi stranded coper cable complete all as specified & directed.
Supply and fixing in replacement of PVC insulated Solar DC cable 6 sqmm 1.8 KV DC volt for solar plant copper cable complete all as specified & directed.
Supply and fixing in replacement of PVC insulated Solar DC cable 4 sqmm 1.8 KV DC volt for solar plant copper cable complete all as specified & directed.
Supply and fixing in replacement of PVC Airtight connector with two hole gasket for signal cable glands PG 21+ Cap for ethernet cable connection for solar inverter complete all as specified & directed.
Servicing to LT panels/Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc complete all as specified and as directed. Note:- Unserviceable parts replaced if any shall be measured & paid seperately under respective items.
Material & labour for Repairing broken Door, Locking Arrangements, Hinges, etc. of LT Panel/ Feeder Pillar/ Pole Box, Indoor/ Outdoor type of any size, necessary welding, drilling as reqiured, Replacing Door, Locking Arrangements, Hinges, etc. if ordered, complete all as specified and as directed.
Material & labour for Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching with the existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc complete all as specified and as directed.
Rewiring the LT cubical type panel by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,. etc after taking out the old unserviceable wiring complete all as specified and as directed.
Supply & fixing in replacement of LED indication Lamps for R,Y,B Phase in existing LT Panels complete all as specified and directed.
Supply & fixing in replacement of 3 ph, Digital type Volt meter in existing LT Panels complete all as specified and directed.
Supply & fixing in replacement 3 ph, Digital type Ammemeter existing LT Panels complete all as specified and directed.
Supply only Indoor resin cast ring type low tension current transformer 400/5A , 15VA burden accuracy class 1 confirming to IS 2705 /1992
Supply only Indoor resin cast ring type low tension current transformer 1600/5A, 15VA burden accuracy class 1 confirming to IS 2705 /1992
Supply and fix in replacement MCCB of capacity 400 A , 415 Volts 4 pole with bracking capacity 50 KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric connection including necessary connected fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model complete all as specifed and as directed.
All as per item No 28 above but of size 100 A 415 Volts 4 pole with breacking capacity 16 KA.
All as per item No 28 above but of size 100 A 415 Volts 4 pole with breacking capacity 25 KA.
Taking down old unsv earthing of any type and size but Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised wire 4 mm dia (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth wore by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2Ώ the earthing will be redone at no extra cost.
All as per item No 31 but using galvanised iron strip 25×4 mm as earthing lead.
All as per item No 31 but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead.
Taking down unsv earth continuity conductor of any type and size but Supply and fix in replacement Earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to pole or any other indicated suituation for loop earthing etc, as required for galvanised iron wire 4 mm dia with proper saddles / spacer, screw etc, complete all as specifed and as directed.
All as per Ser item No 34.00 here in before but 25×4 mm galvanised iron strip .
All as per Ser item No 34.00 here in before but 20x3 mm copper strip
Supply & fixing in replacement of any size of unsv cable with copper cable pvc insulated of size 10 Sqmm single core including connections etc complete with suitable size of lugs, nut, bolt and weasher etc as speified and directed.
Dismantling concrete pole / steel pole / struts of any size but Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts nut and screws as specified type 410 SP-55 (11.0 meters long) including two coats of aluminium paint over a coat of red oxide primer all as specified and as directed. Note : Necessary earth work excavation, removal of surplus soil & concrete shall be measured and paid separately in respective items.
Taking down Lightening arrester of any type and size and refixing the same after cleaning on 11 mtr pole including making provision for fixing, nut and bolts etc complete all as specified and directed.
Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning complete all as specifed and directed. Note : GI Funnel, brazing, mixture of salt/char coal/MGSO4 shall be measured and paid separately under relevant items.
Taking downn unsv funnel of any type and size but Supply and fix in repair GI funnels for earthing complete all as specified and directed.
Taking down unsv chamber of any type and size but Material and labour for earthing chamber of size 0.45 x 0.45x 0.45 m and 150 mm thick by PCC 1:3:6 type C1 with 20 mm graded stone chamber with RCC 1:2:4 type B1 in cover slab complete all as specified and directed.
Taking down unsv chamber cover of any type and size but Material and labour for earthing chamber cover of size 0.45 x 0.45x .04 m with RCC 1:2:4 type B1 with 20 mm graded stone complete all as specified and directed.
Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mm of 450 mm long to be fixed to ground by means and including neceaary cement concrete and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete, writing earth reading and connected items like palnting of panel etc, and necessary excavation and earth work including taking down old complete all as specified and directed.
Material and labour for Testing of earth resistance value from earthing pit test terminal point and write in/ on existing identification board complete all as specified and directed. Note:- (i) The contractor has to provide his own testing kit and all connected items for Earth resistance checking in presence of Engr-in-charge complete. (ii) Earth testing will be carried out on quarterly basis and the register will be maintained for earthing resistance result by the contractor for entire period of contract duly signed by the contractor and Engr-in-charge and same will be handed over to the Engr-in-charge on completion of contract.
Taking down old/ unsv test point of any type and size but Supply and fix in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Supply only of common salt commercial all as directed complete all as specified and as directed.
Supply only of charcoal dust complete all as specified and as directed.
Taking down unsv any type and size of GI tubing but Supply and fix in repair for 50 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches complete complete all as specified and directed.
All as per item No 49 but of size 25 mm bore.
All as per item No 49 but of size 15 mm bore.
Taking down unsv any type and size of GI tubing but Supply and fix in repair for 50 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed.
All as per item No 52 but of size 25 mm bore.
All as per item No 52 but of size 15 mm bore.
Supply and fix in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of size 50 mm bore including taking down the unserviceable existing complete all as specified and directed.
All as per item no 55 above but of size 25 mm bore.
Material and labour for repair and servicing to 1 phase 415V, 0.75 HP, centrifugal monblock pump of any type and make by dismantling the pump set , cleaning, varnishing, heating and drying and reassembling the same, testing, including replacement of nuts , bolts and washers, bearings of suitable size all as directed.
Repair / service / overhauling of gang operating devices 11000 Volts upto 400 Amps including greasing all the moving parts and applying white petroleum jelly at the contact points, tightening all nuts and bolts and prividing PG clamps 06 Nos, additional nut and bolts commissioning and testing complete including dismantling and replacing all the unserviceable parts / spares all as specified and as directed. Note: All the spares replaced shall be measured and paid separately Item No - 59 to 64
Supply only moving contact blades
Supply only fixed contact jaw copper
Supply only copper braded tape (Thinner copper flexible jumper)
Supply only mild steel supporter
Supply only back connected plate
Supply only jumper carrier
Labour only for dismantling transformer step down out door type 11KV/433 Volts of capacity 1250 KVA by disconnecting incomig /outgoing cables and ACSR jumpers, opening top end of thed unit by unscewing nuts/bolts washers all as directed for replacement of unsv parts and reassembling including reconnections of incomers and out going connections (work includes replacement of gasket seal,draining out/refilling of transformers oil, rusted /unsv nuts bolts with washers and general cleaning of transformers inner chamber by removing accumulated sludge etc at bottom before refixing and rates quoted will be deemed to includes for the same works. Notes:- The transformer repair works shall be carried out only by engaging specialised and experienced technicians. The oil shall be filtered before refilling if found required. The charge for filteration will be measured and paid separately.
Supply and replace defective LT porcelain bushings complete of transformer step down out door type 11KV/433 Volts of capacity 1250 KVA any make/ size/ type all as specified and directed .
Supply and replace defective HT porcelain bushings complete of transformer step down out door type 11KV/433 Volts of capacity 1250 KVA any make/ size/ type all as specified and directed .
Supply and replace defective LT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc complete of transformer step down out door type 11KV/433 Volts of capacity 1250 KVA any make/ size/ type all as specified and directed.
Supply and replace defective HT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc complete of transformer step down out door type 11KV/433 Volts of capacity 1250 KVA any make/ size/ type all as specified and directed.
Testing of di-electric strength i.e BDV test for 60 Sec with stand the transformer oil of any capacity to authorised value 45 to 60 KV using standard oil test kit as per result as IS 335-1972 complete all as specified and directed. Note :- a) The rate quoted shall be deemed to include for arrangement of standard testing kit . (b) The dielectric strength value of the transformer oil shall be tested before filtration. (c) Sample of oil to be collected and testing to be done transformer site. (d) Testing to be done with gap seting - 2.5 mm , tempreture setting on ambient and frequency with 50 cycle (e) Test reports shall be enclosed at the time of payment.
Filtration of transformer oil of transformers installed at various locations to achieve di-electric strength not less than 60 KV for 1 minute at 2.5 mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and directed. Note :- a) The rate quoted shall be deemed to include for taking necessary conections to filteration plant from transformer and switch gear oil duly removing the inlet and out let connections. (b) Electric supply for the filteration plant will be made available free of cost. (c) The dielectric strength value of the transformer oil shall be tested affter filtration as specified and directed. (d) Test reports shall be enclosed at the time of payment.
Supply and topping up or replacement of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transforme etc at various locations complete all as specified and directed.
Material and labour for replacement of silica gel breather assembly for HT distribution transformers of 100 KVA to 315 KVA capacity including dismantling old complete all as specified and directed.
Material and labour for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 95 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed.
Dismantling of HT VCB panel after disconnecting HT supply and installed after repairing and servicing of HT panel and breaker, removing moisture and dust from HT bus bar and from inside of HT panel of 66 KV/11 KV substations complete all as specified and directed. Note: (i) Measurment of (IR) resistance value, necessary tools, labour and petroleum jelly for servicing of VCBs are included in the quoted rates. (ii) Parts will be replaced under relevent items.
Rectification of complaints of Roof top solar plant by cleaning and servicing of Inverter and connected items also solar panel with water and scrubber having long handle one day every week and keep the Roof top solar plant always in serviceable condition as directed by Engr-in-charge. Contractor must maintain a register to record of cleaning of panels duly signed by the contractor rep of user , JE E/M and Engr-in-charge. Note:- A planty @ Rs. 2000 per cleaning will be levied to the contractor for not cleaning the panel solar panel and connected items and maintain the register as explained above or as decided by Engr-in-charge/GE.
Supply and Fixing mild steel galvanised chain link fencing size 100mm x 100mm (3.80mm thick dia wire) including line wires and any type of standards, rails, straining bolts etc., including provision of binding wire and complete all as specified and directed.
Material & labour for XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored , electric power cable (Heavy duty ) with aluminum conductor 11000 volts grade cross sectional area 95 sqmm 3 core suitable for 11 KV earthed system incl taking down old unsv HT cable complete all as specified and directed.
Supply and fixing angle iron made of mild steel confiriming to Fe 410 - W (Gde-E 250) of size 50x50x6 mm as in post and sturds in fencing incl cutting top to shape as directed,and flat iron of size 40x6 mm drilling of holes as drected for chain link fencing to angle all as per directed rate including dismanting to the old PCC fence post complete all as specified and directed. Note - (i) Rates are including required Nut bolts with washers any type any sizes for fixing of chain lik fencing. (ii) PCC for post of picket shall be paid separatelly in respective items.
Supply and fixing in replacement Mild steel round bar 10 mm dia and over conforming Fe410 - A for fixing to chain link fencing complete all as specified and directed.
Material and labour for painting with two coat of synthetic enemelled paints over a coat of red oxide including perparation of new steel surface and chain link fencing complete all as specified and directed. Note - Colour of paint will be approved by Engineer in Charge.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed. Note:- (i) Additional stone aggregate required shall be measured and paid separately under relevant items of this schedule. (ii) The rate also deemed to be included for labour (iii) All the sub station yards shall be kept clean through out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. (iv)The rates shall be deemed to includes clean the cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less than 50 M and keeping the excavated surface clean and levelled all as directed.
Supply and spray chemical (Round up) for every two months after date of handing over site for remove unwanted vegitation / grass at solar power plant , approx 08 bottles required for one time for complete solar plant area complete all as specified and directed.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet with vitreous enamelled with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT, 25 x 20cm complete all as specified and directed.
Material and labour for defect rectification in HT/LT 11 KV/0.415 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault locating equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed. Notes for Srl. Item No.85 : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 24 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of “Each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch, irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundations / filling around the post complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified and directed.
Dismantling of unserviceable cross arm such as MS channel /angle section etc complete all as specified and directed.
Material and labour for cross arms, bracings, supports, clamps and back plates, fabricated from structural steel including nuts, blots, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed.
Refilling, Servicing and pressure Testing of ABC type Fire extinguisher of 04 Kg Capacity.
Refilling, Servicing and pressure Testing of CO2 type Fire extinguisher of 04 Kg Capacity.
Material & labour for cement concrete in foundations, filling and mass concrete (PCC) in CM of (1:2:4) with type B2 using 40mm graded stone aggregate for pole coping above ground level complete all as specified and directed.
Supply & fix in replacement of fire hook confirming to IS 927- 1981, hook head is made up of forged carbon steel duly painted with anti-corrosive paint, handle shall made of bamboo of length not less then 3 mtr, hook should marked with ISI marked complete all as specified and directed.
Supply & fix in replacement of fire beater to confirming to IS 8096-1992 ,beater blade is made out of steel wire mesh of size 452 x 352 mm. with fire resistant frame and handle is made out of solid bamboo of length 1.8 mtr, dia 30+ 5 mm complete all as specified and directed.
Material & labour in replacement fire mild steel fire bucket confirming to IS 2546-1974, body made out of minimum 1 mm. Thickness, of capacity min 10 ltr and bucket is duly painted and marked as per fire standard complete all as specified and directed.
Material & labour for fabricating outdoor fire bucket stand made out off 50mm x 50mm x 6mm angle iron and MS sheet top roof made out of mimimum 3mm thickness for hanging 04 Nos of fire bucket and extingusher with proper foundation and placing the stand whenever specified by engineer -in-charge. including necessary welding ,cutting etc.and painting with post box red color comlete all as specified and directed.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100/11000 volts including connecting and testing for any size complete all as specified and directed. Note:- Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately.
Supply and laying, connecting, testing in replacement of XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall incl aluminium thimbles/lugs etc complate all as specified & directed. Note: (i) Earth work, sand, bricks removing, returning filling will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per item ser No 98 here in before but for 25 Sqmm 3.5 core complete all as specified and directed
All as per item ser No 98 here in before but for 35 Sqmm 3.5 core complete all as specified and directed
All as per item ser No 98 here in before but for 150 Sqmm 4 core complete all as specified and directed
All as per item ser No 98 here in before but for 630 Sqmm single core complete all as specified and directed
Material & Labour for surface cleaning of LT steel tubular poles 9 mtrs long including removing rusted particles painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified & directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement / PCC
Material & Labour for prepering old painted steel suraces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as speciied and directed.
Supply & filling for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading lime stone powder under stones complete all as specified and directed.
Material & Labour in replacement of GI nuts, bolts, washers of sizes 8x40 mm or any size as required at site complete all as specified and directed.
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash complete all as specified and directed.
Material & Labour for Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleanese etc complete all as specified and directed.
Supply, installing, testing & commissioning in replacement of outdoor type cubical panel board of size, outer shell made out of 3.0 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 40x40x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl aluminium bus bar of 150 A of 3 phases and 100 amp of neutral bar , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 65 KA comprising of the following :- (a) MCCB 100 Amps, 4 pole 415 Volts AC , 25 KA - 01 No (Incoming) (b) MCCB 40 Amp, 4 pole 415 Volts AC , 25 KA - 01 No (Outgoing) (c) Switch socket 15/5 Amp with enclouser with wiring -01 set (d) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (e) Digital Multifuction meter suitable to monitor Voltage, Amp, Frequency, kWh with suitable size of CTs -01 Set (f) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates.
Supply, installing, testing & commissioning in replacement of outdoor type cubical panel board of suitable size , outer shell made out of 3.0 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm grouted with PCC 1:2:4 type B-1 , frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 2 places with body and hinges should be welded with body and door) with locking arrangements and outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar , 3 ph (RYB) of 300 A and 1 Ph (neutral) of 150 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 65 KA comprising of the following :- (a) MCCB 100 Amps, Amps 4 pole 415 Volts AC , 10 KA. - 01 No (Incoming) (b) MCB TPN 32 Amp, 415 volt, 4 pole (Outgoing)-02 Nos. (c) Onload change over switch front operated 200 amp, 4 P, 415 Volt-01 Nos (d) Digital Multifuction meter suitable to monitor Voltage, Amp, Frequency, kWh with suitable size of CTs -01 Set (e) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates.
Supply & fixing in replacement of Integral LED Flood light Luminaries 100 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as specified & directed.
Trimming of long sfeda Tree over 10 feet from GL, and branches around the solar plant area including any type of T & P required to complete the job and complete all as specified and directed.
Supply, fixing and testing of auto day/ night on and off photocell, LDR sensor switch 10 Amps for lighting on and off photocell, LDR sensor switch 6amps for lighting on and off water proof 220volt 50HZ,AC supply, model No Quick Sense QS-301 complete with all accessories internally pre-wired including connection with 1.5Sqmm copper conductor from main supply to sensor, sensor to fittings including taking down existing complete all as specified & directed.
Taking down any type of fitting but Supply and fix in replacement of Lithium based Energy Efficient Integrated Solar Street Light of 24 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 66, IK 08, High brightness W-LED(160-180 lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with Microwave Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant including tubular pole 6 mtr height with bottom base plate 200x200x12 mm , outdoor dia not less than 65 mm with heavy duty GI pipe or steel thickness 3mm and suitable arrangement to mount solar light as directed on pole including foundation PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate and erection as per manufacturer drawing, providing synthetic enamel aluminium paint over one coat of red oxide complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes ,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed.
All as per Ser item No 115.00 here in before but depth exceeding 1.5 metre and not exceeding 3.0 metre.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed.
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in perpendicular direction to cable as cable protection complete all as specified and directed.
All as per Ser Item No 120.00 here in before but laying only old servicable bricks, complete all as specified and directed. Note:- Old bricks retrieved from Ser Item No 98.00 to 102.00 here in after shall be re-used.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique or manual boring and necessary machine including HDPE pipe of 50 mm to 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supplying and fixing in replacement of light grade galvanised mild steel pipe 80 mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed. Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule.
All as per Item No 123.00 here-in-before but of size 50 mm bore.
Taking down old unsv Steel tubular LT pole and supply and erection of steel tubular swaged poles 9.0 mtr long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, providing synthetic enamel aluminium paint over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip complete all as specified & directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Material & Labour for Cement concrete type B- 2,1:2:4 (40mm graded aggregate) 100 mm thick complete all as specified and directed.
Material & Labour for Rendering 10 mm thick on fair faces of brick work or concrete surface cement paster with the ratio of 1:4 finished even and smooth (without using extra cement) complete all as specified and directed.
Material & Labour for Preparing surfaces plastered or unplastered walls and Priming plastered and other surfaces with alkali resistant priming paint and Distempering walls with distemper two coats with cement base paint complete all as specified and directed.
Material and labour for shifting of transformers/RMUs/Stabilizers VCBs/LT Panels/HT/LT Poles/ ACBs and other materials from one to another site/Power House/Store yard and cleanig and earth work by JCB in Solar plant area remove the trees from HT/LT line by providing crane/hydra/JCB as required at site complete all as specified and directed.
Material & Labour for dismantling the transformer step down/up out door type 11KV/433 Volts of capacity 1250 KVA by disconnecting incomig /outgoing cables and shifting in safe place for repair of transformer plinth with suitable pcc and painting of plinth with cement base paint , including temporary fencing arrangement around temporary shifted place of the transformer until the repaired plinth get dried to avoid untowards incident and to keep continuous solar genration and reconnecting the same and restore the supply at its original place after completion of job. Note:- 1. Repair work planned in such a way that the Solar genration should not be affected for the long time. 2. Contractor must visit the site and understand the nature of work to be done and T & P and store required to complete the job before quoting the rate. 3. Only PCC, plastering, and painting and crane etc requiresd for shifting work will be measured and paid separately under relevent item of schedule of the work . 4. The quoted rate deemed to be included the temporary fencing work , excavation for cables for incoming and outgoing cables including relaying and re-connections and testing, T & P and also the items erronuosly not mentioned in the scope of work but required complete the job.
Material & Labour for repair and servicing of Scada system and data loger system by Scada/ Data loger expert of reputed firm and update the anti virous if required in the system and complete checking of the all wire connection, including update of software and licence fees if payable to the original software designer and keep the scada & data loger system functioning during the entire duration of contract. Note:- 1. Contractor must visit the site and understand the nature of work to be done and T & P and store required to complete the job before quoting the rate. 2. Contractor is liable to pay penality of 1000 Rs per day for Non functioning of scada system by any meas . 3. The quoted rate deemed to be include the software update, licence fees , visiting charge of exper for 'n' nos. 4. Spares to required the scada system to make servicable all the the time during entre period of contract etc.
Supply only hand held electric brush cutter having min 1000 RPM, with grass trimmer min 7000 RPM with 1200 Watts rear motor and assist handle split shaft with accessories for trimming 1 MW Solar plant premises, lawns, substation sorrundings etc. The handles of the cutter must be provided in loop type for easy to operate and move around complete all as specified and directed. Make : Neptune/ Green craft/ Moti garden/ Usha.
Supply only heavy duty PVC body, Rechargeable battery operated double motor pesticide/ chemical high pressure sprayer of 20 ltrs capacity, battery lead acid 12 volt x 12 AH, 4 nozzles, telescopic lance, LED bulb with long wire, on-off trigger with filter, pair of belts, charger, water hose, spray gun etc. with accessories for spraying of pesticide chemical in power houses lawns, substation sorrundings etc. The spray machine must be provided in loop type for easy to operate and move around complete all as specified and directed. Make : Odyssey/ Agri pro/ Hymark.
Material & labour for cleaning of Solar panels by providing 6 Meters Long Solar Panel Cleaning Mop with Microfiber, Wiper, & Adjustable Telescopic Extension Pole 2 to 6 Meters, Multipurpose for Solar Panels complete all as specified and directed.
Material & labour for cleaning of Solar panels by providing Premium Quality 6 Meter Solar Panel Cleaning Brush With 6 Meter Telescopic Pipe & 8 mm PU Pipe complete all as specified and directed.
Note:- Amount of credit of Rs. 132152.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
Raman Electric Trading Co (BID ID -3448204)
Gopal Enterprises (BID ID -3454260)
SANJEEV ENTERPRISES (BID ID -3454373)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
BOQ_820321.xls
BOQ • 0.46 MB
Tender1.pdf
Tender Documents • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .