| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹22.7 L+₹1.5 L (7.32%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | LAXMI CORPORATION L1 | P K SHETH L2 |
|---|---|---|---|---|---|
| 1.00 | Attending complaint /Repair/rectification of leakages to under ground water supply distribution lines 50 mm dia HDPE/PVC/PPR/ GI tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of HDPE/PVC/PPR/GI unions/sockets/nipples as required at site complete all as specified and directed.
Note :Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items. | 80 | EACH JOB | 150 ₹12,000 | 145 ₹11,600 Lowest |
| 2.00 | All as per item No 1.00 above but for GI tubing 80 mm dia | 20 | EACH JOB | 200 ₹4,000 Lowest | 200 ₹4,000 Lowest |
| 3.00 | Attending routine complaints of over ground /on wall/on roof external water supply line including rectification of minor defects by taking down of existing HDPE/PVC/GI tubing up to 25 mm dia, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of gate valve/float valve packing sheet of gate valve and including replacement of HDPE/PVC/ GI Unions/sockets/nipples etc as required at site complete all as specified and directed.
Note: Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items. | 130 | EACH JOB | 100 ₹13,000 Lowest | 110 ₹14,300 |
| 4.00 | All as per item No 3.00 above but for GI/HDPE tubing 32 mm dia to 50 mm dia. | 10 | EACH JOB | 125 ₹1,250 Lowest | 130 ₹1,300 |
| 5.00 | M & L for Detection of leakage in under ground pipe of main water line and attending break down of water supply pipe line and repair to CI /DI water mains of size 200 mm dia at a given notice including necessary excavation in crowded Road in civil area/AF area, in mud, in any type of soil by manual or using special T &P such as JCB etc.De-watering from the trenches by using pump sets, rectification of leakages by using spun yarn, Lead joints, rubber joints, gaskets etc, fixing of CI/DI/HDPE specials such as collars bends/tail peaces etc and making joints complete all as specified and as directed.
Note:-(i) Repair rectified by caulcing of CI pipe are deemed to be incuded with unit rate of job.
(ii) CI specials, lead Joints, D-Joints, Clamp joints, mechanical joint etc shall be measured and paid separately under respective items of sch 'A'.
(iii) Hiring charges of JCB up to 4 Hours, if required, are deemed to be includied of unit rate of each job. Hiring charges.beyond 4 Hours shall be measured and paid separately under respective item of BOQ. | 5 | EACH JOB | 2,600 ₹13,000 | 2,500 ₹12,500 Lowest |
| 6.00 | All as per item No 5 above but for CI/DI water mains of size 80-100 mm bore. | 20 | EACH JOB | 2,000 ₹40,000 Lowest | 2,100 ₹42,000 |
| 7.00 | All as per item No 5 above but for CI/DI water mains of size150 mm bore. | 4 | EACH JOB | 2,200 ₹8,800 Lowest | 2,300 ₹9,200 |
| 8.00 | Hiring of JCB including driver beyond 4 hours of rectification of leakages as per Item No 5 to 7 above complete all as specified and directed.. | 12 | PER HOUR | 1,200 ₹14,400 Lowest | 1,300 ₹15,600 |
| 9.00Notes for Sl item No 1 to 7:- (a) The contractor will be alloted complaints at MES complaint cell on daily basis on all working days and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. | |||||
| 10.00(d) The contractor will intimate MES authority well in advance if electric shut down is required during rectification of complaints. (e) The quoted rated is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M and the same shall be submitted to E/M store yard on daily basis. (g) The stationery required for the job work such as complaints registers, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items. | |||||
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
16 Aug 2025, 6:00 pmClosed
GE (AF) BARODA ,DARJIPURA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
REPAIRS/ REPLACEMENT AND DAY TO DAY PERIODICAL MAINTENACNE OF ELECTRIC PUMP/ STARTERS AND SUCTION DELIVERY LINES, CLEANING OF OH/UG SUMP AT AFS AIRFIELD AND HARNI CAMP AREA VADODARA
2025_MES_721440_1
8984/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AIRFIELD AND HARNI CAMP AREA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹40,000
Yes
11 Oct 2025
19 Jul 2025
18 Aug 2025
19 Jul 2025
16 Aug 2025
2 Aug 2025
19 Jul 2025 - 2 Aug 2025
Amount
Attending complaint /Repair/rectification of leakages to under ground water supply distribution lines 50 mm dia HDPE/PVC/PPR/ GI tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of HDPE/PVC/PPR/GI unions/sockets/nipples as required at site complete all as specified and directed. Note :Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
All as per item No 1.00 above but for GI tubing 80 mm dia
Attending routine complaints of over ground /on wall/on roof external water supply line including rectification of minor defects by taking down of existing HDPE/PVC/GI tubing up to 25 mm dia, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of gate valve/float valve packing sheet of gate valve and including replacement of HDPE/PVC/ GI Unions/sockets/nipples etc as required at site complete all as specified and directed. Note: Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
All as per item No 3.00 above but for GI/HDPE tubing 32 mm dia to 50 mm dia.
M & L for Detection of leakage in under ground pipe of main water line and attending break down of water supply pipe line and repair to CI /DI water mains of size 200 mm dia at a given notice including necessary excavation in crowded Road in civil area/AF area, in mud, in any type of soil by manual or using special T &P such as JCB etc.De-watering from the trenches by using pump sets, rectification of leakages by using spun yarn, Lead joints, rubber joints, gaskets etc, fixing of CI/DI/HDPE specials such as collars bends/tail peaces etc and making joints complete all as specified and as directed. Note:-(i) Repair rectified by caulcing of CI pipe are deemed to be incuded with unit rate of job. (ii) CI specials, lead Joints, D-Joints, Clamp joints, mechanical joint etc shall be measured and paid separately under respective items of sch 'A'. (iii) Hiring charges of JCB up to 4 Hours, if required, are deemed to be includied of unit rate of each job. Hiring charges.beyond 4 Hours shall be measured and paid separately under respective item of BOQ.
All as per item No 5 above but for CI/DI water mains of size 80-100 mm bore.
All as per item No 5 above but for CI/DI water mains of size150 mm bore.
Hiring of JCB including driver beyond 4 hours of rectification of leakages as per Item No 5 to 7 above complete all as specified and directed..
Notes for Sl item No 1 to 7:- (a) The contractor will be alloted complaints at MES complaint cell on daily basis on all working days and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shut down is required during rectification of complaints. (e) The quoted rated is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M and the same shall be submitted to E/M store yard on daily basis. (g) The stationery required for the job work such as complaints registers, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Supply and fixing GI Fittings 15 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
Nipple 75 mm Long
Nipple 100 mmLong
Nipple 150 mm long
Nipple 200 mm long
Nipple 300 mm Long
Elbow
Supply and fixing GI Fittings 20 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Nipple 75 mm Long
Nipple 100 mmLong
Nipple 150 mm long
Nipple 200 mm long
ElBow
Reducer 20 mm x 15 mm
Supply and fixing GI Fittings 25 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
Nipple 75 mm Long
Nipple 100 mmLong
Nipple 150 mm long
Nipple 200 mm long
Nipple 300 mm Long
ElBow
Reducer 25 mm x 15 mm
Reducer 25mm x 20 mm
Supply and fixing GI Fittings 40 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Nipple 75 mm Long
Nipple 100 mmLong
Reducer 40 mm x 25 mm
Reducer 40mm x 20 mm
Elbow
Supply and fixing GI Fittings 50 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Reducer 50 mm x 40 mm
Reducer 50mm x 25 mm
Elbow
Supply and fixing HDPE Fittings 80 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Coupler
All equal Tee
Elbow
Reducer 80 mm x 50 mm
Supply and fixing 20 mm bore ball brass float valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule incl. connector of suitable size and fixed on roof top water tank complete all as specified and directed.
Supply and fixing of 25 mm ball brass float valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule incl. connector of suitable size and fixed on roof top water tank complete all asspecified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying/taking out of cables,CI/GI pipe lines and getting out in sooft/loose soil all as specified and directed.
Returning, filling in trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cms in soil complete all as specified and directed.
Removal of excavated material and deposited where directed at a distance not more than 50M from starting point and not more than 1.5M above ground level complete all as specified and directed.
Taking out unserviceable CI/GI water main from trenches including fittings / fixtures like bend, Tee, Union, Elbow etc with flanged ends all as specified and as directed by Engineer-in-Charge.. Note: Excavation and earthwork will be measured and paid separately under appropriate items.
100 mm bore CI pipe/DI Pipe
80mm bore CI pipe/DI Pipe
80 mm bore GI pipe
40mm bore GI
50 mm bore GI pipe
25mm bore GI pipe
20mm bore GI pipe
Relaying of old serviceable CI/GI tubing obtained from Srl item No. 19 here-in-before above after cleaning the pipes internally and externally with all fittings laid in trenches, floor, under road wall ceiling, floors etc for following sizes :-
100 mm bore CI pipe/DI Pipe
80 mm bore CI pipe/Pipe
80 mm bore GI pipe
50 mm bore
40 mm bore
25 mm bore
20mm bore GI pipe
S&F ductile iron pressure pipes, 100mm dia, class K 7, centrifugally cast with spigot and socket ends conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size for inserting branch connections etc complete all as specified and directed. Notes:- (a) DI pipe shall be laid in trenches at a depth of 0.50 to 1 m below the existing GL (b) Lead Joints / D-Joints will be measured and paid separately. (c) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment. (d) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
Supply and fixing of High density polyethylene pipes (HDPE) PE-80 with SDR-17 of pressure rating 6 kgf/cm2 fixed complete to laid in trenches including taking down existing unserviceable pipes with smooth finished and make embosed on pipe complete all as specified and directed for the following :-
50 mm bore size
25 mm bore size
Supply & laying in trenches/ Walls 20mm GI medium grade, ISI marked with GI fitting such as tees,bend,elbows connecting to existing water main all as specified and directed.
All as per item No. 23 above but 25mm bore GI tubing.
All as per item No. 23 above but 40mm bore GI tubing.
All as per item No. 23 above but 50mm bore GI tubing.
All as per item No. 23 above but 80mm bore GI tubing.
Supply and fix accessories, CI/DI specials upto 300 mm bore confirming to IS 1578 of 196 (any type radius and angle) such as bends, tapers, straight, increasing / decreasing or double socket / flanged end collars, connecting pieces etc, as required at site complete all as specified and as directed. Note: Run lead joint as required deemed to be included in quoted rates.
Supply and fixing of mechanical Joint (MJ) fittings of various sizes and various depth of any type radius and angle) such as tapers, straight, increasing / decreasing or double socket / flanged, connecting pieces etc, as required at site and for the following sizes complete all as specified and as directed
200/250 mm bore size
150 mm bore size
100 mm bore size
80 mm bore size
Dismantling / Taking down unserviceable Gun metal globe/gate valve and supply and fix new Gun metal globe / gate valve, screwed down high pressure with iron wheel head, screwed both ends for GI/PPR pipe including all fittings / fixtures like nipple, union etc complete for following sizes complete all as specified and directed.
50 mm bore size
40 mm bore size
25 mm bore size
20 mm bore size
Supply & fix in repair CI sluice valve PN 1.6, long body,SS Spindle , confirming to IS- 14846 : 2000. Complete and testing complete all as specified and directed of following sizes:-
150 mm bore sluice valve
100 mm bore sluice valve
80 mm bore sluice valve
M&L for construction of brick masonry valve pit chamber of inner dimension 900mmx900mmx1050mm suitable for valves up to 200 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering in CM 1:4, 15 mm thick mixed with water proofing compound, coping in PCC 1:2:4 type B-1, including necessary earth work, form work and provision of MS sheet cover of thickness not less than 2.80 mm on 50 x 50 x 6.0 mm Angle iron frame with locking arrangement, including painting over MS surfaces with two coats of synthetic enamel paint over one coat of red oxide primer etc.,complete all as specified and directed.
M&L for construction of brick masonry valve pit chamber of inner dimension 450mmx450mmx600mm suitable for valves up to 200 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering in CM 1:4, 15 mm thick mixed with water proofing compound, coping in PCC 1:2:4 type B-1, including necessary earth work, form work and provision of MS sheet cover of thickness not less than 2.80 mm on 50 x 50 x 6.0 mm Angle iron frame with locking arrangement, including painting over MS surfaces with two coats of synthetic enamel paint over one coat of red oxide primer etc.,complete all as specified and directed.
M&L for painting the surface of each Pump- Motor set of any capacity with sluice valve completed only two coats of primer paint including scrubbing down with iron brush/sand paper complete all as specified and directed.
M&L for painting of CI/GI pipes at pump houses such as suction and delivery main with two coats of synthetic enamel paint as per MES colour code including preparation of surfaces complete all as specified and directed.
S&F in replacement for three core flat copper cable, PVC insulated, PVC sheathed for submersible pump set 1100 volt 4 sqmm size after taking down the old UNSV copper cable complete all as specified and directed.
S&F in replacement Pressure gauge suitable for bearing pressure upto 20 Kg / Sq cm complete all as specified and directed. Make : MEI /GURU /Uday
M&L for cleaning of under mentioned RCC over head reservoir/under ground sump/semi under ground sump of any size and any height of staging by using mechanical means and scientific cleaning by carry out the following stages of cleaning process for disinfection of surfaces:- (a) Cleaning of all external surfaces with hot water and Odor remover. (b) The inner surface of the walls and ceilings of the tank shall be cleaned with the pressure jet pump after dewatering in the tank. (c) After through cleaning of the tank, removal of algal calcination and other dust particles with high pressure including hot water treatment @50 degree centigrade. (d) Vacum cleaning and sludge shall be removed by using pump and the sludge has to be disposed off at a places as directed. (e) After removing the sludge from tank, the floor and inner surfaces of the tank shall be cleaned by using an industrial vaccum cleaner and the tank shall be made fully dust free and disinfection with bio-degradable chemical/anti bacterial spray and surfaces to be proven non toxic. (f) After the treatment as mentioned at (e) above, the inner surfaces of walls and ceiling shall be traeated with UV Radiation/Ozonization with UV rays. (g) After complete treatment is carried out, all inlet, over flow, delivery, wash out pipes, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surface and also the surfaces of sluice valves shall be painted with P.O. Red paint and writing "capacity of tank, date of cleaning and due date of cleaning" on walls as specified and as directed. (h) Periodicity of under ground sump's cleaning is minimum six month.
20000 Gallon (UG Sump)
35000 Gallon (OH tank)
100000 Gallon (Semi UG sump)
10000 Gallon (UG Sump)
Flushing/de-silting of accumulated soil from inside the borewell up to 250 mm dia and depth up to 150 meter by using air compressor/ special equipments of existing borewells including surging and flushing the bore at a pressure of 7 Kg / Sq cm complete with compressed air and flushing the sand, mud etc from the bore well till discharge of the fresh water, including testing of water samples for chemical and bacteriological tests and yield testing for 4 hours complete all as specified and directed . Note: The rate shall be inclusive of hiring of Air compressor /special equipment, diesel, tools and Accessories including transportation and skilled man power to execute the work.
Supply and fix Gland packing for sluice valve and pumps of size 6mm thick complete all as specified and directed.
M & L for dismantling of defective sluice valve for repairs such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc complete all as specified and directed of following sizes:-
80 mm bore.
100 mm bore.
150mm bore.
200mm bore.
M & L for Framed work as in doors or gates of angle (40X40X5)or other section with gasket plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete complete with locking arrangement all as directed.(Under ground Sump)
M & L for Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc. as required for size 5 mm complete all as specified and directed.
M & L for 20 mm bore size Drilling and tapping cast iron/GI water mains (in position) for branch connections of the internal dia including ferrule of following sizes complete all as specified and directed.
Labour only for Disconnecting the existing non functional submersible pump set from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position along with existing column pipe 50mm dia and existing submersible cable of any size from the bore well (approximately 450 feet depth of pump set from GL) and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed. NOTE: - ( i ). Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc. shall be arranged by the contractor at his own cost. (ii). Number of column pipe may vary from 30 to 50, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints along with flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately.
Lowering down of the submersible pump set of any description and any capacity & in any position using the chain pulley arrangement from bore well along with column pipe 50 mm dia and submersible cable of any size (approximately 450 feet depth of pump set from GL) complete all as specified and directed including making necessary electric connections & testing the pump set after lowering complete all as specified and directed.
Supply and fixing the following items/ spare parts suitable for submersible pump set of upto 5/7.5 HP capacity dismantled under Schedule ‘A’ item No.42 above all as specified and directed by the Engineer-in-Charge.
Cast iron stage bowl
Gun metal neck ring make NITCO’ or equivalent
Anti magnetic stainless steel pump shaft with key made : DD/’KSB or equivalent
Impeller gunmetal make: NITCO/ KSB or equivalent
Stainless steel sleeve( inlet) make : DD/KSB or equivalent
Stainless steel sleeve( outlet) make : DD or equivalent
Running bush outlet of gun metal
Stage bowl cover
Bolt stud with nut and washers
Running bush inlet of gun metal
Strainer stainless steel
Shaft nut with washer
Connector for motor
Steel bolt set
Key for thrust plate
Thrust bearing[set of 02]
Cable pressure washer
Thrust plate
Motor bearing bush (LB)
Thurst bearing set
PVC Impeller
Stage casing
Stage casing sleeves
Suction bush
Pump NRV
Discharge out let Bush LB
Discharge out let.sleeve
Middle bush LB
Middle sleeve
Pump saft
Neck ring stage casing
Sand guard
Oil sealing
Rewinding the submersible motor upto 7.5/ 5 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etc, including taking out dismentling, transporated to local work shop and refixed in position after rewinding complete all as specified and directed.
Dismantling & taking out existing U/S pumping unit of pump motor set installed at Jagtnaka pump house and S & F of new motor pumping unit (centrifugal Pump) of 100x100 mm size suction and delivery with 2900 RPM and discharge of 100 mtr3/Hrs on 35 Mt head , coupled with 415 V 3 phase of 25 HP capacity existing motor including stainless steel impeller, mechanical seal, MS coupler with rubber packing & stainless steel shaft complete assembled /alligned with existing motor on common iron frame recommended by OEM and grouted on foundation including testing and commissioning complete all as specified and directed. Note- 1.PCC/RCC foundation with frame for grouting of Pump is deemed to be included in quoted rate. Required length of MS pipe and fabrication of suction and delivery pipe shall be measured and paid separately. 2. It is suggusted for bidders to visit the site (Jagatnaka Pump house ) before qouting the rate. In case of non execution of the said work a penalty of Rs 50000/- will be recovered from bidders dues. 3. Old U/S pump unit will be deposited in MES store yard and cost of the transporting the same shall deemed to be included in quoted rates.
Labour for repair/service checking and calibration including taking down unserviceable parts of starter control penal of any type for Its proper star della opertion and checking the the all electrical conections and control wiring of panels and replace the minor spares such as indication lamp push button etc as required testing of starter with respective pump set all as specified and all as directed. Note: Supply and fixing of spares required such as timer switch, single phase preventer, contactors, relays etc will be measured and paid separately
Supply and fixing single phase preventer (SPP) for 440 volts starter panel any type complete all as specified and directed. Make - Havells, L&T, C&S, ABB
Supply and fixing timer switch for 440 volts starter panel any type complete all as specified and directed. Make - Havells, L&T, C&S, ABB
Supply and thermal over load relay with auto/manual reset type upto 22 amps capacity for 440 volts starter panel any type complete all as specified and directed. Make - Havells, L&T, C&S, ABB
Supply only push button of Red/Green colour complete all as specified and directed.
Supply and fixing control coil for Contactor suitable for starter complete all as specified and directed.
Supply and fixing auxilary contactor 25A 2P Contactor for starter complete all as specified and directed.
S&F in repair of contactor 4 pole AC 3 with AC coil 415 volt 50 Hz, 70 Amp for motor starter complete all as specified and directed.
S&F in repair of contactor 3 pole with AC coil 415 volt 50 Hz, 50 Amp for motor starter complete all as specified and directed.
Supply and fix in repair fully automatic star delta starter complete with Power contactor , Overload realay, timer single phase preventor etc of following capacity complete all as specified and directed.
For 50 HP motor
For 25/30 HP motor
For 12/7.5 HP motor
Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 3 pole, 415 Volt AC supply, 250 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directed.
M & L for collection of the sample from the various site (like pump house , Bore well etc) and carrying out water testing (Biological & Chemical test) in authorised lab complete all as specified and directed .
M & L for Taking out and rewinding of openwell submersible motor 1 HP with PVC insulated submersible rewinding wire of suitable gauge/size as per existing including rotor balancing, testing and connection of submersible cable and cable gland including taking down old winding wire complete all as specified and directed.
S&F in repair sensor system of pressure booster pump of 1 HP including testing on ground complete all as specified and as directed.
M & L for rewinding of monoblock/ Centrifugal pump (Motor), 3 phase, 415 volt with supper emamelled copper rewinding wire of suitable size/gauge as per existing and providing insulation varnishing, heating, testing including taking out the existing winding wire complete all as required for completion of JOB for 40/50 HP capacity pumps.
All as per item No. 60 here in before but Motor of capacity 30 HP
All as per item No. 60 here in before but Motor of capacity 25 HP
All as per item No. 60 here in before but Motor of capacity 7.5 HP
All as per item No. 60 here in before- but Motor of capacity 5 HP
M&L for servicing / greasing of bearings and cleaning to squirrel cage Induction type motor of capacity upto 7.5 HP / 12.5 HP, 3 phase 415V, cleaning. varnishing, heating and drying re-erecting, aligning with the pump, testing including replacement of gland packings, painting the motor with two coats of synthetic enamel paint after preparing the surfaces and split cauge centrifugal pump set including disconnecting/reconnecting the suction and delivery line of any size with replacement of suction/deliverry rubber gaskets by dismantling of motor from the pump set removing the stator/rotor separately, cleaning, and graseing pump and motor the bearings (long life grease) including replacement of bearing, minor parts such as nuts & bolts, washers, stud, O ring, coupling, locking key, air vent valve etc re erecting along with pump with proper allingnment in common base frame with sprit level, and laminated packing sheets in any situation, testing, complete all as specified and directed. Note : (i) Measure spare parts shall be measured and paid separately under respective item of BOQ. (ii) Transportation for repair at workshop shall deemed to be included with unit rate of item.
--ditto but 25/30 HP 3 Phase 415
--ditto but 40HP/ 50 HP 3 Phase 416
Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 50/40 HP having discharge 400 LPM at 990 mtr head complete all as specified and directed:-
Motor bearing . Make : SKF/NBC/TATA/FAG/ UBC.
Motor cooling fan
Pump motor MS coupling
L-190 spider.
Cover bolts & washers
Pump bearing No. 6307 of Make : SKF/UBC/TATA/FAG/ NBC
CI impellar DB 80/20 for existing 50/40 HP centrifugal pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Starter relay of Make : Jyoti, Range 36-60
Magnet coil of Make Jyoti.
Starter copper contact set
Starter base plate
Single phase preventor
Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 25 HP/30 HP complete all as specified and directed:-
Motor cooling fan
Pump motor MS coupling
L-190 spider.
Cover bolts & washers
Pump bearing Make : SKF/UBC/TATA/FAG/ NBC
Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC
CI impellar suitable for existing pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 12.5/7.5/ 5.0 HP complete all as specified and directed:-
Motor cooling fan
Pump motor MS coupling
L-190 spider.
Cover bolts & washers
Pump bearing Make : SKF/UBC/TATA/FAG/ NBC
Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC
CI impellar suitable for existing pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Supply and fix in repair of submersible pump motor starter of 5 HP in sheet meatla encloser with power contractor, protection relay as suitable at site complete all as specified and directed.
M&L for complete detailed service and maintenance of granular type chlorine based granular chlornation disinfectant treatment plant including repairs and replacement of minor spares such as 3/8 " PVC suction and discharge tubing suitable to the dosing pump, NRV, nuts, bolts, PRV and Y Strainer etc such as required for satisfactory functioning of the unit complete all as specified and directed.
S&F Chemical feed dozer model RC series Chemical Dosing (metering) Pump electromagnetic type with suction & discharge tubing, spring loaded anti siphon valve, foot valve etc complete with maximum discharge of 6 ltrs / hr with 4 kg back pressure motor operated suitable for mixing hypo chloride of capacity 100 ltr tank with stroke adjustment of 0 to 6 LPH complete with fittings and piping network.
Supply & provide Aquafit (Calcium hypo chlorite) 65%-70% chlorine content (Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chlorite packed in 45 Kg drum complete all as specified and directed. Make : Auafit & Equivalent.
Supply of water through tanker/bouser including transportation from source to U/G sump Harni camp/Harni Air field area Afs Baroda. The water should have the following main factors :- (a)Water should be clear and free from all suspended matters both organic & inorganic matter. (b) Water should be free from taste and odour. (c) Water should be colour less and no vegetable stain should be present. (d) Water should be soft that it should not contain dissolved impurities like calcium or magnesium bicarbonate and Sulphates. (e) Water should be soft and should be free from all pathogenic organism causing diseases. (f) Copy of gate entry at guard room with vehicle No date and time shall be submitted duly defaced by Engr in charge before claiming payment. Note : Water analysis duly tested by authorised lab will be rendered by supplier before supplying the water.
M & L for cleaning of static water tank(SWT) 100000 Ltrs with all T&P and man power required to pump out the existing water and removing the sludge and greet from 6f ft deep water collector and throwing it out side 50Mtr away from site complete all as specified and directed.
Supply and fixing of brass foot valve of following sizes incl lifting of UNSV foot valve from UG sump from any depth by removing of suction pipes of pumps complete all as specified and directed.
For 100 mm dia pipe
For 80/50mm Dia pipe
Supply and fixing of brass NRV of following sizes incl lifting of UNSV foot valve from UG sump from any depth by removing of suction pipes of pumps complete all as specified and directed:-
For 100 mm dia pipe
For 80/50mm Dia pipe
M & L for dismantling of defective sluice valve for repairs/replacement of spindle with gate including nut bolt with washers with packing and refixing at its original position, testing on completion etc complete all as specified and directed of following sizes:-
80 mm bore.
100 mm bore.
M&L for cleaning once in a month by spraying of weeds herbicide to kill unwanted vegetation around near E/M installation, cutting grass, removing unwanted bushes, removing debris etc and making good of undulated ground by filling fresh soil and levelling the area to existing ground level, removing unwanted debris from the premises at a distance exc 50m from site complete all as specified and directed. Note: (i) Location - Harni Pump house, Semi UG tank area and Aircraft pumphouse, Semi UG tank area approx area -450 SQM. (ii) In case of damage to any existing assets such as UG cables, Pipelines or any type of things, contractor has to make good as per the existing without any extra cost to Government.
Demolition of old PCC foundation any type and size including removal of anchor bolt and removing debris from site at safe place in eco friendly manner complete all as specified and directed.
M&L for PCC work for pumpset platform and other misc pedestal supports, using cement concrete type B1, mixing ratio 1:2:4 using 20mm graded aggregate complete including form work as required complete all as specified and directed.
S&F Flex sheet Glow sign Board etc of size 1.8 mtr x 1.2 mtr x 20 cm made out of 1 mm GI sheet thick including LED tube light and connecting cable for glow and GI pipe 50 mm GI pipe stand , PCC 1:2:4 for stand foundation, flex sheet is computirsed printed location of installation and other details complete all as specified and directed.
Note for all items :- If any item gets repeated in this schedule, the lowest rate quoted for those same items by the L-1 bidder shall be considered for payment and decision of Accepting Officer i.e. GE(AF) Baroda in this regard shall be final and binding.
P K SHETH (BID ID -3395730)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .