Tender Value
₹2.6 Cr
EMD Value
₹5.3 L
Closing Date
10 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
Note for Technical Eligibility Criteria: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/ registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate
Definition of Single Similar Work: For the purpose of this work, Single Similar work shall be taken as "Any signal interlocking works involving El or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA-SSDAC) or Automatic signalling" (PCSTE/SR Letter No.SG.191/Similar Nature of work, Dt. 25.02.2026 Sl No.14).
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Replacement of Signal posts, Batteries, Mechanical gadgets, Replacement of over aged defective cables and other reliability improvements works at LC gates in TVC Division.
TVC-SNT-SIG-26-27-13~SR
TVC-SNT-SIG-26-27-13
Open
Works - General
6 Months
Thiruvananthapuram, Kerala
₹0
₹5.3 L
18 Aug 2026
18 Aug 2026
27 Aug 2026
68 items across 1 schedule · ₹2,01,10,397.04 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As- made circuit diagrams also as mentioned above" | Sheet | 60.00 | 382.12 | 22,927.2 |
| 2 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 10.00 | 1,707.55 | 17,075.5 |
| 3 | S u p p l y o f Transformer o f C a p a c i t y 230V A C / 1 1 0 V A C , 1 0 0 0 V A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest or IRS: S-72 | Numbers | 4.00 | 8,996.32 | 35,985.28 |
| 4 | Supply of Self Regulating Battery Charger 230V AC/24V DC, 15A (signalling) shall be suitable for a x l e counter as per RDSO spec no.lRS S : 86/2000 with amendment 4 or latest. | Numbers | 4.00 | 36,000 | 1,44,000 |
| 5 | Supply of Stackable type VRLA batteries 2V, 200Ah - 1 cell as per RDSO Specifications IRS S: 93/96 with Amnd 1 or latest | Numbers | 2380.00 | 4,074.88 | 96,98,214.4 |
| 6 | "Supply a n d installation o f A S M panel, pre- wired(without Integrated power supply as per RDSO/SPN/165 o r latest). Necessary interface cable from IPS to ASM panel is not covered." c ) S u p p l y o f S e c o n d a r y c e l l s - 2V-120AH capacity | Numbers | 137.00 | 4,224 | 5,78,688 |
| 7 | Supply of track feed battery charger IRS:S 89- 2013 | Numbers | 2.00 | 4,375.25 | 8,750.5 |
| 8 | Supply of 'B type choke IRS:S 65-83 | Numbers | 4.00 | 2,855.6 | 11,422.4 |
| 9 | Supply of Battery charger 110V/24V-15A (As per IRS Spec. No. IRS:S 86-2000). | Numbers | 14.00 | 33,496.46 | 4,68,950.44 |
| 10 | Supply, installation a n d wiring of Transformer rectifier 110VAC/24V DC - 2A capacity at Power room/ apparatus cases and connecting it to the r e l e v a n t c i r c u i t as per approved circuit diagram using wire PVC 3/0.75mm copper and painting of particulars as per Railway practice. ( A s p e r I R S Spec. No. IRS:S 91-2014). [Transformer rectifier 1 1 0 V AC/24VDC - 2A capacity, wire PVC 3/0.75mm copper and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 10.00 | 9,557.1 | 95,571 |
| 11 | S u p p l y , o f Transformer 110VAC/110VAC - 500VA capacity | Numbers | 4.00 | 5,256.9 | 21,027.6 |
| 12 | Installation of power equipments like battery chargers, transformers, transformer rectifiers, invertors, D C - D C converto rs etc., in the apparatus cases and wiring the same using w ire P V C 7/1.4mm a n d 3/0.75mm copper as per the approved wiring diagram and painting of particulars i n the inside of the doors of the apparatus cases. The work also includes provision o f protective arrangements i n bare terminals carrying high voltages. (Supply of power equipments is not included in this schedule).[Wire PVC 7/1.4mm and 3/0.75mm copper, protective arrangements, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 14.00 | 1,708.01 | 23,912.14 |
| 13 | Supply of 2 4 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 4000.00 | 388.15 | 15,52,600 |
| 14 | S u p p l y o f 1 2 C x 1 . 5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable a s p e r IRS: S-63/2014 REV.4 | Metre | 4000.00 | 215.92 | 8,63,680 |
| 15 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per t h e instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 126.00 | 262.65 | 33,093.9 |
| 16 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 5820.00 | 64.1 | 3,73,062 |
| 17 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 .6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t s i t e . (Laying of cables is not included in this schedule). | Metre | 20.00 | 314.41 | 6,288.2 |
| 18 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ram m ing a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1 m trench shall b e f r o m t h e b o t t o m o f sleepers for track crossings. Laying o f cables a n d DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 174.00 | 385.45 | 67,068.3 |
| 19 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes w ith couplers/collars is not included in this schedule). | Metre | 78.00 | 501.03 | 39,080.34 |
| 20 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 202.00 | 208.54 | 42,125.08 |
| 21 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Metre | 60.00 | 182.87 | 10,972.2 |
| 22 | Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 7600.00 | 18.18 | 1,38,168 |
| 23 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 5820.00 | 62.99 | 3,66,601.8 |
| 24 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 5820.00 | 15.4 | 89,628 |
| 25 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of the f o u n d a t i o n a n d r e fi l l i n g t h e p i t and consolidating it by ramming. The cable markers shall b e provided a t a n interval of 20 Mtrs. w i t h i n statio n l i m i t s a n d 5 0 Mtrs. outside s t a t i o n l i m i t s throughout t h e cable route, diversions a n d a l s o a t every track/road crossing." | Numbers | 126.00 | 123.35 | 15,542.1 |
| 26 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables and placing closely one layer of country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 4.00 | 949.05 | 3,796.2 |
| 27 | " R o a d c r o s s i n g / T r a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl of cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination a s directed b y t h e site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre | 20.00 | 1,351.45 | 27,029 |
| 28 | Supply of Main LED Signal Aspect - Green as p e r R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 87.00 | 10,030 | 8,72,610 |
| 29 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 94.00 | 8,850 | 8,31,900 |
| 30 | Supply of Main LED Signal Aspect - Red as per R D S O Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 75.00 | 9,233.5 | 6,92,512.5 |
| 31 | Manufacture and supply o f Enameled Number p l a t e s a s p e r drawing No.TY/08/2008 with fixing arrangements and fixing t h e m o n the existing Signals a s per the instructions of Railway representative at site.[Enameled number plates w ith fixing arrangements with b o l t s a n d n u t s s h a l l be supplied by the Contractor]. | Numbers | 80.00 | 305.25 | 24,420 |
| 32 | Supply o f Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall w ith necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) | Numbers | 17.00 | 5,841 | 99,297 |
| 33 | Supply o f Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall w ith necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers | 10.00 | 4,737.7 | 47,377 |
| 34 | Supply of surface base t o suit CLS Signal pole 140mm d i a with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 16.00 | 6,814.5 | 1,09,032 |
| 35 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary i n s p e c t i o n a s p e r specification/ drawing/ d e s c r i p t i o n e n c l o s e d i n this document. a)Supply o f ladder w i t h platform (4.6m) for CLS(Galvanised) | Numbers | 12.00 | 5,698 | 68,376 |
| 36 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary i n s p e c t i o n a s p e r specification/ drawing/ d e s c r i p t i o n e n c l o s e d i n this document. b)Supply o f ladder w i t h platform (3.6m) for CLS(Galvanised) | Numbers | 10.00 | 5,494.5 | 54,945 |
| 37 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting s o c k e t , w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers | 4.00 | 16,874 | 67,496 |
| 38 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting s o c k e t , w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 13.00 | 14,278 | 1,85,614 |
| 39 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 4.00 | 3,569.5 | 14,278 |
| 40 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 4.00 | 2,645.5 | 10,582 |
| 41 | Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt-1 or latest (with one extra ward plate andwith case) contact configuration-4F/4B and as per IRS:S- 23, IRS:S@58"44@ IRS:46 or latest. | Numbers | 50.00 | 10,722.72 | 5,36,136 |
| 42 | Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 55.00 | 4,366.63 | 2,40,164.65 |
| 43 | Supply of Relay, AC Immune, plug-in-type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers | 30.00 | 4,639.03 | 1,39,170.9 |
| 44 | Supply of electronic time delay units (120/60 s e c s ) w i t h p l u g b o a r d s , connecto rs and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 4.00 | 2,742.03 | 10,968.12 |
| 45 | Supply of lamp proving relays(QECX-61) for a)LED aspects w i t h p l u g boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 40.00 | 5,901.5 | 2,36,060 |
| 46 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 4.00 | 4,945.51 | 19,782.04 |
| 47 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 1.00 | 8,786.26 | 8,786.26 |
| 48 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers | 15.00 | 15,009.6 | 2,25,144 |
| 49 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts a n d washers, f o r fi x i n g PBT terminal/Fuse B l o c k , o t h e r fi x i n g b o l t s and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus b a r s , teakwood 5 0 m m x 50mm for cable c l a m p s , 2 5 m m x 1 0 0 m m f o r base planks, phynolic sheet 6 m m thick o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 200.00 | 167.99 | 33,598 |
| 50 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts a n d washers, f o r fi x i n g PBT terminal/Fuse B l o c k , o t h e r fi x i n g b o l t s and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus b a r s , teakwood 5 0 m m x 50mm for cable c l a m p s , 2 5 m m x 1 0 0 m m f o r base planks, phynolic sheet 6 m m thick o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination using PBT fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 10.00 | 201.27 | 2,012.7 |
| 51 | Fi x i n g o f additional p l u g boards, 5 0 ways terminal blocks and wiring o f additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips and 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood p l a n k 2 5 m m t h i c k for fi x i n g resistors a n d condensers, soldering m a t e r i a l s , b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish a n d a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay | 9.00 | 726.5 | 6,538.5 |
| 52 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e work includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. | Per Relay | 30.00 | 695.67 | 20,870.1 |
| 53 | Supply o f Double w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming t o specification N o . IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification | Metre | 174.00 | 365.19 | 63,543.06 |
| 54 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 202.00 | 457.88 | 92,491.76 |
| 55 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 60.00 | 1,119.16 | 67,149.6 |
| 56 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 300.00 | 61.44 | 18,432 |
| 57 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 70.00 | 93.02 | 6,511.4 |
| 58 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 15.00 | 103.84 | 1,557.6 |
| 59 | Supply of E-Type Locks | Numbers | 40.00 | 1,234.88 | 49,395.2 |
| 60 | Fi l l i n g e a r t h a r o u n d l o c a t i o n boxes/signal foundations for a width of 0.5m on all sides, up t o a level 150mm below t h e foundation top. This w ork includes consolidation of earth by watering and ramming.The earth shall be taken from Railway premises as instructed by Railway representative at site. | cum | 10.00 | 231.3 | 2,313 |
| 61 | Excavation o f pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation b o l t s , cem ent, M sand, stone jelly o f size 20/25mm d i a a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 12.00 | 9,213.28 | 1,10,559.36 |
| 62 | "Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete o n S i g n a l p o l e / Off-set bracket, ( f o r LED/ filament bulbs) with lenses, triple p o l e lamp h o l d e r , filament switching u n i t s , CLS transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting of ladder shoe, fixing o f number plates, marker board, lens guard, fixing of speed limit board wherever necessary, termination of tail cables, wiring o f signal unit with P V C wire 3/0.75mm copper, provision of EWS locks, and painting of one coat o f red oxide a n d t w o c o a t s of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED a s p e c t s , c u r r e n t regulators, l a m p holders, l a m p s , fi l a m e n t s w i t c h i n g u n i t a n d CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, s t o n e j e l l y 20/25mm d i a , M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, E W S locks, a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 27.00 | 8,287.08 | 2,23,751.16 |
| 63 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing t h e opening created f o r entry o f new cables i n the apparatus cases w i t h masonry b r i c k work and sealing t h e b o t t o m o f the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 450.00 | 73.59 | 33,115.5 |
| 64 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 200.00 | 151.09 | 30,218 |
| 65 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 24.00 | 188.86 | 4,532.64 |
| 66 | Charging and installation o f secondary cells of t h e following capacities, o n existing battery stand/ RCC slabs in the battery room. The work involves charging of secondary cells, fixing and c o n n e c t i n g the batteries with strips, manufacture and fixing of teakwood terminal box, termination of cables, wiring with suitable w i r e PVC 7/1.40mm a n d 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision of battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n t h e r e l a y r o o m . The particulars shall be digitally using good quality "laminated gum sheet, provision of hydrometer - 1 N o . o n a stand a n d battery tester-1 No. Charging o f secondary cells shall b e done by t h e contractor through reputed agencies. (Supply of secondary cells is not covered in this schedule). [Teakwood plank 2 5 m m thick for manufacturing termination box with locking facility, w i r e P V C 7 / 1 . 4 m m a n d 3/0.75mm c o p p e r , anti-corrosive p a i n t , v a r n i s h , PVC p i p e s / casing, a n d a l l o t h e r miscellaneous materials required f o r t h i s w o r k s h a l l be supplied by the contractor]." c)Installation of 2V-120AH cell on existing stand/ slabs(Per Unit = Per Cell) | Per Unit | 12.00 | 793.17 | 9,518.04 |
| 67 | Installation of charged secondary cells of the f o l l o w i n g c a p a c i t i e s i n a p p a r a t u s cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a)Installation o f 2V-120AH cells i n apparatus cases(Per Unit = Per Cell) | Per Unit | 125.00 | 576.37 | 72,046.25 |
| 68 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work i n c l u d e s b r e a k i n g t h e concrete foundation,closing t h e r e s u l t a n t p i t and resurfacing it by ramming and levelling. | Numbers | 4.00 | 3,083.03 | 12,332.12 |
| Schedule total | ₹2,01,10,397.04 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
GCCCorrectionslip1-5.pdf
ATTACHMENT
GCCCorrectionslip6-11.pdf
ATTACHMENT
SOR2022BOOKLET.pdf
ATTACHMENT
LetterPoliceVerification.pdf
ATTACHMENT
CableCutpenaltyLetter.pdf
ATTACHMENT
ModelformofBankGuarantee_1.pdf Model form of Bank Guarantee
ATTACHMENT
ScopeofworkandATC.pdf
ATTACHMENT
ModelformofBankGuarantee_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].