| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC AMARPUR GOMATI DISTRICT TRIPURA | ₹25.1 L | L1 | Accepted-AOC Being a 1st lowest |
| 2 | L2₹26.7 LRejected-AOC | ₹26.7 L | L2 | Rejected-AOC Being a 2nd lowest |
| 3 | L3₹30.3 LRejected-AOC JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | ₹30.3 L | L3 | Rejected-AOC Being a 3rd lowest |
| Sl No | Description | Qty | Unit | KAJAL DAS L3 | M/S GHOSH ELECTRICAL ENGINEERING L2 | RAKESH DAS L1 |
|---|---|---|---|---|---|---|
| 2.00Schedule-A Supply | ||||||
| 3.00 | Supply of 9.0 mtr. Long PCC Pole, 200Kg. Working load as per specification and drawing. | 60 | Nos. | 6,100 ₹4.3 L | 7,000 ₹5.0 L | 5,000 ₹3.5 L |
| 4.00 | Supply of 8.0 mtr. Long PCC Pole, 200Kg. Working load as per specification and drawing. | 45 | Nos. | 5,600 ₹3.0 L | 6,000 ₹3.2 L | 4,500 ₹2.4 L |
| 5.00 | Supply of Painted MS stay set complete with 16 mm. dia. 1.8 mtr. long painted stay rod, anchor plate of size 300 X 300 X 8 mm. thick, turn buckle of length 356 mm. with 300 mm. long threaded adjustable 16 mm. dia. MS rod and thimble | 62 | Set | 550 ₹40,238 | 400 ₹29,264 | 600 ₹43,896 |
| 6.00 | Supply of Galvanized Stranded stay wire (7/2.5mm) | 0.25 | MT | 65,000 ₹19,175 | 65 ₹19.18 | 70,000 ₹20,650 |
| 7.00 | Supply of Stay Insulator HT-11KV (Porcelin) | 47 | No | 30 ₹1,663.80 | 20 ₹1,109.20 | 32 ₹1,774.72 |
| 8.00 | Supply of Stay Insulator LT (Porcelin) | 15 | No | 20 ₹354 | 20 ₹354 | 30 ₹531 |
| 9.00 | Supply of 100X50X50X6MM MS channel | 1 | MT | 70,000 ₹82,600 | 65 ₹76.70 | 60,000 ₹70,800 |
| 10.00 | Supply of 75X40X40X6MM MS channel | 2 | MT | 70,000 ₹1.7 L | 65 ₹153.40 | 60,000 ₹1.4 L |
| 11.00 | Supply of 65X65X6MM MS angle | 0.5 | MT | 70,000 ₹41,300 | 65 ₹38.35 | 60,000 ₹35,400 |
Tender Value
₹34.2 L
EMD Value
₹68,420
Closing Date
16 Dec 2025, 4:00 pmClosed
Deputy General Manager, Electrical Division Udaipu
Deputy General Manager, Electrical Division Udaipur
Extension of HT/LT line including construction of 15x63 KVA distribution Sub-station for segregation of DTW scheme from other consumer for quality power supply under Electrical Division Udaipur.
2025_POWER_68035_1
ED/UDP/2025-26/11
Open Tender
Electrical Works
Electrical Division Udaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹68,420
Electrical Division Udaipur
10 Feb 2026
5 Dec 2025
16 Dec 2025
5 Dec 2025
16 Dec 2025
5 Dec 2025
9 Dec 2025
Schedule-A Supply
Supply of 9.0 mtr. Long PCC Pole, 200Kg. Working load as per specification and drawing.
Supply of 8.0 mtr. Long PCC Pole, 200Kg. Working load as per specification and drawing.
Supply of Painted MS stay set complete with 16 mm. dia. 1.8 mtr. long painted stay rod, anchor plate of size 300 X 300 X 8 mm. thick, turn buckle of length 356 mm. with 300 mm. long threaded adjustable 16 mm. dia. MS rod and thimble
Supply of Galvanized Stranded stay wire (7/2.5mm)
Supply of Stay Insulator HT-11KV (Porcelin)
Supply of Stay Insulator LT (Porcelin)
Supply of 100X50X50X6MM MS channel
Supply of 75X40X40X6MM MS channel
Supply of 65X65X6MM MS angle
Supply of Polimer insulators 5KN with hardware fittings, hardware etc. as required as per the technical specification, approved drawing and scope of work. 11KV Pin insulator with hardware fittings.
Supply of 11 KV Polimer composite Disc Insulator 45KN
Supply of 11 KV Disc Fittings (6/1/2.59SQMM)
Supply of ACSR (6/1/2.59 sq mm Weasel)
Supply of 8SWG GI Wire(4mm)
Supply of 9 KV, 5KA Gapless Silicon Polymeric Lightning Arrestors
Supply of Triple pole (3 phase), vertical type 12 KV, 200 Amp. Manually gang operated, air brake switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification.
Supply of Triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along.
Supply of PVC insulated PVC sheated 1100 V Grade single core PVC cable 70 sq.mm
Supply of PVC insulated PVC sheated 1100 V Grade single core PVC cable 35 sq.mm
Supply of Single circuit re-wirable, extended type porcelain Kit Kat Fuse Units 200 Amp as per specification & drawing.
Supply of Lugs 70Sqmm (Aluminium)
Supply of Brown glazed porcelain shackle insulator of size 90x75 mm with hole diameter 15 mm for low voltage line of mechanical strength 11.5 KN conforming of 2 ISS:1445/1977
Supply of G.I. Straps and Bolts, 185 mm x 30 mm x 3 mm including Supply of Nuts & Bolts etc. as required.
Supply of MS Nuts & Bolts (12X300mm)
Supply of MS Nuts & Bolts (16x75mm)
Supply of 2.5mtr. Long , 40mm dia G.I.Pipe ( Make: TATA/ JINDAL)
Supply of 60Kg Salt & 55Kg Charcoal ( For 1 Pit).
Supply of 1/2'' dia polythene pipe
Supply of Febricated clamps of assorted size of MS flat (50 x 6 mm) with double coat of red oxide primer coating .
Supply of Press Board cutting Machine (For transformer repairing workshop)
Supply of MS Chain Pully Block-3 Ton Capacity
Erection
Erection & commissioning including carriage upto work site of 9.0 Mtr long PCC Pole direct in earth i/c excavation, back filling & ramming etc as reqd.(the Pole should be buried 1/6th.of their length) as per Technical specification.
Erection & commissioning including carriage upto work site of 8.0 Mtr long PCC Pole direct in earth i/c excavation, back filling & ramming etc as reqd.(the Pole should be buried 1/6th.of their length) as per Technical specification.
Erection & commissioning of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect.
Carriage of materials such as Cable, AAC, AAAC, ACSR, G.I.Wire,Cross-Arm,Stay Set,Insulators etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25KM & 50KM.
Erection of fabricated M.S.Channel Cross-Arm, 0.8Mtr. Long 100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 2.8Mtr. Long 100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated M.S.Channel Cross-Arm, 2.8 Mtr. Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated M.S.Channel Cross-Arm, 2.2Mtr. Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated M.S.Channel Cross-Arm, 1.2Mtr. Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated M.S.Channel Cross-Arm,0.3 Mtr. Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated M.S.Angle Cross-Arm,2.8 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated f M.S.Angle Cross-Arm,2.5 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated M.S.Angle Cross-Arm, 1.6 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of fabricated "C" type bracket for LT 5-wire of 65 x65 x 6 mm( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection & commissioning of 11KV Pin insulator along with Pin.
Erection & commissioning of 11KV Single Disc insulator set along with necessary fittings.
Laying, Stringing & commissioning of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia 'weasel' including hoisting & binding etc. Complete as required.
Laying & strining of 1KM (Single Conductor), 8SWG GI wire including hoisting & binding etc. Complete as required.
Erection of 9 KV, 5KA Gapless Silicon Polymeric Lightning Arrestors
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Carriage of 11/0.430, 3-Phase 63KVA Transformer -15 nos. by Mechanical Transport from AD Nagar Store sub-division, Agartala to working site Vis-a-vis including loading, unloading and placing on base, as required,
Installation/Positioning of 11/0.430KV,3-Phase 63KVA Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
Erection of shackle insulator of size 75mm x 90mm /100mm x 15mm with straps & bolts/U clamp on poles ( Excluding the cost of cost of straps/ U Clamp, Nuts & Bolts)
Earthing with G.I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, Gi wire, nuts &bolts, etc. as required)
Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves .
Febrication of different sizes Cross-Arms by MS Channel/MS Angle as per specification
Erection of 11KV protective Guarding by GI wire 8 SWG as per technical specification,across road/River/Telecom line etc. in horizonta formation complete .
Dismantle
Dismantling of 7.5mtrs & 8Mtr. length of P.C.C POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect
Dismantling of 9.0mtrs length of P.C.C POLE at any kind of soil including excavation of earth, refilling the pit with with soil upto the ground level, ramming and making complete in all respect.
Dismantling of 7.0mtrs,8mtrs & 9mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Dismantling of Stay set from the earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. and making complete in all respect.
Dismantling of M.S.Angle Cross-Arm,1.0 to 1.6 Mtr. Long 65 x65 x 6 mm
Dismantling of M.S.Channel Cross-Arm,0.3 to 1.6 Mtr. Long75 x40 x 40 x 6 mm
Dismantling of M.S.Channel Cross-Arm,2.2 to 2.8 Mtr. Long75 x40 x 40 x 6 mm
Dismantling of shackle insulator of size 75mm x 90mm /100mm x 15mm with straps & bolts/U clamp on poles
Dismantling of 11KV Pin insulator along with Pin.
Dismantling of 11KV Single Disc insulator set along with necessary fittings.
Dismantling of (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including Coiling etc. Complete as required.
Dismentaling & re-fixing of 1-Ph PVC Cable Service Connection
Dismentaling & re-fixing of 3-Ph PVC Cable Service Connection
Re-stringing of all size of ACSR/AAC/AASC in/c. oppenning of binding , jumpering etc.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tendernotice_2.pdf
PDF • 2.26 MB
BOQ_69230.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid