Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.6 L+₹1.3 L (5.75%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹25.4 L+₹2.2 L (9.29%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L-4₹27.6 L+₹4.3 L (18.3%)Rejected-AOC | L-4 | Rejected-AOC Rejected | |
| 5 | L5₹46.9 L+₹23.6 L (101.3%)Rejected-AOC 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS C o 56 APO
PROVN OF LLDPE SEPTIC TANKS AT VARIOUS LOCATIONS AT INF BN AND PVC WATER STORAGE TANKS FOR COMN COMPLEX AT GULMARG UNDER GE 969 EWS
2020_MES_405942_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Gulmarg
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹48,000
Yes
15 Mar 2021
22 Dec 2020
20 Jan 2021
22 Dec 2020
18 Jan 2021
5 Jan 2021
60 days
Amount
LLDPE Septic tank exc inordinary soil foundation in PCC 1:2:4 brick work in CM 1:4 RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all arround/fiber reiforced cover with angle iron frame vent shaft and sludge chamber etc complete for 20 users. Complete all as specified and shown in drg No.CESZ/TD-1080/2011
Soakage well exc. in ordinary soil foundation in PCC 1:3:6 well of honey combed and solid in M-25 concrete including intercepting chamber screen chamber brick work in 1:4 cm, RCC cover slab in M-25/RR masonary /filling with brick bats, complete of size 2.40 m dia x 3.00 m deep. Complete all as specified and shown in drg No.CESZ/TD-1078/2011
Cutting into existing manholes for connecting new drains pipe making good to pipes rendering cutting out existing benching for & forming branch channel (1/2 round of ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required internal dia of pipe 150 mm dia. Complete all as specified and directed by Eng-In-Charge.
Excavation in trenches in any type of soil, n exc 1.5 M wide and n exc 1.5 M deep for foundation, etc or for shafts, wells, manholes, laying of cable/pipe etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete. Complete all as specified and directed by Eng-In-Charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone agg in foundation and mass concrete. Complete all as specified and directed by Eng-In-Charge.
M&L for precast cement concrete block masonry with hollow blocks type C-1 , 1:3:6 (using 16mm graded stone aggregate) masonry exc. 10cm in width and setting in cement mortar 1: 4. Complete all as specified and directed by Eng-In-Charge.
M & L for 1:2:4 types B-1 (using 20 mm graded stone agg as in coping etc. Complete all as specified and directed by Eng-In-Charge.
M&L for PCC 1:2:4 type B-2 (40 mm graded aggregate) in walls or retaining walls any thickenss, size or shape including pilaster, buttresses columns, pillars, boundary and posts. Complete all as specified and directed by Eng-In-Charge.
M&L for 150 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars. Complete all as specified and directed by Eng-In-Charge.
M&L for concrete bed to drain pipes in PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate including packing under haunching against the sides of pipe after they are laid and tested for 150mm dia. Complete all as specified and directed by Eng-In-Charge.
Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm. Complete all as specified and directed by Eng-In-Charge.
Removing excavated materials n exc 50M and depositing where directed at a level n exc 1.5 M above the starting point. Complete all as specified and directed by Eng-In-Charge.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with WPC, finished even and smooth complete.Complete all as specified and directed by Eng-In-Charge. Note: (WPC shall be measured and paid separately).
M&L for for rendering 15mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth complete. Complete all as specified and directed by Eng-In-Charge.
Supply only integral water proofing compound. Complete all as specified and directed by Eng-In-Charge.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc. Complete all as specified and directed by Eng-In-Charge.
Extra for forming fair faces (finished) drain of channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitered stopped end etc Complete all as specified and directed by Eng-In-Charge.
S&F mild steel TMT bars 8 mm dia, quality conforming to Grade 415 MPA cut to length , bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia. Complete all as specified and directed by Eng-In-Charge.
S&F Rolled mild steel in joist channel, angle(size 50x50 x 6 mm th), or tee sections fixed independly, without connecting plates, etc (cut to ordinary length) of Fe 410w (Gde E250) gde A supplied and fixed complete.
S&F mild steel TMTbars 10 mm dia over, cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
M & L for precast RCC man holes cover in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate. Complete all as specified and directed by Eng-In-Charge.
Surface excavation n. exc. (Not Exceeding) 30 Cm deep and averaging 15cm deep and getting out hard dense soil. Complete all as specified and directed by Eng-In-Charge.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil.
M&L for cement concrete in foundations type D-2 1:4:8 (40mm graded aggregate) filling and mass concrete. Complete all as specified and directed by Eng-In-Charge.
S&F 2000 ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position. Complete all as specified and directed by Eng-In-Charge.
S&F compound girders and stanchions, lattic girders aerial masts, staging for watrer tanks and the like including caps, bases, splices etc. Built up from two or more beam or channel sections or angles with plates including all lattic bars, stiffensers, gusset plates, etc. conforming to Fe-290(Gde-E-165). Complete all as specified and directed by Eng-In-Charge.
M&L for precast cement concrete block masonry with hollow blocks type C1 , 1:3:6 (using 20mm graded stone aggregate) masonry exc. 10cm in width and setting in cement mortar 1:6. Complete all as specified and directed by Eng-In-Charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement. Complete all as specified and directed by Eng-In-Charge.
M & L for broken stone or boulders for hard core of gauge n exc 63mm deposited spread and leveled in layers 15 cm thick watered and rammed to true surface. Complete all as specified and directed by Eng-In-Charge.
M&L for 100 mm thick Cement concrete type B 1, 1:2:4 (using 20 mm graded aggregate) as in flooring and finishing cement concrete surface even and smooth without using extra cement etc complete all as specified.
Forming contraction dummy joint of 65mm deep x 10mm wide filled with sealing compound of grade 'A'. Complete all as specified and directed by Eng-In-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
M&L for sand cushioning to underground electric cable all as per clause 19.75 of SSR Part-I. Complete all as specified and directed by Eng-In-Charge.
M&L for sub class 'B' common kiln burnt clay building bricks, old size 230mmx115mmx75mm, laid at right angle along the cable over sand cushioning, as cable protection, Complete all as specified and directed by Eng-In-Charge.
Supply & Fixing 50 mm dia bore, 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply will sustain - 250C, all PP-R plain & brass threaded polypropylene random fittings laid in trenches. Complete all as specified and directed by Eng-In-Charge.
All as per item no.35 above but 40 mm dia bore.
All as per item no.35 above but 25 mm dia bore
All as per item no.35 above but 20 mm dia bore
Supply and fixing 50 mm dia PPR Gate Valves (Brass Insert) for GI pipes. Complete all as specified and directed by Eng-In-Charge.
All as per item no.39 above but 40 mm dia
All as per item no.39 above but 25 mm dia
All as per item no.39 above but 20 mm dia
Cutting of existing GI pipe line of size 50/40/25/20 mm dia and inserting new pipe line including all fittings. Complete all as specified and directed by Eng-In-Charge.
Supply, installation, commissioning and testing of Centrifugal Mono block pump, electric driven, 2 HP CM Series complete all as specified and directed by Engr-in-charge. Make:- Havelles (Product code - MHPRCA2X00 Model - CMJ20) or its equivalent as approved.
supply and fixing of 2 HP DOL Starter suitable for centrifugal mono block pump complete all as specified and directed by Engr-in-charge. Make :- Havells (Cat No. IHADOAG1) or equivalent as approved.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for flooring, paving and roads etc Complete all as specified and directed by Eng-In-Charge.
M&L for MS tubes, light grade, galvanised, 80 mm bore, laid in trenches or under floor or road for protection of PPR pipes in road crossing. Complete all as specified and directed by Eng-In-Charge.
M&L for PCC 1:3:6 type C-2 conc bed using 40mm graded stone agg to drain pipe including packing under & haunching against the sides of pipe 100 mm dia ( internal) after these are laid in trenches. Complete all as specified and directed by Eng-In-Charge.
M&L for cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less etc.
M/s Riyaz Enterprises
M/S ALI MOHAMMAD GASSI
Javeed And Co
RAMESH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .