THE EXECUTIVE ENGINEER TLMD 3RD AMARGARH
OFFICE OF THE EXECUTIVE ENGINEER TLMD 3RD AMARGARH
SUPPLY INSTALLATION TESTING AND COMMISSIONING OF HIGH MAST LIGHTING SYSTEM INSTALLATION OF CCTV SURVEILLANCE SYSTEM AND OTHER ALLIED ELECTRICAL CIVIL WORKS AT 132 BY 33 KV GRID STATION PATTAN
2021_PDD_131981_1
EE/TLMDA/19 OF 2021
Open Tender
Electrical Works
Turn-key
30 days
GRID STATION PATTAN
AS PER SBD
6 documents required · 6 mandatory
₹500
THE EXECUTIVE ENGINEER TLMD 3RD AMARGARH
Exempted
6 Oct 2021
27 Jul 2021
11 Sept 2021
27 Jul 2021
9 Sept 2021
2 Aug 2021
27 Jul 2021 - 2 Aug 2021
Amount
SITC of High Mast Lighting System in outdoor yard of Grid Station Pattan
Providing and erecting 20mt High Mast Lighting sytem suitable to install upto 9 No. 200/400W LED flood light and control gear with integral Power tool, weight 450 kg. comprising of 2 sections of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm & 4 mm, dia 150mm & 360mm for top and bottom respectively, stress fitting arrangement on site with 500mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part III, parameters for structural & foundation design must be taken from Wind Tunnel test. Lightning protection of GI single spike 1200mm at top and at base inside compartment having double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 520mm dia. and foundation bolts having 8 nos. bolts of 24mm dia 750 mm long (EN.8 grade) Anchor plate 445 PCD, including accessories viz. (1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable to carry 500kg. load and upto 9 fittings symmetrically. (2) Double Drum 350Kg Winch having gear 53:1, oil bath (SAE90/140) arrangement. (3) 2 nos. Stainless steel wire ropes 5 mm dia (7/19) breaking load capacity 1450 kg x 2, (4) Integral power tool 3-phase, 0.75HP 2m/min single speed .torque limiter up to 500 kg adjustable. (5) Foundation drawing, test certificate and gurantee certificate shall be provided by manufacturer.
Supplying, fixing & testing of approved make LED. asymmetrical / symmetrical beam flood light fitting suitable for tubular single lamp consisting of cast aluminium housing aluminium faceted reflector assly toughned glass cover, mounting bracket and aiming disc, seperate controlgear box required for HPSV/M.H. Lamp (without lamp) including fixing & connection as required in position with allnecessary material requiredSupplying, fixing & testing of approved make LED asymmetrical / symmetrical beam flood light fitting suitablefor tubular single lamp consisting of cast aluminium housing aluminium faceted reflector assly toughned glasscover, mounting bracket and aiming disc, seperate control gear box required for LED including fixing & connection as required in position with all necessary material requiredSupplying, fixing & testing of approved make LED asymmetrical / symmetrical beam flood light fitting suitable for tubular single lamp consisting of cast aluminium housing aluminium faceted reflector assly toughned glass cover, mounting bracket and aiming disc, seperate control gear box required for HPSV/M.H. Lamp (without lamp) including fixing & connection as required in position with all necessary material require.The Outdoor Type LED Flood Light Fixture LED(High Efficiency) of Philips/Wipro/Crompton) 200 Wattage each assembled on single MCPCB, having color temp 4000/6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum in the efficacy>80lm/W. LED driver, PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than Ra> 80. Housing made of CRCA coated with glare free diffused polycarbonate cover. Electronic In-Built PF > .9 , THD < 10% , IEC Compliant for Safety , Performance & EMI Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.Mains Voltage:170-240V , 50 / 60Hz Colour :Cool White Lamp efficiency(%):90%. IP rating: IP65- 9Nox200W LED Flood Light including wiring with 2x2.5mm2 complete from Feeder Light Panel to Light Fixture.
Supplying and fixing of LT Panel and its accessories including connections etc.as required as per spececification: Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming 3 No. MCB 32 A TPN switches, 3 No. 10A DP MCBs, HRC fuses, single dial analog timer, suitable size of contactors for lighting and power tool, 2 nos.outgoing, reversing switch for motor, Cu. Busbar strip of suitable size, 2 No LED Indicators
Supply and laying in cable clamped to wall with suitable clamps saddles and fixing bolts/ in ground including the cost of digging and back filling with sand and brick protection as required and including testing and commissioning of the following sizes of 1.1KV grade multicore aluminium conductor PVC insulated and PVC sheathed armoured cable conforming to IS : 7098 (Part-I). The costs shall include for all cables to be provided with a 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables and route markers for cables in ground as per specifications and as per instructions of Engineer- in-charge. 4Core X 16 mm2 Armoured PVC Aluminum cable
Trailing Copper cable 4x6 sq.mm, PVC insulated PVC Sheathed
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.: 4 X 16 sq. mm (28mm)
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required :63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying,installation,testing and commissioning of Astronomical Time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise ortwilight (Auto ON, Auto OFF, Auto modes) with manual overridefacility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required: 3 output (1 output per phase) and suitable for three phase supply
Spares: Supply LED Flood Lights of specifications mentioned at S.No.4 above.
CIVIL WORKS
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : Foundation (2.5x2.5x1.4)=8.75 cum, Cable trunch (15mx0.5mx0.5m)=2.75cum
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)=(2.5x2.5x0.1)=.625 cum
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) Section A:(2x2x0.4)=1.6 cum; Section B (1x1x1.1)=1.1 cum ,total =2.7 cum
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. Section A =4x2x0.4=3.2sqm section B=4x1x1.1=4.4sqm;total =7.6 sqm
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Mild steel and medium tensile steel bars
CARRIAGE OF MATERIALS:By Manual Labour including loading, unloading and stacking A) Cement (5km) = 11.8625 qntl @15.94= RS 189 B) Agg> 40mm(20km) =2.82 cum @ 349.82= Rs 987 C) Sand (20km)=1.454 cum @ 349.82=Rs 509 ;Total carriage = Rs 1685
Providing And fixing of Foundation bolts (M 24 ,750mm long ) with Base plate (570dia x 30THK) and Anchor plate.
Back filling and other miscellaneous items
Installation of CCTV Surveillance System at 132/33KV Grid Sub-Station Pattan
55’’ LED TV: Display: Screen type SLED ; screen size 139cm (55"); Screen resolution 3840 x 2160; Display colors 1.07G Colors; Screen ratio 16:9; Screen viewing angle 178°; Picture processor MediaTek 64-bit Quad-core Processor; Picture technology Chroma Boost. Audio: Sound output 24W; Speaker configuration 4 units; Dolby audio ;Yes; Infrared Support; Remote control; HDMI three; AV one; Tuner two; USB two; Audio out COAX. Power supply: Voltage 90V-240V 50HZ ; Operating temperature -40~60℃; Passive standby power ≤0.50W; Humidity < 80%; Power Consumption 170W; Relative humidity <90%.
IP CCTV Camera 4MP: Image Sensor 1/3" progressive scan CMOS; Min. Illumination - Color: 0.01 Lux @(F1.2, AGC ON), 0.028Lux @ (F2.0, AGC ON); Shutter Speed 1/3 s to 1/100, 000 s; Slow Shutter - Yes; Auto-Iris - No; Day & Night IR cut filter; Digital Noise Reduction 3D DNR; WDR 120 dB; Angle Adjustment Pan: 0° to 355°, tilt: 0° to 70°; Focal Length 2.8 mm, 4 mm, 6 mm; Aperture F2.0; Focus - No; FOV 2.8 mm, horizontal FOV 100°, vertical FOV 55°, diagonal FOV 117°; 4 mm, horizontal FOV 77°, vertical FOV 42°, diagonal FOV 88° 6 mm, horizontal FOV 51°, vertical FOV 28°, diagonal FOV 58°; Lens Mount M12 IR; IR Range Up to 40 m; Operating Conditions -30 °C to 50 °C (-22 °F to 122 °F), humidity: 95% or less (non-condensing); Power Supply 12 VDC ± 25%, 5.5 mm coaxial power plug; PoE (802.3af, class 3) Power Consumption and Current; 12 VDC, 0.4 A, Max: 5 W; PoE: (802.3af, 36 V to 57 V), 0.2 A to 0.13 A, Max: 7 W.
CAT 6 Cable (LAN cable) Category : 6 UTP Solid cable; Conductor : 23 AWG (Solid); Conductor Meta : Bare Copper; Insulation Material : HD-PE; OD : 6.1mm ±0.2; Resistance Unbalance : 5% Max; Capacitance Unbalance : 330pF/100m; Delay Skew : <45nS
POE Switch Port Number: 8 × gigabit RJ45 ports; Port TypeRJ45 port, full duplex, MDI/MDI-X adaptive; Working Mode - Standard mode (default); StandardIEEE 802.3, IEEE 802.3u, IEEE 802.3x, and IEEE 802.3ab; Forwarding ModeStore-and-forward switching MAC Address Table4 K; Internal Cache1.5 Mbits; Switching Capacity16 Gbps; Packet Forwarding Rate11.904 Mpps. Operation Management :- Device Maintenance Support remote upgrade, recovering default parameters, viewing logs, configuring basic network parameters. Port ConfigurationSupport rate, flow control, and switch configuration General Dimension (W × H × D)170 mm × 27.6 mm × 93.1 mm (6.69” × 1.09” × 3.67”); Storage Temperature-40°C to 85°C (-40°F to 185°F); Power Source5 W; Gross Weight0.36 kg (0.79 lb); Power Consumption in Idle5 W; ShellMetal material, fan-free design; Operating Temperature0°C to 40°C (32°F to 104°F); Operating Humidity5% to 95% (no condensation); Power Supply5 VDC, 1 A; Max. Power Consumption5 W; Relative Humidity5% to 95% (no condensation).
NVR 16 Channel Video and Audio IP Video Input16-ch HDMI Output 4K (3840 × 2160)/30Hz, 2K (2560 × 1440)/60Hz, 1920 × 1080/60Hz, 1600 × 1200/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz VGA Output1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz Incoming Bandwidth160 Mbps Audio Output1-ch, RCA (Linear, 1 KΩ) Two-Way Audio1-ch, RCA (2.0 Vp-p, 1kΩ). Network Protocol. TCP/IP, DHCP, IPv4, Hik-Connect, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, NFS, iSCSI, ISUP, UPnP™, HTTP, HTTPS; Network Interface1, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface RAID Type -No Auxiliary Interface: SATA2 SATA interfaces; CapacityUp to 6 TB capacity for each HDD; USB InterfaceFront panel: 1 × USB 2.0; Rear panel: 1 × USB 3.0; Alarm In/Out4/1 Power Supply: 12 VDC; Consumption≤15 W; Working Temperature-10 °C to 55 °C (14 °F to 131 °F); Working Humidity10 to 90 %; Dimension (W × D × H)385 × 315× 52 mm (15.2" × 12.4" × 2.0") ≤ 1 kg (2.2 lb).
4TB Surveillance HDD
2 Core Cable 1.5 SQMM
HDPE Conduit for cable laying
SITC & Replacement of OTIs, WTIs, MKs & Cooling Fans
Supply, installation and commissioning of by way of replacement old / damaged / malfunctioning OTI with fresh one with the following specifications: Mercury contact type switches with 150mm dial for top iol temperature indication. The switches shall have adjustable electrically independent potential free alarm and trip contacts. Maximum reading (150 degree centigrade) and resetting device shall be mounted in the local control panel. A temperature sensing element suitable located in a pocket on top oil shall be furnished. This shall be connected to OTI by means of capillary tubing. Accuracy class of OTI shall be 1% or better. Mercury switches for Alarm, Trip Contacts capable of operating at 10A DC at 110V supply.
Supply, installation and commissioning of by way of replacement old / damaged / malfunctioning WTI with fresh one with the following specifications: Shall be provided with temperature sensing element , mercury contact type switches, 150mm dial indicating instrument with maximum reading (150 degree centigrade) pointer mounted in local panel and with adjustable electrically independent contacts , besides that required for control of cooling fans, high winding temperature alarm, trip, pump system, four no. electrical contacts each capable of operating at 1A DC at 110V supply.
Supply, installation and commissioning of by way of replacement of damaged/non functional cooling fan-motor assembly with fresh ones with the following specifications: 600 watt, 415 Volt, 3-Phase, 50 Hz, 700 rpm, 24" sweep with 'F' Type insulation and meant for continuous duty.
Improvement of yard Marshalling Kiosk in all respects including replacement of TBs, thimbles, cable glands, refixing of cables and repairing/replacement of Doors with Lock and painting (complete job).
M/S POWER STARS
M/S YATOO ELECTRICALS
M/S A M ELECTRICAL AND MECHANICAL ENGINEER
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .