| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L1 | Accepted-Finance L1 Lowest Quoted Rate | |
| 2 | L2₹2.0 L+₹2,401.46 (1.21%)Rejected-Finance | L2 | Rejected-Finance L2 Highest Quoted Rate | |
| 3 | L3₹2.0 L+₹2,991.46 (1.50%)Rejected-Finance | L3 | Rejected-Finance L3 Highest Quoted Rate |
| Sl No | Description | Qty | Unit | PARAMALINGAM L2 | R SURESH L3 | S MURUGANANTHAM L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing Flushing and Deepening for Existing Borewell Near E.Batherpettai Arumugam Asari House in E.Batherpettai Panchayat.
Rate for flushing of borewell of 6” dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by ‘V’ notch method if required | 4 | Hours | 2,201.2 ₹8,804.8 Lowest | 2,201.2 ₹8,804.8 Lowest | 2,403 ₹9,612 |
| 2.00 | Drilling of 150mm dia borewell in hard rock areas anywhere in tamilnadu including transportation to the worksite in hardrock areas and developing the borewell | 60 | Mtr | 329 ₹19,740 | 329 ₹19,740 | 300 ₹18,000 Lowest |
| 3.00 | Bore cap using M.S. Flat of size 1 cm x 3 mm and M.S. sheet on top with bolting arrangements for securing the cap in position | 1 | Nos | 717.11 ₹717.11 | 717.11 ₹717.11 | 500 ₹500 Lowest |
| 4.00 | Supply and delivery of 7.50 Hp Three phase per isi 100lpm x 175 m head | 1 | Nos | 68,348 ₹68,348 | 68,348 ₹68,348 | 65,000 ₹65,000 Lowest |
| 5.00 | Control panel board Consist of following 1.voltmeter&ammeter suitable for above pumpset | 1 | Nos | 21,187 ₹21,187 Lowest | 21,187 ₹21,187 Lowest | 21,187 ₹21,187 Lowest |
| 6.00 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of
panel board consisting of TPICN switches starter,
Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete | 1 | Nos | 15,721.5 ₹15,721.5 Lowest | 15,721.5 ₹15,721.5 Lowest | 15,722 ₹15,722 |
| 7.00 | 4.0 sqmm sub flat cable (3 core copper cable) | 60 | Mtr | 221.7 ₹13,302 | 221.7 ₹13,302 | 220 ₹13,200 Lowest |
| 8.00 | 50 mm Upvc Pipe | 60 | Mtr | 312 ₹18,720 | 312 ₹18,720 | 285 ₹17,100 Lowest |
| 9.00 | 50 mm MS clampset | 1 | Nos | 256.5 ₹256.5 Lowest | 256.5 ₹256.5 Lowest | 256.5 ₹256.5 Lowest |
| 10.00 | 50 mm GM Non Return Valve | 1 | Nos | 2,703 ₹2,703 Lowest | 2,703 ₹2,703 Lowest | 2,703 ₹2,703 Lowest |
Tender Value
₹2.0 L
EMD Value
₹2,050
Closing Date
11 Sept 2026, 3:00 pmClosed
block development officer (bpts)
block development officer (bpts)
Providing Flushing and Deepening for Existing Borewell Near E.Batherpettai Arumugam Asari House in E.Batherpettai Panchayat.
2026_RDTN_701159_2
A2/2422/2026-1
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
Item Wise
30 days
uppiliyapuram
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2,050
Yes
12 Sept 2026
3 Sept 2026
11 Sept 2026
3 Sept 2026
11 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing Flushing and Deepening for Existing Borewell Near E.Batherpettai Arumugam Asari House in E.Batherpettai Panchayat.
Rate for flushing of borewell of 6” dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by ‘V’ notch method if required | 4 | Hours | - | - |
| 2 | Drilling of 150mm dia borewell in hard rock areas anywhere in tamilnadu including transportation to the worksite in hardrock areas and developing the borewell | 60 | Mtr | - | - |
| 3 | Bore cap using M.S. Flat of size 1 cm x 3 mm and M.S. sheet on top with bolting arrangements for securing the cap in position | 1 | Nos | - | - |
| 4 | Supply and delivery of 7.50 Hp Three phase per isi 100lpm x 175 m head | 1 | Nos | - | - |
| 5 | Control panel board Consist of following 1.voltmeter&ammeter suitable for above pumpset | 1 | Nos | - | - |
| 6 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of
panel board consisting of TPICN switches starter,
Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete | 1 | Nos | - | - |
| 7 | 4.0 sqmm sub flat cable (3 core copper cable) | 60 | Mtr | - | - |
| 8 | 50 mm Upvc Pipe | 60 | Mtr | - | - |
| 9 | 50 mm MS clampset | 1 | Nos | - | - |
| 10 | 50 mm GM Non Return Valve | 1 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.83 MB
Technicalbid.pdf
Tender Documents • 0.80 MB
BOQ_842760.xls
BOQ • 0.28 MB
Pricebid.pdf
Additional Documents • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .