S&T work in connection with the interlocking of 4 nos. of LC gates in the section of SSE/Signal/BQA in Adra Division.
SnT_e_Tender_ADA_26_27_19
SnT_e_Tender_ADA_26_27_19
Open
12 Months
Purulia, West Bengal
₹0
₹5.6 L
16 Jun 2026
16 Jun 2026
26 Jun 2026
Supply, transportation & installation of Power Terminal 100 Amps. Inspection: Representative of Sr.DSTE/Adra.
Trenching for searching of faulty cable position which was laid at a depth of 01 Mtr.Excacvation of earth to be done 1 Mtr. x 0.3 Mtr. This includes refillng of excavated soil.
For searching of faulty cable joint position/faulty position of cable joint cum testing pit tobe excavated at a size of 1 M x1M x 1M & after completing the job refilling to be done.
Supply & Fixing of 63 Amp DPDT Main Switch including whether proof MS cover. Inspection: Representative of Sr.DSTE/Adra. Above/
Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 2 10262- 2019 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting (1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. Inspection: Representative of Sr.DSTE/Adra.
Cutting and smoothening of inside surface of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick 3 placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 Note: Sundries materials such as Bricks, sand, cement etc., shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase. Note: In case, chase cutting & smoothening are other than prescribed depth & width, Proportionate payment shall be released.
"Cutting the masonry wall to the depth of 0.25m to 0.75m at the entry of room, placing of flexible HDPE pipe as per the instructions of Railway site-in-charge and repairing of 4 masonry wall and cement plastering after the cable is taken inside the flexible HDPE/GI pipe (to be supplied by Railway) of suitable diameter with Clamps. The supply of Clamps, masonry materials etc. are to be supplied by the contractor. Note: Unit in no. denotes as number of entry point which is required during course of cable insertion."
Mechanised Drilling/Micro Tunnelling under important/ busy metal/concrete road/Railway track and laying of GI pipe including supply (make: TATA/Jindal or better) of min. 5 75mm inner diameter Grade Medium with Spec. No. IS- 1239, Pt-1, 2004 including supply, Boring and pulling cable upto 110mm dia. at a depth of min. 1 meter as per site condition. This also includes reinstatement of the surface to the original state. Inspection: Representative of Sr.DSTE/Adra.
Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. Track/ Pucca road/Platform crossing/ Level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of 6 DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830 (Part-2):2001 as per SEM Drawing No. 15-D4 and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of Platform/Pucca road after cable laying. Inspection: Representative of Sr.DSTE/Adra.
Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 metre. Track/Pucca road/Platform crossing/Level crossing as per SEM Drawing No.15-D5 or latest including supply, transportation and laying of RCC Pipes (full) with collar (for jointing pipes) Inner diameter/Outer diameter: 7 100mm/150mm to Specification No. IS:10262-2019 or latest and IS-456-2000. RCC structural drawings should be as per SEM Drawing No. 15-D3 (Sheet-2) and drawing of cable through RCC Pipes with collar (for jointing pipes) including back filling and ramming after cable laying as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of platform/pucca road after cable laying. Inspection: Representative of Sr.DSTE/Adra.
Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS:1239, Pt- 1, 2004 thickness 3.2 mm medium grade and fixing on girder bridges as per Drawing No. 8 CON/SK/T/4 or latest including supply and transportation of channel, angle, iron brackets, Steel Nuts and bolts with hole, split pin of proper size for fixing of trough etc. as per above drawings including drawing of cables inside the pipe with masonry work at bridge entry and exit of the Bridge and curing for 72 hours and pipes are to be clamped at max. 1.5 meter apart for S&T Cables. Inspection: Representative of Sr.DSTE/Adra. Note: This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store.
Transportation and laying including supply of Split RCC pipe as per Spec. No. IS: 10262-2019 or latest and IS-456- 2000 & SEM Drawing No.15-D3 having plain ends with their jointing loose split collar half round of size 200 mm (inner diameter)/25mm thickness at site over the single/multiple cable laid in the trench.
Supply, transportation and fixing of RCC Cable Route Marker as per SEM drawing No. 15-D1 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of 10 Pair, 0.63 mm diameter Underground Polythene insulated polythene sheathed jelly filled telephone cable as per Specification No. IRS:TC:41/97 Amd.3.0 or latest. Inspection: Representative of Sr.DSTE/Adra.
Transportation of cables in rolls with or without wooden drums (S&T Cables) from 12 concerned store to the site of works. Note: The unit Drum-KM indicates Drum X length of cable in that drum. It doesn't have any significance over the distance it has to be carried for execution of the work. For illustration - 1 Drum having 1Km of cable when transported for any distance will be paid this amount.
"Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest 13 punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports."
"Supply of Control cum Indication panel Domino Type at Mid-section interlocked LC Gate/IBS/Siding motor operated point operation panel /Non-Interlocking panel of third line section as per RDSO Specification No. RDSO/SPN/186/2004Rev. 2.0 or latest. Size of each Domino will be 54 x 14 34 mm2. Control Panel includes panel rest, front and side table, complete with switches, push button, termination of cables, painting and lettering as required. This also includes 10% spare of panel LED's, Dominos and button assemblies, counter, keys, buzzer etc. Inspection: Representative of Sr.DSTE/Adra. Note: Size of the panel will depend upon the number of Dominos required as per Front Plate Diagram.
Installation, wiring, testing and commissioning of the Control cum Indication panel type Mid-section interlocked LC Gate/IBS/Siding motor operated point operation panel /Non- Interlocking panel of third line section as per approved interlocking plan, FPD, circuit diagram etc.
Supply of 200/160 way Tag block with PVC covers as per Specification No. IRS: S- 77/2006 with Rev.1.0 or latest & Drawing No. SA-24751 & 52 or latest. Inspection: Representative of Sr.DSTE/Adra.
Fixing, wiring & soldering of 200/160 way tag blocks as per IRS:S-77/2006 (Rev.1) or latest on SM panel Domino/cable termination rack/relay rack/block rack etc. as per instruction of site engineer.
"Supply of Remote terminal unit (RTU) with 128 Digital & 16 Analog inputs with E1/64 Kbps Voice Channel/Optical modem as per Specification No. IRS:S-99/2006 (Amdt-3) or latest. 18 Magnetic door lock coil to be supplied along with equipment. Inspection: RDSO. Note: i) The contractor is required to confirm the required modem to meet the site requirement before placing an order to any RDSO approved OEM from Engineer in charge. ii) The inspection of E1/Optical Modem shall be done by consignee."
Installation, Wiring, Testing, Validation and commissioning of Remote terminal unit with 128 Digital & 16 Analog inputs with modem as per Specification No. IRS:S-99/2006 (Amdt-3) or latest.
Supply of Electric key transmitter (EKT)/Rotary key transmitter (RKT) as per Specification No. IRS:S-21/2001 Rev 1.0 or latest & Drawing No.SA-22601 or latest with the keys and wards nos. will be per instructions given by site Engineer in charge. Inspection: RDSO.
Transportation, installation and wiring of Rotary key transmitters/KLCR on Hylam 21 sheet board including wiring & fixing of push button bell switch on Hylam sheet of 12mm including termination, painting & lettering. The sundry materials such as Hylam sheet, push bell switch etc. to be supplied by contractor.
Supply and Installation of Glass fronted Key box made of water resistant Engineered 22 wood for Rotary key transmitter (RKT)/EKT/KLCR/SM's key box of appropriate size etc. with locking arrangement and 1 no. of Godrej make padlock. it should be done as per site supervisor instructions. After installation it should be painted and letter writing as per SER practice. Inspection: Representative of Sr.DSTE/Adra.
Supply of Steel Apparatus case Full height as per Drawing No. SK/Drg./OL/SER /198 or 23 latest with E type lock . E- type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S-10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one. Inspection: Representative of Sr.DSTE/Adra.
"Execution of Full Apparatus Case with earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. Con/SK/T/8 or latest and wiring to be done as per SEM Drawing No.19-D8 or as per direction of site engineer. Supply and fixing of Hylam sheet strip of appropriate size of 3 mm or 6 mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, proper soldering of cable armour with earth catenary wire, earthing of cable armour as required. Writing & terminal description including 24 Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nut & bolts, sand for filling up cable pit inside the apparatus case including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%."
Supply of 25 mm thick Hylam Sheet of size 955mm x 400mm per specification no. IS 2036 of 1995 or latest. Note:- In case the requirements are different from the above, proportionate payment will be done. Inspection: Representative of Sr.DSTE/Adra.
Supply of Earth Electrode as per Drawing No. 19-D6 of SEM-2021 or latest. GI pipe 26 confirming to IS:1239 or latest of 3.17 mm thickness, minimum 2.5 m long, 50.8 mm diameter, 4.76 mm diameter drilled holes staggered at distance of 152.4 mm. Inspection: Representative of Sr.DSTE/Adra.
Excavation of earth pit, placing & fixing of Earth electrode with construction of cement enclosure to SEM Drawing No. 19-D6 and drawl of 6 SWG GI/Copper cable from earth 27 electrode to goomties/relay room/cabin/station, etc. and drawl of MS flat 35mm x 6mm for signal post/Location box shall be used as the case may be, including fixing at both ends of the wire/MS flat. This includes transportation of materials. Note: Materials such as charcoals, salt, sal ammoniac, 6 SWG GI wire, copper lugs with Steel bolts & nuts etc. shall be supplied by the contractor. MS flat 35mm x 6mm/Copper cable shall be supplied by Railway.
Supply of 35 mm x 6 mm thick MS Flat Plate Strip as per IS: 226-1975 or latest for earth connection to Signal post, L/Box etc. Inspection: Representative of Sr.DSTE/Adra.
"Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. Inspection: RDSO.
"Supply of basic material to construct Maintenance Free Earth for Ring Earth consisting as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/RDSO/E&B/002 or latest. (a) Copper bonded steel electrodes of 3.0 m long, 17.0 30 mm dia. minimum with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No. (d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No. (e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. Inspection: RDSO.
Installation of Single Maintenance Free Earth pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following, a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape 31 of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer.
Supply of PVC insulated 10 Sq. mm Single core Multi strands copper conductor as per Specification No. IRS:S-76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in- Charge. Inspection: Representative of Sr.DSTE/Adra.
Routing and connecting of all the equipment in the equipment/relay room to SEEB 33 with 10 sq. mm copper cable using copper lugs with stainless steel nut and bolts and fixtures. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway.
Supply of PVC insulated 16 Sq. mm Single core Multi- strands copper conductor as per Specification No. IRS:S-76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in- Charge. Inspection: Representative of Sr.DSTE/Adra.
Routing and connecting of all the SPDs in the equipment room/SEEB to MEEB with 16 35 sq. mm copper cable using copper lugs with stainless steel nut and bolts. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway.
Supply of PVC insulated 35 Sq. mm Single core Multi- strands copper conductor as per Specification No. IRS:S-76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in- Charge. Inspection: Representative of Sr.DSTE/Adra.
Digging a trench to a depth of at least 0.5 meter and run the two 35 sq. mm earth 37 conductor in protective PVC conduit pipe, procured against supply item, from Earth pit to MEEB. Routing and exothermic termination of two 35 sq. mm cable on earth conductors as well as on 300 mm X 25 mm X 6mm MEEB, which is to be fixed inside the equipment room with two 60mm insulation studs. The 60mm insulation studs have also to be supplied.
Supply of Earth Leakage Detector (ELD) - 4 channels as per Specification No. RDSO/SPN/ 256/2002 or latest. Inspection: RDSO.
Fabrication of stand/rack, installation, testing & commissioning of Earth Leakage Detector (ELD) - 4 channels as per Specification No. RDSO/SPN/ 256/2002 or latest.
Supply of 20 Pair CT box made of 16 SWG CRC sheet with disconnection and 40 reconnection (wago type). The CT Box should be grey colour powder coated with terminal, washer, nut & bolt should be of brass. There shall also be locking arrangement. Inspection: Representative of Sr.DSTE/Adra.
"Transportation and fixing of following types of C.T. Box (Aluminium/Wago type) and termination of cable as per details of jointing schedule approved by the Railway Engineers. 20 pair C.T. Box/Krone type DP Box"
Supply of Composite/Q series Relay Rack as per Drawing No. SK/DRG/OL/SER/192, Sheet 1 and 2 or latest and must be powder coated of stone grey colour. Inspection: Representative of Sr.DSTE/Adra.
Transportation, Grouting/Erection, wiring as per approved wiring diagram on 19" Relay rack/Composite/Q-Series Relay Rack with subsequent alteration. This includes supply of 3/4 X 9" anchor nuts & bolts, washer, D-bracket & 60mm insulator, supply & fixing of M.S. ladder as per requirement for rack to rack connection, on CTR and control panel, fixing of plug boards, relays, terminal blocks, terminals, filter units, tag blocks, fuses, bus bars, shelves, strips, 6mm Hylam sheet 43 of required length for writing terminal description etc., fixing and termination of cables on the relay racks with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour including painting and lettering. Wiring and testing of complete relay rack accommodating all relays as per wiring diagram. Cement, stone chips & sand as required for mounting to be provided by contractor. All materials such as eyelets, Hylam sheets, ferrules, trough etc., if required for modification of rack shall be supplied by the contractor and to be carried out at site with no extra cost to the Railway.
Supply of MS Cable termination Racks (CTR) as per Drawing No. SK/DRG/OL/SER/197 or latest and must be powder coated of stone grey colour. Inspection: Representative of Sr.DSTE/Adra.
"Transportation, grouting/erection, fixing and installation of Cable Termination rack (CTR), fixing of MS Wiring ladder from relay rack to CTR, and on to top of the CTR- including supply of 3/6mm Hylam sheet of required size for fixing terminal blocks & writing terminal description, termination of cables, bunching of cables by PVC tape and earthing of cable armours, painting, lettering as required. The contractor shall draft terminal analysis chart on the white bond paper of appropriate size & supply wiring materials like eyelets of sizes, trough, condensers and resistances 45 as per required capacity, HV protection cover with fixing top caps and danger symbol, soldering material of approved quality etc. shall be supplied by the contractor. Cement, stone chips and sand as required for mounting CTR, Sand for filling of cable pit and other required masonry work, Sundry materials such as MS plate/angles, MS wiring ladders as per approved Drawing, , Anchor bolt 5/8"" X 9"" with nut and washers -4 No., Nickel plated screws 2BA X1"" with nuts and washers for fixing Hylam sheet, numbers embossed ferrules 2.5 sq. mm, PVC bunching tapes and buttons, paint synthetic enamel of smoke grey colour for painting, MS clamps with bolts and nuts of sizes, D- bracket and 60mm insulator, for fixing cables, screws of sizes as required shall be supplied by the contractor. Cables should be routed properly through ladder." Square
Supply of Yellow Highlighter Reflective Tape of grade retro reflective tape conform to IS 14221 or latest, BIS marked, Grade 2, Pressure type bonding for (Grade 1) R1-P. Inspection: Representative of Sr.DSTE/Adra. Square
Supply of Red Highlighter Reflective Tape of grade retro reflective tape conform to IS 14221 or latest, BIS marked, Grade 2, Pressure type bonding for (Grade 1) R1-P. Inspection: Representative of Sr.DSTE/Adra. Square
Supply of Black Highlighter Reflective Tape of grade retro reflective tape conform to IS 14221 or latest, BIS marked, Grade 2, Pressure type bonding for (Grade 1) R1-P. Inspection: Representative of Sr.DSTE/Adra.
Supply of Fail safe Electronic flasher device operated over 24V DC as per Specification No. RDSO/SPN/173/2002 with Amd-2 or latest. Inspection: RDSO.
Supply of '120 Second Fail Safe Electronic Time Delay Q series Relay, plug in type, 50 working over 24V DC, complete with plug board, retaining clip and connectors conforming to Specification No. IRS:S-61/2000 Amd.3 or latest. The interlocking code for this unit shall be "AFGKY". Inspection: RDSO.
Supply of metallic Colour Light Signal, Multi Unit type Two Aspect complete but 51 without lamp holder, lenses & transformers as per IRS:S-26/64 or latest and RDSO Drawing No. SA23003 A/M (Adv.) or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post. Inspection: Representative of Sr.DSTE/Adra.
Transportation and installation of 2-Aspect Signal Post for MACLS as per drawing no. Con/SK/T/12 or SEM- Drawing No. 19-D3 or RDSO/M-00011RU dated 12.01.18 or latest complete with signal units, base, ladder and other fittings, excavation of earth pit, casting concrete foundation, 52 erection of posts, thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary earth screen protection arrangement as required including termination of cables, painting and lettering as required. Foundation nuts & bolts of appropriate size as per above drawings or latest as per RDSO Drawing No. SA-116 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8. or latest to be supplied.
Supply of 140 mm diameter Cast Iron (Grade-20) Signal base as per Drawing No. S- 2011/M and as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of 5.5 meter Tubular (Seamless) Post for Colour Light Signal Specification No. IRS:S-6/81 or latest to suit 140mmm dia. base. Inspection: Representative of Sr.DSTE/Adra.
Supply of 5.5 meter Ladder for Colour Light Signal as per RDSO Drawing No. SA- 23156 (Adv.) or latest and Stage with Ladder foundation as per Drawing No. S-2033/M (IRS) or latest & as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of metallic Offset bracket for Colour Light Main Signal Unit to fix on post of 140 mm outside diameter as per RDSO Drawing No. SA- 23080 (Adv.) Alt-1 or latest and Specification No. IRS-S-10/78 or latest. Inspection: Representative of Sr.DSTE/Adra.
Transportation, Installation, Wiring, Testing & Commissioning of LED Signals Lamps 57 for Main signals Lighting Unit (i.e. Red/Yellow/Green) as per instruction of railway Engineer at the site. Note: LED particulars such as aspect, make, type, Sr. No. etc. to be recorded in proper in proper register.
Supply of Signal Number plate pressure sensitive Retro reflective type high intensity 58 grade white with imprinted 'Alphanumeric' in Black & White of size as per SEM Drg.19-D10 (Sheet 6 to 7) or latest with film thickness 0.3 mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg. No. 19-D10(Sheet 9-10) or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Arrow Marker Retro reflective type high intensity grade white with 59 imprinted Arrow Marker in white on red background of size as per SEM Drg.19-D10 (Sheet 8) or latest with film thickness 0.3mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg. No. 19-D10 (Sheet 9-10) or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Signal Marker Retro reflective type high intensity grade white/yellow with 60 imprinted 'A'/'G'/'C'/'AG/'IB'/'P' in black of size as per SEM Drg.19- D10(Sheet 1 to 5) or latest with film thickness 0.3mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg. No. 19-D10(Sheet 9-10) or latest. Inspection: Representative of Sr.DSTE/Adra.
Fixing of 'P'/'G'/'C'/'A'/'AG'/'IB'/Marker/Arrow marker/ Signal Number plates with complete fittings as per site requirement.
"Supply of PVC Insulated Single core Multistrand, unsheathed with plain 62 annealed/tinned copper conductor 16/0.2 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. Inspection: Representative of Sr.DSTE/Adra.
"Supply of PVC Insulated single core cable multistrand, unsheathed with plain 63 annealed/tinned copper conductor 3/0.75 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. Inspection: Representative of Sr.DSTE/Adra."
Supply of PVC insulated Single core Multi-strands Copper conductor of size 1 x 6 Sq.mm as per IS:694/2010 or latest conforming to Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Inspection: Representative of Sr.DSTE/Adra.
Supply of PVC Insulated Multicore copper conductor Indoor Cable of size 40 Core x 1.0mm diameter as per Specification No. IRS:S-76/89 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of 25 mm 6 Way PBT Terminal block as per Specification No. IRS:S-75/2006 Rev. 2.0 or latest as per IRS Drg. No. SA-23756 Alt-3 or its latest amendments. Inspection: RDSO.
Supply of PBT fuse base block as per Specification No. IRS:S-75/2006 Rev. 2.0 or latest as per IRS drawing No. . SA: 23748 with alt 4 or its latest amendments. Inspection: RDSO.
"Supply of Non-Deteriorating type low voltage electric fuse for Railway signalling, fuse with cylindrical cap without indication, cylindrical fuse as per Specification No. IRS:S-78/2006 or latest. ND Fuse Cylindrical Type 4/6 Amp. Inspection: RDSO.
Supply of Negative Bus Bar of size 20 mm X 5 mm made of copper bar with brass screw & washer minimum length of one piece is to be 0.3 m. The bar and screw should be nickel plated. Inspection: Representative of Sr.DSTE/Adra.
Supply of Pipe lock with key ring size inside dia. 40.5mm, outside dia. 60mm. Thickness 20mm, lock length 65mm. Inspection: Representative of Sr.DSTE/Adra.
Supply of Desk type Electronic Magneto Telephone (DTMF) as per Specification No. IRS: TC/79/2000 with amd 4.0 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of 12 mm thick Hylam Sheet of size 4 foot x 4 foot as per specification Nos. IS 2036 of 1995 or latest. Note:- In case the requirements are different from the above, proportionate payment will be done. Inspection: Representative of Sr.DSTE/Adra.
Design of circuits and plans to suit layout as per Signalling Interlocking Plan of IBS/ABS/LC GATE. This will include supply of Control cum Indication panel diagram, wiring diagrams 73 (Indoor and outdoor), Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement Axle counter wiring diagram and all other relevant drawings. Submission of Two sets of prints with all correction for Railway's approval. Approved copy (06 Sets) of all drawings in plastic folders along with the original tracings in spiral bound with editable AutoCAD file latest version.
Supply of Electrically operated lifting barrier (ELB) 24V/110V DC with hand generator having boom length of 9.76 meter/32 feet confirming to IS:277 or latest with Base metal as IS: 513 74 grade CR3 or latest. The boom shall be painted alternately with 300 mm bands of black and yellow colour and additionally provided with luminous stripes (reflective tape) as per RDSO Drg. No. RDSO/S 11600 or latest, complete set as per Specification No. RDSO/SPN/ 208/2012 Ver. 2 Amd.1.0 or latest. List of spares & tool kit items mentioned in Para 10 of RDSO Specification shall also be supplied. Inspection: RDSO.
"Transportation, installation, testing and commissioning of Electric lifting barrier (ELB) which includes excavation of pit, casting of foundations, fixing of pedestals, Boom rest etc., 75 installation and wiring of control panel, booms for level crossing gate complete in all respect including provision of boom locking arrangements with fixing of boom light box, stop board boom rest and equipment of operation of gate from control panel, painting, lettering with following accessories:- (i) 2 (two) nos. lifting barriers with all accessories. (ii)1 (one) Control panel (iii) Positive boom locking arrangements for above. (iv) Emergency crank handle attachment (v) Timer unit to adjust the time for operating the barrier (vi) Fixing of Hooters/Flashers on either side of gate barrier.
Supply of 'A/B' type foundation as per RDSO Drg. No. IRS-3529/M Alt-1 or latest and Specification No. IRS-S- 10/78 Rev 8 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Sliding Boom Gate as per drawing no. E. Rly Signal workshop/HWHs Drg No. SW/SA/29/768 or latest. This includes supply of 8 Nos. Key lock 'E' type with key as per Specification 77 No. IRS:S-30/64 or latest conforming to Drg No. 3376/M with latest amendment. Ward number to be decided by Railway Engineer & to be fixed on MS plate as mentioned in the drawing and it includes supply of all the nut and bolt with washer, Anchor Bolt and Pad lock 6 (Six) lever (make - Godrej or better) with three keys etc, to make the system complete functional. Inspection: Representative of Sr.DSTE/Adra.
Transportation, installation, testing and commissioning of Emergency Sliding Boom at 78 LC gates which includes casting of total 10 nos. concrete foundation including surrounding earthwork, fixing of lock post, clamps, welding of channel, cutting of rail post if required as per site condition. Note: All materials to be supplied by the contractor except Sliding Boom gates & key lock 'E' type.
Cement Concrete of proportion 1:2:4 (Cement: Sand: Stone chips of 20mm nominal 79 size) for miscellaneous works. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor.
"Supply of 25 watt horn, dual tone warning bell hooter for L.C gate and working on 110 VAC/24V DC. The contractor should get confirmation from Railway before placing an indent to manufacturer/supplier. Inspection: Representative of Sr.DSTE/Adra.
Supply of Master Telephone Unit with voice logging facility for LC Gate Telephone System as per Specification No. RDSO /SPN/TC/51/2011 Rev 1.0 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Slave Telephones unit for LC Gate Telephone System as per Specification No. RDSO /SPN/TC/51/2011 Rev 1.0 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Power Supply System having both 12V & 24 V DC Output including battery 83 charger with minimum 7AH, 24V DC MF Battery. 12V DC supply shall be connected to the Station Telephone Unit & 24V DC shall be fed to Line Circuit for LC gate telephone system as per Specification No. RDSO/SPN/TC-51/2011, Rev 1.0 or latest. Inspection: Representative of Sr.DSTE/Adra.
Dismantling of existing interlocked LC gate and other associated S&T gears. All the released material will be transported to the concerned SSE/Store or KGP workshop as instructed by site engineer.
"Supply, transportation, installation and painting of SLB/BSLB/Legend/Stop Board etc. 85 as per SEM Drawing No. 19-D4 or latest. This includes i) Excavation of earth pit of depth 900 mm, width 600 mm, ii) casting in the ratio of cement concrete mixture shall be 1:3:6, iii) foundation, (iv) Erection etc. Note: The sighting board supplied by the contractor to be as per SEM Drawing No. 12- D1 or specified by Railway. Inspection: Representative of Sr.DSTE/Adra."
"Transportation, installation and painting of SLB/BSLB/Legend Board/Stop board etc. 86 as per SEM Drawing No. 19-D4. This includes i) Excavation of pit of depth 900 mm, width 600 mm, ii) excavation& shifting of old boards to new position. Note: The contractor shall supply all the materials required for the work except Boards which are to be supplied by the railway and lighting arrangement to the SLB/BSLB."
Supply of Thermo-shrink jointing (TSF) kits for jointing underground Quad cable of size 0.9mm/1.4mm diameter conductor for straight/condenser/Y- (Derivation)/Loading Coil/Transformer Joints as per Specification No. IRS-TC-77/2012 Rev.3 with Amd. 3.0 or latest. Inspection: RDSO.
Execution of Derivation/Transformer joint on Quad cable/ jelly filled Telecom cable using Thermo- shrink/Universal jointing kit (RTSF). This includes excavation of cable joint pit of size 88 min 1.5 m X 1.5 m X 1.2 m for jointing of cables, back filling and ramming after jointing. After jointing, the cable through test such as insulation test, continuity test etc to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing the contractor has to redo the joint free of cost. Note: In case jointing is required to be done in the Location boxes, then 80% payment will be released.
Supply of VF Transformer (1120:470/1120:1120/470:470/ 470:600/1200:600 Ohm) as per Specification No. IRS-TC-76/2021 Ver 1.0 or latest (Cylindrical type) or IRS/TC/22/ 2021 Ver 1.1 or latest (Rectangular type). Inspection: Representative of Sr.DSTE/Adra.
Supply, transportation, fixing, wiring, termination of cable, erection of rail post of size minimum 2.8 meter including foundation of post in cement concrete (1:2:4) as per the direction of the section engineer in charge, testing and commissioning of Emergency socket box of cast iron make as per Drawing No.SE/T/50/76 or latest (6 pin Emergency Plug and Socket as per TC-42/20 90 Version- 1.1 or latest and other accessories). This includes transportation of rail posts, provided by the Railway, from any place/Station to work site; fixing of GI pipe and emergency socket box, GI pipe (make: TATA/Jindal or better) minimum 40 mm diameter, minimum 1.8 meter long as per IS 1239 grade medium, cast iron emergency socket with complete fittings. Supply of materials required for masonry work, U-bolt for fixing emergency socket etc., cutting of Rails and welding or suitable clamp of GI pipe on the rail post will be done by the contractor. Inspection: Representative of Sr.DSTE/Adra.
Preparation of Gate Working Rules (GWR) in English on the basis of station working 91 rule diagram and gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railways for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive.
Preparation of Gate working rules (GWR) in Hindi/Regional Language of that LC Gate 92 on the basis of gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railways for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive.
Supply of 1 copy of GWR in English finally approved by railways along with spiral binding. This has to be done after CRS sanction has been obtained. Inspection: Representative of Sr.DSTE/Adra.
Supply of 1 copy of GWR in Hindi/Regional Language that LC gate finally approved by railways along with spiral binding. This has to be done after CRS sanction has been obtained . Inspection: Representative of Sr.DSTE/Adra.
Supply of 25mm (1 inch) (PVC casing capping in rectangular shape with separate Casing & Capping, double lock, heavy duty & ISI mark with IS:14927 or latest with minimum 1 mm thickness. Inspection: Representative of Sr.DSTE/Adra.
Transportation and fixing of PVC Conduit pipe/channel/casing caping on wall or structure with drawls of Telecom/Power/Data cable with proper finishing. This includes supply of fixing materials including flexible pipe/bend etc. as required during course of execution.
Supply of 2 conductor Knife disconnect terminal block, screwless type i.e. Wago 97 confirming to Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Connection method: Spring- cage connection, Cross section: 0.2 mm² - 2.5 mm², Nominal current: 16 A, Nominal voltage: 400 V, Color: as per instruction of site engineer. Flammability rating according to UL 94-V0. Inspection: Representative of Sr.DSTE/Adra.
Supply of Steel Rail Carrier (Din Rail slotted) Size: 35mmx7.5mm as per Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Endplate/End stop suitable for disconnect terminal as per RDSO/SPN/189/2004 or latest. Inspection: Representative of Sr.DSTE/Adra.
Supply of Wago Marker (1-100) for wago terminal. Inspection: Representative of Sr.DSTE/Adra.
"Supply & laying of 300 mm X 300 mm pre-cast/cast in -situ RCC cable ducts 101 including top cover as per RDSO drawing No. SDO/S&T/RCC DUCT/1018/1 & 2, dated 29.5.23 or latest. Note- The rate is inclusive of all type of transportation including labour till it is placed into trenches. The laying of cables shall be paid separately fulfilling the laying procedure as per above drawings. Inspection: Representative of Sr.DSTE/Adra."
"Supply, Installation, Testing & Commissioning of Networkable Single loop addressable Fire alarm Control panel expandable upto 2 loops & interface with GSM/LTE module working as per RDSO/SPN/217/2021 ver-3 or latest. The control panel shall be networkable to Zonal /Divisional Headquarters preferably over TCP lP/OFC media converter and shall have clock synchronization facility. This schedule includes supply of TCP IP converter/Networking card/OFC media converter. The control panel shall have provision of Graphical software to enable remote monitoring of entire fire detection and alarm system of a station from Head Quarters. The control panel shall be designed to work on power supply of 110V/230V AC as well as on DC battery backup of adequate capacity to work upto 24 hrs. Backup. The Power supplies like batteries and chargers 102 shall be supplied by the contractor. The Control Panel shall have means for the user to visualize and interact with the complete Automatic Fire Detection and Alarm System layout through a user- friendly software executable on a standard Windows based Personal Computer. It shall be possible to download data and extend alarms from Control Panel through suitable ports like RS485/RS232/USB/TCP/IP into a PC/Laptop available with SSE at the installation and remote location (Divisional Control room) operating on Windows platform. The software for downloading and analysing fault data shall be provided & shall be compatible with the latest windows operating system. Detection, actuation, and control system shall have provision for automatic as well as manual operation. The control panel should have provision to connect a GSM/LTE module duly providing compatible SIM with SMS facility on minimum of 5 numbers (users). Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. Inspection: RDSO.
"Supply, installation testing & commissioning of Heat and smoke multi sensor with inbuilt fault isolator (open/short circuit in loop) as per specification No. RDSO/SPN/217/2021 ver-3 or latest and required to be provided at suitable locations inside the diesel generator room, battery 103 room, ASM room, power equipment room, non air conditioned RR, CCTV control & equipment rooms, way side OFC room and other S&T service rooms as directed by the Railway site Engineer. The location of fixing is to be meticulously decided so that full advantage of the system is achieved. Inspection: RDSO. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest.
"Supply, installation, testing & communication of Linear Heat Sensing (LHS)/Linear 104 Heat Detection (LHD) Interface module with all accessories for integration with main line fire alarm control panel as per RDSO specification No. RDSO/SPN/217/2021 ver-3 or latest. It should be UL/FM/Vds/LPCB approved/listed. Inspection: RDSO. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest."
"Supply, Installation Testing and commissioning of Analogue type Linear Heat Sensing cable/Linear Heat Detector hollow metallic pneumatic tube type with required module to be 105 integrated on main Fire Alarm Panel as per specification No. RDSO/SPN/217/2021 ver-3 or latest. It shall be laid in all cables tray located in power equipment room, relay room & telecom room and should be UL/FM/Vds/LPCB approved/listed. Inspection: RDSO. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest."
"Supply of Power supply System 24 V/2 Amp or other rating as per OEM with built in Charger with battery backup as per specification No. RDSO/SPN/217/2021 ver-3 or latest. Inspection: RDSO. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest."
"Supply, Installation, Testing & Commissioning of UL/LPCB/Vdc listed/approved Pipe 107 made of CPVC with suitable diameter & pipe accessories (couplings, unions, elbows, tees, end caps, capillary tubes, sampling ports, mounting brackets etc.) as per requirement for the Aspiration detection shall comply to RDSO/SPN/217/2021 ver-3 or latest. Inspection: RDSO. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest."
Supply of CO2 Fire extinguisher 4.5 kg capacity confirming to IS 15683: 2018 or latest with ISI mark provided with all fittings and accessories. Inspection: Representative of Sr.DSTE/Adra.
"Supply of Fuse Auto Change Over System (FACS) type-I/II along with audio visual indication as per RDSO spec. No. RDSO/SPN/209/2012 Ver.2.0 or latest. It shall work on 24V DC/60V DC/110V AC as specified by the purchasers. The system shall be capable of monitoring fuses with 109 system voltage of fuse circuit as 12V, 24V, 60V or 110V DC/AC Type-I: One module of Fuse Alarm System Should be able to cater for monitoring of 32 nos. of ""G"" type fuses from 0.6 Amp. to 4 Amp. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Or Type-II: One module of Fuse Alarm System Should be able to cater for monitoring of 24 nos. of ""G"" type fuses from 4 Amp. to 10 Amp. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. Inspection: RDSO
Installation, testing & commissioning of Fuse Auto Change Over System type-I / II along with audio visual indication as per RDSO spec. No. RDSO/SPN/209/2012 Ver.1.0 or latest.
"Supply of Fuse terminal block with LED indication up to 2.5 sq. mm screw type one in one out suitable for 400mA/630mA/1 A/1.6A/2A/4A/6.3A/8A10A or as decided by Engineer in charge as per RDSO SPN/189/2004 or latest. Inspection: Representative of Sr.DSTE/Adra."
Supply of portable battery-operated Surge Protective Device (SPD) life tester, designed for onsite testing of surge protection devices. It allows checking and indicating the health 112 status of GDT/MOV based SPD of voltage range 1mA to 20000V & leakage current upto 1000 micro ampere (Accuracy +-5%). it is having LCD 20 X 4 Character to display the various readings. It shall indicate the status of SPD by measuring its electrical parameters (varistor voltage, leakage current & Spark over Voltage). Make JMV/DHEN/CITEL or similar . Inspection: Representative of Sr.DSTE/Adra.
Supply and Installation of class A type Lightening Protection System as per following specification are as under, (i) Lightening arrester technology: Advance Early Steamer Emission. Material: High current discharge stainless steel. International standards: NFC 17- 102 or latest., (ii) 113 Mast material: minimum 2 meter FRP pipe and minimum 3 meter high-grade aluminium/steel. Dimension: 50mm., (iii) Down conduct cable: 50 Sq. mm PVC insulated copper cable having 75m length, (iv) Lightning strike counter: 6 digits counter, Current sensitivity: 1KA to 200 KA, 8/20 & 10/350 micro/Sec. induction Shunt: 0.5 micro. (v) Two (02) No. of maintenance Free Earth with all required accessories as per Specification No. RDSO/SPN/197/ 2016 Ver 1.0 or latest such as copper cables, strips etc. Inspection: Representative of Sr.DSTE/Adra.
Supply of Steel Table with sunmica Top with storage on both sides Unitised table. Model: T-9. Make: Godrej or better. Inspection: Representative of Sr.DSTE/Adra.
"Supply of multipurpose Computer chair. Model: CH-7B. Make: Godrej or better. Inspection: Representative of Sr.DSTE/Adra."
Supply of Storwel plain 4 shelf almirah of size 1980 mm X 915 mm X 485 mm). Make: Godrej or better. Inspection: Representative of Sr.DSTE/Adra. Above/
C-Integrated Power Supply System 3947984.00 Below/P
Supply & transportation of SMPS based Integrated Power Supply System (Mini IPS for LC gate) as per Specification Nos. RDSO/SPN/165/2023 Ver. 4.0, Amdt.1 or latest and conforming to 1 SE Railway Drawing Nos.SK/DRG/OL/SER/237 dated 16.09.2011 along with 2V/120 AH Low maintenance Lead Acid (LMLA) Battery Bank with complete accessories required for installation of IPS Cables: i) Between IPS System to ASM Panel-12 Core x 1.5 sq. mm = 35 mtrs, ii) System to Battery Bank-10 sq. mm =25 mtrs. Tools & Spare: It is to be supplied as per Annexure I & IV of RDSO specification. Inspection: RDSO.
"Transportation, grouting and laddering of Integrated Power Supply (IPS) System including laying & termination of power & signalling cables through ladder on Hylam sheet, fixed on MS angle, by contractor on wall in panel/IPS room of adequate size, painting & lettering. Note: Transportation of batteries, electrolyte, bolts & nuts, screws, trough etc. and other sundry materials required for the above work shall be supplied by the contractor as required. The IPS to be commissioned by the OEM."
Installation, Testing and Commissioning of SMPS based Integrated Power Supply System as per Specification Nos. RDSO/SPN/165/2023 Ver. 4.0, Amdt.1 or latest and conforming to SE Railway Drawing Nos.SK/DRG/OL/SER/237, dated 16.09.2011.
Item Breakup - B-SOR
Kilometre Total 1452163.40
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TAN3006Ver3_1dated30_06_2025_2.pdf
ATTACHMENT
IRGCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
JPOFinalason19FEB2024.pdf
ATTACHMENT
IRGCCApril2022AdvanceCorrectionSlipNo11_compressed.pdf
ATTACHMENT
IRGCCApril2022ACS_725NOV2024.pdf
ATTACHMENT
IRGCCApril2022ACS_114JUL2022.pdf
ATTACHMENT
IRGCCApril2022ACS_213DEC2022.pdf
ATTACHMENT
IRGCCApril2022ACS_8-20DEC24.pdf
ATTACHMENT
IRGCCApril2022ACS_9-9JAN25.pdf
ATTACHMENT
IRGCCApril2022ACS_326APR2023.pdf
ATTACHMENT
IRGCCApril2022ACS_10-4MAR25.pdf
ATTACHMENT
IRGCCApril2022ACS_407AUG23.pdf
ATTACHMENT
IRGCCApril2022ACS_520OCT2023.pdf
ATTACHMENT
IRGCCApril2022ACS_621DEC2023.pdf
ATTACHMENT
TenderDocument4INTERLOCKING.pdf
ATTACHMENT
IPSSPEC.pdf
ATTACHMENT
Download all tender documents and submit your bid