Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-Finance | ₹3.0 Cr | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹3.3 Cr+₹25.8 L (8.59%)Rejected-Finance | ₹3.3 Cr+₹25.8 L (8.59%) | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹3.3 Cr+₹32.5 L (10.8%)Rejected-Finance | ₹3.3 Cr+₹32.5 L (10.8%) | L3 | Rejected-Finance 3rd Lowest |
| 4 | Not Admitted-Fee/PreQual/Technical PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | - | - | Not Admitted-Fee/PreQual/Technical Others-Minimum Prequalification experience not submitted as per NIT and Bidding capacity is also less than ECPT |
Tender Value
₹3.5 Cr
EMD Value
₹6.9 L
Closing Date
12 Jul 2024, 3:00 pmClosed
Executive Engineer(Civil) IIT Hyd
Construction and Maintenance Division IIT Hyderabad
Constn of 193 NOs shaded 4wheeler parking 10 Ns 2wheeler shaded parking with the RCC for the ongong Precast FH and SH towers at IIT Hyderabad SH A and C 112 No four wheeler and 10 NO two wheeler parkings for ST1A ST2A ST2B ic electrical works
2024_IITH_814040_1
IITH/CMD/CIV/2024-25/NIT-13
Open Tender
Civil Works - Buildings
Item Rate
180 days
IIT Hyderabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6.9 L
6 Sept 2024
28 Jun 2024
15 Jul 2024
28 Jun 2024
12 Jul 2024
29 Jun 2024
Amount
Sub Head1: Civil Works
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
All Kinds of Soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns, etc.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Lintels, beams, plinth beams, girders, resumes and cantilevers.
Suspended floors, roofs, landings, balconies and access platform
Edges of slabs and breaks in floors and walls
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
All works upto plinth level
Concrete of M30 grade with minimum cement content of 350 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
All works above plinth level upto floor V level
Concrete of M30 grade with minimum cement content of 350 kg /cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
Thermo-Mechanically Treated bars of grade Fe 500D or more.
Providing and laying solid concrete blocks masonry with block of M10 grade cement concrete of required thickness as per drawing in superstructure above plinth level up to V level with RCC band and mullion as per structural detail in cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction of Engineer.
12mm cement plaster of mix
1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:4 (1 cement: 4 fine sand)
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite stone slab colour black, Cherry/Ruby red
Area of slab upto 0.50 sqm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Full Body Industrial Parking Tiles of minimum 20mm thk as per direcrtion of Engineer In Charge
Supply and fixing traffic corner guards to the coloumns of size 1000 mm height as per approved design and model and as per the direction of Engineer In Charge
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. or As per the direction of Engineer of In Charge.
For horizontal surface one coat @1.10 kg per sqm.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler
Sub Head2: Electrical Works
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm +1X 1.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)
6 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without
4 way (4 +12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
For 6 way, Double door SPN MCBDB
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Supplying and laying 25 mm X 5 mm G.l strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
upto 35 sqmm (clamped with 1 mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 25 sq. mm (28mm)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
150 mm dia
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of XLPE Insulated PVC Sheathed, FRLS, Copper Conductor Armoured power cable of 1.1 KV grade conforming to IS : 7098 (Pt-1) 1988 amended upto date and as per specifications. All cables shall be tagged.
4Core X 6 Sq.mm copper cable
Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of XLPE Insulated PVC Sheathed, FRLS, Aluminium Conductor Armoured power cable of 1.1 KV grade conforming to IS : 7098 (Pt-1) 1988 amended upto date and as per specifications. All cables shall be tagged.
3.5C x 50 Sq.mm
Supply, Installation, Testing and Commissioning of 1X18W round Surface mounted LED Light full glow Downlighter along with electronic driver with complete accessories, etc., as required. (Make : Philips, Model No. : CW 929003094301)
Supplying and fixing of 40 Amps, 415 volts, “C” curve TPN MCB in the existing DB, on surface or in recess with complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of Indoor type Lighting panel along with Digital Timer arrangement with Automation system associated with suitable wiring as follows:
A) Incomer Feeder : 1) 63A TP, 25KA, MCCB with TM O/C, S/C (Make : L&T, Model No. : CM91612OOHOOG) - 01 No. 2) Extended Rotary Handle (Make : L&T, Model No : CM97896OOOO) - 01 No. 3) Auxilary + Alaram Contact Block (Make : L&T, Model No : CM97890OOOO) - 01 No. 4) RYB Phase Indication Lamps (Make : L&T (Esbee) - 01 No. 5) ON, OFF, Trip, Indication Lamps (Make : L&T (Esbee) - 01 No. 6) 6A SP, 10KA, MCB, C Curve (Make : L&T, Model No. : BB10060C)- 04 Nos 7) Neutral Link (Make : Reputed) - 02 No's
C) Outgoing Feeders 1) 16A TP, 10KA, MCB, C Curve (Make : L&T, Model No. : BB30320C) - 03 No's
Effects Engineers and Contractors
UPENDAR REDDY KATKURI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .