Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC LOA |
| 2 | L2₹1.3 Cr+₹8.4 L (6.73%)Rejected-Finance HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | PANCHKULA | HARYANA | 134118 | ₹1.3 Cr+₹8.4 L (6.73%) | L2 | Rejected-Finance Highest |
| 3 | L3₹1.4 Cr+₹11.6 L (9.23%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹1.4 Cr+₹11.6 L (9.23%) | L3 | Rejected-Finance Highest |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
22 Nov 2023, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Construction of MCH Block and Service Block in the campus of Civil Hospital, Sec.-6, Panchkula. (Pdg. Addl. Internal E.I Work)
2023_HRY_325289_1
2023B7482AAB CBD4 4932 96D0 E347CD62005E663BAR
Open Tender
Civil Works
Works
110 days
Ambala Cantt
Construction of MCH Block and Service Block in the campus of Civil Hospital, Sec.-6, Panchkula. (Pdg. Addl. Internal E.I Work)
2 documents required · 2 mandatory
₹15,000
₹2.3 L
Yes
18 Jul 2024
31 Oct 2023
23 Nov 2023
2 Nov 2023
22 Nov 2023
2 Nov 2023
Amount
[23.10]Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work.
[23.11]Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
[23.13]Supply, erection and fixing of 12 mm thick ply wood board having a circular /rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.
[23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required
[23.21]Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm
[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm
[23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre
[23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mm
[23.24.3.10]MS STAND, BUS BAR CHAMBER AND PANELS 3.10. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 400 amp 4 bars of 55 cm each (cross section 63 mm x 6 mm) chamber over all size 60 cm x 55 cm x 23 cm
[23.24.3.5]MS STAND, BUS BAR CHAMBER AND PANELS 3.5. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 200 amp 4 bars of 55 cm each (cross section 38 mm x 6 mm) chamber over all size 60 cm x 45 cm x 18cm
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame.
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data
[23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules
[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch
[23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch
[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket
[23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket
[23.9]Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level.
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm
[24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia
Erection of Ceiling Fan with all labour and petty material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Erection of LED Bulk Head fitting with all labour and petty material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supply and erection of lighting arrestor model ISI Marked suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resistor element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work.
Supply and Erection of Copper Strip 40mm x 5mm including all labour and petty material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supply and Erection of UPVC trunking 100mm x 50mm to complete the job in all respect upto the entire satisfaction Engineer-in-charge of work. Make-MK, Model -NCT1050D1WHI
Supply and Erection of fabricated shed with MS pipe, MS Pillar, MS Sheet and MS Mesh with all labour and petty material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the work.
Supply and Erection of PVC insulated aluminium armoured cable 50 Sqmm x 3.5 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 120 Sqmm x 3.5 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 185 Sqmm x 3.5 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 300 Sqmm x 3.5 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 400 Sqmm x 3.5 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 16 Sqmm x 4 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 25 Sqmm x 4 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated aluminium armoured cable 35 Sqmm x 4 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Supply and Erection of PVC insulated Copper armoured cable 16 Sqmm x 4 Core 1100 Volts grade including all labour and petty material required to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make-Havell`s / R.R Kabel / Polycab
Distribution Load Panel-Power Supply, Installation, Testing and Commissioning of Wall/free-standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of No.t less than 3 mm thickness a separate detachable gland plate MS base channel hinged door with interlocking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separate cable alley to BBC from the switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structures. The panel will be complete with control wiring (copper) and fuse protection with all labour and petty material required to complete the job in all respect upto the entire satisfaction of engineer in charge of work. The following specification is as under:- Incoming feeder :- 01 Nos. -800A 4P MDO ACB 50KA With Microprocessor Based Release For {O/C, S/C} Protection, 4NO plus 4NC Aux. -Digital VAF Meter Class-1.0, 96X96 Sqmm -CTs 800/5A, Class-1, {CMCT} For Metering -ON/OFF Indicating Lamps (LED TYPE) -R/Y/B Phase Indicating Lamps (LED TYPE) -6A, SP, MCB, 10KA For Control Ckt. -6A Neutral Link Dropout Type, For Control Ckt. Outgoings feeder :- 06 Nos. -400A 4P MCCB 50KA With Thermal Magnetic Release For {O/C, S/C }Protection Spreader Terminal -Extended Rotary Handle -Space feeder :- 02 Nos. -BUSBAR - Main Bus Bar -TPN Copper busbar made from Electrical Grade -Copper flats (E-91-E) 800 AMP Duly supported on DMC insulators and covered with heat shrinkable sleeves. -Enclosure, Bus Bar and Wiring and Accessories -MS Cabinet with integrated Base Frame and Powder Coated Paint -Hardware and Accessories - Nuts, Bolts, Washers -Door Hinges and Locks, Neoprene Rubber Gaskets -Mounting Plates, MS Channels, Partitions, Lifting Hooks and Gland Plates -PVC Wires, Ferrules Thimbles and Other Wiring Accessories. -Consumables, Design and Development, Drawings -Manufacturing Cost i.e. Fabrication, Painting, Bus Bar, fitting, Handling and fitting of switchgears. Make as per Approved list
M/S GARG ELECTRICAL
M/s JSB Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .