Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69,683.96Admitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹89,492.05+₹19,808.09 (28.4%)Admitted-Fee/PreQual/Technical/Finance CA 325 SA767 PWD K EL 13 1 472 CASAMARINA COMPLEX TALAP KANNUR | KANNUR | KANNUR | KERALA | 670101 | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Sajju T L2 | Vinod Kumar M L1 |
|---|---|---|---|---|---|
| 1.00ELETRIFICATION | |||||
| 1.00 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | 15 | point | 1,082 ₹16,230 | 1,081 ₹16,215 Lowest |
| 1.00 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 2 | each | 500 ₹1,000 | 395.99 ₹791.98 Lowest |
| 1.00 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: | 2 | each | 2,804 ₹5,608 | 2,704.72 ₹5,409.44 Lowest |
| 1.00 | OD158578/2026-2027:Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required. | 3 | each | 462 ₹1,386 | 362.83 ₹1,088.49 Lowest |
| 1.00 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket
Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | 3 | each | 1,415 ₹4,245 | 1,314.7 ₹3,944.1 Lowest |
| 1.01 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 3 | each | 2,728 ₹8,184 | 117.99 ₹353.97 Lowest |
| 1.01 | OD158582/2026-2027:Supply,Conveyance, installation, testing and commissioning of wall light
fittings of all types directly on wall giving connections with required length
of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or
with the extended original wiring, making good the damages, colour washing etc as
required.(philips comet wall light model no. 6535/ equivalent) | 3 | each | 916 ₹2,748 | 816.71 ₹2,450.13 Lowest |
| 1.01 | OD57375/2026-2027:Supply and providing the following types and power rated lamps in the existing
fittings as required. B22 LED bulb 9W | 6 | each | 220 ₹1,320 | 120.25 ₹721.5 Lowest |
| 1.01 | OD57370/2026-2027:Supply ,Conveyance, installation, testing and commissioning of 12 W LED Bulkhead Light fittings Lumen output - 600, Housing - High pressure die cast aluminum directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.(LUKER STYX ECO BULKHEAD LIGHT 12W LBKOVSL12/equivalent) | 3 | each | 563 ₹1,689 Lowest | 563.3 ₹1,689.9 |
Tender Value
₹69,939
EMD Value
₹1,748
Closing Date
13 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
GENERAL-Rewiring of D36 NGO Quarters rewiring-General Electrical Work
2026_PWD_885954_1
PWD/BLDG/TR/4728/2026_6_1_1/1
Open Tender
Electrical Works
Item Rate
60 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹1,748
16 Nov 2026
5 Nov 2026
16 Nov 2026
5 Nov 2026
13 Nov 2026
5 Nov 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ELETRIFICATION | |||||
| 1.001 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | 15 | point | - | - |
| 1.002 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 2 | each | - | - |
| 1.003 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: | 2 | each | - | - |
| 1.004 | OD158578/2026-2027:Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required. | 3 | each | - | - |
| 1.005 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket
Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | 3 | each | - | - |
| 1.006 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 3 | each | - | - |
| 1.007 | OD158582/2026-2027:Supply,Conveyance, installation, testing and commissioning of wall light
fittings of all types directly on wall giving connections with required length
of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or
with the extended original wiring, making good the damages, colour washing etc as
required.(philips comet wall light model no. 6535/ equivalent) | 3 | each | - | - |
| 1.008 | OD57375/2026-2027:Supply and providing the following types and power rated lamps in the existing
fittings as required. B22 LED bulb 9W | 6 | each | - | - |
| 1.009 | OD57370/2026-2027:Supply ,Conveyance, installation, testing and commissioning of 12 W LED Bulkhead Light fittings Lumen output - 600, Housing - High pressure die cast aluminum directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.(LUKER STYX ECO BULKHEAD LIGHT 12W LBKOVSL12/equivalent) | 3 | each | - | - |
stage.html
html • 0.02 MB
finance_1510913.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1510913.xls
BOQ • 0.33 MB
MOM.pdf
Tender Documents • 0.21 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 2.36 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .