Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC 29 DR LALIT BANERJEE SARANI KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.3 L+₹1,518 (0.36%)Rejected-Finance 197 4 KANTADANGA ROAD FINGAPARA N24PGS PIN 743129 | FINGAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.5 L+₹19,402 (4.54%)Rejected-Finance 174 G 1 NETAJI COLONY BARANAGAR KOL 700090 | BARANAGAR | KOLKATA | WEST BENGAL | 700090 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹9,500
Closing Date
24 Feb 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, P.W.D, N 24 Prg El Divn.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
E.I work at Proposed 24 bedded hybrid CCU of Dr. J R Dhar S.D Hospital, North 24 Parganas.
2023_WBPWD_464718_1
WBPWD/EE/N24PRG/ELEC/NIT- 81 /22-23.
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Dr. J R Dhar SDH, Bongaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,500
6 Apr 2023
2 Feb 2023
27 Feb 2023
2 Feb 2023
24 Feb 2023
2 Feb 2023
Amount
Supplying and fixing 415V, 125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Havells/Siemens) For Ground Floor).
Supplying and fixing of 8-Way Vertical TPN MCB Distribution board for MCCB incomer with IP-43 metal double door protection on angle iron frame on wall & mending good the damages to original finish ,provided with insulated vertical phase bus-bars, neutral bar/s with shroud/s, earth bar/s, sticking saddles,colour coded interconnecting wire set, ckt identification lables, cement spill protector, etc. & provision for earthing attachment having 125 A 4 Pole MCCB as incomer and 2 nos 80 A TP MCB & 2 nos. 63A TP MCB, 2 nos 25A TP MCB as outgoing. (Make-Legrand /L&T/Siemens) (80A for TFA & Condenser unit, 63A for AC Outdoor unit, 25A for Exhaust Unit).
Cable end box (16SWG) for TPN vertical MCBDB 8-way.
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the sizes-200x150x100 mm, making arrangment of one no. four pole Isolator/MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting & connection. (2 nos. for TFA type Air Handling indoor unit, 2 nos. for Compressure unit and 4 nos. for 17 TR Air Conditioning outdoor unit).
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make- L&T/ Legrands/Havells). 6-32A SP
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make- L&T/Legrand/Schneider). 40A FP
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Legrand/Crabtree/Schneider) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 4 nos. 20A plug socket with separate 4 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Legrand/Crabtree/Schneider) on sheet metal switch board embedded in wall incl. S & F 300x200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (For Lab).
Supply delivery of XLPE insulated cables of following sizes (Make- Gloster /Havells /RR /KEI). a) 4 Core 70 Sqmm (Main Switch to Ground Floor VTPN incommer).
b)4 Core 35 Sqmm (VTPN to Timmer DB).
c)4 Core 25 Sqmm (Timmer DB to Loop Box).
Laying of cable following cables on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. a)4 Core 70 Sqmm.
b)4 Core 35 Sqmm.
c)4 Core 25 Sqmm.
S&F of compression type gland complete with brass gland, rubber rings for dust & moisture proof entry of PVC armoured cables as below as per G.S. a)4 Core 70 Sqmm.
b)4 Core 35 Sqmm.
c)4 Core 25 Sqmm.
Finishing the ends of following cables by crimping method including S/F dowells solderless sockets, tapes and jointing materials etc. as per G.S. a)4 Core 70 Sqmm.
b)4 Core 35 Sqmm.
c)4 Core 25 Sqmm.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required- 50mm dia
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand/Crabtree/Schneider), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc (For AC)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand/Crabtree/Schneider) & necy. Connections. (For AC)
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand/Crabtree/Schneider) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For AC)
S & F of LT single Phase time control box of 2+12 way SPNDB as enclosure having hinged door locking arrangement consisting of the following accessories with suitable size copper wire incl. finishing the ends by crimping method and painting with powder coated paint over one coat of RO primer i) 25Amps DP MCB (Legrand) 1 No. ii) 2 pole power contractor (L&T Make) - MNX -22 - 1 no. iii) Digital time switch (L & T Make) - 1 No. iv) toggle switch - 1 no. v) LED indicating Lamp - 1 No. vi) 2 way Terminal studbold 25A - 2 no.
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Polycab/Finolex/KEI/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish] (Avg. run-8mtr)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Polycab/Finolex/KEI/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For AC & Power Board)
4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC (For Exhaust )
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make-Finolex/Havells/Mescab/Policab) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC
4 x 84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC
4 x 80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sqmm
Supply & Drawing 4 x 35 Sqmm + 2 x 10 Sqmm single core PVC copper wire in 50 mm dia flexib;e pipe fixed on wall on GI saddle as per GS. (Make-Gloster /Havells /RR/KEI).
Socketing the ends of 35 sqmm copper wire by solderles copper socket as per GS.
Dismentling and Re-fixing of Industrial Plug with control Box from Panel Room to UPS Room as per direction of EIC.
Shifting and Installation of 30KVA Servo Controller system from Panel Room to UPS Room as per direction of EIC.
Fabrication & Delivery of Iron Angle Platform of size 4ft (L) x 3ft (W) x 1ft (H) suitable for 150Kg weight lifting as per direction of EIC
Supply only twin LED tube light fittings, (Make - Philips/Crompton/Wipro) Cat no- TMC 501P 2 X T-LED 22W P3242 with 2 no's LED tube lamp MAS LED tube 1200mm 18W865 T8 I -2100lm, PC body.
Supply only Single LED tube light fittings, (Make - Philips/Crompton/Wipro) Cat no- TMC 501P 1 X T-LED 22W P3241 with 1 no's LED tube lamp MAS LED tube 1200mm 18W865 T8 I -2100lm, PC body
Supply and delivery of 30W LED street light with following specification: Surge Protection (minimum) : 4KV IP Certified : 66 Housing - Pressure Die -cast Housing Efficiency - 110Lm/Watt(Minimum) Light Colour - Cool day light
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. (20 nos. for shifting purpose)
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Supply & Fixing of 3 way ceiling Rose.
S& F 12“ (300mm) sweep 1420 RPM 80Watt Metal Body AC Exhaust fan incl making hole on wall with nuts & bolts as required with louver shutter as per GS (EPC make/ Crompton).
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Exhaust fan (12")
S & F 240V, 54Watt, 1360RPM, AC 400mm Sweep sheet metal body with thermal over load protection for long lasting wall mounting type wall bracket fan on wall by suitable size steel fastnut and making connection as required. (make- Crompton,/ Orient).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe with excavation of soil.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages, No. 8 SWG
M/S R. K. ENTERPRISE
KANJILAL and SONS
technical_934025.pdf
PDF • 0.26 MB
techsummary_934025.pdf
PDF • 0.48 MB
finance_934025.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_934025.pdf
PDF • 0.18 MB
AOC81.pdf
PDF • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .