Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹41.4 LAccepted-AOC A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | 1 | Accepted-AOC accept | |
| 2 | 2₹50.9 L+₹9.5 L (22.9%)Rejected-AOC | 2 | Rejected-AOC reject | |
| 3 | L3₹50.9 L+₹9.5 L (22.9%)Rejected-AOC | L3 | Rejected-AOC reject | |
| 4 | Rejected-Technical 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | - | Rejected-Technical Not qualified |
Tender Value
₹49.8 L
EMD Value
₹49,750
Closing Date
6 Apr 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EWC
Opposite Circuit House, Katju Marg, Bareilly
Strengthening of 33 KV lines At Various places under EUDC Bareilly
2024_MVVNL_919959_1
91/EWC(B)/2023-24
Open Tender
Electrical Works
Item Rate
30 days
BAREILLY
AS PER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹3,540
SE EWC
₹49,750
24 Aug 2024
22 Mar 2024
6 Apr 2024
22 Mar 2024
6 Apr 2024
22 Mar 2024
Amount
Part- (A) WORK SPECIFICATION FOR FOR 3400 M. 33 KV CABLE LAYING FOR DAMAGE CABLE OF 33KV LINE QUILA NO. 5 AND NO.15 AT PLACE OVER BRIDGE, KAHKASHA COLONY, MATHURAPUR, RAILWAY CROSSING AND KHANNA FURNITURE
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
33 KV 3X300mm2 XLPE Cable
33 KV 3X300mm2 XLPE Cable jointing kit O/D
33 KV 3X300mm2 XLPE Cable jointing kit S/through
ST pole 11 Mtr. Long
33 KV pin insulator
33 KV pin with nut
M.S. Earthing rod
M.S angle 65x65x6mm, 2700mm
Top channel 125x65x6mm 3200mm
T- Off Channel 125x65x1300mm
ACSR Dog conductor
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
Double pole cable exposer of ST pole
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
Double pole cable exposer of ST pole
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
Cable laying by drill method single circuit in HDPE Pipe.
Cable laying by drill method single circuit.
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D or S/Th Cable Jointing Kit
Fixing of cable route marker.
Part- (B) WORK SPECIFICATION FOR RECONDUCTORING OF 08 KM OVERHEAD 33 KV MAHANAGAR LINE FROM 132 KV S/S BALIPUR
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
ST pole 11 Mtr. Long
ST pole 13 Mtr. Long
33 KV cross arm
33 KV pin insulator
33 KV pin with nut
M.S. Earthing rod
M.S. Angle 50x50x6mm
M.S. Angle 75x75x6mm
ACSR Dog conductor
11 KV disc insulator B&S type 70 KN
Disc fitting Dog/Racoon 70 KN
Complete Stay set complete
Gaurding angle 65x65x2950
G.I wire 8 Swg
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
Single support of ST Pole 11mtr long
Single support of ST Pole 13mtr long
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Supply of suspension type clamp for Dog conductor.
Laying and sagging of 3 phase ACSR Dog conductor from tower of 66KV of existing Mahanagar line at Green Park colony to 132 KV S/S Balipur substation including jumpering, hoisting, fixing of all type of insulators,armor rod, ferrule, binding, jointing and its clamping etc. in all respect.
Safe dismentling of old & rotten ACSR Raccon conductor of existing 33 KV Mahanagar Line on 66 KV tower without damage of any insulator, clamp etc.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Dismantaling of old damage x-arm (10No.) and insulators (20No.) and erection of new 33 KV X-arm (10 No.) and Pin insulators(20 No.) in place of damage X-arm and insulators.
Repairing of existing tower base of 33 KV line with welding of newly MS angle (provided by department)
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
Single Pole of S.T Pole .
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
Loading. unloading and safe carrige of old & rotten Raccon conductor (almost 18 km.) from site to Store center, Bareilly (Distance upto Approx 2 km).
Part- (C) WORK SPECIFICATION FOR RECONDUCTORING OF 1.1 KM OVERHEAD 33 KV PARSAKHERA LINE FROM 220 KV S/S C.B. GANJ
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
33 KV 3X300mm2 XLPE Cable
33 KV 3X300mm2 XLPE Cable jointing kit O/D
33 KV 3X300mm2 XLPE Cable jointing kit S/through
ST pole 11 Mtr. Long
ST pole 13 Mtr. Long
33 KV cross arm
33 KV pin insulator
33 KV pin with nut
M.S. Earthing rod
M.S angle 65x65x6mm, 2700mm
Top channel 125x65x6mm 3200mm
ACSR Dog conductor
11 KV disc insulator B&S type 70 KN
Disc fitting Dog/Racoon 70 KN
Complete Stay set complete
Gaurding angle 65x65x2950
G.I wire 8 Swg
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
Single support of ST Pole 11mtr long
Single support of ST Pole 13mtr long
Doudle pole structure on 11 Mtr. ST Pole.
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Laying and sagging of 3 phase ACSR Panther conductor from Double pole upto the gentry at 132KV substation / 33KV substation including jumpering, hoisting, fixing of all type of insulators,armor rod, ferrule, binding, jointing and its clamping etc. in all respect.
Safe dismentling of old & rotten ACSR Raccon conductor of existing 33 KV DD Puram Line without damage of any insulator, cross arm, clamp etc. of existing 33 KV line.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Dismantaling of old damage x-arm (5No.) and insulators (15No.) and erection of new 33 KV X-arm (5No.) and Pin insulators(15 No.) in place of damage X-arm and insulators.
Fabrication and fixing of guarding angle on Single/double poles, Stringing and sagging of three nos. Earth/GI wire with cardle guarding of above 33 KV line as per RESSPO Norms including provision of all necessary clamps and hooks. Shifting of existing line conductor of 11 KV/LT line to maintain proper clearance in between both lines (all required material will be provided by the contractor except guarding angle and earth/GI wire).
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
Single Pole of S.T Pole .
Double pole of ST Pole
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D or S/Th. Cable Jointing Kit
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of Incharge.
Loading. unloading and safe carrige of old & rotten Raccon conductor (almost 3.3 km.) from site to Store center, Bareilly (Distance upto Approx 2 km).
TYCOON ENGINEERS
M/S SUPER ENGINEERING TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .