Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | ₹44.9 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹48.7 L+₹3.7 L (8.33%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹48.7 L+₹3.7 L (8.33%) | L2 | Rejected-Finance HIGH BID VALUE |
| 3 | L3₹49.2 L+₹4.2 L (9.42%)Rejected-Finance RANGAPARA TOWN WARD NO 1 PS PO RANGAPARA DIST SONITPUR ASSAM | ₹49.2 L+₹4.2 L (9.42%) | L3 | Rejected-Finance HIGH BID VALUE |
| 4 | L4₹50.0 L+₹5.1 L (11.2%)Rejected-Finance 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | ₹50.0 L+₹5.1 L (11.2%) | L4 | Rejected-Finance HIGH BID VALUE |
| 5 | L5₹50.3 L+₹5.4 L (12.0%)Rejected-Finance | ₹50.3 L+₹5.4 L (12.0%) | L5 | Rejected-Finance HIGH BID VALUE |
| Sl No | Description | Qty | Unit | shree kamakhya traders L1 | RS COOLING APPLIANCES L4 | M/s JK Jangid and Company L2 | M/s Ravi Enterprise L5 | United Traders L3 | SNEH CORPORATION L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR complete all as specified and directed. | 8 | Each | 67,300 ₹5,38,400 | 69,000 ₹5,52,000 | 75,000 ₹6,00,000 | 86,000 ₹6,88,000 | 52,000 ₹4,16,000 Lowest | 72,500 ₹5,80,000 |
| 2.00 | Supply , install , testing and commissioning of window type air conditioner of capacity 1.5TR electric driven (single phase), cooling capacity 4500 K Cal per hour BEE 5 star rated complete with cordless remote control unit complete all as specified and directed . | 4 | Each | 49,300 ₹1,97,200 | 51,500 ₹2,06,000 | 50,000 ₹2,00,000 | 56,000 ₹2,24,000 | 39,000 ₹1,56,000 Lowest | 52,400 ₹2,09,600 |
| 3.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed. | 2 | Each | 51,300 ₹1,02,600 | 54,000 ₹1,08,000 | 55,000 ₹1,10,000 | 56,000 ₹1,12,000 | 49,000 ₹98,000 Lowest | 55,700 ₹1,11,400 |
| 4.00 | Supply and draw submain wiring with two single core 4 sq mm FR PVC insulated copper cable 1100 volts grade multi stranded, un sheathed conductor in PVC Casing Capping including 4 sq mm multi-strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. | 591 | RM | 280 ₹1,65,480 Lowest | 320 ₹1,89,120 | 480 ₹2,83,680 | 400 ₹2,36,400 | 420 ₹2,48,220 | 495 ₹2,92,545 |
| 5.00 | Supply and fix in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. | 45 | RM | 650 ₹29,250 Lowest | 798 ₹35,910 | 900 ₹40,500 | 856 ₹38,520 | 752 ₹33,840 | 935 ₹42,075 |
| 6.00 | Supply and fix in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed. | 45 | RM | 400 ₹18,000 Lowest | 498 ₹22,410 | 490 ₹22,050 | 569 ₹25,605 | 561 ₹25,245 | 490 ₹22,050 |
| 7.00 | S&F Nitrile Rubber insulation for copper tubing of size 5/8'' dia duly wrapped complete all as specifed and directed. | 45 | RM | 100 ₹4,500 Lowest | 118 ₹5,310 | 110 ₹4,950 | 136 ₹6,120 | 232 ₹10,440 | 125 ₹5,625 |
| 8.00 | S&F Nitrile Rubber insulation for copper tubing of size 3/8'' dia duly wrapped complete all as specifed and directed. | 45 | RM | 100 ₹4,500 Lowest | 165 ₹7,425 | 170 ₹7,650 | 196 ₹8,820 | 245 ₹11,025 | 165 ₹7,425 |
| 9.00 | S & F drain pipe 5/8" dia PVC jacketed heavy duty with fixing of clamp. | 142 | RM | 80 ₹11,360 Lowest | 134 ₹19,028 | 100 ₹14,200 | 165 ₹23,430 | 145 ₹20,590 | 135 ₹19,170 |
| 10.00 | Supply and fixing angle iron brackets made of steel including two coats of powder coated finish and foundation bolts and nuts firing complete and making good the disturbed surface. | 14 | Set of 2 | 895 ₹12,530 Lowest | 917 ₹12,838 | 900 ₹12,600 | 1,035 ₹14,490 | 1,210 ₹16,940 | 1,020 ₹14,280 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
4 Aug 2025, 6:00 pmClosed
SHRI SAURABH, IDSE
HQ CWE Tenga PIN-900194 c/o 99 APO
PROVN OF AC, COOL ROOM FOR STORAGE OF FROZEN MEAT, DEEP FREEZER, REFRIGERATOR FOR VARIOUS UNITS UNDER GE MISSAMARI
2025_MES_719005_1
8551/E8
Open Tender
Civil Works
Item Rate
180 days
GE Missamari
D c (i)
8 documents required · 8 mandatory
₹500
Yes
GE MISSAMARI
₹87,000
Yes
19 Sept 2025
7 Jul 2025
11 Aug 2025
7 Jul 2025
4 Aug 2025
21 Jul 2025
Amount
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR complete all as specified and directed.
Supply , install , testing and commissioning of window type air conditioner of capacity 1.5TR electric driven (single phase), cooling capacity 4500 K Cal per hour BEE 5 star rated complete with cordless remote control unit complete all as specified and directed .
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed.
Supply and draw submain wiring with two single core 4 sq mm FR PVC insulated copper cable 1100 volts grade multi stranded, un sheathed conductor in PVC Casing Capping including 4 sq mm multi-strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete.
Supply and fix in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F Nitrile Rubber insulation for copper tubing of size 5/8'' dia duly wrapped complete all as specifed and directed.
S&F Nitrile Rubber insulation for copper tubing of size 3/8'' dia duly wrapped complete all as specifed and directed.
S & F drain pipe 5/8" dia PVC jacketed heavy duty with fixing of clamp.
Supply and fixing angle iron brackets made of steel including two coats of powder coated finish and foundation bolts and nuts firing complete and making good the disturbed surface.
S & F AC Socket with motor starter MCB DP 25 Amps capacity AC 230 Volt with Plug Top with Indicator complete all as specified and directed.
Supply and fixing copper cable 4.0 sqmm 4 core duly connected and properly clamped from indoorunit to Outdoor unit complete all as specified and directed
Supply, installation, testing and commissioning of Cold Room for storage of 4 Ton Frozen Meat and and 3 Ton of Vegetables designed for temperature -18 to -20 deg celsius for Cold room and +2 to +4 for ante room at ambient temperature of 40 Degree Celsius and , 415 V, 50 HZ, modular pre-frabricated 125 mm thick PUF Panel on walls and ceilings and 100 mm thick PUF insulation on floors of density 40Kg/m³ with lamination thickness 0.4mm and finish with PPGI of Cold room of size 10X10X8 (in feet) including anti room of size 6 X 10 X 8(in feet) with 4 Nos of flush type doors with size of 34" x 78" with 125 mm thick PUF panels insulation of density 40Kg/m³ with lamination thickness 0.4mm and finish with PPGI with Reciprocating Hermetic compressor with refrigeration capacity of 5000BTU/Hr for plus and minus room and cooling capacity of 6000 BTU/Hr for plus and minus rooms refrigeration unit with under voltage / Over Voltage /Phase reverse protection relays , inbuilt MC Bin Machine in ODU and 2 Nos Evaporater Unit and 02 Nos Outdoor units complete all as specified and directed.
Supply and fix Deep Freezer electric driven (single phase), capacity Glass top , 405Litres , .BEE 5 star rated complete all as specified and directed
Supply, installation, testing and commissioning LT Pannel Board 415 Volt 4 wire AC 50 Hz cubical, factory made Out door type,IP54 , weather and vermin proof fabricated out of 3.15 mm thick CRCA MS sheet and angle iron frame 50 x 50 x 6 mm with bus bar chamber, cable alley and in built sheet metal cubicles to mount / accommodate all electric control accessaries including hinged outer panels with locking arrangement on both front and rear sides of the panel board including preparation and providing powder coating to both exterior and interior steel surfaces with approved tint and shade complete with lifting hook and angle iron legs, suitable cable gland for all incoming and out going cables including fixing the panel board 45 cm above ground level by providing 60 cm long angle iron legs of size 50 x 50 x 6 mm welded on all four corners and embedded in PCC (1:2:4) type C-2, using 20mm graded aggregate upto a depth of 30 cm below surface level complete all as specified and directed. ( The panel board shall comprise the following items:) INCOMING (a) 4 Nos bus bar high conductivity copper alloy properly insulated of rating 200 Amps and mounted on porcelain insulator supports. (b) MCCB 4 Pole, 415 Volts AC, 16 KA, 100 Amp - 01Nos (c) Change Over Switch 100 Amps 415 Volts -01 Nos (d ) Indicator lamps ( Red , Yellow and Blue ) (e) Voltmeter and Ammeter OUTGOING (a) MCCB 63Amps 16 kA , 4 Pole -02 Nos (b) MCB TPN 63 Amps - 02 Nos (c) MCB SPN 32A 16 KA - 04 No
Material and Labour for refrigerant piping from indoor to outdoor of required size of dia 3/4" and 3/8" for Suction and discharge of refrigerant with nitrile rubber insulation duly wrapped complete all as specified and directed
M&L cement concrete (1:3:6) type C-2 using 40mm graded aggregate in foundation, filling and mass concrete.
M&L for steel work in tubular trusses /posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 - 1979 graded SI 240.
Material and labour for providing cement concrete 1:2:4 type B-2 using 40 mm graded stone aggregate in copings to poles & the like including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 15 KVA complete all as specified and directed .
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA complete all as specified and directed .
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.50 mtr in depth for taking out /laying of CI/GI Pipe Lines etc., forming bottom surfaces of trenches to required level and gradient and getting out in soft/ loose soil complete all as specified and as directed by Engr-in charge.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil, including providing heaps along the trenches with surplus soil, complete all as specified and as directed by Engr-in charge.
Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M & L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed.
Supply & Laying well burnt brick , locally available best quality (sub class "B" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified.
S & F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed.
Supply & laying incl replacement of XLPE LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 25 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & laying incl replacement of XLPE LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 35 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
M & L for earthing to DG set and panel complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, using galvanised iron strip 32×6mm as earthing lead buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel wire of diameter 4.0 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 15 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed by engineer- in- charge.
Supply and fixing of GI strip 32 x 6 mm fixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode duly brazed over epoxy electrical insulators complete all as specified and directed
M&L in replacement for earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to Copper strips 20X3 mm by means of copper nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed. NOTES : The unit rate includes for protection pipe and Copper strip from top of earth plate up to 7.00 meter above ground level.
S& F in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over epoxy electrical insulators or any other indicated situation for loop earthing etc as required with 20 x 3mm copper strip duly brazed complete all as specified and directed.
Material and labour for point wiring with 2.5 Sqmm PVC insulated multi stranded copper conductor FRLSH cable 1100 Volts grade single core conforming to IS-694-1990 and one run of continous earth wire with 2.50 Sqmm stranded core PVC insulated sheathed copper conductor cable draw in & including PVC surface casing ‘N’ capping 25mm/32mm wide double lock type to be fixed with the help of rawal plugs & screws including necessary fittings & fixtures and including PVC terminal box and PVC board of suitable size including making good disturbed surface with CM (1:4) to match with the existing surfaces complete all as specified and directed
S&F Switch socket combination (White) 2 in 1 5/6 pin, 15 Amp flush type universal.
Supply, install of wall mounted Automatic voltage stablizer ,Copper Wound naturally air cooled , single phase , input voltage range 90-290V, Output Voltage range 230V± 5%, AC with digital display of Capacity 2KVA complete all specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA
Supply, install of wall mounted Automatic voltage stablizer ,Copper Wound naturally air cooled , single phase , input voltage range 90-290V, Output Voltage range 230V± 5%, AC with digital display of Capacity 1 KVA complete all specified and directed.
M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, cleaning and stacking bricks removing surplus serviceable bricks, hard-core etc to store and rubbish not exc 50m complete all as specified and as directed.
Supply and fix Deep Freezer Glass Top electric driven (single phase), capacity 320 Litres.BEE 5 star rated complete all as specified and directed
Supply and fix Refrigerator electric driven (single phase), capacity 310 Litres.BEE 5 star rated complete all as specified and directed
Supply and fix Refrigerator electric driven (single phase), capacity 180 Litres.BEE 5 star rated complete all as specified and directed
Supply and fix Refrigerator electric driven (single phase), capacity 245 Litres.BEE 5 star rated complete all as specified and directed
Supply and fix Deep Freezer Metal Top electric driven (single phase), capacity 500 Litres.BEE 5 star rated complete all as specified and directed
Supply and fix in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR capacity all as specified and directed.
S&F Nitrile Rubber insulation for copper tubing of size 1/2'' dia duly wrapped complete all as specifed and directed.
S&F Nitrile Rubber insulation for copper tubing of size 1/4'' dia duly wrapped complete all as specifed and directed.
M/s JK Jangid and Company (BID ID -3374283)
United Traders (BID ID -3374841)
RS COOLING APPLIANCES (BID ID -3374015)
M/s Ravi Enterprise (BID ID -3374839)
SNEH CORPORATION (BID ID -3373142)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .