Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.0 CrAccepted-AOC OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | ₹9.0 Cr Quoted ₹9.1 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹9.3 Cr+₹26.8 L (2.95%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹9.3 Cr+₹26.8 L (2.95%) | L-2 | Rejected-Finance Other Than L-1 Bidder. |
| 3 | L-3₹9.5 Cr+₹45.7 L (5.04%)Rejected-Finance | ₹9.5 Cr+₹45.7 L (5.04%) | L-3 | Rejected-Finance Other Than L-1 Bidder. |
| 4 | L-4₹9.8 Cr+₹78.0 L (8.60%)Rejected-Finance | ₹9.8 Cr+₹78.0 L (8.60%) | L-4 | Rejected-Finance Other Than L-1 Bidder. |
| 5 | L-5₹9.9 Cr+₹82.6 L (9.11%)Rejected-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹9.9 Cr+₹82.6 L (9.11%) | L-5 | Rejected-Finance Other Than L-1 Bidder. |
Tender Value
₹10.9 Cr
EMD Value
₹8.7 L
Closing Date
9 Nov 2022, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
ADDITION / ALTRATION AND SPECIAL REPAIR TO HOSPITAL BUILDINGAND CES AT 164 MH BINNAGURI UNDER GE (S) BINNAGURI
2022_MES_555436_1
98753/BIN(S)/SZ/E8 (CA No. CESZ/BIN(S)/18 OF 22-23
Open Tender
Civil Works
Item Rate
540 days
BINNAGURI
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
GE (S) BINNAGURI
₹8.7 L
Yes
HQ CE SILIGURI ZONE
7 Dec 2022
30 Sept 2022
16 Nov 2022
30 Sept 2022
9 Nov 2022
28 Oct 2022
1 Oct 2022 - 11 Oct 2022
14 Oct 2022
Amount
STRUCTURAL REPAIR ITEMS Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) e.g. FINS/FACIA/SUNSHADE/FACADES etc of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S&F for Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately.
M&L for Removing and Hacking of existing deteriorated damaged & loose concrete from the external surface of the structure carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete or control sand blasting including cleaning the surfaces by air jet etc, complete and also without damaging the existing structure.The rate shall also include disposal of waste/rubble/malwa from site outside MD Land upto as directed by the Engr-in-Charge along with lead and lift if any including standard steel scaffolding upto a height of 11 M. Note : The above treatment will be done in presence of company authorised person and also company skilled workers.
M&L for Providing and applying ‘Rusticide SS’ Rust passivator or equivalent as specified in the Brand Names to existing r/f. bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directed Providing and applying “Polyalk EP” or equivalent as specified in the Brand Names.Polymer modified cement mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering.
M&L for Opening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
M&L for Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of “Polyalk EP”and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks /Grooves by Providing and applying “Polyalk EP” Polymer modified cement mortar (or equivalent as specified in the List of Brand names) in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed.
M&L for Drilling holes of required size upto 16 mm Diameter and up to 50mm depth in concrete and cleaning the same as directed.
M&L for Providing and fixing 12 mm diameter aluminum /PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of ‘Fosroc’ at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
M&L for Identify the cracks and construction joints, honeycomb areas, shall be chased open into 'U' groove shape and sealed with High strength, abrasion - resistance epoxy reinstatement mortar, Fosroc Nitomortar S or Equivalent, Providing and fixing 6-8 mm dia nozzle along the joints and honeycomb areas after proper surface preparation. The injection of Conbextra EP10 or Equivalent through the nozzle till the refusal of the grouting materials.
M&L for Drilling holes in existing concrete, Providing & fixing FHP-10 Tubes in hole for fixing new reinforcement rods up to 4” depth (upto maximum dia of 16mm) in existing concrete elements and sealing the same hole with polymer mortar after fixing the new rod as per Consultants Instructions and directions
M&L for Providing & fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing, Micro concreting as per Consultants Instructions and directions.
M&L for Providing, cutting, bending and fixing Additional Reinforcement in position steel reinforcement of specified/required sizes and shapes in the form or main rebars, stirrups & rings, distribution rebars etc., and tying them to shear connectors using GI binding wire. The additional rebars should be coated with TWO coats of Anti Corrosive protective coating & dry sand to be sprinkled on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants.
M&L for Providing, erecting, fixing in position waterproof shuttering by plywood/MS sheet 2.5 to 3.00 mm thick to be fixed with required size of angle frame who can bear the pressure load of concrete during pouring at all locations for all shapes with chamfers, splays, keys wedges, props, bracings, nails, brackets, etc complete including providing, erecting & removing of pipe scaffolding at requried height conferming to relevant IS codes, de shuttering of the same after specified period without damaging the concrete works as directed by Engineer-in-charge, etc.
M&L for providing and laying of ready to use non shrink ,cementitious free flow micro concrete, upto required thickness at the designated areas, to the prepared slurry tight shuttering with proper shear connectors and bonding agent where ever necessary .The fluid Micro-concrete repair material shall be single component , cement based to which only site condition of water and approved graded coarse aggregate where ever specified shall be permitted . The micro concrete shall contain no mettalic aggregates or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete in the flowable consistancy should achieve a compressive strength of 50 N/ Sq.mm after 28 days at 30 degrees Centigrate as per BIS 4551-80.The unrestrained expansion shall be between 1-4 % as per ASTM C827 -1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/ Sq.mm @ 28 days. The Micro Concrte shall have a coefficient of thermal expansion 10-12 x 10 -6 /oC and thermal conductivity 1.50 W /moC . The mixed density of micro concrete shall exceed 2100-2200 Kg/Cu.M 227oC including standard steel scaffolding upto a height of 11 M Note : The above treatment will be done in presence of company authorised person and also comapany skilled workers. Make of non shrink ,cementitious free flow micro concrete :- Renderoc RG of FOSROC or Equivalent.
Providing and laying in slabs, beams, pardis,chajjas RCC wall etc position of RCC M-25 design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering, shuttering, form work, finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.The Mix design as per particular specfications shall be got approved by Engineer-in-Charge before execution of the item.The rate shall include cost of all specified materials and operations at all levels and heights, including the cost of centering, shuttering and form work excluding reinforcement which shall be paid under relevant item.(Note :- Cement content considered in this item is @ 300 kg/cum as per IS 456 table showing minimum cement content. No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled concrete)
Providing & laying applying Glass Fiber sheet wrap at structural members including.Surface Preparation: Grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.Profiling: Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc., complete.Wrapping: Wrapping the Glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., Repeat the same procedure for multiple layer with interval of 8 hours.Sand Pasting: Applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement: Per Sq.Mt of Fiber consume and not application of surface area.)
M&L for Carefully opening of the existing joint, thoroughly cleaning, Providing and applying 2 component Polysulphide sealant at expansion joints with backing rods up to 50mm thickness inclusive of all necessary cleaning of the joints, surface preparations etc all complete as per consultants instructions,directions and manufacturer's specifications.
M&L for Carefully demolishing existing Coping/ Stone etc , Brick walls above Horizontal Expansion joints at terrace floor & recasting the RCC Pardis in M20 (1:1.5:3) etc all complete as per consultants design and drg including Providing and applying 2 component Polysulphide sealant of BASF or equivalent etc complete as instructed and directed
M&L for 25 mm thick( Average thickness) Guniting concrete surface using mechanical means with single component, shrinkage controlled, polymer modified, fibre reinforced structural grade cementitious repair mortar having compressive strength of 45 N/ Sq.mm , Flexural strength of 7 N/Sq.mm and tensile strength of 2.50 N/sq.mm at 28 Days all as per manufacturer's recommendation and technical specification and as per the direction of Engr-in-Charge including standard steel scaffolding upto a height of 11 M Note : The above treatment will be done in presence of company authorised person and also company skilled workers. Make of single component, shrinkage controlled, polymer modified, fibre reinforced structural grade cementitious repair mortar : Renderoc SP 40 from FOSROC or Equivalent.
M&L for Carefully Chiseling/ Chipping out all existing loose decayed Plaster of External Facades and Terrace area (In Entire areas) using Plaster Breaking machine and or Well sharpened Chisel & Hammers at proper angles carting away the Debris outside of bldg Premises etc complete as directed by the Consultants,Providing and applying 20/25 mm thk sand faced plaster to concrete members- brick work etc.of External wall facades using approved screened and Pre washed River sand including base coat of 13-15mm thick in C.M. 1:4 and curing the same for not less than three days and keeping the surface of base coat rough to receive the sand face treatment 6 to 8 mm thick of C. M 1:3 finishing the surface by taking out grains and curing for 7- 10 days, providing and mixing approved waterproofing compound in required quantities in both the coats complete.
BUILDING REPAIR ITEMS M&L cutting out crack to v-section in existing roof of terrace cleaning out wetting grouting with cement sand slurry 1:3 complete all as specified and directed.
Taking down tar felt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed .
M & L screed bed or bedding layer 15 mm thick screed bed or bedding layer in CM (1:4) mixed with WPC as per manufacturer instruction for laying of APP membrane complete all as directed by the Engr-in-Charge.
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed
M& L for bituminous primer @ 0.50 KG/Sqm over the cement plaster incl preparation of surfaces as per manufacturers instruction complete all as specified and as directed by the Engr-in-Charge.
M & L APP based polymeric membrane minimum weighing 3kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm) land on primed surface by forced application complete all as specified and as directed by Engr in Charge.
M & L for finishing the Bituminous surface with aluminium paint @0.15 Ltr/Sqm as per manufactures specifications and under strict supervision of manufactuer's technical representative complete in all respects as directed by Engr-in-Charge
Disconnectiong existing PVC water tank including GI pipe inlet/outlet of any dia complete all as specified,PVC tank having capacity excedding 500 ltrs but not excedding 1000ltrs setting aside (or lowering if required) and hoisting,reconnected old GI pipe with tank and refixing PVC tank in same position complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc
M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 5mm thick in CM (1:3) on fair faces of concrete surfaces as in celling finished fair and even without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying 2 mm thick wall care puttyand thereafter two coats of exterior emulsion paint white or tinted over a coat of primer complete all as specified and directed.
M&L for complete removal of exsiting treatment on wall surfaces any type by vigorously wire brushing brooming, dusting & finally washing with water to clear the cracks absolutely free from any kind of existing finishes & foreign materials, making good surface applying 2 mm putty and two coats of exterior emulsion paint(Weather coat) white or tinted over a coat of complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of primer over 2 mm wall care putty on newly plastered wall surfaces including prepation of surfaces complete all as specified.
M&L for applying two coats of distemper oil emulsion over a coat of primer over 2 mm wall care putty on newly plastered ceiling surfaces including prepation of surfaces complete all as specified.
M&L for preparing old plastered surfaces of wall and applying 2 mm putty and two coat of distemper oil emulsion over a coat of primer complete all as specified.
M&L for preparing old plastered surfaces of ceiling and applying 2 mm putty and two coat of distemper oil emulsion over a coat of primer complete
S&F 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down old pipes with fittings complete all as specified and directed
S&F 110mm bore PVC(SWR) bends .
Demolition of brick masonary work, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding precast concrete articles etc. complete all as specified and directed.
M&L for brickwork with old size fly ash sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete directed by Engr-in-Charge.
M&L for brickwork with old size fly ash sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
S&F for pre-coated galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F for pre-coated galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling wrought iron or mild steel work of any description as in door, gates etc and similar works complete all as directed by the Engr-in-Charge.
S&F steel work in tubular trusses i.e. Truss bottom, top bend, sides, side supports, holding plates, posts and base plate with bolt for joining with stud column etc including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and as directed by the Engr-in-Charge.
M& L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges of 1:2:4 of B0 complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection and footpath finished even and smooth without using extra cement, including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight including formwork complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in flooring and finished the surface even and smooth without using extra cement at ramp etc including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and as directed. complete all as specified and as directed by the Engr-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engr-in-Charge
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channels and drains etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm -- Ditto -- (for adjustment of girth only)
M& L for Surface dressing n exc 15 cm deep for adjoining area complete all as specified and directed
Removing excavated material exc 1.5 km n.exc 5 KM and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 4mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50Sqm in each pane including hacking out old one complete all as directed.
Supply & fixing in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel staples including taking out old one all as directed by the Engr-in-Charge.
Dismantling of Ceiling Board of any description and any thickness including Cover Fillets, Cornices, etc complete all as specified and as directed.
Supply and fix in repair galvanized steel tubing medium grade, 40 mm bore with all fittings and fixed complete to walls and ceiling all as specified and as directed.
Supply and fixing in repairs for aluminium anodised snap grid (605X605mm size) to support the boards / tiles with aluminium Tee section 35 mm x 25 mm x 1.40 mm, cross Tee 23.50 mm x 23.50 mm x 1.40 mm and aluminium angle 25 mm x 25 mm x 1.40 mm as on edge / sides including proper hanging arrangement with 4 mm dia anodized galvanised iron wire with false ceiling iof 4 mm thick E board classic for insulation and accoustic purposes of size 600X600 mm fixed with necessary accessories to frame work or with staples on snap grid upto ceiling proper scafolding arrangementsand with complete all as specified and as directed by the Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe of 100 mm and rendering, cutting outexisting benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 typeB-l smooth finished, and reforming benching as required
Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material exc 1.5 km n.exc 5 km and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up of old existing leakage/broken drain pipes (SGSW/AC/PVC) set in cement mortar of size 150mm dia bore including PCC packing under and haunching against the sides of bottom pipes complete all as specified and directed.
S/F for SGSW drain pipe of size 150 mm dia (grade A) laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded aggregate) as in bed to drain pipes of size 150mm dia bore including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and directed
Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded aggregate) as in coping of manholes channels etc complete all as specified and directed
Supply and fixing for mild steel TMT bars, 8mm dia, cut to length, bent to shape as required including cranking, bending and binding with mild steel wire (annealed)not less than 0.90 mm dia complete all as specified and directed.
M & L for precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in cover slabs of drains set in CM (1:6) including necessary form work complete all as specified and as directed by the Engr in Charge.
Taking down chowkets or frame with shutter (without taking off shutters from the frame) n.exe 1.5 Sqm each complete all as specified and as directed by Engr-in-Charge.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and as directed by Engr-in-Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat mould plain coloured PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement all as specified and directed.
S&F of factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F Aluminium anodized barrel tower bolts, extruded section 200mm long.
S&F Aluminium anodized handles, D type, 150mm long
S&F in aluminium sliding door bolt 300 mm long, plate type, stove enamelled black, with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate.
S&F Stainless steel butt hinges medium weight 100mm long for PVC door.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes
S&F in replacement for CP curtain rod 25 mm dia with socket storeyed bldg including taking out old one complete all as specified and as directed by Engr-in-Charge.
M&L in repair for 12 mm Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work if fixed in pelmet boxes or in narrow widths nexc 15cm each, rebated or flat edged
Supply and powder coated (minimum 50 micron) anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates with stainless steel screws /including PVC protector sheeting and joining cleat for fixing etc. including taking down old one complete all as specified and as directed by Engr-in-Charge.
Supply and fixing powder coated aluminium sliding window sliding on 3 tire frame of section 92mm X30mmX1.55 mm and shutters of section 20 mm X 40 mmX 1.55 mm fixed with 4 mm thick plain glass with rubber gasket, handles lock, 'U' channel with provision for aluminium grill fixed with aluminium frame etc all as specified and directed by the Engr-in-Charge.
M& for fabrication and fixing of anodised aluminium door shutter fixed with rubber gasket, stopper, cleats, handles etc complete for aluminium frame of size 101.6mm x 44.45mm x 2mm and section of bottom and top rail of section114mmx44.45mmx2mm thick and and lock rail shutter frame of 83mm x 44.45mm x 2 mm with and including panels of 5.5 mm thick plain/frosted float glass,and with anodised aluminium snap beading of size 18.2mmx16.66mm scred for fixing fully including double action door spring hydraulically regulated made up of 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and all necessary fittinngsand EPDM rubber packing each shutter shall be provided with two decorative type aluminium disc handle of 150 mm dia per shutter ,1 no heavy duty door shutter 1no 200mm long aluminium tower bolt per shutter including complete all as specified and as directed by the Engr-in-Charge.
S&F Door closer (Aluminium die cast body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed by the Engr-in-Charge.
Supply and fix 4.8 mm thick Sheet glass,ordinary quality in aluminium windows with stainless steel screws complete all as specified and as directed by Engr-in-Charge.
S & F Framed work such as grills, gratings,agles etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of steel surfaces over exc 10cm girth complete all as specified and directed.
M&L PCC (1:3:6) type C1 as in holdfast block, coping, bedblock etc.
S&F factory made Z section steel window with side hung shutter frame including projecting/ box type hinge with steel handle and steel peg stay, ms tower bolt etc. complete with glazing bars , dovetailed or welded including a shop coat Red Oxide priming complete all as specified and directed.
S&F factory made Z section steel window with side hung shutter frame including projecting/ box type hinge with steel handle and steel peg stay, ms tower bolt etc. complete without glazing bars , dovetailed or welded including a shop coat Red Oxide priming complete all as specified and directed.
S&F factory made Z section steel ventilator with top hung shutter incl hinges, steel peg stay, with glazing bars including a shop coat Red Oxide priming incomplete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete
M&L preparing old painted wooden surface of any description not otherwise described for over 10 cm width or girth and applying one coat of synthetic ennamel paint complete all as specified and directed.
M&L preparing old painted steel surface of any description not otherwise described for over 10 cm width or girth and applying one coat of synthetic ennamel paint complete all as specified and directed.
M& L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges of 1:2:4 of B0 complete all as specified and directed
S&F in repair 0.56mm thick plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)
S&F in repairs vitreous china wash down water closet pan (Eeuropean type), white including white plastic seat cover with mild steel CP hinging device fixed complete jointing connecting and making good the disturbed.
S&F in repairs vitreous china wash basin 550 x 400mm size white including brackets, CP waste coupling waste pipe, short connection complete all as specified and directed.
S&F in repairs sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 mm x 420 mm bowel size 410 mm x 330 mm x 160 mm.
Taking up or down steel tubing and connections,15mm bore including cleaning for serviceable pipe for re-fixing or removal of unserviceable pipe from site of work complete all as directed.
All as per item No.103.00 here-in-above but 20mm bore.
All as per item No.103.00 here-in-above but 25mm bore.
S&F steel tubing, medium grade, 15mm bore with all fittings fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
All as item No 106.00 here-in-before but 20mm bore.
All as item No 106.00 here-in-before but 25mm bore.
S&F in repair bib taps, fancy type chromium plated with crutch or butterfly hadle screwed down, screwed for iron pipe or brass ferule of 15mm bore complete all as specified and as directed.
S&F in repair stop valve, fancy type, chromium plated (medium) screwed down,high pressure with crutch or butterfly handle,screwed both end for ironb pipe or for union of 15mm bore complete all as specified and directed.
S&F in repairs 15mm pillar tap,cast copper alloy, with capstan head, chromium plated, fancy type screwed down high pressure,with or without lettered "hot" or "cold" with long screwed shank and fly nuts screwed for iron pipe of 15mm bore complete all as specified and as directed.
S&F in repair 125mm dia chromium plated shower rose including arm with swivel joints including fixing to steel pipe or union.
S&F in repair PVC flushing cistern symphonic action type,10 ltrs capacity,low level white with inlet ball valve,float and handle including bracket including flush pipe complete.
S&F in repair 15mm bore PVC connection pipe 450mm long with PTMT nuts at bolt ends.
S&F in repair CP towel rail, 20mm dia, 600mm long including brass CP brackets. complete.
Fixing only rotational moulded PVC water storage tank 1000ltrs capacity conforming to IS-12701(1989) cylindrical vertical type multi-layered with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I
S&F 25mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms)
S&F welded steel wire fabric not exceeding 4 Kg, size and shape as approved by GE complete all as specified and directed.
S&F mild steel section joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) Fe-290 (Gde E-165) complete all as specified and directed.
S&F flat iron bands, straps, clamps including all necessary drilling, bolting or reviting etc conforming to Fe-290, Gde E-165 complete all as specified and directed.
Dismantling floor, hearth wall tiling incld cement mortar bedding (but not backing) removing servicable tiles to store & rubbish off the premises.
S & F coloured Non-skid Ceramic tiles, joint free, 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors, skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tiles. 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes.
M & L for glazed ceramic colour tiles 450X 350X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile 10mm thick rendering on fair faces of brick work or concrete surface in CM 1:4 for laying wall tiles. approved by Engr-in-Charge complete all as specified and directed.
M&L for coloured joint free non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors, skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including 15mm thick screed bed in cement mortor 1:6 complete all as specified
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors, skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortor 1:6 complete all as specified
INTERNAL ELECTRIFICATION Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, modular type sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with modular frame for housing modular type switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- Item Continued as 128.00 to 134.00
(a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan point controlled by one way switch 5/6 amps.
(c) One Exhaut fan point controlled by one way switch 5/6 amps.
(d) One socket out let 5/6 amps point on the same board
(e) One socket out let 5/6 amps point on the independent board
(f) One bell/buzzer point controlled by one bell push button
(g) One light point controlled by two two way switch 5/6 amps.
All as per item No. 127 here-in-before but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F Modular switch 1 way 6A,1 module single pole complete all as specified and directed.
S&F of Modular switch 2 way 6A,1 modules single pole complete all as specified and directed by Engineer -in-Charge.
S&F modular socket 2 /3 Pin combined 2 module, 6 amps, complete all as specified and directed.
S&F modular socket 2 /3 Pin combined 2 module, 6/16 amps, complete all as specified and directed.
S&F Modular switch 1 way 16A,1 module single pole complete all as specified and directed.
S&F modular bell push 6 amps 1 module complete all as specified and directed.
S&F Modular white cover plate with frame 1 module complete all as specified and directed.
S&F Modular white cover plate with frame 3 module complete all as specified and directed.
S&F Modular white cover plate with frame 6 module complete all as specified and directed.
S&F Modular metal flush box 1/2 module complete all as specified and as directed
S&F Modular metal flush box 3 module complete all as specified and as directed
S&F Modular metal flush box 6 module complete all as specified and as directed
S&F of call bell buzzer AC Single pole 220/240 Volts, surface type complete all as specified and directed.
S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed.
S & F lamp holder, isolated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S & F modular fan step regulator 120 W, 2 module complete all as specified and directed.
S&F, IP 20, class I, LED tube light fittings 20W (or nearest next higher wattage) (4feet), wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. Make : Syska, Model No. SSKALB20W or equivalent in Philips, crompton
S & F LED street light fittins 30 watt in aluminium PDC housing, toughned glass cover with IP66 protection complete all as spedified and as directed. (Make – Make : Syska, Model No. SSKSLFCF30W or equivalent in Philips, crompton
S&F in repair Decorative luminiare suitable for wall light fixture including LED lamp 1x10/15 watt ( B-22 base) ,made of unbrakeable Polycarbonate with Acrylic decorative diffuser, IP-65 protection, and provision of PVC insulated sheathed round flexible wire with multi stranded copper conductor of size 2.50 Sq mm two core complete all as specified and directed Make : Havells, cat part No.LHDL06160099 or equivalent of Philips/Bajaj.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Tripple pole & neutral with 200 amps rated bus bar, IP-20 protection, including four pole MCCB 63 Amps with blanking plates complete all as specified and directed.
S&F MCB (Isolator), Triple pole & neutral, 40 amps, 415 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCCB 100 amps 4 pole adjustable thermal & fixed magmetic setting four pole 415 volt 50 Hz with breaking capacity 10 KA including taking down the old one complete all as specified and directed by Engr-in-Charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. all as pecified and as directed
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge.
M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. .
M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduit of size 32 mm medium grade size, making good the disturbed surfaces complete.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. .
M&L for street light bracket made out of GI pipe light grade 32 MM dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling hole, fixing with runts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer.
Taking out Sheet metal enclosure of 12/8/6/4/2 way Distribution Boards from its original position and refixing after the B/R work /or any directions by engr-in-charge at the existing place complete all as specified and as directed.
Takingout serviceable LED tube light fittings of any watts & any discription from its position and Refixing after B/R plaster work complete all as directed by Engineer-in-Charge.
Takingout Ceiling/ExhaustFan of any sweep from its position and Refixing after B/R plaster work complete all as specified and as directed.
Takingout Geyser of any capacity from its position and Refixing after B/R plaster work complete all as specified and as directed.
Supply & installation of nursing calling bell system wireless display with 2 digit, dynamic, upgrade display. Queue system enabled 2 Nos and Calling unit wall mount RESET switch and call switch (1.5 mtr bed cord) 50 Nos for patients all as specified and as directed
Supply & installation of 3 digit token display system with wireless input device for OPD all as specified and as directed
M&L for earthing complete with Galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI strip 32x6 mm thick as earthing leads by means of bolt, nut, check nuts and washers galvanised iron or steel all as shown in elctrical plate No 5 of SSR Part I connected to earthing test point or as specified or indicated and testing on completion including excavation and earth work, PCC pit with RCC cover having suitable handle, 32mm bore GI Medium grade watering pipe with funel and wire mesh, 15 mm dia GI Light grade Protection pipe complete.
Refixing only for dismantling/refix the existing dislocated/fallen air termination rods 300mm long,12 mm dia fixed on PCC blocks/on GI pipe/ directly on roof including GI pipe etc, complete after complete the roof treatment work of B/R than refixing the same existing place including taking down all as specified and as directed .
Refixing only for dismantling /refix the inspection boxes/ test points of any size /type complete after complete the roof treatment work of B/R than refixing the same existing place including daking down all as specified and as directed
S&F Aluminium Strip 25 x 3 mm with saddles & fixing screws etc,for earth continuity conductor main earthing lead , wall conductor & down conductors above ground suitably fixed to wall or concealed in wall , or passing through pipes incl. all necessary fixing arrangement for lightning protection complete.
S&F galvanised iron strip of size 32 x 6 mm buried in ground or fixed on roof of suitable sized porcelain insulators (on roof and wall only) including cutting cavities for fixing of porcelain insulators and finishing with cement plaster on wall /floors and connected to test point including bending, jointing at test points with GI nuts, bolts, with lead washers, jointing strips at all joints incl. making good the disturbed surfaces complete.
Fixing only in repairs Aluminium Strip 25x3.15 mm any size with saddles & fixing screws etc,for earth continuity conductor main earthing lead , roof conductor & down conductors above ground suitably fixed to wall or concealed in wall , or passing through pipes incl. all necessary fixing arrangement for lightning protection complete after complete the roof treatment work of B/R than refixing the same existing place including taking down all as specified and as directed.
Fixing only in repairs GI Strip 32x6mm any size with saddles & fixing screws etc,for earth continuity conductor main earthing lead , roof conductor & down conductors above ground suitably fixed to wall or concealed in wall , or passing through pipes incl. all necessary fixing arrangement for lightning protection complete after complete the roof treatment work of B/R than refixing the same existing place including taking down all as specified and as directed.
S&F air termination single pointed aluminum rod of 12mm dia, 300mm long fixed with 02 nos sutable sized nuts,bolts & washers incl. making good the disturbed surfaces complete.
S&F in repair of test point terminal block made of gun metal or phosphorous Bronze 75x75x 25 mm dilled and screwed incl 3 Nos 8mm dia 50 mm long hex head screws rectangular opening at top and bottom for entry of down earth strip, fixing screws and bolts for mounting on wall.all as specified.
S&F suitable sized heavy duty bridge/post porcelain/mini busbar insulator on wall / roof with suitable size of PVC plugs / gutties,screws for fixing aluminium / GI strip incl. making good the disturbed surfaces complete.
M&L for PCC in foundation, for filling of road,in plinth protection,as in bed plates for fixing of aluminum strip etc in PCC (1:2:4) type B -1 with 20 mm graded stone aggregate complete.
M&L for GI Pipe medium grade 40 mm dia for fixing of air termination single pointed aluminum rod of 12mm dia, 300mm long on the roof of builings for effective lightning protection system incl. PCC for fixing complete to the satisfaction of Engr -In - Charge. MAKE : JINDAL / TATA.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 TR with complete accessories all as specified and as directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm.
Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level.
Material and labour for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I)
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge.
Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed.
LIFT Dismantling of existing BER lift at 164 MH complete with dismentling of all machine room equipements , like , motor , gear , machine beam , controller , over speed governor , wire ropes , electrical cables and wires , all lift shaft equipements , car body , car sling , counter weight sling , counter weights , door , door frames , counter weight guides , guide brackets , car and counter weight buffer springs etc and depositing to MES store yard including transporting complete all as directed.
(h) Car Door: Automatic centre opening with V3F door drive sliding type , stainless steel , hairline finish (N-304) for car and landing doors at all floors. (j) Car Enclosure: Standard manufacturing with MS frame & stainless steel hairline finish (N-304) in standard thickness with sleek circular lLED light fitting on ceilling of appropiate type/size/wattage and concealed axial flow fan with stainless steel grill. (k) Terminal buffers : Special spring buffers. (l) Door opening (Inside) : 1300 x 2286 mm (Full size) (m) Counter weight shall be of cast iron as recommended by OEM. (n) Car and counter weight guide : Existing and as per OEM. (o) Clear Hoist Size : As per OEM.(Bidder shall inspect the same at site before quoting) (p) Flooring : Stainless steel chequered plate of appropriate thickness. (q) Signals :- (i) Combined Luminous hall buttons with VFD hall position indficators at all floors. (ii) Vacuum filled Display (VFD) for car position indicator of stainless steel. (iii) One No. car operating panel with luminous buttons in car. (iv) Car direction indicator in car and landing. (v) Battery operated alarm bell and emergency light (rechargeble) alongwith suitable maintenance free battery. (vi) Overload warning feature in car cabin. (vii) Fireman's switch 01 No. per lift to be installed at Ground Floor near landing door. (viii) All signal fixture and car operating panel on stainless steel face plate. (ix) Full height standard infra red door sensor with 154 criss cross beams. (x) Built in announcing system without hand set , 03 Nos. one each for car , Ground Floor and macine room and one hand set in machine room. (xi) The interior of the car should be provided with a device that audibly indicates the floor lift has reached and indicates that the car entrance/exist door is opened or clossed. Item Continued as 195.00
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 core
Taking down carefully of insulated GI sheet of rectangular shape made out of L shaped hollow profiled including all accessories such as corner, cleat, carriage with gasket and refixing the same after B/R work with all accessories like clamp, nut-bolt gasket etc with appropriate sealant on longitudinal joints etc complete all as specified and directed.
Taking down carefully pre-insulated MS pipe Class 'C' having thickness of PUF insulation 33 mm of density 36 Kg/Cum and 26 gauge GI cladding complete and refixing the same after B/R work with all accessories like clamp, nut-bolt gasket etc complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for supporting AC duct complete all as specified and directed.
M&L for duct insulation with resin bonded fiber glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c ) M&L for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide to make the insulating leakproof. (d) M&L for securing the insulating with and including mechanically fastened nylon / steel straps of size 12mm / 50 mm at maximum intervals of 1.2 mtr.
Material and labour for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized iron strip 32×6mm as earthing lead by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge.
Material and labour for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge.
Supply install testing commissiong and testing of febrication of LT indoor 5 segment cubical pannel board with vertical bus chamber made by CPRI approved fabricator of suitable size made of 2.00 mm thick CRCA sheet and framing with 40X40X6MM angle iron floor mounting type with 300 Amp copper bus bar, powder coated painted including intrnal wiring complete providing suitable of size copper cable / strip as required or as per manufactuter's reccommendation with followinf accessories:- INCOMMING :- (a) MCCB 4 Pole 415 Volts, 100 A, 25 Ka - 01 No (b) Digital single function volt meter - 01 No (c ) Digital single function Amp meter - 01 No (d) LED indicator Lamp R-Y-B -01 set OUTGOING:- (a) MCCB 4 Pole 415 Volts, 63 A, 16 kA - 02 No (b) TPN 63 Amps
Supply and fixing vertical load line DB TPN fitted with bus bar neutral link wit following accessories :- INCOMING :- (a) MCCB 4 Pole 415 Volts, 63 A, 16 kA - 01 No (b) MCCB 4 pole 415 Volts, 40 A, 16kA - 01 No (c) Digital single function volt meter (0-500) as per l&t price list - 01 No (d ) Digital single function Amp meter as per l&t price list - 01 No (e) LED indicator Lamp R-Y-B -01 set OUTGOING:- (a) MCCB 4 pole 415 Volts, 32 A, 16kA - 01 No (b) MCB 2 Pole 16 A -04 No (c) MCB SP 6 A -04 No
SCHEDULE OF CREDIT DEDUCT Credit Amount B/F from Serial Page No. 22 against Schedule of Credit
M/S R. K. INDUSTRIES
M/s NLM INFRA PROJECTS
MS SHRI B.C. DAS
M.P. SITANI AND SONS
M/s KACHO BHUTIA
VARNI BUILDERS
B D Raizada Projects Pvt Ltd
MAHENDRA REALTORS AND INFRSTRUCTURE PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_621540.xls
BOQ Document • 0.61 MB
106238057.pdf
Tender Document • 0.41 MB
98753_BIN.PDF.rar
Tender Document • 5.42 MB
106238062.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .