GEMC-511687723855352
Awarded to GANIT STAR ENGINEERING
₹10.5 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 300w Flood light | GANIT & SLIM-300W | - | 200 NOS | ₹5,245 | 1,049,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.5 LQualified Make: GANIT
Model: GANIT & SLIM-300W 32 35 SINHASA IT PARK DHAR ROAD INDORE MADHYA PRADESH 452013 | INDORE | MADHYA PRADESH | 452013 | Make: GANIT
Model: GANIT & SLIM-300W | ₹10.5 L | L1 | Qualified |
| 2 | L2₹11.4 L+₹91,000 (8.67%)Qualified Make: Ascentech
Model: AT_FL_300 ASCENTECH LIGHTENING SOLUTION PLOT NO 150 151 A HSIIDC INDUSTRIAL AREA NEAR HSIIDC BUILDING SEC 59 BALLABGARH FARIDABAD HARYANA 121004 FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | Make: Ascentech
Model: AT_FL_300 | ₹11.4 L+₹91,000 (8.67%) | L2 | Qualified |
| 3 | L3₹11.5 L+₹1.0 L (9.61%)Qualified Make: ACROMAX LITES
Model: AIPLLEDFLF300W-IP65 B 79 T F FLAT NO 1 DUGGAL COLONY KHANPUR KHANPUR DUGGAL COLONY NEW DELHI DELHI 110080 | SOUTH DELHI | DELHI | 110080 | Make: ACROMAX LITES
Model: AIPLLEDFLF300W-IP65 | ₹11.5 L+₹1.0 L (9.61%) | L3 | Qualified |
| 4 | L4₹11.8 L+₹1.3 L (12.5%)Qualified Make: SWIDO
Model: SWIDO-2FL-300W 38 J M S COMPLEX METTUPALAYAM ROAD KAVUNDAMPALAYAM COIMBATORE TAMIL NADU 641030 | COIMBATORE | TAMIL NADU | 641030 | Make: SWIDO
Model: SWIDO-2FL-300W | ₹11.8 L+₹1.3 L (12.5%) | L4 | Qualified |
| 5 | L6₹15 L+₹4.5 L (43.0%)Qualified Make: shreeg
Model: GLITZ300 157 E POCKET 4 MAYUR VIHAR PHASE 1 EAST DELHI | Make: shreeg
Model: GLITZ300 | ₹15 L+₹4.5 L (43.0%) | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
1 Oct 2018, 11:00 amClosed
Average Turn Over of Last 3 Years 60 Lakh (s) Experience with Gov. Required 3 Year (s) LED Luminaire (for Flood Light) ( 200 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated 300W * 1/7 Power Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP65 IP66
IP65
IP67 Mounting brackets (included) Adjustable * Warranty for free replacement (in Years) 2 * ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 90 to 300 V olts AC at 50 Hz+/-2 Hz * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * Total Harmonics Distortion (in %age) ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K * Working life for LED (Minimum 50
000 burning hours as per LM-80 report) Yes * Colour Rendering Index(CRI) ≥70 * Beam Angle ≥120 * Optic lense materal (UV stabilised) (Write NA for without optic lense supply) NA * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * 2/7 Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature < 85 degC * Operating temperature range -10 deg C to +55 deg C * Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV * The luminaire shall be protected against surges and transients of >/=10KV (External) No * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant epoxy powder coated Yes * All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * 3/7 Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
water
insects etc.
Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear (power supplies) 1 No. 1 No.
2 Nos.
3 Nos.
4 Nos. Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase
Neutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm * Light Source SMD LED Chip as per LM 80/IS16106 * MARKING "Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed * Manufacturer’s name
model number
serial Yes * 4/7 number Date of manufacture (month-year)
and lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND * System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output
power
PF
Current in Amps
CRI & CCT etc.
) Yes * LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being Yes * 5/7 used in the luminaire) Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * Seller has to furnish Type test report on demand by buyer/consignee Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bipin Kumar 825316
Regional Store Kuju Area CCL 200 15
638282
GEM/2018/B/90588
GeM Contract
LED Luminaire (for Flood Light)
GeM Contract
15 days
Jharkhand; Ramgarh
PRODUCT
Awarded to GANIT STAR ENGINEERING
₹10.5 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 300w Flood light | GANIT & SLIM-300W | - | 200 NOS | ₹5,245 | 1,049,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Average Turn Over of Last 3 Years 60 Lakh (s) Experience with Gov. Required 3 Year (s) LED Luminaire (for Flood Light) ( 200 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated 300W * 1/7 Power Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP65 IP66 | - | - | - |
| IP65 | - | - | - |
| IP67 Mounting brackets (included) Adjustable * Warranty for free replacement (in Years) 2 * ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 90 to 300 V olts AC at 50 Hz+/-2 Hz * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * Total Harmonics Distortion (in %age) ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K * Working life for LED (Minimum 50 | - | - | - |
| 000 burning hours as per LM-80 report) Yes * Colour Rendering Index(CRI) ≥70 * Beam Angle ≥120 * Optic lense materal (UV stabilised) (Write NA for without optic lense supply) NA * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * 2/7 Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature < 85 degC * Operating temperature range -10 deg C to +55 deg C * Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV * The luminaire shall be protected against surges and transients of >/=10KV (External) No * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant epoxy powder coated Yes * All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * 3/7 Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust | - | - | - |
| water | - | - | - |
| insects etc. | - | - | - |
| Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear (power supplies) 1 No. 1 No. | - | - | - |
| 2 Nos. | - | - | - |
| 3 Nos. | - | - | - |
| 4 Nos. Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase | - | - | - |
| Neutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm * Light Source SMD LED Chip as per LM 80/IS16106 * MARKING "Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed * Manufacturer’s name | - | - | - |
| model number | - | - | - |
| serial Yes * 4/7 number Date of manufacture (month-year) | - | - | - |
| and lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND * System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output | - | - | - |
| power | - | - | - |
| PF | - | - | - |
| Current in Amps | - | - | - |
| CRI & CCT etc. | - | - | - |
| ) Yes * LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being Yes * 5/7 used in the luminaire) Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * Seller has to furnish Type test report on demand by buyer/consignee Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bipin Kumar 825316 | - | - | - |
| Regional Store Kuju Area CCL 200 15 | - | - | - |
Exempted
13 Oct 2018
5 Oct 2018
contract_GEMC-511687723855352.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_638282.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .