| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC Being reasonable | |
| 2 | L2₹6.7 L+₹26,249 (4.07%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹7.0 L+₹52,680 (8.17%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹7.0 L+₹58,770 (9.12%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹7.3 L+₹85,555.70 (13.3%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
9 Oct 2020, 6:00 pmClosed
Shri Karan R Naik, AGE (I) RnD NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530 027
8307 REPAIRS AND REPLACEMENT OF INTERNAL WIRING, FIXTURES INCLUDING EARTHING, INDUSTRIAL SOCKETS ETC. IN NSTL TECHNICAL AREA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM
2020_MES_378780_1
AGE I R AND D NSTL VIZAG 8307
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class E
Category b i
7 documents required · 7 mandatory
₹500
AGE (I) R and D, NSTL
₹19,000
Yes
20 Oct 2020
18 Sept 2020
12 Oct 2020
18 Sept 2020
9 Oct 2020
2 Oct 2020
Amount
Taking down carefully aluminium/ copper point wiring for light, fan, socket or power point etc. complete including conduit but excluding fittings and fixtures such as ceiling rose, switch socket, pendants etc. including making good surface of wall, ceiling etc. complete all as specified.
M&L for point wiring complete with 1100 volt grade 1.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including rigid non-metallic PVC conduit/ PVC casing & capping of suitable size on surface, with all fittings including provision of earth continuity wire with same cable as for wiring but in green colour and connected to common earth dolly, fixed to wall/ ceiling/ floor/ roof including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting fixtures etc. suitable for one light/ fan point controlled by one switch 6 Amps 1 way.
All as per Item No. 2 herein before but for one 3 pin 6 Amp socket out let point on independent board.
All as per item No. 2 herein before but point wiring with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) duly earthed with same cable as for wiring above but green in colour as continuous earthing wire suitable for one 3 pin 16 Amps socket out let on independent board.
S&F in repairs switch piano, flush type, single pole, one way, 5/6 Amps, 230V AC all as specified.
S&F in repairs switch socket combination outlet 6 Amp, 2 in 1, 5 pin, 230 V AC all as specified.
S&F in repairs switch socket combination outlet 6/16 Amp, 2 in 1, 6 pin, 230 V AC all as specified.
S&F in repairs modular snap switch 6/ 10 Amp one way 230V AC all as specified.
S&F in repairs modular snap switch 16/ 20 Amp one way 230V AC all as specified.
S&F in repairs modular socket outlet 6/ 10 Amp multi pin socket for all pins 230V AC all as specified.
S&F in repairs modular socket outlet combination 16/ 20 Amp and 6/ 10 Amp heavy duty 230V AC all as specified.
S&F in repairs ceiling rose PVC/ Poly carbonate isolated body, three terminal complete all as specified.
S&F in repairs 2.5 mfd capacitor for ceiling fan 230 Volts, 50Hz AC.
S&F in repairs fan regulator electronic socket step type, 100 Watts, 240 Volts, flush type all as specified.
S&F in repairs electronic bell ding dong type working on 230 Volts AC supply complete all as specified. [Make: Anchor/ Standard/ Kinjal]
S&F energy efficient security light fitting 1x25W, with pressure die cast aluminium housing, polycarbonate cover, IP-6 consisting of high power LED, control driver etc. along with necessary cable connection with 3 Core 2.5 sq.mm copper cable, including 40mm dia GI pipe bracket, bolts, nuts etc. fixed to walls complete including taking down existing unserviceable fitting all as specified and as directed. [Cat No. LST-25-CDL-M of make: CG or techno-commercially equivalent in Bajaj/ Philips]
S&F in repairs LED box type 4' tube light fitting 20W with extruded aluminium housing & high quality PC diffuser complete with all accessories, internally prewired, connecting up with copper conductor cable of suitable size all as directed by Engineer-in-Charge. [Make: Cat No. CCS-100-20-65-HL2-DP-NWH of make: CG or techno-commercially equivalent in Bajaj/ Philips]
S&F in repairs LED 2' tube light fitting 10W with extruded channel of thermally conductive material, high translucent milky white diffuser complete with all accessories, internally prewired, connecting up with copper conductor cable of suitable size all as directed by Engineer-in-Charge. [Make: LD-10-NW of make: CG or techno-commercially equivalent in Bajaj/ Philips]
S&F High efficiency round LED high bay light fitting 80W, with aluminium PDC housing suitable for industrial application, having efficacy 110 lm/W with IP 66 protection, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed. [Make: LHB11-80-CDL/60-M of make: CG or techno-commercially equivalent in Bajaj/ Philips]
M&L for sub main wiring with 2 runs of 2.5 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn in and including rigid PVC conduit with all accessories, including provision of earth continuity wire with same cable as for wiring but in green colour complete including taking down existing unserviceable wiring all as specified and as directed.
M&L for sub main wiring with 2 runs of 4 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn in and including rigid PVC conduit with all accessories, including provision of earth continuity wire with same cable as for wiring but in green colour complete including taking down existing unserviceable wiring all as specified and as directed.
M&L for sub main wiring with 4 runs of 6 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn in and including rigid PVC conduit with all accessories, including provision of 2 runs of earth continuity wire with same cable as for wiring but in green colour complete including taking down existing unserviceable wiring all as specified and as directed.
M&L for sub main wiring with 4 runs of 10 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn in and including rigid PVC conduit with all accessories, including provision of 2 runs of earth continuity wire with same cable as for wiring but in green colour complete including taking down existing unserviceable wiring all as specified and as directed.
S&F in repairs MCCB 3 pole, 100 Amps, 25 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete all as directed. [Cat No. IHLGHT0100 of Make: Havells or equivalent in Legrand/ Schneider/ GE]
S&F in repairs MCCB 3 pole, 63 Amps, 25 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete all as directed. [Cat No. IHLGHT0063 of Make: Havells or equivalent in Legrand/ Schneider/ GE]
S&F MCB TPN 63 Amp, 16 KA, 415 V AC. [Make: Legrand/ Havells/ L&T]
S&F MCB SPN, 240 volts, 40 to 63 Amps, 10 KA all as specified and as directed. [Make: L&T/ Havells/ Legrand]
S&F MCB SP, 240 volts, 6 to 32 Amps, 10 KA all as specified and as directed. [Make: L&T/ Havells/ Legrand]
S&F in repairs sheet steel powder coated distribution board SPN 8 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 42 protection and double door, suitable for mounting MCBs all as specified and as directed. [Make: L&T/ Havells/ Legrand]
S&F in repairs sheet steel powder coated distribution board SPN 12 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 42 protection and double door, suitable for mounting MCBs all as specified and as directed. [Make: L&T/ Havells/ Legrand]
S&F in repairs sheet steel powder coated distribution board TPN 4 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 42 protection and double door, suitable for mounting MCBs all as specified and as directed. [Make: L&T/ Havells/ Legrand]
S&F in repairs sheet steel powder coated distribution board TPN 8 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 42 protection and double door, suitable for mounting MCBs all as specified and as directed. [Make: L&T/ Havells/ Legrand]
S&F in repairs single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB 20 Amps 240 Volts complete with plastic cover all as directed. [Make: Havells/ Legrand/ L&T]
S&F in repairs triple pole and neutral enclosure with three pin and earth plug and socket with one triple pole MCB 32 Amps 415 Volts complete with plastic cover all as directed. [Make: Havells/ Legrand/ L&T]
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to 4mm dia GI earth continuity wire by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, CI frame & cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion.
MVV Prasad
LAKSHMI SAI CONSTRUCTIONS
suresh electricals
SAI KRISHNA ASSOCIATES
R AND A ASSOCIATES ENGINEERS CONTRACTORS
ANJALI CONSTRUCTIONS
P VENKATA RAO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .