| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND RESONABLE | |
| 2 | L2₹29.7 L+₹2.2 L (8.16%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 3 | L3₹31.2 L+₹3.8 L (13.7%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 4 | L4₹33.0 L+₹5.5 L (20.1%)Rejected-Finance | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 5 | L5₹34.2 L+₹6.8 L (24.8%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L5 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
REPAIR AND REPLACEMENT OF INTERNAL ELECTRIFICATION ALONGWITH ALL CONNECTED ITEMS FITTINGS AT PRC MARRIED AND OTM ACCN AND MAINT OF SUB MAIN WIRING DBs TPN DBs GATE LIGHT AND CONNECTED ITEMS AT RAMGARH CANTT UNDER GE RAMGARH
2024_MES_667849_1
8300/3270/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹60,000
Yes
26 Nov 2024
25 Jul 2024
20 Sept 2024
25 Jul 2024
13 Sept 2024
8 Aug 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches(modular/non modular), ceiling roses, pendants, regulators, sockets,lamp holder , light fitting etc. and removing materials to store for keeping in safe custody or for taking as credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge.
M & L for surface point wiring for one light / fan /exhaust fan points/bell points controlled by one way 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & including PVC casing -N- caping non metallic medium grade with fittings (ISI marked) not less than 20 mm size & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted.
All as per item No. 02 mentioned here in before but one 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per item No. 02 mentioned here in before but one 3 pin 5 Amp switch socket outlet on same board with accessories complete all as specified and directed
All as per item No. 02 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed
M & L for surface point wiring for AC point controlled by one 15 Amps switch one way/metal clad industrial socket with 1100 volt grade PVC insulated-unsheathed 4.0 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 4.0 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in & including PVC casing -N- caping non metallic/ non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia( as per site requirement) including clamps, screws gutties/plug etc & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover complete all as specified and directed. Note : Proper coding to be adopted.
M & L for point wiring for one light/fan/bell point controlled by one 5 Amps single pole one way switch. with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in existing conduit & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 3.0 mm thick hylum sheet cover ISI marked fixed with brass screw complete all as specified and directed. Note : Proper coding to be adopted.
All as per item No. 07 mentioned here in before but one 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch. with accessories complete all as specified and directed
All as per item No. 07 mentioned here-in-before but one outlet 5/3 pin 5 Amps socket outlet on independent board controlled by one, one way 5 Amps piano switch with accessories complete all as specified and directed
All as per item No. 07 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 Sqmm wires complete all as specified and directed
M & L for point wiring for one light/ fan point/exhaust fan point/bell point controlled by one 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including clamps, screws gutties/plug etc & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc fixed with brass screw complete all as specified and directed. Note : Proper coding to be adopted.
All as per item No.11 mentioned here in before but one 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per item No. 11 mentioned here in before but one 3 pin 5 Amp switch socket outlet on same board with accessories complete all as specified and directed
All as per item No.11 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 Sqmm wires complete all as specified and directed
M & L for point wiring for AC point controlled by one way switch with 1100 volt grade PVC insulated FRLSH 4.0 Sq mm multi stranded copper conductor cable with continuous earth wire of 4.0 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed FRLSH, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including clamps, screws gutties/plug etc & sunken anodized pressed sunken boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches fixed with brass screw complete all as specified and directed.
Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65/66 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type security lights fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nuts, bolts & washers as required at site for fixing of security lights on LT pole/ wall complete including taking old security lights fitting any type and description complete all as specified and directed.
S&F in repair of bracket made of GI pipe light grade 1.2 Mtr long of size 40 mm bore, bend to shape as per site requirement fixed to pole/wall with flat iron clamp size 40mm x 5 mm -02 Nos with suitable bolts, Nuts, washers etc including two coats of synthetic enamel aluminium paint over a coat of red oxide primer on exposed surface of mild steel surface complete all as specified and directed.
S&F in repair decorative gate light LED 15 watt globe (conical shape) made up of high grade unbreakable polycarbon material specified and directed.
S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp breaking capacity 10 KA ,"B" series complete all as specified and as directed.
S&F in repair of old unserviceable twin core of flexible wire of size 23/0.0076 with PVC medium grade pipe 20mm dia for connection of post top lantern fitting from one junction box to other junction box complete all as specified and directed at site.
S&F PVC insulated Aluminium conductor wire 2 core 4 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire complete all as specified and directed at site.
S&F switch piano Flush type, single pole, one way ,5/6 amp 240 volts, complete all as specified and as directed.
S&F switch piano Flush type, single pole,15/ 16 amp 240 volts, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 15/16 Amps, flush type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 Amps flush type,universsal complete all as specified and as directed.
S&F Switch socket combination 2 in1, 3 pin,15/16 Amp flush type,universal complete all as specified and as directed.
S&F switch modular single pole one way 6 amp 240 volts,one Module complete all as specified and as directed.
S&F switch modular single pole one way 16 amp 240 volts, one Module complete all as specified and as directed.
S&F Modular socket 6A - 2/3 pin combined two module complete all as specified and as directed.
S&F Modular socket 16A- 2/3 pin combined two module complete all as specified and as directed.
S&F Modular Bell Push 6 Amp , One module complete all as specified and as directed.
S&F bell push flush type 5 amp AC, 230 volts, single pole complete all as specified complete all as specified and as directed. .
S&F in repair electric Bell, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S&F steped type modular fan regulator ,120 W, 1/2 module complete all as specified and as directed. .
S&F Stepped type electronic fan regulator on the existing phenolic laminated sheet complete all as specified and as directed.
S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and as directed. .
S&F in repair Plug top 15A ,240Volt complete all as specified and directed.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 4 way complete all as specified and directed by Engr-in-charge.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 8 way complete all as specified and directed by Engr-in-charge.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 12 way with complete all as specified and directed by Engr-in-charge.
S&F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Amp with breaking capacity 10 KA, in the MCB DB with connection testing and commissioning complete all as specified and as directed.
S&F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles (SP) and current carrying capacity 6 to 32 Amp with breaking capacity 10 KA ,in the MCB DB with connection testing and commissioning complete all as specified and as directed.
S&F in repair 415V, 10KA 'B' curve miniature circuit breaker (MCB) of triple poles and neutral (TPN) and current carrying capacity 40 to 100 Amp with breaking capacity 10 kA,in the DB with connection testing and commissioning complete all as specified and as directed.
S & F in repair MCCB, 4 pole, 415 V, thermal magnetic release setting with 100% ICU, 63 Amps to 125 amps with breaking capacity 16 KA, duly ISI marked, complete all as specified and as directed.
S&F in repair LED bulb of capacity 10 watts lumen out put (950 lm) length 102 mm, dia 56 mm, base cap B22, (ISI marked) complete with all accessories (ISI marked) all as specified & directed by Engr-in-Charge. .
S&F Inveter LED bulb of capacity 12 watts lumen out put (1200) length 140 mm width 70 mm base cap B22 ,3 star, (ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed.
S&F in repair LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr in Charge.
S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr in Charge.
S&F in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
S&F in repair LED luminaries 600 mm x 600mm, 35/36 watt, 220 Volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
M & L for sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including suitable size PVC casing-N- caping, medium grade ISI marked with all accessories such as tees,elbow,junction box etc.,, as required, fixed on surface of wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down of existing sub main wiring complete all as specified & directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing -N- capping shall be measured as one RM.
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and and testing on completion including taking down of existing sub main wiring complete all as specified & directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of conduit shall be measured as one RM.
M & L for Sub main wiring two single core 4.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 4.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and and testing on completion including taking down of existing sub main wiring complete all as specified & directed. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of conduit shall be measured as one RM.
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in existing surface/recessed PVC conduit complete and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable shall be measured as one RM.
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in surface rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable shall be measured as one RM.
M & L for Sub main wiring four single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and two run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including existing surface/recessed PVC conduit complete and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Four runs of 6 sqmm and two run of 6 sqmm cable shall be measured as one RM.
S&F in repair 1100 V grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular of size 10 sqmm complete all as specified and directed
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as specified and shown in electrical plate No.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate )chamber with RCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) , 40 mm thick pre cast RCC cover with TMT 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering including taking down of existing earthing complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, returning, filling in and removal etc
S&F in repair Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and such as couplers, lock nuts, saddles, pipe hooks etc.
S&F in repair of 3mm thick phenolic laminated hylam sheet of size 9" X 11" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. Note: Supply only switches & sockets shall be measured and paid separately under respective item of BOQ.
S&F in repair of 3mm thick phenolic laminated hylam sheet of size 8" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. Note: Supply only switches & sockets shall be measured and paid separately under respective item of BOQ.
S&F in repair of 3mm thick phenolic laminated hylam sheet of size 5" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed Note: Supply only switches & sockets shall be measured and paid separately.
Supply only switch piano flush type polycarbonate single pole one way 6 Amps complete all as specified and directed .
Supply only switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x 5mm buried directly in ground vertically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level) connected to earth electrode of 17.2 mm dia in 3 meter long low carbon steel electrode with copper bonding of thickness, environment friendly backfill and suitable clamp, back fill earthing enhance compound strictly being Carbon based conductive concrete connected to copper earth wire of size 10 mm dia by means of bolts and nuts check nuts and washers of copper with copper plate by brazing) at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil earth, GI pipe light grade 20mm bore for protection of copper strip from earth electrode to and including the earth test point, adequate quality of charcoal dust and common salt and magnesium sulphate in alternate layers of 100mm thick x 6 layers all around the copper plate and RCC cover of size 54cmx54cmx50mm with 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bars @75mm C/C both way with MS handle 12mm dia, PGI funnel with wire mesh, 20mm dia GI pipe medium grade for watering complete all as specified and directed. Note – (a) Cost of copper strip and GI protection pipe up to a distance 7.5M shall be included in quoted rate of above items. (b) On testing, after completion of job, if desired earth resistance (less than 1 Ohm) is not found, the earthing shall be reconstructed by the contractor without any extra cost to the Govt.
Taking down/ transporting the panel from AGE E/M yard to respective sites as required and refixing of metering panel of any size in position so as to accommodate single phase meters alongwith testing and refixing of old meters to 3 phase and neutral 415 V, 50 Hz AC system (04 metres) inclusive of connection complete to incoming and outgoing compartment chambers using all connected accessories like Nuts, Bolts, washers, ferrule numbers, cable ties, tie base, copper PVC control wire power wire, copper thimbles,PVC tape, insulators E-type, L-Type, round type, complete all as specified and directed by Engr-in-Charge.
Taking down existing serviciable tube light fitting/any serviciable LED light fitting of any wattage after disconnecting with all necessary electrical connections from ceiling rose to fitting and refixing the same in another place/location as directed by Engineer -in Charge complete all as specified and as directed.
S & F in repair sheet metal enclosures for DBs single pole & neutral 2 way single door with including suitable amp rated bus bar and neutral link (ISI marked) suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed surface of wall complete all as specified and as directed.
S&Fin repair factory made epoxy powder coated sheet metal enclosures for Distribution Board VTPN DB's 4 ways, 415 volt grade ,IP-43 protection,IK-09 with metal double door including 200 amp rated copper bus bar with two neutral bar , earth bar & cable ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for MCCB as incomer and SP/TP MCB as out going four way including strandard DIN rail, for cable management, top and bottom removeable gland plates with knockouts complete all as specified and as directed.
S & F in repair sheet metal enclosures for DBs tripple pole & neutral 4 way double door with including suitable amp rated bus bar and neutral link (ISI marked) suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed surface of wall complete all as specified and as directed.
S & F in repair 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor size of 16 sq.mm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4 mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
S & F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole & neutal (SPN) and current carrying capacity 40 amp to 63 amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply, laying ,jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq.mm.,4.0 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
Supply, laying ,jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq.mm.,4.0 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
Supply, laying, jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq.mm., 3.50 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr in width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes, foundations, etc. complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Supply and spreading clean, dry, fine river sand for under ground(UG) electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
S & F in repair 50mm dia GI pipe light grade for protection of LT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
M&L for Boring of hole under road, pavement, hard standing by trenchless using manual technique with required tools complete all as specified and directed by Engineer-in-Charge. Note : (i)Pipes shall be laid minimum 2.00 mtr below/under existing road surfaces/ apron /floors etc. (ii) T&P requird for road boring to be provided by the contractor at site own cost and no any claim enterained on this accont on later stage.
M/S Kunwar Construction (BID ID -3086166)
M/S Akash Enterprises (BID ID -3089832)
M/S Bhushan Kumar Jain (BID ID -3089479)
M/s Ray construction (BID ID -3084836)
ganpati enterprises (BID ID -3085079)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .