Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 CrAccepted-AOC | ₹13.1 Cr Quoted ₹14.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹14.6 CrRejected-Finance B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | ₹14.6 Cr | L2 | Rejected-Finance 2 Lost |
| 3 | Rejected-Technical | - | - | Rejected-Technical technicaly non qualified |
Tender Value
Refer Docs
EMD Value
₹27.7 L
Closing Date
4 Feb 2023, 5:00 pmClosed
Superintending Engineer
Office Of Superintending Engineer Construction Circle Uttarakhand Peyjal Nigam Pauri
construction Surveying Design Supply Cartage laying Jointing of GI API Pipe of 15mm to 250mm dia by Socketing Electric arc welding Const of R.C.C BFG with Intake Chamber 2.20 MLD WTP RCC Circular Sump CWR 300 KL Capacity Pump House Staff Quarter ot
2023_MDPEY_54253_1
263/NIVIDA QUOTATION/68 DATED 21-01-2023
Open Tender
Civil Works - Water Works
365 days
Dugadda
As per Tender Document
3 documents required · 3 mandatory
₹5,900
Executive Engineer, C.D. Peyjal Nigam Kotdwar
₹27.7 L
kotdwar
26 Sept 2023
21 Jan 2023
7 Feb 2023
21 Jan 2023
4 Feb 2023
30 Jan 2023
21 Jan 2023 - 27 Jan 2023
27 Jan 2023
Amount
Design (hydraulic & structural) and construction of Water Treatment Plant of capacity 2.20 MLD comprising Pre-sedimentation tank, coagulation Flash mixer, Clariflocculator Tanks, Hopper Bottom settling tanks units & Rapid gravity sand filter Filter & Chemical house, Back wash Tank, Supply & installation of electro-mechanical equipment for Flash mixer, Clariflocculator, Filter & Chemical House including supply of all material, labour, T&P etc. complete as per specification of work.
Supply of all materials, labour, T&P etc Complete & Construction of Pump House as per deptt design & drawing in FPS Bricks 6.00 x 5.00 x 4.50 m in size including supply of all labour material T&P etc complete as per approved designed & drawing including all neceassary arrangements required for installation of motor & Pumps.
Supply of all materials, labour and T & P etc. and construction of Staff Quarter (Type I) for Pump Operators and Chaukidar as per type design and drawing and direction of Engineer-In-Charge.
Excavation in foundation for site development, retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
PCC 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) including supply of all materials, labour, T&P etc. complete as per direction of Engineer-In-Charge.
PCC 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) including supply of all materials, labour, T&P etc. complete as per direction of Engineer-In-Charge.
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction as per direction of Engineer-In-Charge.
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704,1202 & 1203 of MORD Specifiction as per direction of Engineer-In-Charge.
Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assuming that 90% pipe line is laid in trenches, it is estimated that 75% excavation will be in soil mixed with shingle, bajari and boulders and rest 25% will be in medium rock
Soil mixed with Shingle, Bajri and Boulders
Medium Rock
Survey, design, Supply of pipes and fittings of following grade & sizes (in mm) of MS ERW Pipes (YST 210) Graded Cartage of pipes and fittings from site store to site of works, lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line by welding for making up lengths as required for proper completion of work of following sizes (in mm) MSERW Yst 210 GRADED PIPE
200 mm dia., 4.80 mm thick
250 mm dia.,5.6 mm thick
250 mm dia., 4.80 mm thick
Survey, design,Supply of pipes, specials and fittings of following grade & sizes (in mm) Cartage of pipes, specials and fittings from site store to site of works, lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line including cutting and threading of pipe for making up lengths as required for proper completion of work of following sizes (in mm) of GI (M) Pipe G.I. (Medium) Pipe
15 mm dia
20 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
125 mm dia
150 mm dia
Dismantling of following dia G.I pipe including taken out from pipe line trenches and staking properly as per Direction of Engineer-In-Charge.
50 mm dia.
65 mm dia.
80 mm dia.
Painting of MSERW/API Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) (dia. of pipe in mm)
Supply, cartage and fixing of C.I. D/F Sluice Valves Confirming to IS: 14846-2000 (Kirloskar or equivalent) PN 1.6 including supply of all labour, material, T&P etc.complete as per direction of Engineer-In-Charge.
Air valves (Screwed)
20 mm dia
Supply, cartage and fixing of C.I. Double acting type Air valves, including supply of all labour, material, T&P etc.complete.
Supply of all materials, labour, T & P etc. and Construction of Sluice Valve / Reflux Valve / Scour Valve Chamber as per type design complete (Size :- 1.50 m x 1.50 m x 1.50 m)
Supply of all materials, labour, T & P etc. and Construction of Air Valve Chamber as per type design complete (Size :- 1.50 m x 1.50 m x 1.50 m)
Supply of all materials, labour, T & P etc and construction of Wheel Valve chamber as per type, design (Size :- 1 m x 1 m x 1 m)
Supply of all materials, labour, T & P etc and construction of Air Valve chamber as per type, design (Size :- 1 m x 1 m x 1 m)
Supply of all materials, labour, T & P etc and construction of Sluice Valve chamber as per type, design (Size :- 0.60 m x 0.60 m x 0.60 m)
Supply of all materials, labour, T & P etc and construction of Air Valve chamber as per type, design (Size :- 0.60 m x 0.60 m x 0.60 m)
Supply of all materials, labour, T & P etc. and Construction of Anchor Block as per type design complete of following sizes as per direction of Engineer-In-Charge.
Size - 1m x 1m x 1.5m
Size - 0.8m x 0.8m x 1.2m
Size - 1.2m x 1.2m x 1.4m
Size - 0.8m x 0.8m x 1.2m
Providing and fixing CP Brass Bib Cock of Approved Quality confirming to IS :8931: 15mm Nominal bore
Providing & Fixing Ultrasonic Water Flow Meter for Bulk pipe lines inline type, flange end with Integral mounted, Flow rate & Totaliser display, Battery operated (with five year battery life) Communication : UART/RS485, suitable against antifraud attempts etc. including all necessary fittings complete.
100 mm dia
250 mm dia
P/F AMR Water Meter Class B Multijet as per IS 779-1994 or ISO 4064-2005 CE mark IP68 along with - (i) LORA based AMR Module of 5Km range and with frequency band 865 MHz, maximum power upto 20.5 DBM. (ii) Non rechargeable Lithium Ion battery with 5 year Battery life (Considering 1 reading / day). 15 mm
Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials.
Ferrule Connection (Labour cost only including index)
Supply of all materials, labour, T & P etc. and fixing of C.I. Surface Box for Water Meters
Supply of all materials, labour, T&P etc and construction of R.C.C. Sump / CWR of following capacities (KL) with M.S. ladder outside & inside of the tank, M.S.M.H. cover with locking arrangement, cowl, outlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT/M2 .
Supply and installation of Bucket Type Chlorinator of 25 L Capacity on the top of Service Reservoirs
Provision of 1.5 m high Boundary Wall in brick masonry including supply of all materials, labour, T&P etc. complete
Provision of Iron Gate with Pillars of following sizes complete
3.6 m wide
Construction of 2 meter wide Cement concrete Approach path including necessory cutting , excavation protection for making grade 1:20 link road with coolie walling
Provision of Drainage System consisting of following works
Manhole chambers
Supply of all materials and construct 150 mm S.C. drain including supply of all labour T&P etc complete
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer in charge - for bituminous road
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : Water bound macadam road
Reinstatement of following type of road surface for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
Kaccha Road
Dismantling and reinstatement of following type of road surface for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
C.C. Road
Instalation of Product Pipe by Auger Boring method including making of entry and exit pits, all related civil works like excavation, horing/ strutting, etc., shielded excavation through auger boring process, lowering of pipe segments in the jacking pit, laying and jointing of product pipeline through jacking process from the jacking pit and after project completion as per the instructions of the Engineer-in-charge all complete except the cost of the pipe. (upto 80 meter installation length) Upto 300 mm dia (In all type of Soil)
Design, Drawing and Supply of all material, labour, T&P etc. and Construction of RCC Boulder Filled Gallery ( BFG ) including Intake Chamber in RCC 1:1.5:3.
Construction of Diversion of Gadhera, including supply of all material, Labour, T&P etc. Required for proper completion of work.
Construction of extra length of RCC Cross Wall including supply of all material, Labour, T&P etc. Required for proper completion of work.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats.
PC plaster with cement mortar in 1:6 Minimum thickness 15 mm including ,racking of joints, supply of all material, labour, T&P etc all complete as per direction of Engineer-In-Charge.
Providing and laying Reinforced cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) at the back of treatment plant
Centering and shuttering including strutting, propping etc. and removal of form work for :Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Supply & Fixing an Iron Board and Printing on it as well as writing the details of Work on it as per direction of engineer-in-charge.
Operations & Mainteanance Dugadda Pumping water supply scheme (Amurt-2.0)
Supply of electric driven V.T. Pump suitable to operate in raw water capable to delivery Raw water 1600 LPM Discharge 40 meter 1450 rpm complete
VHS electric motor suitable to suitable for above pump.
Main switch, 100 AMP
Fully automatic A.T.S oil cooled starter suitable for above motors.
Control Panel
Supply of 1x3x16 sq.mm submersible flat copper cable
1x3.5x50 sq.mm Aluminum armoured cable
Double loop earthing as per site requirement
Jointing materials such as lugs, tapes etc. as required.
Supply of main piping & valves as per site requirement
Supply of (0-20 kg/cm²) pressure gauge and compound gauge complete.
Tools as per site requirement
SITC of 3 Tone, 20 Mt. Lift capacity chain pulley block with travelling arrangements complete.
Supply of rubber resistance sheet of size 1m x 2m x 0.025m
Installation & Commissioning of above Pumping Plants .
Testing of Pumping Plants At works
Testing of Pumping Plants At Site
Painting
Cartage of Pumping Plants
MPS- Centrifugal pumps delivering 1800 LPM discharge at 80 Mts. head.
Electric motor suitable to run above motor
Base Plate
Fully automatic A.T.S oil cooled starter suitable for above motors.
Control Panel as per Site requirement
120 mm² 3½ core Al Conductor Armoured PVC Sheathed cable
25 mm² 3 core, Cu Submersible cable 1.1 KV grade.
Jointing materials such as lugs, tapes etc. as required.
Complete double loop earthing as per site requirement
Supply of main piping & valves as per Site requirement
Supply of (0-50 kg/cm²) pressure gauge and compound gauge
Tools as per site requirement
SITC of 3 Tone,4.5 Mt. Lift capacity HOT chain pulley block with travelling arrangements complete.
rubber resistance sheet of size 1m x 2m x 0.025m
Installation & Commissioning of above Pumping Plants .
Testing of Pumping Plants At works
Testing of Pumping Plants At Site
Painting
Cartage of Pumping Plants
Transformer Intake well - 63 KVA
Transformer MPS - 100 KVA
Internal & external electrification Intake well & M.P.S
Cost of S.I.TC of H.T Panel as per site requirement
Complete double loop earthing as per site requirement
SITC of HT cable Jointing kit outdoor type / Indoor type
Cost of fencing of transformer
Supply of XLPE,3 Core, 70 mm sq. H.T. alumuniam armoured cable
AUTOMATION- GSM based remote terminal units
GSM based wireless communication hardware for RTU’s.
Intelligent Energy meters suitable for automation.
Valve Actuator for 200 mm dia valve.
Actuator Panel
Hard wired timer circuit for actuator
Pressure Transmitter
Level transmitter of 10 mt range
Isolation Transformer (440 V step down 220 V for protection of site automation)
Electromagnetic flow meter 200mm Dia.
Single cabling between RTU and field instruments, 2 Core x 1.5 sqmm PVC coated flexible screened cable.
4 C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
10C x 1.5 sq mm PVC coated flexible unsreened Cu cable.
Conduit pipe 1” PVC
Conduit pipe 1.5” PVC
Accessories like conduit pipe flexible pipes, PVC bend, AC & DC relays with base, lugs etc.
Erection commissioning of all instruments and customization of software.
O&M- After testing & commissioning of scheme running & maintenance of scheme by running pumping plant for 16 hrs per day (for a period of 6 months or complete Distribution line testing of civil works which over later ) including supply of skilled O&M staff, account maintenance including supply of all materials, labour, T&P etc. complete but excluding electricity charges for pumping of water.
R K ENGINEERS SALES LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid